Installation Network data Server Rack And cable management 27U cabinet Best Setup For Office or home
Ғылым және технология
Buy Me A Coffee ☕ Here 👇
www.buymeacoffee.com/zhaider299w
how to install networking setup for school colleges and offices 27U server rack installation from 0% to 100% a huge setup for office 270 points for internet camera WIFI telephone
#hikvision #dahua #ipcom #aicontent #aico #dlink #hdd #tplink #webb
#cctv #networking #network #internet #access control #cctv camera #cable management #unbox #intercom #broadcast system #access point #electric door lock #wifi #HDMI #hard disk # internet switch management #time attendance
how to install
Пікірлер: 184
It’s great to see these cabinet products in action in the field, thank you for your great work😇
Neatness is ok but I am a fan of shorter Patch cables. The setup in the rack seems like it could be improved on to have shorter patches which in my experience is more serviceable.
To every Low Voltage Electrician? Watching this is pure harmony. However, I would negate the Zap Straps for Velcro. But I would be a Liar if I said that I did not too do the same. Instead of Labels? I just use a Sharpie. Hard to get a Punch down tool in those tight space, so glad you got it done in place.
@naturefuturetech
6 ай бұрын
🤗🤗🤗
@patrickd9551
3 ай бұрын
I would also replace the hard patches with keystones. Much easier to move around (which I've done a few times myself). The added cost is negligible compared to the hours paid.
Just small Tip: Permament Labels -> First tie over the cable and next bend over the label so that it will additionally secure label from falling of as the cable part will be glued from both sides :D
To those who mention the labeling + patch/switch arrangement: I suspect that this was existing wiring they had to deal with, identify and clean up. Or who knows. And I suspect they needed very specific patch ports to go to specific switches, so the paths are actually all different, it just looks clean. You can't always just jump patch ports 25-48 to switch ports 1-24 and vice versa. Then you have to choose if you keep your patch panels linear (to serially match the wall ports), or patch by function. I'm debating that in my upcoming install though I prefer the latter. Seemed like they possibly did the former.
@cedricwilliams641
2 ай бұрын
Yeah…from the start of the video, you could see that it was preexisting cables. They cut them and toned them out
Smaller cabinet, have deeper cable managers when using longer patch cables, rather than feeding everything to the side. Looks nice, but defeats the purpose of a cable manager, and screws anyone trying to feed wire through in the future. But looks ok.
amazing work! My only comment is that its much faster , cheaper and easier for the next guy that may come to do a work in there to use the standard - patch panel , switch , patch panel. Working this way its much more serviceable and you can use much smaller patch cables.. Other than this amazing!
order, cleanliness, results in a beautiful job, well done, congratulations!
@naturefuturetech
8 ай бұрын
Thank you 😊🌹
Pretty nice. I am not sure why you would go with smaller port number switches, but maybe the PoE limits were the cause. I think spending a little extra on something with good forced cooling, dual power supply, and 50 ports is way to go almost always, even in smaller setup. It makes less mess, and gives you flexibility later.
Great organization congratulations
You have my full respect!
@naturefuturetech
Жыл бұрын
Thanks 👍🌹
Great work! Respect and +100 points for proffesionalism.
@naturefuturetech
Жыл бұрын
Thanks🌹for your support
@AjayKumar-bz5yj
11 ай бұрын
Ajay
First use Punch Down Tool, its gonna make your life easier. Second and more important, you are untwisting pairs a bit to much. Its probably gonna pass for cat6, but still, just do it the right way. Also that patch panel is awful, i understand sometimes you have to work with what you are given, but you have nothing to secure your cable to...Otherwise, its very decent job, i would personally go up and then come down on the other side with cables just to leave enough for equipment shuffling in the future (and that's gonna happen for sure). Respect for cable labelling.
@alxavz18
3 ай бұрын
I noticed the same thing, too much untwist at patch panel, and i don't think it will certify for cat6
Awesome video, Mate! F'real. I'm going to be doing this for the first time very soon and I feel like after punching down the copper, the little ends will get in hard to clean places, and I'm thinking there must be a cool strategy to ensure that none of those little pieces end up being left behind. Like maybe you could get really good at aiming the debris where you want it to go, or idk. I don't know why I focus on little things like this that aren't really a big problem haha.
