Midea air conditioners professional and fast installation on GUAM

Make an appointment online:
aellco.com/make-appointment/
Guam Toll free: +1(800)706-2719
Local: +1(671)488-8417
WhatsApp: +1(671)488-8417
•Our technicians are at your service 7 days a week from 8:30 am to 5:00 pm (the last order at 3:00 pm).
•Our client service manager is able to assist you Monday to Friday from 8:00 am to 5:00 pm.

Пікірлер: 359

  • @moeezsiddiqi9864
    @moeezsiddiqi98648 ай бұрын

    Great Work You My Teacher👍

  • @ptsmotoadventures
    @ptsmotoadventures2 жыл бұрын

    Great Job, Nice Powertools

  • @positivevibes-gz4gy
    @positivevibes-gz4gy2 жыл бұрын

    Just so you know you drilled the hole on the wrong side. If you ever need to service the evap head you won't be able to pull the head away from the wall.

  • @mountainklima5602

    @mountainklima5602

    2 жыл бұрын

    I know what you mean , but the wall is very slim , you can check it from the outside you can see it in 1;21 it comes out

  • @MarcelHVAC

    @MarcelHVAC

    Жыл бұрын

    no

  • @hunyadijanos7678

    @hunyadijanos7678

    Жыл бұрын

    Get 60cm pipping. Nice.

  • @electricaloneonone

    @electricaloneonone

    Жыл бұрын

    It doesn't actually make a difference what side the hole is on 🙂 if you are going to pull it off the wall, you'll have to disconnect the refrigeration pipes anyway 🙂

  • @MarcelHVAC

    @MarcelHVAC

    Жыл бұрын

    @@electricaloneonone You are right

  • @kiantracker1499
    @kiantracker14992 жыл бұрын

    Hi. Best regards, refrigeration and air conditioning technicians. Greetings from Indonesian technicians.

  • @MsladyPearlz
    @MsladyPearlz9 ай бұрын

    Finally got it up and running. The only delays we had was because we realized we needed some extra parts (I’ll list that below) kzread.infoUgkxihMYiJNXcHdbH-7ihymsLz61l7jVyb5O . So we have a loft where our current hvac just couldn’t seem to keep cool during the summer. We have been using a window unit since we bought this house over 6 years ago (all the houses in this neighborhood were built in the 80’s and majority of the houses built like ours use a window unit). I hate window units because they are just so noisy and the one we had really only cools one side of the loft. I had contemplated upgrading our current HVAC, but with all the rising prices these days, it would take years before saving up enough to do that. With the advice of my father-in-law (used to run an HVAC business), he recommended we get an inverter instead. We thought we bought everything we needed, but there were just a few other parts we didn’t anticipate needing (which is what caused most of our delay). My friend and father-in-law did all the work to get it installed and running and now we have nice cool air circulating nicely throughout the entire loft. It is very quiet and even the outside unit is much quieter than our main HVAC unit. Saved ourselves thousands getting this.

  • @SonuYadav-dc9ft

    @SonuYadav-dc9ft

    4 ай бұрын

    8😊pgtu p8 1:36 to get

  • @mikepict9011
    @mikepict9011 Жыл бұрын

    Their like a useful version of a scientist

  • @joelferreira4020
    @joelferreira4020 Жыл бұрын

    Great job. Could you please tell me who sells the articulated cable trunking in europe that they put in the exterior unit?

  • @sysadmin1947
    @sysadmin19472 жыл бұрын

    Excellent Great Work

  • @Adreesuploads
    @AdreesuploadsАй бұрын

    Any videos on how to replace a compressor on these units or simar units like this one ..my air conditioner isn't letting out really cold air so I'm assuming the gas in compressor needs refill or replaced the unit is about 7 years old and only been used mostly in the summer doest the compressor be in the unit inside or the fan on the outside?

