I Beam - Lateral Torsional Buckling Test

Ғылым және технология

Lateral torsional buckling occurs when an applied load results in both lateral displacement and twisting of a member. You can see the first part of the video shows bending of the I beam and then it starts to buckle i.e. lateral displacement and twisting.
📲 Download my RC Section App 📲
apps.apple.com/gb/app/rc-sect...
▶️ Watch Eurocode 3 Series
Part 01 - Introduction to Eurocode 3: • Introduction to Euroco...
Part 02 - Introduction to Eurocode 0: • Introduction to Euroco...
Part 03 - Eurocode 3 Structural Analysis: • Eurocode 3 Structural ...
Part 04 - Brittle Fracture: • Brittle Fracture | Eur...
Part 05 - Cross-section Classification + Buckling: • Cross-section Classifi...
Part 06 - Steel Beam Design - Bending + Example: • Steel Beam Design - Be...
Part 07 - Steel Beam Design - Shear: • Steel Beam Design - Sh...
Part 08 - Steel Beam Design - SLS: • Steel Beam Design - Se...
Part 09 - Introduction to Lateral Torsional Buckling: • Introduction to Latera...
Part 10 - Design Buckling Resistance Moment: • How to Calculate Desig...
Part 11 - Design Buckling Resistance Examples: • Calculation Examples o...
Part 12 - Steel Column - Compression Member Design: • Steel Column Design | ...
Part 13 - Steel Column - Buckling Resistance: • Steel Column Design | ...
Part 14 - Steel Column - Buckling Example: • Steel Column Design - ...
Part 15 - Tension Member Design - Fastener Design: • Steel Tension Member D...
Part 16 - Tension Member Design - Connections: • Steel Tension Member D...
Part 17 - Axial Compression, Bending, Torsion: • Steel Member Design | ...
Part 18 - Bolted Connections - Pinned & Fixed (Rigid): • Steel Connections | Bo...
Part 19 - Welded Connections - Pinned & Fixed (Rigid): • Steel Connections | We...
🔔 Connect with Dilakshana Mayadunne 🔔
Facebook.com/IamDilakshana
Twitter.com/IamDilakshana
LinkedIn.com/in/Dilakshana/
civil_structural_engin
www.dilakshana.com/
Join Linkedin group (Design to Eurocodes) 👉🏻 / 9004030
Join Facebook group (Let’s Talk Civil Engineering) 👉🏻 / civilandstructuralengi...
#IBeam #SteelDesign #LateralTorsionalBuckling
Disclaimer: This material is provided on an 'as is' basis without warranty of any kind. There is no warranty that the material will meet your requirements, that the material is error-free, that results obtained from the use of the material will be reliable, nor that any errors in the material will be corrected.
Attribution:
Video - Lateral Torsional Buckling Test by Faculty of Civil Engineering RWTH Aachen University (www.fb3.rwth-aachen.de) is licensed under CC BY 4.0 (creativecommons.org/licenses/.... Original video was edited.
Music - Sleeplessness, The Brothers Records - / @donguyrockwell

Пікірлер: 37

  • @muthomimunyua9062
    @muthomimunyua90623 жыл бұрын

    Thanks. It was very hard to visualise this phenomenon prior to seeing your video. Keep up the good work.

  • @IamDilakshana

    @IamDilakshana

    3 жыл бұрын

    Muthomi Munyua Glad you found it useful.

  • @shivamsharanlall672
    @shivamsharanlall6724 жыл бұрын

    Thanks for showing it practically.

  • @IamDilakshana

    @IamDilakshana

    4 жыл бұрын

    shivam sharan lall 👍🏻

  • @markyerges316
    @markyerges316 Жыл бұрын

    Can you provide the size and span of the beam as well as the exact location of the load along the length (assuming it's at midspan right now)? I'm curious how this compares to AISC equations.

  • @catalinaaraneda9220
    @catalinaaraneda92202 жыл бұрын

    Very good and funny videos bring a great sense of entertainment!

  • @TheLuminousOne
    @TheLuminousOne Жыл бұрын

    As an Engineer, i recommend you test beams for bilateral contortional buckling and collateral torsional flexure. These are not very well understood failure modes.

  • @vineethbandari4946
    @vineethbandari49462 жыл бұрын

    what value of load have you taken as the critical buckling load?

