Installation Network data Server Rack And cable management 27U cabinet Best Setup For Office or home

Ғылым және технология

Buy Me A Coffee ☕ Here 👇
www.buymeacoffee.com/zhaider299w
how to install networking setup for school colleges and offices 27U server rack installation from 0% to 100% a huge setup for office 270 points for internet camera WIFI telephone
#hikvision #dahua #ipcom #aicontent #aico #dlink #hdd #tplink #webb
#cctv #networking #network #internet #access control #cctv camera #cable management #unbox #intercom #broadcast system #access point #electric door lock #wifi #HDMI #hard disk # internet switch management #time attendance
how to install

Пікірлер: 184

  • @fibconetfttxsupplier2424
    @fibconetfttxsupplier242420 күн бұрын

    It’s great to see these cabinet products in action in the field, thank you for your great work😇

  • @acorder2006
    @acorder20068 ай бұрын

    Neatness is ok but I am a fan of shorter Patch cables. The setup in the rack seems like it could be improved on to have shorter patches which in my experience is more serviceable.

  • @MickeyMishra
    @MickeyMishra6 ай бұрын

    To every Low Voltage Electrician? Watching this is pure harmony. However, I would negate the Zap Straps for Velcro. But I would be a Liar if I said that I did not too do the same. Instead of Labels? I just use a Sharpie. Hard to get a Punch down tool in those tight space, so glad you got it done in place.

  • @naturefuturetech

    @naturefuturetech

    6 ай бұрын

    🤗🤗🤗

  • @patrickd9551

    @patrickd9551

    3 ай бұрын

    I would also replace the hard patches with keystones. Much easier to move around (which I've done a few times myself). The added cost is negligible compared to the hours paid.

  • @L_vvy
    @L_vvy8 ай бұрын

    Just small Tip: Permament Labels -> First tie over the cable and next bend over the label so that it will additionally secure label from falling of as the cable part will be glued from both sides :D

  • @binba9
    @binba97 ай бұрын

    To those who mention the labeling + patch/switch arrangement: I suspect that this was existing wiring they had to deal with, identify and clean up. Or who knows. And I suspect they needed very specific patch ports to go to specific switches, so the paths are actually all different, it just looks clean. You can't always just jump patch ports 25-48 to switch ports 1-24 and vice versa. Then you have to choose if you keep your patch panels linear (to serially match the wall ports), or patch by function. I'm debating that in my upcoming install though I prefer the latter. Seemed like they possibly did the former.

  • @cedricwilliams641

    @cedricwilliams641

    2 ай бұрын

    Yeah…from the start of the video, you could see that it was preexisting cables. They cut them and toned them out

  • @anthonytablizo4823
    @anthonytablizo48232 ай бұрын

    Smaller cabinet, have deeper cable managers when using longer patch cables, rather than feeding everything to the side. Looks nice, but defeats the purpose of a cable manager, and screws anyone trying to feed wire through in the future. But looks ok.

  • @marioskyriakou
    @marioskyriakou9 ай бұрын

    amazing work! My only comment is that its much faster , cheaper and easier for the next guy that may come to do a work in there to use the standard - patch panel , switch , patch panel. Working this way its much more serviceable and you can use much smaller patch cables.. Other than this amazing!

  • @enroger
    @enroger8 ай бұрын

    order, cleanliness, results in a beautiful job, well done, congratulations!

  • @naturefuturetech

    @naturefuturetech

    8 ай бұрын

    Thank you 😊🌹

  • @movax20h
    @movax20hАй бұрын

    Pretty nice. I am not sure why you would go with smaller port number switches, but maybe the PoE limits were the cause. I think spending a little extra on something with good forced cooling, dual power supply, and 50 ports is way to go almost always, even in smaller setup. It makes less mess, and gives you flexibility later.

  • @gustavoalmendro
    @gustavoalmendro6 ай бұрын

    Great organization congratulations

  • @linde_learn3892
    @linde_learn3892 Жыл бұрын

    You have my full respect!

  • @naturefuturetech

    @naturefuturetech

    Жыл бұрын

    Thanks 👍🌹

  • @crew79com
    @crew79com Жыл бұрын

    Great work! Respect and +100 points for proffesionalism.