@user-io4rn6rk9h
7 ай бұрын
应该用光纤局域网加楼层内路由器😂😂😂
That is one hell of a build out I'm jelly lol.
Great job turning chaos into order.
I am new in this kind of work, and the setup looks very neat and nice, but isn’t it better to have the related patch panels and switches be closer to each other, that way you only use a small cat6 cable to connect them right above each other, that way it will be easier for maintenance later; for example if there’s a problem with one specific cable with this kind of setup you might need to remove lots of cables so you can reach the specified cable but when the switch and panel are right above each other only a small cable needs to be removed or changed, i don’t know what do you think?
excellent! marvelous
Very zen and satisfying video for us tech people
@morganmcgary921
9 ай бұрын
Curious though. For cleanliness wouldn't it have made more sense to run the cat5 through the holes in the cable management slot and feed them up or down through the grooves so you could tidy up all cabling in the back instead of the front?
What I don't understand is that you're using shielded cables and unshielded patch panels.
@TheRonsmans
7 ай бұрын
but otherwise neatly installed.
Easy work. I did it 1000+ times. Prefer to use shorter patch cables.
The my fellow peep's is a work of art!! I do have a question: Did the casters ever come off? If not that would give me worry.
Really impressed with your work wish to work with you
Well done 👍
I actually learnt a few things from this vid, thanks
@naturefuturetech
Жыл бұрын
❤️🌹❤️
How I wish to learn from you guys 👍👍
nice and beautiful work
@naturefuturetech
8 ай бұрын
🌹❤️🌹
Harnessing lvl is 10% skilled.. First thing u need to do in elv works is the design and cabling skills.. this is begginer lvl.. Using cable comb for harness Velcro Tagging Design lvl,
great work you have graet thanks
@naturefuturetech
9 ай бұрын
🌹💕🌹
May look pretty but not to Structured Cabling Standards. You don’t use Tie Wraps (aka, zip ties) on data cables. It distorts the twists in the cable causing attenuation and crosstalk. When you run the cables where they run parallel tie wrapped together it causes alien crosstalk (look it up). Is the bay grounded? Different categories of Patch Panels. Different manufacturers of patch panels with some CAT5E and some Cat6. Too much untwisted in the termination and not using the proper punch down tool. Look up BISCi standards and patch panel manufacturers standards. Belden, Lucent, AMP, and Panduit all have installation standards available online.
I love it
Great work guys
@naturefuturetech
7 ай бұрын
Thank you so much 😀
Muito belo trabalho. Adoro fazer isso. Só achei estranho o uso de abraçadeira de nylon
Thanks to share.❤
@naturefuturetech
10 ай бұрын
🌹🌹🌹
Next time you work, attach the switches one under the other with paccord sockets, you will not have to use very long paccord cable. 10 cm paccord cable will do the job.
@naturefuturetech
2 ай бұрын
Sure bro🌹
Need to use a compression punchdown tool and probably a better cable stripping tool. The way in which this was done will cause the connections to fail prematurely. Not to mention with the cheap cable stripper, there is a much easier chance of cutting into the pairs and if you nick the copper, it will weaken the connection. Sure, good tools are expensive but they make all the difference. I also agree with the comments that the patch cables are too long. I have come to realize over my career that it is better to use short (1-2ft) cables then stack the switches or use high capacity fiber between the switches and better engineer the traffic than use long cables stuffed and pinched into a rack like that which risks early cable failure.
Leave bigger gaps between panels and use wider rack for left and right cable management.
