HVAC 045 service valve introduction

Пікірлер: 53

  • @AngelHVACR
    @AngelHVACR3 жыл бұрын

    I start trade school august 9th cant wait man you've tought me a lot and actually make me feel good going in

  • @AngelHVACR

    @AngelHVACR

    Жыл бұрын

    Im already a year in the trade came back to this video as I replaced like my 3rd king valve now on a reciever loving the trade man🙏🏽👌🏽

  • @jasons2832
    @jasons28323 жыл бұрын

    Thanks Ty! I’m not in the industry but I love to watch these bite sized videos to add to my general knowledge.

  • @love2hvac

    @love2hvac

    3 жыл бұрын

    Thank you. HVAC and its science is all around us! I'm glad your enjoying it. I still love this stuff.

  • @ReliableHVACR
    @ReliableHVACR3 жыл бұрын

    Love the cut away views 👏🏽 great info

  • @fernandojorja2685
    @fernandojorja268510 ай бұрын

    Muchas Gracias por la explicación ! From Argentina

  • @ulairecantea9231
    @ulairecantea92312 ай бұрын

    Thank you for a great video. Really appreciate it.

  • @olegkash1
    @olegkash1 Жыл бұрын

    Thank you for great video!

  • @Pretzel114
    @Pretzel1143 жыл бұрын

    Great information! Thank you!

  • @hg2.
    @hg2.2 жыл бұрын

    Note to self: a KING VALVE is located on the exit of a receiver. (Thank you for clarifying that one, too.)

  • @love2hvac

    @love2hvac

    2 жыл бұрын

    Yeah it's not a big deal unless you work with a refregeration guy.

  • @robertl.7657
    @robertl.76573 жыл бұрын

    Keep the good work!!!👍

  • @michaelcostello6991
    @michaelcostello69913 жыл бұрын

    Great job. Thank you

  • @vernroach3413
    @vernroach34133 ай бұрын

    Excellent refresher...Thanks.

  • @brianmcdermott1718
    @brianmcdermott17183 ай бұрын

    Great tips Ty. thank you.

  • @servicedealstoday
    @servicedealstoday Жыл бұрын

    Hi, thank you for taking the time to cut a valve open and show us the internal operation. I have an HVAC question, regarding the forward mid and backseat silver color valve, is it possible to illustrate the valve internally as you did with the original service valve. Trying to learn as much as possible about refrigeration.

  • @dustindavis749
    @dustindavis749 Жыл бұрын

    very helpful thank you for the video

  • @musakavalci9470
    @musakavalci94703 жыл бұрын

    Simply the best

  • @ronie1337
    @ronie1337 Жыл бұрын

    Thanks for the info

  • @mobilecommunicationsnetwor5268
    @mobilecommunicationsnetwor52683 жыл бұрын

    Repairing this value in place is key for R22 systems. Any repair ideas would be good to hear.

  • @love2hvac

    @love2hvac

    3 жыл бұрын

    Blue Leak lock on the large hex cap stops that one. (Never put leak lock on the service port cap). Good brass calves cap and shrader core replacement solve the other.

  • @Nightmare52199
    @Nightmare5219918 күн бұрын

    I had a few hex service valves leak from the hex head position. Do you think that is from a faulty valve or maybe technicians who put a lot of force when they fully open the valve? I've seen a lot of guys do that. Thanks for the awesome video, these are very educational!

  • @love2hvac

    @love2hvac

    18 күн бұрын

    Usually from overheating during brazing

  • @gusel9
    @gusel9 Жыл бұрын

    perfect explained.👏

  • @love2hvac

    @love2hvac

    Жыл бұрын

    Thank you

  • @hg2.
    @hg2.2 жыл бұрын

    TYSM. I live in fear of 'screwing up' here, e.g, cracking a front-seated valve when there's no schrader in the service port (did I get that scenario right?)

  • @love2hvac

    @love2hvac

    2 жыл бұрын

    Don't be afraid of making mistakes! I have made lots of mistakes! Mistakes are part of learning. I'm still learning! But here you are watching, learning and that's what's important. Just be safe, everything else can be fixed or replaced.

  • @Elisummit845
    @Elisummit8453 жыл бұрын

    1 thing I didn't hear being mentioned. Not sure if it's true with all companies but Goodman at least considers the cap of the service valve as the final seal, as the valve might sometimes leak a bit. In my experience, after fully unscrewing the service valve, give it a little turn back. I have seen when it's all the way open it sometimes leaks a bit.

  • @love2hvac

    @love2hvac

    3 жыл бұрын

    Yes the cap is for sure the final seal. Always pull a vacuum with the cap on.

  • @GurdeepSingh-bu6ee
    @GurdeepSingh-bu6ee2 жыл бұрын

    Very nice video, thanks for posting. I have a question. You mentioned that new condenser has all the ref. and the valve is in Front seat position. Very true. That's what I have. My piping to and from is complete. Did the vacuum with shredder valve out on suction side. As soon as I open the "top cover off " of the suction service valve, Ilost the vacuum. So that means the suction service valve has to be open half way so that the slot in the stem faces the service port, if I understand correctly. If I'm correct, how to achieve that location. Please advice. I need to solve my start up problem. Thanks and regards.