  • @HelloMTRS
    @HelloMTRS2 жыл бұрын

    Nice work 👍

  • @MegaJawaMan
    @MegaJawaMan Жыл бұрын

    I like it. This house was very nice. But now it si perfect 😍

  • @jivazzieraspiazu3762
    @jivazzieraspiazu37622 жыл бұрын

    Una consulta dónde están los 3 metros de tubería que pide como mínimo el fabricante

  • @welitonbruscato8188

    @welitonbruscato8188

    2 жыл бұрын

    Parece que não tem. Ou possa ser que as normas do fabricante mude 😬😬

  • @kayyumkhan7255

    @kayyumkhan7255

    2 жыл бұрын

    Hasankhan

  • @ivaneduardovelazquez6489

    @ivaneduardovelazquez6489

    2 жыл бұрын

    Para que o que igual mejor así

  • @JesusRuiz-ro1sh

    @JesusRuiz-ro1sh

    2 жыл бұрын

    Por donde avacua el agua del compresor🤭a tuti pley, ni los mas profesionales son profesionales, menuda caca

  • @JesusRuiz-ro1sh

    @JesusRuiz-ro1sh

    2 жыл бұрын

    Y dejar la caja de corriente justo por donde tira el agua el compresor

  • @shiven7841
    @shiven78412 жыл бұрын

    Very neet and clean work

  • @bluecollardownunder3616
    @bluecollardownunder3616 Жыл бұрын

    Have you ever install multi split before?

  • @roypjohno8118
    @roypjohno81182 жыл бұрын

    Hai Good Morning Super Ac fitings Super job Super idea Super Spead work 👍👍👍👍👍👌👌👌👌👌

  • @patascaprina
    @patascaprina Жыл бұрын

    Y que pasó con la bomba de vacío para sacar la humedad de la cañeria y el manometro para estar seguro de la presión adecuada? Y como le harás la mantención después con esos equipos tan pegados a la pared???, Y los desagüe se los llevaron en la camioneta?...

  • @manishmonu26
    @manishmonu262 жыл бұрын

    Nice installation 👍 I am from Punjab. 🇮🇳

  • @kadirrajput5373

    @kadirrajput5373

    2 жыл бұрын

    Good working where are you from

  • @JasonNYC5454
    @JasonNYC54542 жыл бұрын

    Neat job. I guess electrician have to supply power to the disconnect switch box.

  • @sergiodave6497
    @sergiodave64972 жыл бұрын

    No respetan los 3 metros de cañería que piden por garantia

  • @darielpozo8209

    @darielpozo8209

    2 жыл бұрын

    Cómo así??, explica eso.

  • @oliveii_1391

    @oliveii_1391

    2 жыл бұрын

    Achei que apenas no Brasil que não respeitavam, isso é no mundo todo.

  • @welitonbruscato8188

    @welitonbruscato8188

    2 жыл бұрын

    @@oliveii_1391 e mundial 😂 😂 😂 😂 😂 aqui o lema é o importante gelar, lá tmb 😂 😂 😂 😂 no investimento que eles tem pelo menos o mínimo deveria ter de Tubulação

  • @EsdrasCirqueira

    @EsdrasCirqueira

    2 жыл бұрын

    Varia de marca pra marca alguns são 03 metros outro 02 mts outros acima de 04mts importante é gelar o.probelma não a tubulação é sim o excesso de gás que fica na máquina pra distância de tubos a menos

  • @KingKhan-if6oq
    @KingKhan-if6oq2 жыл бұрын

    Amizing,. But why the excletr of Elictrical down with outdoor, when u serviceing the unit the water can demage it,.

  • @mohsenpanahi6773
    @mohsenpanahi677311 ай бұрын

    May the God give you the strength.

  • @lilheng1694
    @lilheng1694 Жыл бұрын

    They're so professional and handsome👍

  • @jaimebernabesanchezparedes4234
    @jaimebernabesanchezparedes42342 жыл бұрын

    Saludos cordiales colegas Yo Realizó o hago el pasado de las CAÑERÍAS de gas y líquido x el lado izquierdo Ojo pará poder dar el buen mantenimiento

  • @KumarKumar-zh7fe
    @KumarKumar-zh7fe2 жыл бұрын

    Your work good finished

  • @barrypierce9100
    @barrypierce91002 жыл бұрын

    Nice job...clean

  • @tamilarasan-gm1lr
    @tamilarasan-gm1lr2 жыл бұрын

    Very good finishing

  • @NoorRefrigerationsystem
    @NoorRefrigerationsystem Жыл бұрын

    Good job ❤️

  • @sreejithts9798
    @sreejithts97982 жыл бұрын

    good technician doing perfect work in proper way

  • @ramonvenegas7644

    @ramonvenegas7644

    Жыл бұрын

    Good technicians don't work on ladders, platform ladders are for that..

