Liftmaster Logic 5 Control Board - Overview

Liftmaster Logic 5 Control Board - Elite Series Commercial Door Operators
New Features - Security + 2.0 and MyQ
Standard features:
MRT (Max Runtime) - Limits motor run time to reduce chance of door and operator damage.
MID (Mid-Stop) - Stops door mid cycle normally and allows full open when needed.
TTC (Timer To Close) Automatically closes door after opening.
MAS (Maintenance Alert System) Programmable warning when maintenance is due.
Expansion Ports (2) - For adding additional safety device(s) and /or warning device(s)
**Under no circumstance should untrained individuals attempt adjustment or inspection of commercial door operators. Always consult your garage door professional for service needs.**
Liftmaster Logic 5.0 Commercial Door Operators Elite Series Overview - • Liftmaster Logic 5.0 C...
What Is Liftmaster Logic 5.0 Security + 2.0 and MyQ - • What Is Liftmaster Log...
How To Select A Commercial Door Opener - • How To Select A Commer...
First Class Garage Door - Chicagoland
www.fcgdoor.com/

Пікірлер: 70

  • @garagedoorgenius
    @garagedoorgenius Жыл бұрын

    Great explanation dude! 👊🏼

  • @luigitouchette421
    @luigitouchette4212 жыл бұрын

    Where is the learn button on that ?

  • @Chen-sAuto
    @Chen-sAuto Жыл бұрын

    Hello, we use this logic 5 for our condo building, one of tenant lost his receiver with his vehicle both stolen, how could we reprogram and modify the dip code on this machine? thanks

  • @jakerybakowicz9278
    @jakerybakowicz92782 жыл бұрын

    How would I program a Homelink in my car to open this door control system? Is there a Learn button?

  • @marciasage879
    @marciasage8793 жыл бұрын

    When I open the cover of my opener like this one there is 2 yellow lights that stay on in the middle of the board and one yellow light on the side of board that’s flashing , I was cleaning my ceiling and after that it doesn’t work

  • @firstclassgaragedoor6471

    @firstclassgaragedoor6471

    3 жыл бұрын

    I would need more specific information about which lights are on and how many flashes your getting from which lights. I would check any wiring that may be running across the ceiling that could have been disturbed.

  • @fukushimareactor4
    @fukushimareactor42 ай бұрын

    How to connect to Crosslink

  • @firstclassgaragedoor6471

    @firstclassgaragedoor6471

    Ай бұрын

    I'm not familiar with crosslink.

  • @kevinvalerio709
    @kevinvalerio709 Жыл бұрын

    How can I program my car homelink to garage door since this opened does not have learn or smart button? Would it be the radio button here?

  • @firstclassgaragedoor6471

    @firstclassgaragedoor6471

    Жыл бұрын

    Yes, the radio button.

  • @survivorjohnny44
    @survivorjohnny443 жыл бұрын

    I do life safety and since the doors at this location are called "smoke doors" the fire marshal wants the doors to "drop on fire alarm". You didn't mention this in your video and I haven't found a spec sheet online. Is the 5.0 capable of this?

  • @firstclassgaragedoor6471

    @firstclassgaragedoor6471

    3 жыл бұрын

    Yes, it is. These operators have a ton of additional capabilities, hard to cover all of them in one video and any fire door related repairs should be performed by a certified Rolling Steel Fire Door Technician.

  • @Sniper111994
    @Sniper1119944 жыл бұрын

    Can a floodlight be wired in? I have two liftmaster 5.0 in my shed with no exterior lighting. Was hoping be able install floodlights that will turn on/off when opening an closing the garage door to assist in visibility

  • @firstclassgaragedoor6471

    @firstclassgaragedoor6471

    4 жыл бұрын

    You could wire them through an auxiliary close limit switch. This would turn the lights on anytime the door(s) we’re not fully closed. It would require an additional limit switch for each unit and some wiring. You could wire in a timer to prevent the lights from going on during the day if it’s a concern.

  • @Sniper111994

    @Sniper111994

    4 жыл бұрын

    @@firstclassgaragedoor6471 awesome thank you!

  • @Jfowler1016
    @Jfowler10163 жыл бұрын

    Can a 893max remote be programmed for a logic 5 and if so what color button do I set it for. Thanks

  • @firstclassgaragedoor6471

    @firstclassgaragedoor6471

    3 жыл бұрын

    Yes, Yellow smart button.

  • @jasonturton2495
    @jasonturton24954 жыл бұрын

    how do I allow door to close without having to hold the close button on wall mount controls?

  • @firstclassgaragedoor6471

    @firstclassgaragedoor6471

    4 жыл бұрын

    For momentary contact to close you will need at least one monitored safety device (safety eyes) installed. If you already have a safety device connected check that it’s working properly, if so make sure your wiring type selector dial is set to “B2” - Momentary contact to open, close and stop.

