MiCOM P127 Over current and Earth Fault Settings

Ғылым және технология

MiCOM P127 Over current and Earth Fault Settings
‪@TechnicalManas1‬
sitmanas95@gmail.com
Instagram ID (for call & DM) - manas_shit_123

Пікірлер: 25

  • @electricalwithraja7110
    @electricalwithraja71102 ай бұрын

    Manas is not a name...he is a brand❤😊

  • @اسماعیلقاضی
    @اسماعیلقاضی8 күн бұрын

    Good job

  • @surendrakverma555
    @surendrakverma5552 ай бұрын

    Very good. Thanks 🙏

  • @shantanumajhi5408
    @shantanumajhi5408 Жыл бұрын

    Wholesome discussion... Expect more such videos

  • @TechnicalManas1

    @TechnicalManas1

    Жыл бұрын

    Thank u bro.... Keep support ♥️

  • @navinrattan8794
    @navinrattan879419 күн бұрын

    🙏

  • @prabhatsingh5377
    @prabhatsingh537711 ай бұрын

    Kindly make same type video lectures on ABB REF Relays also

  • @chandrus3803
    @chandrus3803 Жыл бұрын

    Thanks

  • @user-fg3uw5vu5d
    @user-fg3uw5vu5d7 ай бұрын

    please make a video for ashida adr245B relay setting

  • @Gharda-hn5ym
    @Gharda-hn5ym7 ай бұрын

    PSM 3 correct hain kya?

  • @sharukhkhan-vt7mc
    @sharukhkhan-vt7mc Жыл бұрын

    Metal detector maintenance what to check.

  • @prabhatsingh5377
    @prabhatsingh537711 ай бұрын

    If CT Ratio is 200/5 then whats the value of In ?

  • @arshadhussein6918
    @arshadhussein69184 ай бұрын

    Zabardast lecture

  • @TechnicalManas1

    @TechnicalManas1

    4 ай бұрын

    Thank u. Share as much possible

  • @arshadhussein6918

    @arshadhussein6918

    4 ай бұрын

    Kindly upload other relays presentation in detail.

  • @arshadhussein6918

    @arshadhussein6918

    4 ай бұрын

    Your phone number please

  • @varungautam4289
    @varungautam42899 ай бұрын

    Sir please clear video banaaye

  • @jims9916
    @jims99163 ай бұрын

    You said 1*IN means if CT ratio is 200/1. Then 1*200. In the CT ratio is 200/5 Then?

  • @TechnicalManas1

    @TechnicalManas1

    3 ай бұрын

    200/1 = 200. If CT ratio 200/5 then 200/5=40. So at that time it would be 5x40

  • @jims9916

    @jims9916

    3 ай бұрын

    @@TechnicalManas1 Thanks

  • @salamkadhim6949
    @salamkadhim69496 ай бұрын

    فعل خاصية الترجمة

  • @aitazazahsanofficial
    @aitazazahsanofficial10 ай бұрын

    0.5xIn what is total current if I multiply it is 100 amp?Will the relay trip on hundred amp

  • @TechnicalManas1

    @TechnicalManas1

    10 ай бұрын

    No if your full load 100 A, it will tripped at 50 A

  • @prabhatsingh5377
    @prabhatsingh537711 ай бұрын

    If CT Ratio is 200/5 then whats the value of In ?

  • @TechnicalManas1

    @TechnicalManas1

    11 ай бұрын

    What is your full load Ampere?

Келесі