  • @5885ronny

    @5885ronny

    Жыл бұрын

    Gut 👍

  • @RedSunFX
    @RedSunFX Жыл бұрын

    I remember reading in the manual that you should have 3 meters minimum line length. So it's alright to go shorter?

  • @CD-gl7ix

    @CD-gl7ix

    Жыл бұрын

    Yes, but you must reduce the refrigerant. a short line is not recommended because it could transfer noises from the outdoor unit to the indoor unit.

  • @maciastrn3024

    @maciastrn3024

    Жыл бұрын

    2meters.

  • @josuenolasco382

    @josuenolasco382

    7 ай бұрын

    Muchas teorías, si se corta la tubería o no.. La estética de la instalación es espectacular con la tubería exacta.

  • @carlosschmidt6035
    @carlosschmidt60359 ай бұрын

    An excellent and Beauty installation

  • @prasadsharma26
    @prasadsharma262 жыл бұрын

    Ur work super 🙏

  • @Haryanawal

    @Haryanawal

    Жыл бұрын

    Not super

  • @user-pt2xv1tg8i
    @user-pt2xv1tg8i Жыл бұрын

    室外機要比室內機低!停機後內部冷凍油才會流回室外機!室外機裝那麼高保養散熱鰭片也不方便!

  • @5885ronny
    @5885ronny Жыл бұрын

    Gutes 👍 Video danke

  • @piraTT
    @piraTT Жыл бұрын

    Do you install ventilation systems?

  • @antoniobellantuoni5452
    @antoniobellantuoni54522 жыл бұрын

    Bravi colleghi...saluti da italia

  • @nkboys781
    @nkboys7812 жыл бұрын

    Super work

  • @jaideepsethi4278
    @jaideepsethi42782 жыл бұрын

    Great work technicians. Come and see how indian ac technicians work ridiculously.

  • @josemariatorroglosatroyano766
    @josemariatorroglosatroyano7662 жыл бұрын

    Buenas noches que lastima de hechar a perder la fachada del edificio poniendo los compresores ahí está muy fácil subirlos al azotea de la vivienda y el sacar los tubos de la línea de frío por el lado de la derecha como que no es lo más correcto.

  • @alexsalazar5028

    @alexsalazar5028

    Жыл бұрын

    Por la izquierda es un poco mas tardado Pero es mas facil para desmontar La unidad en caso de necesitar mantenimiento

  • @trytodosm
    @trytodosm Жыл бұрын

    pro,nice teamwork

  • @escuelacerogrados
    @escuelacerogrados2 жыл бұрын

    Do you recover refrigerant when you cut the line set?

  • @peterantos9449

    @peterantos9449

    Жыл бұрын

    Need job ac am ac mechanic plis

  • @242topboss
    @242topboss Жыл бұрын

    Nice work , Love it … where did you purchase work shirts from?

  • @Hvactoolmakingideas
    @Hvactoolmakingideas2 ай бұрын

    Very nice job....

  • @higorguimaraes8508
    @higorguimaraes8508 Жыл бұрын

    La tubulacion no está curta?

  • @tamilarasan-gm1lr
    @tamilarasan-gm1lr2 жыл бұрын

    Perfect finishing

  • @SaimKhan-if4fd
    @SaimKhan-if4fd Жыл бұрын

    Nice work

  • @cephasabani2227
    @cephasabani2227 Жыл бұрын

    Good work sir

  • @jjbsrefairconservices3100
    @jjbsrefairconservices31002 жыл бұрын

    Good luck and God bless

  • @zambalisticofficialtv4615
    @zambalisticofficialtv4615 Жыл бұрын

    Why do they install the aircon next ton the window and doors.