  • @naturefuturetech

    @naturefuturetech

    Жыл бұрын

    Thanks🌹for your support

  • @AjayKumar-bz5yj

    @AjayKumar-bz5yj

    11 ай бұрын

    Ajay

  • @BitFrosty
    @BitFrosty8 ай бұрын

    First use Punch Down Tool, its gonna make your life easier. Second and more important, you are untwisting pairs a bit to much. Its probably gonna pass for cat6, but still, just do it the right way. Also that patch panel is awful, i understand sometimes you have to work with what you are given, but you have nothing to secure your cable to...Otherwise, its very decent job, i would personally go up and then come down on the other side with cables just to leave enough for equipment shuffling in the future (and that's gonna happen for sure). Respect for cable labelling.

  • @alxavz18

    @alxavz18

    3 ай бұрын

    I noticed the same thing, too much untwist at patch panel, and i don't think it will certify for cat6

  • @yourmomsfriedgravy
    @yourmomsfriedgravy9 ай бұрын

    Awesome video, Mate! F'real. I'm going to be doing this for the first time very soon and I feel like after punching down the copper, the little ends will get in hard to clean places, and I'm thinking there must be a cool strategy to ensure that none of those little pieces end up being left behind. Like maybe you could get really good at aiming the debris where you want it to go, or idk. I don't know why I focus on little things like this that aren't really a big problem haha.

  • @user-io4rn6rk9h

    @user-io4rn6rk9h

    7 ай бұрын

    应该用光纤局域网加楼层内路由器😂😂😂

  • @abx42
    @abx427 ай бұрын

    That is one hell of a build out I'm jelly lol.

  • @steveo4749
    @steveo47498 ай бұрын

    Great job turning chaos into order.

  • @activepredatore1722
    @activepredatore17226 ай бұрын

    I am new in this kind of work, and the setup looks very neat and nice, but isn’t it better to have the related patch panels and switches be closer to each other, that way you only use a small cat6 cable to connect them right above each other, that way it will be easier for maintenance later; for example if there’s a problem with one specific cable with this kind of setup you might need to remove lots of cables so you can reach the specified cable but when the switch and panel are right above each other only a small cable needs to be removed or changed, i don’t know what do you think?

  • @kousik8042
    @kousik80428 ай бұрын

    excellent! marvelous

  • @morganmcgary921
    @morganmcgary9219 ай бұрын

    Very zen and satisfying video for us tech people

  • @morganmcgary921

    @morganmcgary921

    9 ай бұрын

    Curious though. For cleanliness wouldn't it have made more sense to run the cat5 through the holes in the cable management slot and feed them up or down through the grooves so you could tidy up all cabling in the back instead of the front?

  • @TheRonsmans
    @TheRonsmans7 ай бұрын

    What I don't understand is that you're using shielded cables and unshielded patch panels.

  • @TheRonsmans

    @TheRonsmans

    7 ай бұрын

    but otherwise neatly installed.

  • @grigoryk6401
    @grigoryk64017 ай бұрын

    Easy work. I did it 1000+ times. Prefer to use shorter patch cables.

  • @abx42
    @abx422 ай бұрын

    The my fellow peep's is a work of art!! I do have a question: Did the casters ever come off? If not that would give me worry.

  • @user-ct6uk2rs8j
    @user-ct6uk2rs8j8 ай бұрын

    Really impressed with your work wish to work with you

  • @chiranjitdutta987
    @chiranjitdutta9877 ай бұрын

    Well done 👍

  • @stack.1
    @stack.1 Жыл бұрын

    I actually learnt a few things from this vid, thanks

  • @naturefuturetech

    @naturefuturetech

    Жыл бұрын

    ❤️🌹❤️

  • @user-oe5pe2tl6u
    @user-oe5pe2tl6u10 ай бұрын

    How I wish to learn from you guys 👍👍

  • @karnait2884
    @karnait28848 ай бұрын

    nice and beautiful work

  • @naturefuturetech

    @naturefuturetech

    8 ай бұрын

    🌹❤️🌹

  • @MrCaberzon
    @MrCaberzonАй бұрын

    Harnessing lvl is 10% skilled.. First thing u need to do in elv works is the design and cabling skills.. this is begginer lvl.. Using cable comb for harness Velcro Tagging Design lvl,