  • @samsawyer5358
    @samsawyer53583 жыл бұрын

    Whenever I try to close my door. It stops after a little bit. Then after trying to close it again, it will go back by itself and try to close. I have to press stop to keep it from going all the way. Door still eventually closes. But is a massive inconvenience. Please help

  • @brad3378

    @brad3378

    Жыл бұрын

    Did you figure out the problem yet? If you haven't checked already, the system will flash fault codes on the Maintenance Alert System (MAS) indicator light. A list of fault codes is shown on the inside of the access door.

  • @ahmedelshami9898
    @ahmedelshami98984 жыл бұрын

    Hi thank you for the information Question? I'm have the same opener and I'm trying to connect kpr2000 on it in the same time I have an open button out side so what you think is the best way is to connect it to the button or to the opener and if you can instruction?

  • @firstclassgaragedoor6471

    @firstclassgaragedoor6471

    4 жыл бұрын

    Given the lack of site/application specifics, I would keep the KPR2000 separate (wire direct to operator control board). If you are using the keypad to open the door you can terminate the relay wires (Blue & Purple) to "COM" & "Open" - If you want to open and close the door with the KPR2000 wire to "COM" & "SBC" (monitored safety device required) Also make sure you have a 12-24vdc power supply for the KPR2000, the on-board power supply in the operator is 24vac.

  • @JuanIzar
    @JuanIzar3 жыл бұрын

    Wouldn't the learn button have to be used to erase any stolen remotes? What's another alternative to doing that if one or more remotes get stolen in a multi residence building?

  • @firstclassgaragedoor6471

    @firstclassgaragedoor6471

    3 жыл бұрын

    The board would need to be cleared and all remotes reprogrammed, assuming the remotes are all digital and not analog.

  • @raulgajilomo5750
    @raulgajilomo57502 жыл бұрын

    Hello we are working on this type of product start capacitor always blow up on motor. We check the motor centrifugal switch but theres no centrifugal switch inside the motor. Is the start capacitor is electronically control?

  • @firstclassgaragedoor6471

    @firstclassgaragedoor6471

    2 жыл бұрын

    What operator specifically, Model number ?

  • @jarrodmccarthy-bb3ro
    @jarrodmccarthy-bb3ro4 ай бұрын

    I’m in Jacksonville Florida and I have one that’s putting out a rpm sensor malfunction( 2 blinks ) . Do you have any recommendations?

  • @danielraymond38
    @danielraymond383 жыл бұрын

    have a liftmaster fire release system in lobby, it was beeping, battery was very old, I changed the battery but continued to beep. i need to check the voltage of the new battery or is there a set up process after installing new battery?

  • @firstclassgaragedoor6471

    @firstclassgaragedoor6471

    3 жыл бұрын

    Yes, make sure the new battery is good. What model is the release device and how old is it exactly ?

  • @sandyvonbargen4386
    @sandyvonbargen43869 ай бұрын

    Can a additional antenna be added to help pick up the Wi-Fi signal on these openers? We have 2 of these openers with a very strong signal in our newly built shop and our main internet connection is set up out here w/our router in the shop too. Often times when I am away from the shop or even in the shop it shows on the myQ app that my 2 shop doors are offline, but my third door which is our garage, is also on the same internet connection always stays online. Why am I having this problem? I would think the signal in our shop is more than plenty strong, but 9 out of 10 times it is offline.

  • @firstclassgaragedoor6471

    @firstclassgaragedoor6471

    9 ай бұрын

    Not to my knowledge. Generally we don’t get to involved with the internet side of things as that is better suited for the IT guys that do it every day. I would probably say you need a repeater or extender to get the Wi-Fi signal out to the other doors but that would be from the IT side not the operator manufacturer or installer. I think the Wi-Fi antenna on the door operator is built-in to the circuit board, the one you see on the outside of the machine is the radio antenna for the remote(s). Good luck.

  • @frankreed6121
    @frankreed6121 Жыл бұрын

    I ordered an 828LM from Amazon and received a Chamberlain CIGBU gateway. Will this work with my J501L5 Logic 5.0 units?

  • @firstclassgaragedoor6471

    @firstclassgaragedoor6471

    Жыл бұрын

    I'm not familiar with Chamberlain part numbers as we deal with Liftmaster but I would imagine it should work given that they are one and the same, except for the part numbers.

  • @luis18jimenez1992
    @luis18jimenez1992 Жыл бұрын

    How do I set the TTC to 10 minutes??

  • @shangwei5899
    @shangwei58994 жыл бұрын

    How would I install a entrapment detector?

  • @firstclassgaragedoor6471

    @firstclassgaragedoor6471

    4 жыл бұрын

    Sorry for the delayed response. Make sure you have a Liftmaster brand monitored commercial safety sensor and connect to the logic 5 board as indicated in the instructions for the sensors. You will be using terminals "LMEP" & "Com", polarity matters so check installation instructions for your safety device.

  • @erichargrave8662
    @erichargrave8662 Жыл бұрын

    Where do the sensor eyes plug up in the

  • @firstclassgaragedoor6471

    @firstclassgaragedoor6471

    Жыл бұрын

    Without more information I couldn't say.

