How to use the position control mode of the servo motor (by PLC pulse control)

Ғылым және технология

The video introduces the connection and control (position control mode) of Omron PLC (CP1E N40DT-D) and ATO servo motor system. We have a wide range power rating from 50W to 7.5kW and holding torque 0.16Nm to 96Nm. Buy it online: www.ato.com/ac-servo-motors
The video is roughly divided into:
1. Hardware device display.
2. ATO servo system and OMRON PLC wiring principle.
3. ATO servo controller setting
4. Omron PLC program explanation
5. Operation details explained.
In addition to using the Omron PLC to control the ATO servo system, we can also use a similar brand PLC to control the ATO servo system such as: Mitsubishi PLC, Siemens PLC, Delta PLC and so on.

Пікірлер: 61

  • @MrFernandoBedoya
    @MrFernandoBedoya3 жыл бұрын

    Excellent. Thanks for sharing. We need more instructional videos like this one, with wiring diagrams.

  • @DavidRomeroGuillen
    @DavidRomeroGuillen2 жыл бұрын

    Thank you for sharing. Very nice to watch your videos. Greetings from Spain.

  • @jaredhanson9758
    @jaredhanson97582 жыл бұрын

    Glad I found this video.

  • @PANELLISTRIK.MANAGEMENT
    @PANELLISTRIK.MANAGEMENT3 жыл бұрын

    Detail & Informative. Nice

  • @RaviShankar-lm3xn
    @RaviShankar-lm3xn Жыл бұрын

    great work sir

  • @stuhaif9190
    @stuhaif91902 жыл бұрын

    Thats Excellent u do good

  • @saidulliquied6601
    @saidulliquied66013 жыл бұрын

    Real Engineer

  • @saidulliquied6601
    @saidulliquied66013 жыл бұрын

    Ossam Video

  • @carfairautosharingincorpor8005
    @carfairautosharingincorpor8005 Жыл бұрын

    It looks like the stop pushbutton is wired normally open so it will not fail safe.

  • @ganiulhasan4461
    @ganiulhasan4461 Жыл бұрын

    Best

  • @htekarkar
    @htekarkar Жыл бұрын

    Can you please upload the pdf version of ladder program bcoz the video resolution is too low and could not be read? Thanks

  • @vikramshinde4546
    @vikramshinde45463 жыл бұрын

    Can you please tell m how to select MCB for servo motor, I have 1.5kw servo 6A current

  • @pba21
    @pba214 жыл бұрын

    If you can offer training, then technicians can buy your products for service in many industries. Do you?

  • @irmanomron7802
    @irmanomron78022 жыл бұрын

    Mr help me,,Is the plc cp1e n40 dt d used for 2 servo motors / 2 axis?

  • @agungsetyono8715
    @agungsetyono87153 жыл бұрын

    Hello can you help me, how to wiring motor controll to plc...tank you

  • @shahzebkhan3392
    @shahzebkhan33923 жыл бұрын

    How we change the mode programmatically ?

  • @laserfalcon
    @laserfalcon7 ай бұрын

    What would the in/out be used for?

  • @car9167
    @car91673 жыл бұрын

    How come the CX PLC programmer works with the servo controller? Are the servo controller commands standardized or can you configure them in the CX programmer? Oh I see you control the servo controller with a PLC you programmed. Can the PLC programmed to send a configurable number of step impulses to the servo driver when an input signal (like the Z signal from encoder) is received? I'm thinking this can be used for servo/spindle positioning

  • @ATOcom

    @ATOcom

    3 жыл бұрын

    Yes, these can be achieved. But I don't have CX.

  • @joshuajavier5158
    @joshuajavier5158 Жыл бұрын

    How to know if I will be using Dm100 to control the servo motor?

  • @mahmoudsosa6580
    @mahmoudsosa65804 жыл бұрын

    does it work for all types of servo motor or only for the type wjich on this video ?

  • @ATOcom

    @ATOcom

    4 жыл бұрын

    Just for ATO SERVO motor,www.ato.com/ac-servo-motors

  • @user-kk4np7xl2b
    @user-kk4np7xl2b4 жыл бұрын

    How to use the position control mode of the servo motor Amplifier Driver model : Yaskawa SGD7D-5R5A00A or not

  • @nerwusek19
    @nerwusek194 жыл бұрын

    Hi bud Can you help me connect servo controller of spindle motor to Sinumerik 808d? Please

  • @akhilkumarparida2445
    @akhilkumarparida24452 жыл бұрын

    How to show robot cycle time on omron hmi and omron plc

  • @kaeeeeee6505
    @kaeeeeee65054 жыл бұрын

    Hello there, can i ask what music you're using?

  • @Vivenk88

    @Vivenk88

    4 жыл бұрын

    Not relevant to the topic but Shazam tells me it, "A Moment With you (Original Mix) - Tropical Bleyage"

  • @jeffersonradores65
    @jeffersonradores654 жыл бұрын

    what is V0.01?

