NEATEST WAY TO INSTALL A CONSUMER UNIT

Тәжірибелік нұсқаулар және стиль

TODAY I TRY SOMETHING NEW WITH THE WAY I INSTALL MYU CONSUMER UNITS AND THE RESULTS ARE SO MUCH BETTER THAN EXPECTED.
follow us on instagram click on the link / greenhawkconstruction
~-~~-~~~-~~-~
Please watch: "REDOING WORK TRADIFY"
• I Can't Stand Redoing ...
~-~~-~~~-~~-~

Пікірлер: 41

  • @iainball2023
    @iainball2023 Жыл бұрын

    Long time late to leave a comment, but it always makes me feel good when I leave some spare cable tucked away for the next person, but I also think if I'm doing it right nobody will ever know.... Nice video, nice workmanship. 👍

  • @polarbear7720
    @polarbear77202 жыл бұрын

    As you have installed the trunking I would leave a loop of cable in trunking for some slack and cut cables short and neat in board.

  • @supersparks9466
    @supersparks94664 ай бұрын

    My preferred method for the last 30 years, glad you’re on board

  • @peterc3228
    @peterc32282 жыл бұрын

    The extra length of conductors in the consumer unit is much appreciated when you come to do an EICR👍

  • @Honest_Reviewer.
    @Honest_Reviewer.2 жыл бұрын

    Awesome video. Thank you for sharing these.

  • @mrdivoc1729
    @mrdivoc17293 ай бұрын

    Only thing I'd change is the band, you can get plastic coated band instead of sharpish metal edged stuff. Oh and I'd put ferrules on the fine wire multistrand rcbo neutral fly leads.

  • @davidclarke2513
    @davidclarke25137 ай бұрын

    It's a sound installation of the consumer unit as long as you have allowed for holes in the back for your spare ways to be wired into

  • @darrenqualters2341
    @darrenqualters23412 жыл бұрын

    Another great video. Love that trick with the laser level on the saw, absolutely brilliant, never seen that before 😄👍

  • @GreenHawkConstructionltd

    @GreenHawkConstructionltd

    2 жыл бұрын

    It’s so simple but works every time 🤙

  • @ExtremeShez

    @ExtremeShez

    2 жыл бұрын

    @@GreenHawkConstructionltd Thank you for sharing these videos. A lot to learn.

  • @jamescourt2842

    @jamescourt2842

    9 ай бұрын

    @@GreenHawkConstructionltd I'm ever so sorry to be pain by bending your ear I’ve just started Level 2 Diploma installation hopefully I will get through 2 years then on eventually get my level 3 done. How much length on each neutral you've got coming through back into RCBO an how much have you stripped off 10/12mm feeding into the terminal on the rail? I only ask as I'm so nk only 3 weeks into my course an I eagerly want to be ahead of my game on-site when I get around to it 😂 Thank you 🙏

  • @MMG_MoonManGuitar
    @MMG_MoonManGuitar2 жыл бұрын

    Love this. Super neat finish mate!

  • @GreenHawkConstructionltd

    @GreenHawkConstructionltd

    2 жыл бұрын

    Thanks buddy 👍

  • @terryselectricalservices8234
    @terryselectricalservices82342 жыл бұрын

    Fitted a few of fusebox boards last couple of years , had few rcbos stop working after 12/16 months , don’t use them anymore , nice job thou

  • @jamiekent1970
    @jamiekent19709 ай бұрын

    Great ideas on fitting a CU, just wondering if you took in account the grouping factor of having all your outgoing cables bound close together like that in trunking??🤔

  • @jonesconrad1
    @jonesconrad12 жыл бұрын

    Love the saw trick.

  • @richardhennessy7684
    @richardhennessy76842 жыл бұрын

    Like yourself love a fusebox. I use 75 mm trunking as it fits nicely on the top the full depth of the box. surface mount the cu and open up all the top 20mm knockouts to 25 mm then slot the trunking to fit so anybody following up has full access. Use the mini RCBO's as they give you a bit more room and loop the L and N's down up down into the RCBO so there is a bit of slack for the future. Also use the flat Wiska tails glands as less bulky than the 32/40mm stuffing glands.