  • @mulatuguye3200
    @mulatuguye32009 ай бұрын

    great work you have graet thanks

  • @naturefuturetech

    @naturefuturetech

    9 ай бұрын

    🌹💕🌹

  • @user-ug8kn2gy1h
    @user-ug8kn2gy1h6 ай бұрын

    May look pretty but not to Structured Cabling Standards. You don’t use Tie Wraps (aka, zip ties) on data cables. It distorts the twists in the cable causing attenuation and crosstalk. When you run the cables where they run parallel tie wrapped together it causes alien crosstalk (look it up). Is the bay grounded? Different categories of Patch Panels. Different manufacturers of patch panels with some CAT5E and some Cat6. Too much untwisted in the termination and not using the proper punch down tool. Look up BISCi standards and patch panel manufacturers standards. Belden, Lucent, AMP, and Panduit all have installation standards available online.

  • @_majara3756
    @_majara3756Ай бұрын

    I love it

  • @lunyr3555
    @lunyr35557 ай бұрын

    Great work guys

  • @naturefuturetech

    @naturefuturetech

    7 ай бұрын

    Thank you so much 😀

  • @Sousa515
    @Sousa5157 ай бұрын

    Muito belo trabalho. Adoro fazer isso. Só achei estranho o uso de abraçadeira de nylon

  • @amittarte2757
    @amittarte275710 ай бұрын

    Thanks to share.❤

  • @naturefuturetech

    @naturefuturetech

    10 ай бұрын

    🌹🌹🌹

  • @millenniumbasra
    @millenniumbasra2 ай бұрын

    Next time you work, attach the switches one under the other with paccord sockets, you will not have to use very long paccord cable. 10 cm paccord cable will do the job.

  • @naturefuturetech

    @naturefuturetech

    2 ай бұрын

    Sure bro🌹

  • @dzitzels
    @dzitzels6 ай бұрын

    Need to use a compression punchdown tool and probably a better cable stripping tool. The way in which this was done will cause the connections to fail prematurely. Not to mention with the cheap cable stripper, there is a much easier chance of cutting into the pairs and if you nick the copper, it will weaken the connection. Sure, good tools are expensive but they make all the difference. I also agree with the comments that the patch cables are too long. I have come to realize over my career that it is better to use short (1-2ft) cables then stack the switches or use high capacity fiber between the switches and better engineer the traffic than use long cables stuffed and pinched into a rack like that which risks early cable failure.

  • @chippy3350
    @chippy3350Ай бұрын

    Leave bigger gaps between panels and use wider rack for left and right cable management.

  • @highlander200268
    @highlander200268 Жыл бұрын

    i would use velcro ties instead of zip ties, the zip ties can smash the cable and unwinds the cat twists and cause crosstalk

  • @naturefuturetech

    @naturefuturetech

    Жыл бұрын

    Thanks for your comment first of all bro this is a cat 6A STPcable it is too hard to handle with velcro even if we use velcro as you say after 1 year its gone lose that's why we use zip tai I'm sure its not hurting the cable❤️

  • @highlander200268

    @highlander200268

    Жыл бұрын

    @@naturefuturetech ahh ok, as long as you dont like death tie it lol, i have seen some jobs where they tie it so tight it actually cuts into the shielding

  • @jamiealite

    @jamiealite

    6 ай бұрын

    Lmao been using zip ties for years never had an issue. Never mash a cable if you know what your doing

  • @salteveline
    @salteveline Жыл бұрын

    pls use punch down tool, much faster, or the clip that came with the patch panel

  • @111smd
    @111smd6 ай бұрын

    do not get me wrong it looks pretty but the only reason you would ever do the runs like this is if you want each zone on there own patch panel and wanted each receptacle connected to a specific router for multiple internal networks the more common practice is you use short jumps from patch panel to router the only other reason i can think of doing this is to show off your wire-fuu which i will say is quite good

  • @ganeshmate3359
    @ganeshmate33597 ай бұрын

    Good job👍

  • @naturefuturetech

    @naturefuturetech

    7 ай бұрын

    Thanks🌹

  • @user-kd4tj9yd9p
    @user-kd4tj9yd9p3 ай бұрын

    Que gran trabajo

  • @naturefuturetech

    @naturefuturetech

    3 ай бұрын

    🌹❤️🌹

  • @mikeiver
    @mikeiver8 ай бұрын

    Seriously? That is not CAT6a compliant at all. The twist should be maintained right up to the IDC terminal. I didn't see a support bar for the cables. Use a proper impact punch down tool like a Fluke/Harris. It will properly seat the wires as well as cut the tails in a single stroke. Label each cable at 1,2,3 fist back for east identification. Last, 4 days to do two days worth of work is not impressive.