  • @love2hvac

    @love2hvac

    2 жыл бұрын

    Is it this kind of valve? kzread.info/dash/bejne/dYx8xbWrdtOymNY.html

  • @GurdeepSingh-bu6ee

    @GurdeepSingh-bu6ee

    2 жыл бұрын

    No, It is new modern unit with L-key and cap. Any how someone told me that valve is damaged due to heat from brazing pipe to it. Neoprene ring is burnt. That is the reason. So he suggested that after vacuuming the system, release 410a from liquid line to break the vacuum. Than open the Low side valve with nice gloves on and quickly. Than put the cap with sealant. Never open again. So I did. Lost little refrigerant. But unit is working now. I Thank you and all those on KZread trying to help each other that leads to Harmony and love in community. Thanks GOD.

  • @love2hvac

    @love2hvac

    2 жыл бұрын

    Sorry I miss understood. I'm glad you got it going!

  • @Keegeth
    @Keegeth3 жыл бұрын

    Show how a king valve works

  • @coreyr8870
    @coreyr8870 Жыл бұрын

    I recently ran into a valve on a commercial trane condenser unit that had two service ports with the condenser fan pressure switch on a third port off the bottom. The tech I was working with said it had been left back seated which caused the pressure switch to be closed off to the refrigerant. He said it should be left mid seated to allow the pressure switch to cycle on the third condenser fan on each circuit. Have you seen this valve and does that make sense? Just asking because I cannot find any information on this valve

  • @love2hvac

    @love2hvac

    Жыл бұрын

    Yes that is common. I don't like to put stitches or controls on those valves only because the next tech might do just that, back seat the valve and make the switch worthless. Great point

  • @mobilecommunicationsnetwor5268
    @mobilecommunicationsnetwor52683 жыл бұрын

    Is the service value the main source of leaks on the condenser side of the system?

  • @love2hvac

    @love2hvac

    3 жыл бұрын

    Simplest leaks are service valves, simple to fix. Next would be how well they where brazed in. The evaporator coil is the biggest leak place inside and the discharge line and lower portion of the condensors coil biggest leak outside.

  • @mobilecommunicationsnetwor5268

    @mobilecommunicationsnetwor5268

    3 жыл бұрын

    @@love2hvac Thank you for detailed answers.

  • @thisisyourcaptainspeaking2259
    @thisisyourcaptainspeaking22593 жыл бұрын

    Dice Clay valve (One And Done).

  • @fromanabe8639
    @fromanabe86392 жыл бұрын

    Can you "break" a service valve by continuing to back the valve stem out? I did that and now it turns much too easily. I think I probably stripped the threads.

  • @love2hvac

    @love2hvac

    2 жыл бұрын

    Yes if the previous person overtightened it, they can break. The threads on the valve are ok but the threads of the valve core can damage and break.

  • @mobilecommunicationsnetwor5268
    @mobilecommunicationsnetwor52683 жыл бұрын

    Is there any option to upgrade the Schrader valve to stop any leakage? Any seals or process to stop a leak without replacement from the top hex value?

  • @love2hvac

    @love2hvac

    3 жыл бұрын

    HVAC 044 I show a brass cap with an o-ring that I like. Many codes now are requiring the locking caps for new systems :(

  • @mobilecommunicationsnetwor5268

    @mobilecommunicationsnetwor5268

    3 жыл бұрын

    @@love2hvac so it seems that there's always going to be leakage of this valve and the cap is the only way to stop or limit this? Any upgraded valve? Would it be best practice just to change the valves every time you do maintenance?

  • @love2hvac

    @love2hvac

    3 жыл бұрын

    @@mobilecommunicationsnetwor5268 A leaking shrader will not be an issue with a good brass cap with an o-ring. I've seen shredders that where 20 years old with no issue if they are kept clean. The biggest problem is the plastic caps. Once you replace the plastic cap with brass it's a non issue.

  • @mobilecommunicationsnetwor5268

    @mobilecommunicationsnetwor5268

    3 жыл бұрын

    @@love2hvac Ty, Thanks.

  • @joebanks174
    @joebanks1746 ай бұрын

    How can you know whether a port has a shrader or not?

  • @love2hvac

    @love2hvac

    5 ай бұрын

    Look inside. If it's hollow it does not have one. Take the cap off your tire and look in there. The valve core in your tire and in the unit looks identical

  • @mike-yp1uk
    @mike-yp1uk Жыл бұрын

    King valve allows a pull down so work can be done on the handler side?

  • @npdomingo
    @npdomingo2 жыл бұрын

    What's the part number for the universal ball valve?

  • @love2hvac

    @love2hvac

    2 жыл бұрын

    3/4" ODF BVSS Series Refrigeration Ball Valve w/ Access Valve, Brass Locking Seal Cap (R-410A) SKU: 081017 Brand: White Rodgers 7/8" ODF BVS Series Refrigeration Ball Valve w/ Access Valve (R-410A) SKU: 806758 Brand: White Rodgers 3/8" ODF BVS Series Refrigeration Ball Valve w/ Access Valve (R-410A) SKU: 806752 Brand: White Rodgers 3/8" ODM Ball Valve w/ Schrader Valve SKU: RPBV038 Brand: RLS