  • @ImranKhan-cf8gs
    @ImranKhan-cf8gs2 жыл бұрын

    Quality job

  • @supersparks9466
    @supersparks94664 ай бұрын

    I don’t tuck any slack behind the breakers,just a little loop up and over, never straight in.

  • @no_short_circuit
    @no_short_circuit2 жыл бұрын

    Thanks for the video. As a learner, what is your view on the grouping factor of all those cables in the trunking?

  • @cms4467
    @cms44672 жыл бұрын

    Great video. Have to say not sure if I was that taken with coming in that low with the holes. Think it will make it hard for the next phase and next person if /when you need to add anything to get the cables in to the board without removing the breakers.

  • @KTWElectrical
    @KTWElectrical2 жыл бұрын

    Just come across your channel, decent content keep it up guys 👍

  • @GreenHawkConstructionltd

    @GreenHawkConstructionltd

    2 жыл бұрын

    Welcome buddy glad you like it 👍

  • @pyrrhical3423
    @pyrrhical34232 жыл бұрын

    Not a fan of bringing cables in from behind, it may look neat but most people shove excess length and the fly leads down the back which I think is a bit shit. Top entry and loom the cables round with sticky pads and small panel ties leaves length and looks neat

  • @marcwilliams3921
    @marcwilliams39212 жыл бұрын

    I like to bush brass bushes and couplers for db to trunking. Good job

  • @corynoahmac
    @corynoahmac2 жыл бұрын

    Beautiful job mate

  • @GreenHawkConstructionltd

    @GreenHawkConstructionltd

    2 жыл бұрын

    Cheers Cory 🤙

  • @ForTheBirbs
    @ForTheBirbs2 жыл бұрын

    Thanks for another great video. Nice to see a consumer unit in a practical location. Lol. How is off-peak switching done in UK? In Aus the energy supplier injects a tone to lines to switch off-peak (hot water supply) on and off and has a separate meter. The tones can play havoc with LED dimmers with harmonics / interaction with the 50Hz.

  • @carlmarquardt994

    @carlmarquardt994

    8 ай бұрын

    Zelweiger meter

  • @ForTheBirbs

    @ForTheBirbs

    8 ай бұрын

    ​@@carlmarquardt994that's the one. Cheers

  • @northeastcorals
    @northeastcorals Жыл бұрын

    Why have I only just seen the laser level on the saw trick now!!!!😆😆😆

  • @johngod88
    @johngod882 жыл бұрын

    Got a look of jimmy Anderson

  • @londontrada
    @londontrada2 жыл бұрын

    You cant use plastic clips for the fire rated fixings, it defeats the object.

  • @mikenewman9372
    @mikenewman93722 жыл бұрын

    Never understood why you guys pick the cheapest imported con unit you can get hands on. In a few years, when the agent stops importing Fusebox products and you need a replacement or additional device , you’re stumped. New con unit needed to adhere to the regs. For £50 more get a Hager or Crabtree unit from proper manufacturer’s, I’m sure the customer would pay the uplift if you explained the reason why.

  • @JohnDundee-el2ro
    @JohnDundee-el2ro5 ай бұрын

    Knockout the big knockouts every time with the large easy fit grommet strip fuesboards higher 1400 to the bottom always I don't agree with who can do the fuesboards the neatest or artisan this 5 star electricians crap as long as the inside of the boards neatish and screws checked and tightened properly there is a cover on fuesboards no one can see the inside of the fuseboards leave enough slack in your cables for the future moving all the boards up would be major also your off peak DP switches better if they are indicated I am not saying you shouldn't care about the work you do Cheers

  • @DerekHundik
    @DerekHundik2 жыл бұрын

    where is the finished product ? NEATEST WAY TO INSTALL A CONSUMER UNIT ends 12:50 Where is the punch line ?

  • @2010Mrturk

    @2010Mrturk

    2 жыл бұрын

    Exactly that mate and didn’t show much of installing the consumer unit. Too much chat from him

  • @adreenryan2901
    @adreenryan29012 жыл бұрын

    Why are you bunching them all together you must want them to heat up.

  • @2010Mrturk
    @2010Mrturk2 жыл бұрын

    You do talk to much mate just stick to the point also ‘neatest way to install’ but you didn’t show us getting the board on or putting away the earths and how you know which circuit is what with no labels.

Келесі