  • @user-lf9ew4kz2e
    @user-lf9ew4kz2e4 ай бұрын

    Very good

  • @naturefuturetech

    @naturefuturetech

    4 ай бұрын

    🌹❤️🌹

  • @voytecs
    @voytecs7 ай бұрын

    U/FTP cables with UTP patchpanel !!? - very professional

  • @iancasey1486
    @iancasey14864 күн бұрын

    There are two main metrics: 1. Good work per standards/best practices & 2. Looking good to the eyes. Aesthetics. It is possible to reach either one and not the other. However, for reliable data communications, #1 is preferred over #2. To some installers and clients, they tend to feel 'satisfied' with #2 over #1. To a professional, both have equal weight! The professional and responsable client would first prefer that installers wear PPE! Then have and use correct/proper tools. I'm wondering, isn't there a way to prevent so much wasted cable? It adds up. Any installation method that may affect the cable's geometry will negatively affect performance. Installation must consider (ease of) maintenance. Then again budget$$$ determine a lot. What was the objective of the video again?😅

  • @williamcamp4157
    @williamcamp41572 ай бұрын

    good job. i prefer to stage patch panel switch, patch panel switch, etc... Less use of patch cables and cleaner aesthetic.

  • @tengkusulaiman
    @tengkusulaiman7 ай бұрын

    My job when younger times. Retired peacefully 2021 after 25 years. Now doing something else.

  • @eng-mohammedalhilaly4872
    @eng-mohammedalhilaly48728 күн бұрын

    i need to know how make lablaning in papers, what printer and paper used

  • @shaqueal9535
    @shaqueal95358 ай бұрын

    😍😍😍😍

  • @gernottrimmel5092
    @gernottrimmel50923 ай бұрын

    Why these long cable runs? Why not patch directly with short cables? 6 inch or 10 inch

  • @cedricwilliams641
    @cedricwilliams6412 ай бұрын

    I’m just learn to do this type of work as of 3 days ago. I’ve been in the cable industry from 19 years and never learned this side of cabling🤦🏾‍♂️….now to the video, why would you use zip ties on those cables coming down from the ceiling and like some one else pointed out….those are not 24ct bundles. I get that you guys may have toned those lines 😮‍💨😮‍💨 but why didn’t you guys use Velcro straps

  • @PNPTechTips
    @PNPTechTips6 ай бұрын

    good

  • @naturefuturetech

    @naturefuturetech

    6 ай бұрын

    🌹❤️

  • @Andrey0I
    @Andrey0I7 ай бұрын

    Для врезки жилок есть инструмент который сразу хвостики проводов лишние обрезает.

  • @Andrey0I
    @Andrey0I7 ай бұрын

    Любители двойной работы, сразу кабеля биркуются, что бы потом пару часов не вызванивать и не бегать по кабинетам) Итоговое биркование без вопросов, там длина неизвестна по началу.

  • @iggydc8034
    @iggydc80342 ай бұрын

    When you take program at college for example Computer systems technician - network systems, do they only teach you how to service these servers, or do you also learn how to run cables and connected them and so on?

  • @JJFlores197

    @JJFlores197

    2 ай бұрын

    I think for this type of job, you would need to look into low-voltage or structured cabling training. The systems tech and network systems training may give you a general idea of how to do this, but I don't think they would focus too much on training.

  • @amsadali6201
    @amsadali6201 Жыл бұрын

    Very very good job

  • @naturefuturetech

    @naturefuturetech

    Жыл бұрын

    🌹❤️

  • @mikkio5371
    @mikkio53718 ай бұрын

    It actually requires patience and practice

  • @naturefuturetech

    @naturefuturetech

    8 ай бұрын

    Sure

  • @7th_dwarf542
    @7th_dwarf5423 ай бұрын

    great job! India, Pakistan or Bangladesh, I wonder? 🤔

  • @binba9
    @binba97 ай бұрын

    Neat job, thorough… but you stick a very permanent rack on a high wall nook and keep it on WHEELS? 😂 Please at least tell me I missed a part and it's bolted to the wall…

  • @christianrosales9290
    @christianrosales92906 ай бұрын

    Hi, what printer used to print the label??

