How To Test Your Defrost Thermostat & How They Work

Тәжірибелік нұсқаулар және стиль

This video shows the proper way to test your defrost thermostat. There is a lot of misinformation on testing the defrost thermostat. Most defrost thermostats CANNOT be tested in a glass of ice water because they have a closing temperature that is colder than 34°F.
If you find that you have a bad defrost thermostat you can shop for a new one on our online store by searching with your refrigerators model number, or entering the part number off of the old defrost thermostat here: partsdr.com/appliance-type/ref... We sell new OEM appliance parts for Whirlpool, Maytag, Kenmore, Amana, Estate, Roper, Frigidaire, Electrolux, Tappan, Westinghouse, Kitchen Aid, Jenn Air, Bosch, LG, Samsung, and more.
If your refrigerator is not going through the automatic defrost cycle then you will need to test the defrost thermostat on your refrigerator. When the refrigerator stops going through the automatic defrost cycle the refrigerator will not cool properly because the frost will block the air flow on the evaporator coil and cause the cold air to stop circulating. The defrost thermostat is usually located behind the back panel in the freezer section of the refrigerator, and it is usually clipped onto the evaporator coil.
Get Social With us!
/ partsdr
/ parts_dr
Check out our appliance repair forum: forum.partsdr.com/
Check out our blog: partsdr.com/blog/
Subscribe to our KZread channel: kzread.info_c...
If you found this video helpful please click the thumbs up button and leave us a comment below.
#PartsDr #MakeAppliancesGreatAgain #Refrigerator

Пікірлер: 335

  • @jwil-pj2ye
    @jwil-pj2ye7 жыл бұрын

    Thank you for the video. I ordered a timer and a thermostat. the T Stat was busted open like the bad one you showed. Great video. This will be my second time replacing these 2 pieces. the first time was over 10 years ago and that time the fridge was about 7 years old. I'm hoping it last another 10 after this. $45 worth of parts saved me $1000.

  • @jollyscaria1922

    @jollyscaria1922

    2 жыл бұрын

    Bi metal time d forted th,, over lord realy set piont know all one by cheked temperch,,,,wir testng must be comper checking runing eazey but not reparing samll thing semples ok

  • @francom6230
    @francom62306 жыл бұрын

    You make the best videos. No frills, complete information & will sell me the parts.. Awesome!! Thank you.

  • @PartsDr
    @PartsDr Жыл бұрын

    Learn the differences between traditional and high limit defrost thermostats here: kzread.info/dash/bejne/m2iHsKeggNK7fbw.html Learn how to replace a defrost thermostat here: kzread.info/dash/bejne/d3hmpqd7mbS8fKg.html

  • @victordemoya2642
    @victordemoya26422 жыл бұрын

    Very very well explained, this is the best defrost thermostat video ever.thanks

  • @PartsDr

    @PartsDr

    2 жыл бұрын

    We are glad you found it helpful!

  • @zgwforum
    @zgwforum3 жыл бұрын

    Thank you kindly for your SPOT ON video regarding the defrost thermostat. Especially the decoding of the open and close temperatures. As a hint, ICE CUBES taken out of the freezer are typically about 0F. So if you have a second working freezer compartment, you can place the thermostat in the ice tray for 10 minutes, and then remove with this ice WITHOUT WATER to reduce the defrost thermostat temperature. To take the temperature, some meat thermometers do get down to 0f. Fortunately my digital volt-ohm meter was purchased with foresight and comes with a temperature probe. God Bless You and God Bless America.

  • @PartsDr

    @PartsDr

    3 жыл бұрын

    🇺🇸

  • @willfleischauer
    @willfleischauer2 жыл бұрын

    I have been an appliance service tech for 7 years now Still like watching these videos lol

  • @PartsDr

    @PartsDr

    2 жыл бұрын

    Thanks for watching. If you have any tips for us, let us know!

  • @justincalabrese7774
    @justincalabrese77743 жыл бұрын

    Thank you Ryan, thank you! My thermostat is EXACTLY the same as the one you showed, it was even blown up the same!

  • @PartsDr

    @PartsDr

    3 жыл бұрын

    Nice!!!

  • @martinlarsen3647
    @martinlarsen36477 жыл бұрын

    I've replaced many defrost thermostats that have had a blown top, but never really knew how to test them. Thanks Martin Larsen

  • @PartsDr

    @PartsDr

    7 жыл бұрын

    Glad we good help someone that has as much experience as you!

  • @keenanwimbley2143
    @keenanwimbley21436 жыл бұрын

    Great video. Thank a lot for explaining so clearly.