  • @fatihgul77
    @fatihgul77 Жыл бұрын

    All sides of the house filled with compressors(ugly view), and their noise will disturb you all the time. Don't like split AC. Is not it possible to put compressor on the top of the home and use only one central compressor? 🤔🙄

  • @msbaglobalengineering
    @msbaglobalengineering2 жыл бұрын

    Good job

  • @manueld.3982
    @manueld.39822 жыл бұрын

    Why don't you put the external machines on the roof, where you don't see them.?

  • @haniffhaniff5764
    @haniffhaniff57642 жыл бұрын

    I need to lift my sinking house but my outdoor unit is placed on the ground. Do I absolutely need to decommission the outdoor unit before lifting the wall? I only need to lift the wall by 7cm or max 10cm. Can I just lift the outdoor unit slowly as I lift the wall?

  • @user-ig2op3vw6m

    @user-ig2op3vw6m

    Жыл бұрын

    Надеюсь google translate поможет тебе прочесть. Если позволяет длинна медной трубки, то ты можешь аккуратно перенести его выше, лучше делать это с напарником, но лучше вызови профессионалов .

  • @rodrigobritos7342
    @rodrigobritos7342 Жыл бұрын

    Terrible laburo lo único que faltó o no grabaron fue el vacío al equipo

  • @magolegend4985
    @magolegend4985 Жыл бұрын

    The copper tube is below 10ft. which is causing a substandard flow of refrigerant...thats not good for the aircon unit.

  • @cephasabani2227
    @cephasabani2227 Жыл бұрын

    Wow I just need where someone is installing

  • @PTBS_Ortega
    @PTBS_Ortega Жыл бұрын

    Sieht schob nice aus. Aber warum nicht auf‘s Dach mit den AG‘s?

  • @ivan-qb5fd
    @ivan-qb5fd2 жыл бұрын

    Poco más y conectan directamente la tubería que viene del Split la compresor, a eso se le llama ahorrar tubería y además por el lado derecho en vez de por la izquierda para posibles averías y mantenimientos...

  • @JeffersCoco

    @JeffersCoco

    Жыл бұрын

    El caso es llorar

  • @tolgacoban5411
    @tolgacoban5411 Жыл бұрын

    It is recommended to use at least 3 meters of pipe. Why didn't you use it?

  • @julioalvarez6683
    @julioalvarez66832 жыл бұрын

    I want to see a video of multiple zone installations

  • @rajbiswas1762
    @rajbiswas17622 жыл бұрын

    Very good work 👍

  • @jon3862
    @jon3862 Жыл бұрын

    Looks like professional

  • @Ghostriderz911
    @Ghostriderz9112 жыл бұрын

    Arent you supposed to have at least 10ft of lineset? Also not a fan of suspended condensers

  • @maxwellpsilva
    @maxwellpsilva2 жыл бұрын

    One observation: the copper tubes between evaporator and condenser less than 3 meters and connection out side.

  • @65416546513213513213

    @65416546513213513213

    Жыл бұрын

    pense en lo mismo

  • @darkfrost999

    @darkfrost999

    Жыл бұрын

    for some ac it can work at 2 meter minimum, but this is less than that, it's about 1.5 meter i dont know is it ok for the ac or not

  • @princehlengsizwesayi547
    @princehlengsizwesayi5478 ай бұрын

    Not happy on the isolator under the outdoor unit Heating mode water drip what's next

  • @nicklaurencemanangan778
    @nicklaurencemanangan778 Жыл бұрын

    Why breaker is installed below the condenser? not beside..

  • @lookatmr.lipkiss3349
    @lookatmr.lipkiss33492 жыл бұрын

    What are those in outlet box ?