  • @lxstangs
    @lxstangs Жыл бұрын

    What does It mean when the MAS light blinks 5 times? Thank you

  • @firstclassgaragedoor6471

    @firstclassgaragedoor6471

    Жыл бұрын

    Not sure what accessories you have or how they are wired but something is giving the operator a constant command to open, close or stop.

  • @ochoaelectric5175
    @ochoaelectric51752 жыл бұрын

    I have a short blowing a fuse what can it be the motor is ok

  • @firstclassgaragedoor6471

    @firstclassgaragedoor6471

    2 жыл бұрын

    What operator is it exactly ? Assuming the unit your working on has a brake mechanism, is the solenoid ok ? Also, the operator has a built-in thermostatic breaker or manually resettable breaker, typically that will go before the breaker/fuse in the panel. Is it on a 15 or 20 amp circuit ? Did you try swapping the breaker in the panel or is it an old fuse panel ? Not supper common but we do find bad breakers from time to time. Anything else on the circuit ? Should be dedicated for the operator.

  • @redbeardevildead3459
    @redbeardevildead34594 жыл бұрын

    How do i add a remote to this operator using that radio button?

  • @firstclassgaragedoor6471

    @firstclassgaragedoor6471

    4 жыл бұрын

    Here is a link to the Logic 5 installation manual, www.controlledproducts.com/customer/docs/skudocs/J501L5_Installation%20Manual.pdf - see page 38 for remote control programming instructions.

  • @frankmartens20
    @frankmartens203 жыл бұрын

    How do you program the open and closed position?

  • @firstclassgaragedoor6471

    @firstclassgaragedoor6471

    3 жыл бұрын

    These units have physical limits. The open and close limit nuts are physically adjusted to set the travel parameter.

  • @franklynoutten6840
    @franklynoutten68404 жыл бұрын

    Need help with q206 micro robo series

  • @firstclassgaragedoor6471

    @firstclassgaragedoor6471

    4 жыл бұрын

    Whats the issue?

  • @matts3710
    @matts37103 жыл бұрын

    Can I program a timed close as well as close the door with a remote? If so how do I do it?

  • @firstclassgaragedoor6471

    @firstclassgaragedoor6471

    3 жыл бұрын

    You would need to program a 3-button remote (open - close -stop) and set board to wiring type TS or wire an external timer and use wiring type B2.

  • @matts3710

    @matts3710

    3 жыл бұрын

    We are in a new fire station (close to you) and trying to get this to happen before the weather gets too cold. Could we talk more about this via email or phone to start?

  • @firstclassgaragedoor6471

    @firstclassgaragedoor6471

    3 жыл бұрын

    @@matts3710 Sorry for the delay. If you are still working on this give me a call to discuss.

  • @josemendietta2404
    @josemendietta24043 жыл бұрын

    I working on a similar system have 117 volts but no 24 on screws where is the transformer mod no H501L5R. E 79930 you think that would be the problem with no 24 v

  • @bsuv1

    @bsuv1

    3 жыл бұрын

    Transformer is located behind the logic board

  • @josemendietta2404

    @josemendietta2404

    3 жыл бұрын

    Or a fuse somewhere?

  • @firstclassgaragedoor6471

    @firstclassgaragedoor6471

    3 жыл бұрын

    @@josemendietta2404 The only "fuse" is a thermo breaker inside the motor. It "breaks" when the motor over heats and automatically resets itself when the motor cools down. Do you have 110/220v on the transformer high side ?

  • @josemendietta2404

    @josemendietta2404

    3 жыл бұрын

    Fixed it but now I have a logic 4 that has a relay b problem trying to open and close the door

  • @josemendietta2404

    @josemendietta2404

    3 жыл бұрын

    Logic 4 model GH7453L4

  • @joserico7539
    @joserico75392 жыл бұрын

    Why could a rolling door with a hj lift master controler could roll down even if system is shutdown (no oower))

  • @firstclassgaragedoor6471

    @firstclassgaragedoor6471

    2 жыл бұрын

    Not sue if its an H or a J model (should be an H on a rolling door) but if their is a mechanical failure in either model the door could certainly come down on its own, even with power off. Aside from an issue with the operator it sounds like the door has a broken spring(s) or the spring(s) is/are out of adjustment.

  • @charlesterry1044
    @charlesterry10443 жыл бұрын

    4 7 blinks on a LiftMaster jackshaft

  • @firstclassgaragedoor6471

    @firstclassgaragedoor6471

    3 жыл бұрын

    Check the safety eye wiring for a loose or dirty connection (wire nut connections without dielectric grease are bound to fail in my experience) we use 3M water tight connectors for solid wire connections or fill a wire nut with dielectric grease for stranded wire connections. Test eyes for proper operation, block sensors and make sure the green LED’s flash (assuming you have the CPS-U sensors). If the connections are good and eyes appear to be working, hold the close button until the door is fully closed then Open and try closing with a momentary press of the close button. If the problem persists replace photo eyes. We’ve seen commercial eyes behave as if they are working fine but are bad. We have also seen eyes that don’t blink when interrupted so at first glance they would appear to be good as the green LED indicators are on steady. I suppose it’s possible that the logic board could be bad but the new eyes would be a cheaper and more practical starting point.