  • @PartsDr

    @PartsDr

    6 жыл бұрын

    Glad you found it helpful! =)

  • @johnny30806
    @johnny308064 жыл бұрын

    excellent video. simple and straight to the point

  • @PartsDr

    @PartsDr

    4 жыл бұрын

    Thank you! 😎

  • @madcowusa4277
    @madcowusa42772 жыл бұрын

    Good video. Whenever one of our fridges starts acting up around 8-12 years (icing/warm refrigerator usually) I replace all the main defrost components and put the unit into a rental. It's usually around $180 to do the timer, heating element, thermostat, cold control and maybe a cracked plastic door bin or two. Can't believe the cost of new fridges - used to buy basic rental property fridges for $249 vs. $1000 today. Too much printing of fake money.

  • @PartsDr

    @PartsDr

    2 жыл бұрын

    Very smart!

  • @bdkj3e

    @bdkj3e

    2 жыл бұрын

    Isn't it amazing how basic of an idea it is yet all our so called "experts" are always shocked when printing more money makes inflation go up lol.

  • @JohnTheMutt
    @JohnTheMutt5 жыл бұрын

    Great video! Very helpful in explaining the part #'s on the defrost thermostat! I have a defrost thermostat L47-22F 240386402 on an electrolux bottom freezer fridge (Model #EW28BS71IS9) and the top part is popped off partially like you show in the video. Again, that was very helpful explanation on why that happened! The heater element tests fine and hopefully the control board will be okay because it's hard to find details on this fridge! Thanks again for such a helpful video. :)

  • @PartsDr

    @PartsDr

    5 жыл бұрын

    Awesome! Glad you found it helpful 😀

  • @hectorfarias4373
    @hectorfarias43737 жыл бұрын

    hello, my mini fridge turns on but when it reaches the thermostat setting temp.... it won't turn back on. can this be a thermostat issue or something else?

  • @jerellluceno1615
    @jerellluceno16157 жыл бұрын

    what is the common problem of haire refrigerator not working on the motor compressor but the led light only flashing model 663w thanks

  • @yhelyheng2679
    @yhelyheng26797 жыл бұрын

    Hi can i ask a question about my mini samsung ref. I left my ref for 3months with doors open slightly when i came back and turn it on the compressor is just humming but no fan and not freezing, what may be the problem? Thanks

  • @kingisingh3879
    @kingisingh38797 жыл бұрын

    would a faulty thermol fuse in the freezer compartment affect the function of refrigerator side is there any link between the two. on the samsung RS21 JGRS model. i have had a brand new kit put on. still having defrost problem on fridge side. rechecked all the components for faults, they all good. Have been told it could be the pcb board not letting the heaters stay on long enough. is there anyway of checking my pcb board myself.

  • @truckerrespect7797
    @truckerrespect77972 жыл бұрын

    Very informative, thanks for giving us shade tree mechanics the info we need to make an educated diagnosis. Your vids are always very helpful

  • @PartsDr

    @PartsDr

    2 жыл бұрын

    We are glad you found it helpful!

  • @clemmtec9506
    @clemmtec95066 жыл бұрын

    Hi, I have a Ge double door, compressor works, Freezer fan works, the cooling fan in the back works the freezer is cool, and the fredge side is bearley cool. What should I do ? thanks

  • @hanahawlokam351
    @hanahawlokam3513 жыл бұрын

    Great video 😊 Thanks 😍

  • @skullhart
    @skullhart3 жыл бұрын

    Excellent. Thank you.

  • @30Thousand
    @30Thousand7 жыл бұрын

    Thanks for the bulge explanation. Now I know what to replace!!!

  • @PartsDr

    @PartsDr

    7 жыл бұрын

    We are glad to hear this helped you find the problem with your refrigerator!

  • @kermitpemberton3716
    @kermitpemberton37167 жыл бұрын

    great video

  • @wasimedo3877
    @wasimedo38775 жыл бұрын

    Very good 👍 job

  • @cpanta9343
    @cpanta93434 жыл бұрын

    Very clear. Thanks.

  • @PartsDr

    @PartsDr

    4 жыл бұрын

    We are glad you found it helpful! 🙂

  • @madisonvoss3512
    @madisonvoss3512 Жыл бұрын

    Great video, i will be ordering my part tomorrow!

  • @PartsDr

    @PartsDr

    Жыл бұрын

    Thank you!!

  • @Schnick74
    @Schnick746 жыл бұрын

    Thanks! This was exactly what was wrong with my Kenmore.

  • @PartsDr

    @PartsDr

    6 жыл бұрын

    Great to hear!

  • @MrTonyshit80
    @MrTonyshit808 жыл бұрын

    good lesson...tq for sharing..

  • @PartsDr

    @PartsDr

    8 жыл бұрын

    +MrTonyshit80 You're welcome!