  • @shahzebkhan3392
    @shahzebkhan33923 жыл бұрын

    How we can control the speed ? Using PWM or Digital Output ? And at which pin we have to send the signal.

  • @ATOcom

    @ATOcom

    3 жыл бұрын

    To control the speed of the motor, you only need to adjust the pulse output frequency (adjust the frequency storage unit data in the "SPEED" command, D100 in the video). The pulse output is used here. The speed signal can be output by 100.00 and the direction signal by 100.02.

  • @shahzebkhan3392

    @shahzebkhan3392

    3 жыл бұрын

    @@ATOcom can we change the mode programmatically like pr000 etc

  • @peterpanini96
    @peterpanini966 ай бұрын

    Basically this work like standard inverter ac motor ... no positional moving programming here... 🤔

  • @yasalujuan
    @yasalujuan4 жыл бұрын

    Por que no controlan directamente el driver con la salida del plc? porque usan reles en vez de usar los contactos del plc?

  • @ATOcom

    @ATOcom

    4 жыл бұрын

    To protect the PLC

  • @lct9031
    @lct90314 жыл бұрын

    Hi. What is the NC for on the PLC itself? I dont see anyone use it and the manuals also dont explain whats the purpose of it

  • @ATOcom

    @ATOcom

    4 жыл бұрын

    Where do you see the NC, in the program or on the hardware? NC generally refers to the state of the contacts, normally closed contacts. There is also a normally open contact NO.

  • @lct9031

    @lct9031

    4 жыл бұрын

    On the hardware... if you look at the plc, you will see when you hard wire your plc you have your terminals are labelled "+", "-", "COM", "01", etc but there are also ones labelled "NC"... what is the purpose of that terminal?

  • @ATOcom

    @ATOcom

    4 жыл бұрын

    @@lct9031 I get it, the NC you said refers to the empty terminal. Your PLC housing is shared by multiple models. The model you use does not use that terminal, so it is marked as NC. No wires need to be connected to that terminal.

  • @minhtrung4118
    @minhtrung411810 ай бұрын

    This is speed control mode (continuous mode), not position control mode

  • @fjrdavinautomationabregana5733
    @fjrdavinautomationabregana57333 жыл бұрын

    Sir please ellaborate your vlog for beginers.

  • @anupsharma8548
    @anupsharma85483 жыл бұрын

    But sir pls upload a program on basis of servo motor with ball screw, slider movement.... Pls sir

  • @ATOcom

    @ATOcom

    3 жыл бұрын

    Refer to this video: kzread.info/dash/bejne/k4tsq8WHhJO_h7w.html

  • @abhayramani222
    @abhayramani222 Жыл бұрын

    How to omron plc use model name send please

  • @electroniclover5589
    @electroniclover55892 жыл бұрын

    May I know why need to connect relay

  • @ATOcom

    @ATOcom

    2 жыл бұрын

    To protect the terminals of the PLC.

  • @electroniclover5589

    @electroniclover5589

    2 жыл бұрын

    @@ATOcom is because the npn and pnp

  • @jcvargas2669
    @jcvargas26692 жыл бұрын

    Hello.can you create a video how to use danfoss.thank you in advance..!

  • @SurajKumar-or5hx
    @SurajKumar-or5hx Жыл бұрын

    Sir me bhi sikhana chahta hu

  • @testarossa0779
    @testarossa07793 жыл бұрын

    Oke

  • @braineedly7543
    @braineedly75432 жыл бұрын

    Why could 100.00 and 100.02 work, whereas they're not be programmed on ladder?

  • @ATOcom

    @ATOcom

    2 жыл бұрын

    Because this is its dedicated port for pulse output.

  • @braineedly7543

    @braineedly7543

    2 жыл бұрын

    @@ATOcom How to program them?

  • @quylele5669
    @quylele56693 жыл бұрын

    you can sent code

  • @junaidsaifi7559
    @junaidsaifi75594 жыл бұрын

    Thanks sir aap ek video delta servo ka upper video bana jesam servo ko 90 90 90 90 degree mai ghuman chaiye Faleminderit zotëri aap ek video delta servo ka video e sipërme bana jesam servo ko 90 90 90 90 shkallë mai ghuman chaiye Thanks sir aap ek video delta servo ka upper video bana jesam servo ko 90 90 90 90 degree mai ghuman chaiye Faleminderit zotëri aap ek video delta servo ka video e sipërme bana jesam servo ko 90 90 90

  • @aforabbottabad7977
    @aforabbottabad79773 жыл бұрын

    how to set parameters a half video and a useless video i will nake complete video of servo in each and every mode.

  • @epride38
    @epride384 жыл бұрын

    music too loud it disrupt the focus on what you doing.

  • @ATOcom

    @ATOcom

    4 жыл бұрын

    So sorry

  • @fjrdavinautomationabregana5733
    @fjrdavinautomationabregana57333 жыл бұрын

    You have no methodology of teaching. How to get to the viewers if not discuss step by step....

  • @jeffersonradores65
    @jeffersonradores654 жыл бұрын

    what is V0.01?

Келесі