i would use velcro ties instead of zip ties, the zip ties can smash the cable and unwinds the cat twists and cause crosstalk
@naturefuturetech
Жыл бұрын
Thanks for your comment first of all bro this is a cat 6A STPcable it is too hard to handle with velcro even if we use velcro as you say after 1 year its gone lose that's why we use zip tai I'm sure its not hurting the cable❤️
@highlander200268
Жыл бұрын
@@naturefuturetech ahh ok, as long as you dont like death tie it lol, i have seen some jobs where they tie it so tight it actually cuts into the shielding
@jamiealite
6 ай бұрын
Lmao been using zip ties for years never had an issue. Never mash a cable if you know what your doing
pls use punch down tool, much faster, or the clip that came with the patch panel
do not get me wrong it looks pretty but the only reason you would ever do the runs like this is if you want each zone on there own patch panel and wanted each receptacle connected to a specific router for multiple internal networks the more common practice is you use short jumps from patch panel to router the only other reason i can think of doing this is to show off your wire-fuu which i will say is quite good
Good job👍
@naturefuturetech
7 ай бұрын
Thanks🌹
Que gran trabajo
@naturefuturetech
3 ай бұрын
🌹❤️🌹
Seriously? That is not CAT6a compliant at all. The twist should be maintained right up to the IDC terminal. I didn't see a support bar for the cables. Use a proper impact punch down tool like a Fluke/Harris. It will properly seat the wires as well as cut the tails in a single stroke. Label each cable at 1,2,3 fist back for east identification. Last, 4 days to do two days worth of work is not impressive.
Very good
@naturefuturetech
4 ай бұрын
🌹❤️🌹
U/FTP cables with UTP patchpanel !!? - very professional
There are two main metrics: 1. Good work per standards/best practices & 2. Looking good to the eyes. Aesthetics. It is possible to reach either one and not the other. However, for reliable data communications, #1 is preferred over #2. To some installers and clients, they tend to feel 'satisfied' with #2 over #1. To a professional, both have equal weight! The professional and responsable client would first prefer that installers wear PPE! Then have and use correct/proper tools. I'm wondering, isn't there a way to prevent so much wasted cable? It adds up. Any installation method that may affect the cable's geometry will negatively affect performance. Installation must consider (ease of) maintenance. Then again budget$$$ determine a lot. What was the objective of the video again?😅
good job. i prefer to stage patch panel switch, patch panel switch, etc... Less use of patch cables and cleaner aesthetic.
My job when younger times. Retired peacefully 2021 after 25 years. Now doing something else.
i need to know how make lablaning in papers, what printer and paper used
😍😍😍😍
Why these long cable runs? Why not patch directly with short cables? 6 inch or 10 inch
I’m just learn to do this type of work as of 3 days ago. I’ve been in the cable industry from 19 years and never learned this side of cabling🤦🏾♂️….now to the video, why would you use zip ties on those cables coming down from the ceiling and like some one else pointed out….those are not 24ct bundles. I get that you guys may have toned those lines 😮💨😮💨 but why didn’t you guys use Velcro straps
good
@naturefuturetech
6 ай бұрын
🌹❤️
Для врезки жилок есть инструмент который сразу хвостики проводов лишние обрезает.
Любители двойной работы, сразу кабеля биркуются, что бы потом пару часов не вызванивать и не бегать по кабинетам) Итоговое биркование без вопросов, там длина неизвестна по началу.
When you take program at college for example Computer systems technician - network systems, do they only teach you how to service these servers, or do you also learn how to run cables and connected them and so on?
@JJFlores197
2 ай бұрын
I think for this type of job, you would need to look into low-voltage or structured cabling training. The systems tech and network systems training may give you a general idea of how to do this, but I don't think they would focus too much on training.
Very very good job
@naturefuturetech
Жыл бұрын
🌹❤️
It actually requires patience and practice
@naturefuturetech
8 ай бұрын
Sure
great job! India, Pakistan or Bangladesh, I wonder? 🤔
Neat job, thorough… but you stick a very permanent rack on a high wall nook and keep it on WHEELS? 😂 Please at least tell me I missed a part and it's bolted to the wall…
Hi, what printer used to print the label??
What is network data centre what its use please reply me
👍
@naturefuturetech
Жыл бұрын
Thanks 🙏
You lost me at zip ties
Bro you are using STP Cable in cat 6 Patch panel ..it's wrong you should use CAT6A Patch panel for cat 6 A Cable
@naturefuturetech
Жыл бұрын
No bro we use cat 6 A patch panel for cat 6 A cable and for STP cable use cat 6 patch panel but in 1 patch panel we use some cable for CAT 6 because we don't have more space for extra patch panel
@lukelegg9915
Жыл бұрын
All that changes is copper size, you do have to make sure you get a proper connection with STP but it's really not going to affect anything
SALMO☣️☣️☣️☣️ ORIGINAL
Why is there a rack... on a ledge... with wheels???