  • @jamesortolano3983
    @jamesortolano39833 жыл бұрын

    Great info,thanks Next level!!

  • @PartsDr

    @PartsDr

    3 жыл бұрын

    Thanks! 👊

  • @41point2
    @41point27 жыл бұрын

    Hi Thanks for being here :). I just put in a defrost heater. It read 26 ohms before I put it in. When it came on the the defrost cycle. I could see through the vents it was glowing red. Then a few minutes later it turned off. Should I expect to see a "Glow". Thank you

  • @PartsDr

    @PartsDr

    7 жыл бұрын

    On some refrigerators the defrost heater will glow orange/red during the defrost cycle.

  • @jefferyantoine5551
    @jefferyantoine55518 жыл бұрын

    I am looking to get some type of training in small appliance repair. I am a certified HVAC Tech but I want to change careers. Any suggestion?

  • @thexxangel
    @thexxangel3 жыл бұрын

    You saved me money! , thank you very much

  • @PartsDr

    @PartsDr

    3 жыл бұрын

    That's great!

  • @jamesmullis6827
    @jamesmullis68278 жыл бұрын

    good explanation!

  • @PartsDr

    @PartsDr

    8 жыл бұрын

    +james mullis Great! We are glad you found it helpful!

  • @jeanlourenci
    @jeanlourenci4 жыл бұрын

    Great video. I changed my thermostat refrigeraror, but the refrigerator is still working constantly. The refrigerator it's very clean below. So what could be the problem?

  • @xonerate

    @xonerate

    4 жыл бұрын

    It is Possible that Your Defrost Timer or Switch is Stuck or Possibly Broken. @ the Top Right Corner of the "Fridge" there Should be a Plastic Set Screw, You can turn the Set Screw with a Flat Head Screw Driver. If I am not mistaken you can Turn the Screw "Gently" Clockwise until the Fridge Stops Running. If the Fridge does not Start Running After You shut it Manually, Then there most likely can be a Problem with Your Defrost Switch.

  • @raviyadav8743
    @raviyadav87437 жыл бұрын

    nice information

  • @tanglewoodliving6645
    @tanglewoodliving66459 жыл бұрын

    thx...good job!

  • @PartsDr

    @PartsDr

    9 жыл бұрын

    Tanglewood Living You're welcome! Thank you!

  • @souhachalhoub2240
    @souhachalhoub22402 жыл бұрын

    @Parts Dr Hi, first of all wish u a merry christmas and tks for this video. 2nd is the defrost thermostat stops the compressor and the fan on defrost cycle only or also when the ice is reachs its limit in the freezer too? My fridge is whirlpool model #3VET16GKBW00. I wld really appreciate ur answer 🙏

  • @saleembhutta704
    @saleembhutta7045 жыл бұрын

    Sir very nice video Hi how are you..sir my refrigerator not automatic off I did change timer and biometal..but not automatic off..what problem sir guide me I'm very upset about refrigerator....

  • @toddlemmon
    @toddlemmon2 жыл бұрын

    Ryan, my MAN! great video

  • @PartsDr

    @PartsDr

    2 жыл бұрын

    Thanks!

  • @lofenoialof5320
    @lofenoialof53206 жыл бұрын

    The thermostat and the heating element are good however the cooling problem persists. What else could it be ? Thanks

  • @NIKOSAUDIO1409888888
    @NIKOSAUDIO14098888882 жыл бұрын

    Hello from Greece I have a question. I have indesit ban 33 ND p and after a sort power down the 2 leds start blikin after few hours and after this no work properly I open the back of freezer and I see a lot ice if I check what you say maybe I find the problem? The fun works but no cool like the past. I try what you suggest and I hope to solve the problem.

  • @bonnieebrown
    @bonnieebrown5 жыл бұрын

    I wish I had seen this video a few hours ago. I just replaced my defrost thermostat after using the place-in-ice-water method, and I think it may not have been necessary. My timeline: my fridge was not getting cold enough. I realized it the day before going on a trip. I vacuumed the (very dusty) coils at the bottom, and the next morning the fridge seemed colder, but I thought I should order parts just in case. I ordered a heater and a thermostat. The fridge seemed to be operating normally when I returned from my trip, but I had the parts, so I thought I'd go ahead and dismantle the freezer and test the existing parts. My intention was to return both parts if the old ones passed the tests. I opened up the back of the freezer and there was no ice on the fins. I thought, great, the existing heater works! I cut out the thermostat, placed it in ice water, and didn't get continuity. So I decided to go ahead and put in the new thermostat. Because I'm not experienced with using a multimeter, I thought I'd test the new thermostat to see how the test should work. To my surprise, the new thermostat also failed the test! Stumped, I thought I might as well install the new thermostat, since I had opened the package and couldn't return it. My fridge is now gradually cooling off. Now I have seen your video, and can attest to your statement that the place-in-ice-water method of testing is not adequate. I'm going to let the site from which I bought my parts know about my experience. I cleaned the fridge thoroughly, so at least now I have a nice clean fridge to show for my efforts.

