Maximum distance between two columns | Column size and steel details for G, G+1, G+2, G+3 | column

Dear Viewers,
In this video, I have explained about, 'Maximum & minimum distance between two columns for residential building.
I have also explained about what should be the size of column for residential building that is for G, G+1, G+2, G+3 storey buildings.
In addition to this, I have told you how many number of bars to be provided for each type of column and of what size.
We knew that, Columns are the compression members of a building structure and plays an important role in transferring load from super structure to sub structure.
#columndistance
#steeldesign
#columnsize
1.basic knowledge for civil engineers
2. maximum and minimum distance between two columns
3. size of column
4. types of column
5. steel used in column
6. tips and technical terms for civil engineers

Пікірлер: 36

  • @venkateshguttedar7020
    @venkateshguttedar70203 ай бұрын

    Good 👍

  • @KarthiKeyan-wd1lk
    @KarthiKeyan-wd1lk Жыл бұрын

    Very good.

  • @addisawelachew1988
    @addisawelachew19885 ай бұрын

    Great knowledge of you ❤ Thank you

  • @shylusupdates

    @shylusupdates

    5 ай бұрын

    Thank you ☺️

  • @soundharyadhanasingh3621
    @soundharyadhanasingh3621 Жыл бұрын

    👍👍

  • @NodenRwek-dv4dc
    @NodenRwek-dv4dc4 ай бұрын

    Thanks

  • @sowmiyakutty5424
    @sowmiyakutty5424Ай бұрын

    Thankyou very much mam it is really very useful mam

  • @shylusupdates

    @shylusupdates

    Ай бұрын

    Thank you 🥰

  • @stargategoku
    @stargategoku Жыл бұрын

    Thankd for.posting

  • @shylusupdates

    @shylusupdates

    Жыл бұрын

    Thank you for your comment ☺️

  • @Dinesh-ck2ic
    @Dinesh-ck2ic Жыл бұрын

    Superb explanation madam 🙏

  • @shylusupdates

    @shylusupdates

    5 ай бұрын

    Thank you☺️

  • @richardolanochannel6353
    @richardolanochannel635311 ай бұрын

    Nice

  • @shylusupdates

    @shylusupdates

    11 ай бұрын

    Thank u❤️

  • @Adjetetyfio-sd7cr
    @Adjetetyfio-sd7cr9 ай бұрын

    ❤🎉

  • @vikramramachandruni4854
    @vikramramachandruni485415 күн бұрын

    For 30X60 slab can go for end to end pillera and columns? I mean no pillers in the middle. Only at end of 30 feets and for 60 length we can have 6 or 8 kind. If so what would be the cost chnage. I mean wanna construct a small apartment with commercial stule of pillars with no pillers in the middle

  • @sridharsahoo489
    @sridharsahoo48923 күн бұрын

    Good morning mam Could u say 16 feet continuous beam first floor g+2 residential building reinforcement details .thanks

  • @skyblue4548
    @skyblue4548Ай бұрын

    Dear I have subscribed your channel.

  • @shylusupdates

    @shylusupdates

    Ай бұрын

    Thank you 🥰

  • @nammu20032004
    @nammu200320046 ай бұрын

    Awesome explain Can you please vedio for size of beam & steel details

  • @shylusupdates

    @shylusupdates

    6 ай бұрын

    Sure Sir❤️ Keep Watching

  • @jaiprakashgayatrijvpolavar6459
    @jaiprakashgayatrijvpolavar645917 күн бұрын

    Good Evining mam. We are planning a G+2 residential house on hard strata. We will provide 9"x12" columns. The maximum span distance is 12 feet, and the minimum distance is 6 feet. Is this sufficient? Please clarify.

  • @Propertysales-vd1jg
    @Propertysales-vd1jgАй бұрын

    Can we use 14" X 9" column for G+1 structure with 16feet span and 4 nos of 16mm and 2 nos of 12mm rod?

  • @57-buyamayumsirajur78
    @57-buyamayumsirajur78 Жыл бұрын

    Hello madam my house is g+2 of footing 4.5 ft depth column size is 10×12 inc of 6 nos of 12 mm and 2 nos of 16mm beam span is 9 ft 10 f t n 11 ft only but tie bar is 6mm .Is my house safe in this condition

  • @VijeethSir
    @VijeethSir Жыл бұрын

    Hi bro, this is Vijeeth. I have a small doubt regarding building safety. We built G+1 building in a 1000sq feet plot (100sq yards)in 2011! Now we added a floor and a pent house on top of it. Which is G+2 and a pent house slab! There are 9 columns of 9x12 inches cross-section! We used 4 bars of 16MM, 2 bars of 12MM in ground floor and footing. And 6 bars of 12MM in rest of the floors. Now my question is - will it be structurally safe? I tried to run analysis but I lost touch in it! What is your opinion?

  • @shylusupdates

    @shylusupdates

    Жыл бұрын

    Dear Vijeeth Michael, If your house is away from earthquake zone areas & railway track, your structure is more safe for what you have provided 👍🏻

  • @vigneshm9770
    @vigneshm9770 Жыл бұрын

    Madam, For G+1 we have planned to use 9" * 9" columns with 12MM Tata Tiscon 550SD. Is this safe or will this create problem in future. We don't have any plan to extend this building further. Please respond, thank you.

  • @shylusupdates

    @shylusupdates

    Жыл бұрын

    Always choose rectangular column. Rectangular column is chosen for uniaxial and biaxial loading because the rectangular shape reduces the moments in lateral directions and long column mainly fail by buckling so there is need to reduce the deflection in lateral direction. Choose atleast 9" x 15" or 9" x 18" .

  • @jagannathpatra6866
    @jagannathpatra686611 ай бұрын

    Madam g+2 ka aap bole 12X12 inch colum lekin ye offset ayeg column ko 9 inch ka hisab se boliye

  • @user-el4bw7fo5g
    @user-el4bw7fo5g3 ай бұрын

    Beam. G +2

  • @Nagar_Boy
    @Nagar_Boy3 ай бұрын

    Hi didi ❤

  • @shylusupdates

    @shylusupdates

    3 ай бұрын

    Hello 💚

  • @Nagar_Boy

    @Nagar_Boy

    3 ай бұрын

    @@shylusupdates didi aap konsi city se hai

  • @globalmastercadd4427
    @globalmastercadd44272 ай бұрын

    I THINK G+2 STORIEY COLUMN 6 BARS 16MM SHOULE BE USE

  • @janjya

    @janjya

    2 ай бұрын

    If Span of column more than 18 feet

  • @ArunKumar-dk8wd
    @ArunKumar-dk8wd Жыл бұрын

    Free engineering quotation pdf send me mam I also send mail id and screenshot also

Келесі