  • @user-ee1vy6fb6f
    @user-ee1vy6fb6f11 күн бұрын

    What is network data centre what its use please reply me

  • @skynetcybersystem3tech
    @skynetcybersystem3tech Жыл бұрын

    👍

  • @naturefuturetech

    @naturefuturetech

    Жыл бұрын

    Thanks 🙏

  • @N7GOTTI
    @N7GOTTI2 ай бұрын

    You lost me at zip ties

  • @er.peetervikrantbhargawa8777
    @er.peetervikrantbhargawa8777 Жыл бұрын

    Bro you are using STP Cable in cat 6 Patch panel ..it's wrong you should use CAT6A Patch panel for cat 6 A Cable

  • @naturefuturetech

    @naturefuturetech

    Жыл бұрын

    No bro we use cat 6 A patch panel for cat 6 A cable and for STP cable use cat 6 patch panel but in 1 patch panel we use some cable for CAT 6 because we don't have more space for extra patch panel

  • @lukelegg9915

    @lukelegg9915

    Жыл бұрын

    All that changes is copper size, you do have to make sure you get a proper connection with STP but it's really not going to affect anything

  • @mikoaipan7351
    @mikoaipan73514 ай бұрын

    SALMO☣️☣️☣️☣️ ORIGINAL

  • @JasonNoseworthy
    @JasonNoseworthy11 ай бұрын

    Why is there a rack... on a ledge... with wheels???

  • @focusedelectronics
    @focusedelectronics7 ай бұрын

    Looks ok, but I would hate to troubleshoot it

  • @fabio03171
    @fabio0317111 ай бұрын

    Why don't u use a krone tool ?

  • @goldvideo446
    @goldvideo4467 ай бұрын

    You to use u/ftp cable on unshild patch panel, ok

  • @KingTrump2024
    @KingTrump20248 ай бұрын

    Pro-tip, label the ends before you pull them. Will save you hours upon hours tracing. Also keep track of your run length and how much is left in the box !

  • @abo1428
    @abo14286 ай бұрын

    Dude … where did you left the sheelding?

  • @user-yz6fi3kv1w
    @user-yz6fi3kv1w2 ай бұрын

    Why we use that communication circuit accessory 14:19

  • @JJFlores197

    @JJFlores197

    2 ай бұрын

    That's called a patch panel. It is not technically necessary. You can build your entire network without it and it will still function just fine. The reason we use patch panels, especially in large networks is to make the cabling more organized and easy to work with instead of having a mess of cables running all over the place to the switch. With the patch panel, you just patch in whatever ports you need to make the connections active. If you have a wing of 5 classrooms and each classroom has 10 data drops, that's 50 network cables running into the network rack. All the ports should be labeled accordingly on both ends. Once you have this setup correctly, it makes it incredibly easy to activate a network port. So for example, if you have Room 5, port 15 that needs to be active, you just go to the patch panel and plug in a patch cable (ethernet cable) from port 15 at the panel into whatever port you need on the switch and its live.

  • @botchubby2776
    @botchubby27763 ай бұрын

    not a fan of tp link and hikvision.. furthermore good job!

  • @naturefuturetech

    @naturefuturetech

    3 ай бұрын

    ❤️🤗

  • @user-ui2ye4fp4w
    @user-ui2ye4fp4w5 ай бұрын

    Nice work, music is annoying tho

  • @naturefuturetech

    @naturefuturetech

    5 ай бұрын

    😔😔😔🌹

  • @vectra-sx3cw
    @vectra-sx3cw5 ай бұрын

    Халявно сделано если что. Но в принципе наладчики наоборот просят не жгутить, чтобы взаимопроникновения поменьше.

  • @zeeshanahmad5314
    @zeeshanahmad53147 ай бұрын

    Yr mjhy b apny st add kr lo mn bhi cctv installation krta ho pakistan mn

  • @dtcoleman05
    @dtcoleman056 ай бұрын

    What are you using to print on these labels?

