Jandy Pool Heater FAULT CHECK IGN STEPS Ignition Failure & How to Prevent Premature Retirement

Тәжірибелік нұсқаулар және стиль

Jandy JXI series gas pool heater - FAULT CHECK IGN STEPS explained in this Step-by-Step Instructional Video.
Inspection Camera: amzn.to/3prttIR
Let's Make The Trades Great Again & While Giving Back To The Community:
/ channel
www.pipes4free.org
Our mission is to provide free or low cost plumbing, heating & cooling services to those in our community who can't afford to hire a professional. Mikey Pipes Philanthropy, Inc. is a IRS registered 501(c)(3c) public charity incorporated in the State of New York.
Donate on Paypal: www.paypal.com/donate/?hosted...
Check out my podcasts on Spotify: podcasters.spotify.com/pod/sh...
What’s in your Veto? Here is mine:
Veto TP-XXL amzn.to/3zX10vg
Malco 5/16" & 1/4" 6" Driver tinyurl.com/MalcoDriver
Milwaukee M12 Fuel 1/4" Impact Driver amzn.to/3I9yLfI
Milwaukee PVC cutter: amzn.to/3sbrdUc
Mini Waterproof Storage bin: amzn.to/3yfgsEv
Wiha Allen Keys: amzn.to/33ipGmb
HIKMICRO B20 amzn.to/33iGklx
Furnace Switch amzn.to/31X89PT
Milwaukee Light amzn.to/3I38Lmh
Wagos amzn.to/34QoiaU
Milwaukee Set amzn.to/33vnQOz
Torpedo Level amzn.to/3no1oOk
Crescent set amzn.to/3GtZeV8
Wiha 7 piece set amzn.to/3rkISaK
Milwaukee step bit amzn.to/3I395Bv
Flare wrench amzn.to/3noJZ8s
Ridgid 10” wrench amzn.to/3GvRnqa
Fluke non-contact tester amzn.to/31VQgAQ
Klein drivers amzn.to/3qoe21W
Knipex Wrenches amzn.to/3trzFjS
Klein 11-1 amzn.to/3tpsPLD
12” crescent amzn.to/3A0CZ6S
Gerber Gear Pocket Knife amzn.to/3foaW7I
Yellow Jacket Hand Ratchet amzn.to/3nrDgup
Need a website for your contracting business? Check out Footbridge Media for their amazing special on not only a website but SEO services for only $249/month! www.footbridgemedia.com/?ref=...
Tired of HouseCall Pro? Don't wanna be ripped off with ServiceTitan? Try ServicePal for free for 30 days! app.servicepal.com/account/si...
Check out my Uncensored channel: / mikeypipesuncensored
Oval raised silver stickers are from:
Armored Decal Company Inc.
35 Victoria St. E, Unit 9
Alliston, Ontario L9R 1T3
(p) 705-435-6665
(e) ken@armoreddecal.com
(Tell them Mikey Pipes sent you)
Please support this channel and Mikey Pipes and consider the following…
UPDATED: June 15, 2023
PIPE DOCTOR FLEX FIT HATS only $40 each shipped USPS! Or 2 for $70
Shopping on Amazon? Please use my referral link amzn.to/2PjjS4v
Sticker Requests:
Do you want a sticker to show your support of this channel? Email your request to me! mike@mikeypipes.com
Name
Address
City, State, Zip
Consider making a donation of $5.00, or ANY amount, to the postage fund! I literally mail out stickers all over the globe. I've sent stickers to HVAC guys in Afghanistan, New Zealand & all over Europe.
Donations Accepted:
PayPal: office@pipedoc.net
Venmo: @PipeDoctor
CashApp: $mikeypipesny
Zelle: office@pipedoc.net
Want to send a love letter, note or gift? Our mailing address is:
Mikey Pipes
C/O Pipe Doctor Home Services, Inc.
80 E Hawthorne Ave
Valley Stream, NY 11580

Пікірлер: 61

  • @joelthompson4801
    @joelthompson4801 Жыл бұрын

    Can we get the Amazon link for that sweet inspection camera?

  • @joelthompson4801

    @joelthompson4801

    Жыл бұрын

    @@PipeDoctor Thank you very much

  • @adamluke1289
    @adamluke1289 Жыл бұрын

    I like the pool heater videos. That sucks when a relatively new product fails - and it's usually just after the warranty expires.

  • @DaneJoshuaTree
    @DaneJoshuaTree9 ай бұрын

    Awesome. Thanks

  • @timothyharris3542
    @timothyharris35427 ай бұрын

    Could the heater exchanger be removed cleaned and pressure tested and the leak silver soldered or brazed

  • @ronaldbrosius7488
    @ronaldbrosius7488 Жыл бұрын

    The exhaust pipe! Bushes laying all over it 😂

  • @robertjoseph1592
    @robertjoseph1592 Жыл бұрын

    Here in Arizona many people use a heat pump on their pool since it can be run in heating mode during cool months (November to May) and then in cooling mode during the really hot months (July to September). I don't have one so by midsummer my pool water is about 95 degrees Fahrenheit.