Looks ok, but I would hate to troubleshoot it
Why don't u use a krone tool ?
You to use u/ftp cable on unshild patch panel, ok
Pro-tip, label the ends before you pull them. Will save you hours upon hours tracing. Also keep track of your run length and how much is left in the box !
Dude … where did you left the sheelding?
Why we use that communication circuit accessory 14:19
@JJFlores197
2 ай бұрын
That's called a patch panel. It is not technically necessary. You can build your entire network without it and it will still function just fine. The reason we use patch panels, especially in large networks is to make the cabling more organized and easy to work with instead of having a mess of cables running all over the place to the switch. With the patch panel, you just patch in whatever ports you need to make the connections active. If you have a wing of 5 classrooms and each classroom has 10 data drops, that's 50 network cables running into the network rack. All the ports should be labeled accordingly on both ends. Once you have this setup correctly, it makes it incredibly easy to activate a network port. So for example, if you have Room 5, port 15 that needs to be active, you just go to the patch panel and plug in a patch cable (ethernet cable) from port 15 at the panel into whatever port you need on the switch and its live.
not a fan of tp link and hikvision.. furthermore good job!
@naturefuturetech
3 ай бұрын
❤️🤗
Nice work, music is annoying tho
@naturefuturetech
5 ай бұрын
😔😔😔🌹
Халявно сделано если что. Но в принципе наладчики наоборот просят не жгутить, чтобы взаимопроникновения поменьше.
Yr mjhy b apny st add kr lo mn bhi cctv installation krta ho pakistan mn
What are you using to print on these labels?
@cedricwilliams641
2 ай бұрын
Probably a brothers label maker…Amazon has them
SALMO☣️🤑☣️ ORIGINAL
ang daming gagawin basta huwag ka lang madaliin😂
what switch do You use?
@naturefuturetech
4 ай бұрын
TP link
Sir rack main server ki cabling kaise hoti h aur installing kaise hoti h isape video bana please
@naturefuturetech
Жыл бұрын
Watch full video please
@naturefuturetech
Жыл бұрын
Kuch dino ke bad a jaye gi
what are "UNKNOWN WIRES" labels ????
hi
Man I hate cable ties. No one ever flush cuts them and the sharp edges they leave shred everything including my hands.
When I decided to become a provider, but the premises were not rented
Ó az isten barma! Behúzzák a drága árnyékolt kábelt és az első dolga az, hogy a patch panelnél kicsípi az árnyékolószálat és betűzi egy cat5 aljzatba.
What is the maximum length of cable used for the IP camera?
@naturefuturetech
6 ай бұрын
90 M SFTP
@security.corner
6 ай бұрын
@@naturefuturetech thanks
@dzitzels
6 ай бұрын
@@naturefuturetech- What??!!! 100m UTP hopefully at least Cat6A. At least that’s what it *should* be.
Era necesario mover así la cámara? Me mareó a los 5´ , tuve que dejar de verlo.
Awesome job and video! Cheers!
@naturefuturetech
Жыл бұрын
🌹❤️😘
SALMO☣️☣️☣️📝 ORIGINAL
SALMO☣️☣️☣️🤑☣️☣️☣️ ORIGINAL
SALMO☣️☣️☣️☣️📝 ORIGINAL
@naturefuturetech
4 ай бұрын
🌹🤗
Lucas 99 2
SALMO☣️☣️🤑☣️☣️ ORIGINAL
Cables on patch-panels not secured, yeah, nah. Lots of ports and not enough cheap switching???
RJ 45
SALMO☣️☣️🤑☣️☣️📝 ORIGINAL
20:35 видите отверстия овальные, туда провод пропускается с одной стороны и так же он выходит с другой, он не должен пыжиться в углу шкафа!!! kzread.info/dash/bejne/mIGs1I9sg8fVnsY.html
Seems like a lot of extra work punching down and then cutting, get a cheap punch down tool with the cutter and save yourself a lot of extra time. If you do this for a living you have to have the proper tools.