  • @welitonbruscato8188
    @welitonbruscato81882 жыл бұрын

    Olá amigos, ótimo trabalho parabéns. Só uma dúvida, midea não tem um mínimo de Tubulação para ser executado a instalação.? Forte abraço amigos trabalho de vocês é excelente parabéns

  • @micboy22

    @micboy22

    2 жыл бұрын

    Cara Pensei a mesma coisa duvido que ali tenha 3 metros mínimo

  • @welitonbruscato8188

    @welitonbruscato8188

    2 жыл бұрын

    @@micboy22 tem 50 cm 😂 😂 😂 😂 mas...

  • @rodrigooliveira5034

    @rodrigooliveira5034

    2 жыл бұрын

    Outro detalhe que achei incoerente é essa tubulação sendo curva 90⁰ após atravessar a parede na prática roda vez que for necessário retirar o aparelho para preventiva terá que desfazer essa curva o que num futuro não tão distante causará a quebra da tubulação,pelo menos eu não gosto de instalar dessa maneira

  • @eng.paulocesar1524

    @eng.paulocesar1524

    2 жыл бұрын

    Uma das piores práticas de instalação, pensando em garantia do equipamento e manutenção... instalação sem respeitar a distância mínima, e ainda dobra o tubo da maquina pra fora, numa manutenção precisa desinstalar o equipamento e ainda corre o risco de trinca na tubulação da evaporadora, muito ruim, pensando em acabamento não a o que se discutir, mas qualidade técnica ai... é 0.

  • @user-is8qh7ue7e

    @user-is8qh7ue7e

    Жыл бұрын

    @@rodrigooliveira5034 можно за паять

  • @fanismitsios2450
    @fanismitsios24505 ай бұрын

    Hello, how long did it take to install both air conditioners

  • @terrysookhoo2528
    @terrysookhoo25282 жыл бұрын

    Its been years I haven't see trunking like those

  • @arengineeringyasirfazalcoolone
    @arengineeringyasirfazalcoolone Жыл бұрын

    Good working

  • @stefanoferri5850
    @stefanoferri585017 сағат бұрын

    There is no minimum 3 meters of copper pipe? Work no good

  • @cosimosantoro2994
    @cosimosantoro2994 Жыл бұрын

    I manometri abbiamo visto ma nn abbiamo visto cm avete fatto il vuoto all'interno dell'impianto

  • @mariusztom2899
    @mariusztom2899 Жыл бұрын

    What model of air conditioning is it ?

  • @pradeepshetty2911
    @pradeepshetty29112 жыл бұрын

    Sorry brother wrong installation. You should make that hole in left side of indoor unit wall . You only thinking about installation, what about future servicing , if we need to remove ac again we have to break the wall again.

  • @ijazghani312
    @ijazghani3122 жыл бұрын

    Isolater switch should be away from outdoor unite because if you wash the unite the water will effect the switch. Safety first

  • @MarcelHVAC

    @MarcelHVAC

    Жыл бұрын

    no

  • @electricaloneonone

    @electricaloneonone

    Жыл бұрын

    That depends if your isolater switch is waterproof or not 😉

  • @richarda.valdes1197

    @richarda.valdes1197

    Жыл бұрын

    It’s in a wheather proof box that’s designed to prevent moisture from affecting the inner works.

  • @richarda.valdes1197

    @richarda.valdes1197

    Жыл бұрын

    I’d like to know what the customers have to say about this brand ?

  • @nazelmenesisjr1620
    @nazelmenesisjr16202 жыл бұрын

    Why like that always outside flare nut defficult miantenace for do general service..install very easi maintenance problem

  • @dhirajdeshmukh3853
    @dhirajdeshmukh3853 Жыл бұрын

    Which drill machine used

  • @dadosdados47
    @dadosdados472 жыл бұрын

    Without oil trap and 3m steel pipe and without vacuum pump?why?