  • @robertjoseph1592

    @robertjoseph1592

    Жыл бұрын

    @@PipeDoctor Yep, we actually root for hailstorms every August LOL!

  • @mattl643
    @mattl643 Жыл бұрын

    Make sure you add a corrosion resistant check valve before that chlorinator.

  • @FoxItAll
    @FoxItAll7 ай бұрын

    JXI is a 3 year heater here in Florida.

  • @Chris-ft2pq
    @Chris-ft2pq2 ай бұрын

    Add a Vera flow valve to jxi the will prevent water from moving through when not in use. I would also have a check valve between heater and sanitizer.

  • @hermankrissiaramirez4085
    @hermankrissiaramirez408510 ай бұрын

    I like how they Camouflage the equipment

  • @PipeDoctor

    @PipeDoctor

    10 ай бұрын

    Let’s have the equipment get covered by weeds

  • @realestateservicessaleshea99
    @realestateservicessaleshea99 Жыл бұрын

    You have to be very meticulous about your pool water with a pool heater, unbalanced water can be corrosive ! Thanks again for the videos. 😐👍🏻🥃🥃🍺🍺🍺🇺🇲

  • @grapplerguy2007

    @grapplerguy2007

    Жыл бұрын

    If ph drops below 7.2 yes otherwise you are high on scale. We practice lsi and csi on all pools and keep a log. Many times they try and blame pool guys. But these jandy heaters are failing sometimes well before 6 months mark. Couldn't ruin a heater from chemistry this soon even if ya tried. Jandy own manual says that allow for ph to be 6.8 and alk upwards 180ppm. It's not chemistry issue. Product issue and most likely it's electronics wiring with pressure switch or pressure switch itself. This is Also stated in the troubleshooting guide in jandy manual. Igniter has it own fault code same with flow error

  • @JoshuaPchelka
    @JoshuaPchelka2 ай бұрын

    Calcium deposits such as that are due to poor water chemistry maintenance. Once the water can not hold calcium any longer it deposits in the warmest parts of the pool/ heater and it salt cell. PH and Alkalinity need to be checked every 4 to 7 days and calcium levels monthly.

  • @j0nathan948
    @j0nathan94811 ай бұрын

    Wait so why did it go bad? What caused it ??

  • @scottmaz4063
    @scottmaz4063 Жыл бұрын

    #1

  • @brianjohnson8883
    @brianjohnson8883 Жыл бұрын

    It all has to do with water chemistry and if you only pay your pool guy $100/month don't count on it to be ideal.

  • @guillermocastillo6549
    @guillermocastillo6549 Жыл бұрын

    Low calcium hardness in the water could cause calcium build up too.

  • @donguadalucio1405

    @donguadalucio1405

    Ай бұрын

    The calcification was outside the copper coils not inside.

  • @MrBrettsb
    @MrBrettsb Жыл бұрын

    What’s the warranty on the heat exchanger?

  • @MrBrettsb

    @MrBrettsb

    Жыл бұрын

    @@PipeDoctor that will do it. I am anal about the chemistry of the pool and I keep the heater on bypass when not in use just to be safe

  • @grapplerguy2007

    @grapplerguy2007

    Жыл бұрын

    ​@@PipeDoctoranyone can say water chemistry issues. But unfortunately for those type we have gps time stamped digital logs of all chemistry.

  • @eddiew.6485
    @eddiew.6485 Жыл бұрын

    Maybe after replacing the heater, recommend they fire their landscaper 😂

  • @donguadalucio1405

    @donguadalucio1405

    Ай бұрын

    Or recommend to hire a landscaper.

  • @BeReady726
    @BeReady7264 ай бұрын

    We have a pos like this, maybe the same model, and I just got this error. It’s only a few years old. Designed to break I’m sure, bc we never did anything bad to it, barely used it actually.

  • @PipeDoctor

    @PipeDoctor

    4 ай бұрын

    Sorry for your loss

  • @user-rj9nj9ye1h

    @user-rj9nj9ye1h

    4 ай бұрын

    Same here. Exact model With same error

  • @Shadypoolguy

    @Shadypoolguy

    3 ай бұрын

    Most likely bad water chemistry, which is the cause of most heater failures. Most companies only test ph and cl levels and forget about the alkalinity levels which will eat the cooper in your pool heater.

  • @jimblack8677

    @jimblack8677

    Ай бұрын

    I take my water to Leslie at least every 2 weeks to be tested and ALWAYS FOLLOW THEIR ADVICE. The only reason these heaters fail is that they are garbage to begin with and NEVER SHOULD BE USED TO HEAT YOUR POOL WATER!!!!