  • @cedricwilliams641

    @cedricwilliams641

    2 ай бұрын

    Probably a brothers label maker…Amazon has them

  • @mikoaipan7351
    @mikoaipan73514 ай бұрын

    SALMO☣️🤑☣️ ORIGINAL

  • @KataTukuTV
    @KataTukuTV4 ай бұрын

    ang daming gagawin basta huwag ka lang madaliin😂

  • @59.2charisphilip.5
    @59.2charisphilip.54 ай бұрын

    what switch do You use?

  • @naturefuturetech

    @naturefuturetech

    4 ай бұрын

    TP link

  • @veera1947
    @veera1947 Жыл бұрын

    Sir rack main server ki cabling kaise hoti h aur installing kaise hoti h isape video bana please

  • @naturefuturetech

    @naturefuturetech

    Жыл бұрын

    Watch full video please

  • @naturefuturetech

    @naturefuturetech

    Жыл бұрын

    Kuch dino ke bad a jaye gi

  • @FedericoPagliai
    @FedericoPagliai5 ай бұрын

    what are "UNKNOWN WIRES" labels ????

  • @abdulsajid6284
    @abdulsajid62844 ай бұрын

    hi

  • @jleote
    @jleote3 ай бұрын

    Man I hate cable ties. No one ever flush cuts them and the sharp edges they leave shred everything including my hands.

  • @weamigo
    @weamigo8 ай бұрын

    When I decided to become a provider, but the premises were not rented

  • @NoName-xc3ux
    @NoName-xc3ux6 ай бұрын

    Ó az isten barma! Behúzzák a drága árnyékolt kábelt és az első dolga az, hogy a patch panelnél kicsípi az árnyékolószálat és betűzi egy cat5 aljzatba.

  • @security.corner
    @security.corner6 ай бұрын

    What is the maximum length of cable used for the IP camera?

  • @naturefuturetech

    @naturefuturetech

    6 ай бұрын

    90 M SFTP

  • @security.corner

    @security.corner

    6 ай бұрын

    @@naturefuturetech thanks

  • @dzitzels

    @dzitzels

    6 ай бұрын

    @@naturefuturetech- What??!!! 100m UTP hopefully at least Cat6A. At least that’s what it *should* be.

  • @hugonz1969
    @hugonz19697 ай бұрын

    Era necesario mover así la cámara? Me mareó a los 5´ , tuve que dejar de verlo.

  • @samjones4327
    @samjones4327 Жыл бұрын

    Awesome job and video! Cheers!

  • @naturefuturetech

    @naturefuturetech

    Жыл бұрын

    🌹❤️😘

  • @mikoaipan7351
    @mikoaipan73514 ай бұрын

    SALMO☣️☣️☣️📝 ORIGINAL

  • @mikoaipan7351
    @mikoaipan73514 ай бұрын

    SALMO☣️☣️☣️🤑☣️☣️☣️ ORIGINAL

  • @mikoaipan7351
    @mikoaipan73514 ай бұрын

    SALMO☣️☣️☣️☣️📝 ORIGINAL

  • @naturefuturetech

    @naturefuturetech

    4 ай бұрын

    🌹🤗

  • @brunopirescardoso4157
    @brunopirescardoso41577 ай бұрын

    Lucas 99 2

  • @mikoaipan7351
    @mikoaipan73514 ай бұрын

    SALMO☣️☣️🤑☣️☣️ ORIGINAL

  • @bentheguru4986
    @bentheguru49866 ай бұрын

    Cables on patch-panels not secured, yeah, nah. Lots of ports and not enough cheap switching???

  • @SuperSecretM_Admin.M_Thailand
    @SuperSecretM_Admin.M_Thailand2 ай бұрын

    RJ 45

  • @mikoaipan7351
    @mikoaipan73514 ай бұрын

    SALMO☣️☣️🤑☣️☣️📝 ORIGINAL

  • @Andrey0I
    @Andrey0I7 ай бұрын

    20:35 видите отверстия овальные, туда провод пропускается с одной стороны и так же он выходит с другой, он не должен пыжиться в углу шкафа!!! kzread.info/dash/bejne/mIGs1I9sg8fVnsY.html

  • @ecu8r
    @ecu8r10 ай бұрын

    Seems like a lot of extra work punching down and then cutting, get a cheap punch down tool with the cutter and save yourself a lot of extra time. If you do this for a living you have to have the proper tools.

Келесі