  • @hanghad7645

    @hanghad7645

    2 жыл бұрын

    The lines come prefilled with refrigerant

  • @mountainklima5602

    @mountainklima5602

    2 жыл бұрын

    you dont need oil traps for r410 unless the 2 units are very high apart

  • @dadosdados47

    @dadosdados47

    2 жыл бұрын

    @@mountainklima5602 ,if inside unit is under from the outside is nessesary oil trap for the machine to work good for long time.this will have problems after years

  • @mountainklima5602

    @mountainklima5602

    2 жыл бұрын

    @@dadosdados47 Because R-410A and POE oil mix so well together, oil-trap installation is generally not required on R-410A systems. However, technicians should always be sure to seal refriger- ant lines by crimping them closed and brazing them if they will be exposed to the atmosphere for any length of time.When an HVAC system uses POE (Polyolester) oil, which is typical of current R410a systems, suction oil traps are not required* because POE is miscible in R410a in all phases (liquid, saturated liquid and vapor)

  • @dadosdados47

    @dadosdados47

    2 жыл бұрын

    @@mountainklima5602 in your world these maybe exists,not mine friend!

  • @EsdrasCirqueira
    @EsdrasCirqueira2 жыл бұрын

    Show de instalação ficou top de mais

  • @daibe
    @daibe Жыл бұрын

    So good

  • @uio86a
    @uio86a Жыл бұрын

    Which country? The sky is so pretty

  • @eminbey3382
    @eminbey3382 Жыл бұрын

    Selamlar herkese hocam sağolasın güzel bilgi

  • @lugal3193
    @lugal3193 Жыл бұрын

    Why not multisplit?

  • @petertoth1808
    @petertoth1808 Жыл бұрын

    good work.what the flexible air conditioner channel?thx

  • @maestrovso
    @maestrovso Жыл бұрын

    Single zone systems are the easier to install. Even a child can do it. Try installing a multizone like one that supports up to 8 IDUs. I am a homeowner and just done installing a 5 tons LG multizone, in a 4000 sq ft commercial steel building that is my hobby garage. I don't trust any professionals. I bought my first mini split back in late 90s in US when there was none other brand beside Mitsubishi Mr. Slim. Today, LG is way ahead.

  • @johnfalcones9463
    @johnfalcones9463 Жыл бұрын

    Hi bro , where it’s the compay ?

  • @eletrificandofrio3196
    @eletrificandofrio31962 жыл бұрын

    Show 👏👏👏

  • @emmanuelcolli9458
    @emmanuelcolli9458 Жыл бұрын

    Lo demas me encantó suoer bien

  • @masudvilla9683
    @masudvilla9683 Жыл бұрын

    All the best done good job 👍

  • @localflorida2201
    @localflorida22012 жыл бұрын

    The electric box right under the unit where condense... very smart..🤭🤭. Another deficiency. Warranty avoid.

  • @naushadahmed05
    @naushadahmed05 Жыл бұрын

    how to service outdoor if ur ac power box under outdoor 😇 and conditions minimum 3 metres coper pipe...😂

  • @cristianfondati7432
    @cristianfondati7432 Жыл бұрын

    Porq le sacan el frente y el deflector en tantisimos aires colocados por mi nunca hice eso me parece muy tonto

  • @cookingwhitme6444
    @cookingwhitme6444 Жыл бұрын

    Apologies, behind the outdoor unit need to hawe one circle ⭕️ and then you conekt the instalation.

  • @fohat687
    @fohat6872 жыл бұрын

    God Job Boys! 👍

  • @pcgtt342
    @pcgtt342 Жыл бұрын

    Todas situaciones ideales. ( FÁCIL ACCESO). Muy BIEN igual.

  • @ZildjianNice

    @ZildjianNice

    Жыл бұрын

    yo dije lo mismo, igual hay que tener en cuanta que ellos solo quieren mostrar la calidad de su trabajo.

  • @rahathasan1035
    @rahathasan1035 Жыл бұрын

    I need this drill machine and need round wall bit

  • @queeneman2867
    @queeneman2867 Жыл бұрын

    Very good work ♥️

  • @5885ronny

    @5885ronny

    Жыл бұрын

    Gut 👍

  • @roypjohno8118
    @roypjohno81182 жыл бұрын

    Super Coper pipe Covering

  • @peppermeat8059
    @peppermeat8059 Жыл бұрын

    is this for like a rent home?

  • @BenTchissoumbou-dj6yb
    @BenTchissoumbou-dj6yb Жыл бұрын

    Très bon

Келесі