  • @ronlovell5374
    @ronlovell5374 Жыл бұрын

    I see this often, most times from poor installation and wrong orientation of pool equipment. (Heater not being installed after filtration and before the electronic or cemical clorinater) and if installed correctly, no check valves in place to prevent backflow contamination. Also, with salt water pools, the cartridge type filters are junk compared to sand media filters.

  • @grapplerguy2007

    @grapplerguy2007

    Жыл бұрын

    Lmao cartridge filters better than sand. You also should use corrosion resistant check valves but even jandy stands by regular spa jandy style check valves between cell and heater Go figure.

  • @Koj2ez

    @Koj2ez

    9 ай бұрын

    D.E filters are probably the best filtration device for pools.

  • @grapplerguy2007

    @grapplerguy2007

    9 ай бұрын

    @@Koj2ez duh

  • @tylerwilliams3868
    @tylerwilliams3868 Жыл бұрын

    just wondering what the lifespan on a pool heater usually?

  • @donguadalucio1405

    @donguadalucio1405

    Ай бұрын

    5 to 10 years on residencial poosl and less than 5 year on commercial pools. JXI heaters are so bad that they last less than 4 years.

  • @damionfragoso2655
    @damionfragoso2655 Жыл бұрын

    It would kill the gardener to spray some weed killer around the pool equipment

  • @JesseDoesHVAC

    @JesseDoesHVAC

    Жыл бұрын

    Probably also kill the gardener from spraying all that poison on the earth

  • @lukepoolservice
    @lukepoolservice4 ай бұрын

    Its a manufacturing defect. They should send the customer a new heater.

  • @jimblack8677

    @jimblack8677

    Ай бұрын

    True, true, TRUE!!!

  • @shawnkauffman5537
    @shawnkauffman5537 Жыл бұрын

    "It's on the Fritz" lol

  • @RandyBarnard-yf5bw
    @RandyBarnard-yf5bw11 ай бұрын

    The installer failed to install a anti-corrosive check valve between the heater in the chlorinator and that is why the heat exchanger failed

  • @JesusismySavior28

    @JesusismySavior28

    7 ай бұрын

    Hi Randy with Fluidra. You are 100% correct. I’ve seen installers not adding one in most cases.

  • @kellytaddeo3574
    @kellytaddeo357410 ай бұрын

    Why can't the hot surface ignitor just be replaced?? It's a replaceable part you can purchase.

  • @PipeDoctor

    @PipeDoctor

    10 ай бұрын

    It can

  • @universaldonor3100

    @universaldonor3100

    6 ай бұрын

    if the problem were a bad surface ignitor only, sure; but, the exchanger is bad and will only corrupt a new HSI....

  • @kens.3729
    @kens.3729 Жыл бұрын

    Looks like the Homeowner allows a “Natural Prairie” around Pool Equipment. State DOT’s do that in Highway Right-of-Ways to Avoid Grass Cut Mtce. 🤪👎

  • @STXVIEC
    @STXVIEC Жыл бұрын

    classic jandy fail. Happened to me 2 times. Never again lol

  • @STXVIEC

    @STXVIEC

    Жыл бұрын

    @@PipeDoctor First unit (JXI-400) was installed March 2020 with pool instillation & Failed September 2020. Then replaced through warranty. Second one was from September 2020- June 2022. 2 years old & no longer under warranty. Both times were faulty heat exchangers. Water chemistry was always on point!

  • @scottmaz4063
    @scottmaz4063 Жыл бұрын

    Looks like rock salt

  • @chuckquinn8026

    @chuckquinn8026

    Жыл бұрын

    Salt water pool? 🤷‍♂️

  • @kens.3729
    @kens.3729 Жыл бұрын

    That Equipment doesn’t look Cheap so Why does it DIE in three (3) years ? Breach of Heat Exchanger ? Absolutely Unacceptable and Ridiculous. 🤪👎

  • @cravenmorpus
    @cravenmorpus9 ай бұрын

    The reason the heater is wired in with the pump is bc you want the heater to turn off with the pump, otherwise you could catch the heater on fire or burn the heater and other items up. Also, the calcium build up is bc it's a salt pool and they most likely don't pay attention to their pH and calcium levels like they should.

  • @Mike-rm7vf
    @Mike-rm7vf Жыл бұрын

    That’s gotta be made by Raypak. Pure junk.

  • @Chris-ft2pq
    @Chris-ft2pq2 ай бұрын

    5yr warranty on heat exchanger fyi

  • @PipeDoctor

    @PipeDoctor

    2 ай бұрын

    Wrong

  • @Splattertube
    @Splattertube4 ай бұрын

    A plumber who thinks he knows pool equipment.

  • @PipeDoctor

    @PipeDoctor

    3 ай бұрын

    Yes, factory trained b!tch

  • @Egittv
    @Egittv2 ай бұрын

    You talk too much but you didn’t show what is the solution 🤦🏻‍♀️🤦🏻‍♀️🤦🏻‍♀️ if do we need to replace that ignition or we need to clean that inside the heater???!🙄🙄🙄

Келесі