  • @davepowell7168
    @davepowell7168 Жыл бұрын

    Thx, the bolts and welds jointing vierendeel floor trusses with the columns of WTC towers didn't fail because of excess loading ,softening from heat or linear expansion resulting from planestrike alone I hoped to see this test reac catastrophic failure

  • @enfycius0131
    @enfycius0131 Жыл бұрын

    I have a question. Here, is I-Beam subjected to a positive bending moment?

  • @krutideepankar5457
    @krutideepankar54573 жыл бұрын

    Thank u so much

  • @IamDilakshana

    @IamDilakshana

    3 жыл бұрын

    Most welcome.

  • @thaminduheshan91
    @thaminduheshan913 жыл бұрын

    How the graphs are get plotted in real time? Is it done by the apparatus it self?

  • @IamDilakshana

    @IamDilakshana

    3 жыл бұрын

    If you want detailed graphs then you can use a kit with digital force & displacement sensors (simultaneous) connected to a computer. These sensors normally come with software that plots the graphs.

  • @kzero9714
    @kzero97142 жыл бұрын

    lol now i know that there's also plastic strain after lateral torsional buckling.. btw may i know: a. the steel profile size b. the distance between support c. the condition of support (confinement)

  • @divyanshumishra7702

    @divyanshumishra7702

    2 жыл бұрын

    Support condition seems semi-rigid

  • @suryaprasanthmuddana7038
    @suryaprasanthmuddana70383 жыл бұрын

    can u tell me the name of apparatus used

  • @IamDilakshana

    @IamDilakshana

    3 жыл бұрын

    This testing rig is comprised of moveable hydraulic jack (allow for the lateral shift) and support units with degrees of freedom to facilitate the lateral torsional buckling test.

  • @varsharane1690
    @varsharane16903 жыл бұрын

    Pls tell me the name of the apparatus used

  • @IamDilakshana

    @IamDilakshana

    3 жыл бұрын

    This testing rig is comprised of moveable hydraulic jack (allow for the lateral shift) and support units with degrees of freedom to facilitate the lateral torsional buckling test.

  • @mareprah
    @mareprah Жыл бұрын

    Can someone tell me if vertical stiffeners would help in this case at all? Or do they help against local buckling only?

  • @mareprah

    @mareprah

    Жыл бұрын

    @@19Borneo67 thank you for a very detailed answer. You helped me with my question greatly.

  • @drax1938
    @drax19384 жыл бұрын

    Are u from sl?

  • @IamDilakshana

    @IamDilakshana

    4 жыл бұрын

    Yes, I am.

  • @uziahhsoares5689
    @uziahhsoares56893 жыл бұрын

    From Brazil. What is the dimensions of this steel beam? W150x13.... W200x...

  • @IamDilakshana

    @IamDilakshana

    3 жыл бұрын

    Hi - This is a 330x160mm steel beam

  • @uziahhsoares5689

    @uziahhsoares5689

    3 жыл бұрын

    @@IamDilakshana Thanks very much. Please ...the length...

  • @IamDilakshana

    @IamDilakshana

    3 жыл бұрын

    UZIAHH SOARES You’re welcome. Beam length is 6.2m.

  • @mafeceng

    @mafeceng

    3 жыл бұрын

    @@IamDilakshana the load was applied on the beam with what distance from the pin? Is that pin holed on supports?

  • @IamDilakshana

    @IamDilakshana

    3 жыл бұрын

    Marcos Ferreira Load is applied approximately 1.86m from the nearest support which is a spring with a spring stiffness of 40430kNm/rad.

  • @giovannimantovani1205
    @giovannimantovani12053 жыл бұрын

    I tried to replicate this test in the Software Ansys Mechanical, if someone want to know more about this, reply this coment! =)

  • @IamDilakshana

    @IamDilakshana

    3 жыл бұрын

    Please share more. What are your findings? Can you extract a video from Ansys?

  • @giovannimantovani1205

    @giovannimantovani1205

    3 жыл бұрын

    @@IamDilakshana Using the conditions: - 330x160mm steel beam; - 6,2m - Force aplied 1,86m from nearest pin - Spring stiffness: 40430kNm/rad I found a Force limit of 160,89kN to buckle! Very close to your test! I'll try to make a video soon

  • @mohamedsalahawad3011
    @mohamedsalahawad30112 жыл бұрын

    I beam is not good Box sec and C chanel BTB is good

Келесі