  • @bonnieebrown

    @bonnieebrown

    5 жыл бұрын

    I would like to add that the temperature rating on both thermostats is L8.9-16.7C. Converting to fahrenheit, that's 48.02-62.06.

  • @PartsDr

    @PartsDr

    5 жыл бұрын

    Sorry to hear about the incorrect information you were provided before you found this video. We specifically made this video because we had our own customers contacting us thinking their new defrost thermostat was bad when it actually was just bad information that was provided to them on how to test the part. If the refrigerator still doesn't cool down, it is sounding like you may have a refrigerant leak in the sealed system of the refrigerator.

  • @bonnieebrown

    @bonnieebrown

    5 жыл бұрын

    @@PartsDr Thank you for your reply. Fortunately, my fridge is cooling down as I hoped. I really appreciate your thorough video.

  • @tavy7200
    @tavy72003 жыл бұрын

    Hello,can you help me ?I bought used viking VCFF036SS fridge for repair. I opened the back panel and I saw the smoke pipe left side of compressor have small hole and the right side of the compressor the tiny pipe it's broken, when I contacted the fridge the fan turn on ,the light turn on and that it. I think the fridge have another problem... What I have to do? Or it's better to sale for parts etc.. What I have to do? Thank you!

  • @wasimedoo7994
    @wasimedoo79942 жыл бұрын

    Very good information bro

  • @PartsDr

    @PartsDr

    2 жыл бұрын

    Thanks!

  • @jacksdad2626
    @jacksdad26265 жыл бұрын

    Great video. I replaced both the defrost timer and defroster thermostat on my Hotpoint freezer refrigerator with the freezer located on top. Originally the refrigerator is not cooling. Now the refrigerator and freezer are working fine but I constantly hear the fan on and the back of the refrigerated which means they're refrigerated is not turning off. Any suggestions please help

  • @PartsDr

    @PartsDr

    5 жыл бұрын

    The fans are controlled by the cold control thermostat. First set the temp controls to the middle factory settings. Then wait 24 hours; opening the doors as little as possible. Next, check to make sure the refrigerator and freezer are cooling to the proper temps (37F Fridge section, 0 Freezer section). If you aren't getting those results then the cold control thermostat is most likely bad and needs to be replaced.

  • @richeyrich6855
    @richeyrich68554 жыл бұрын

    Thank You!

  • @PartsDr

    @PartsDr

    4 жыл бұрын

    We are glad you found it helpful!

  • @LongNguyen-mu7bb
    @LongNguyen-mu7bb3 жыл бұрын

    Great video thanks

  • @PartsDr

    @PartsDr

    3 жыл бұрын

    We are glad you found it helpful!

  • @hansoll5126
    @hansoll51262 жыл бұрын

    Hello, Our fridge is a Whirlpool Gold side by side and the fridge starts clicking and seems to go defrost mode a lot lately. It still cools ok in both parts of the fridge. It shows digital instead of 2 to 15 and fridge side 39 to 46 and then it snaps out of it and is back to 2 and 39. Can this be the defrost sensor? I ordered a new condensor motor/fan but suspect since the fan seems to run when its not in defrost mode its not the broke part. I notice when I press the quick cool button the thermostat numbers switches to freezer -6 and 34 fridge and it truly cooling like shown. Thank you for any advise.

  • @fireman5363
    @fireman53639 жыл бұрын

    Good video!!

  • @PartsDr

    @PartsDr

    9 жыл бұрын

    FIREMAN We are glad you found it helpful!

  • @PlayDohMagic
    @PlayDohMagic5 жыл бұрын

    great video!!! freezing it instead of cold water!!!

  • @wazimedoo3067
    @wazimedoo30674 жыл бұрын

    Very good 👍

  • @PartsDr

    @PartsDr

    4 жыл бұрын

    Thanks 🙂

  • @ITIdude1
    @ITIdude12 жыл бұрын

    My freezer has black dirt in it and after that my fridge stopped working well after some weeks. Is black dirt that suddenly appeared a symptom of a bad defrost thermostat like it blew out?

  • @robertchall8576
    @robertchall85764 жыл бұрын

    verry good info.

  • @PartsDr

    @PartsDr

    4 жыл бұрын

    We are glad you found it helpful! 🙂

  • @arnoldparkinson1419
    @arnoldparkinson14196 жыл бұрын

    Good info.

  • @PartsDr

    @PartsDr

    6 жыл бұрын

    We are glad you found it helpful!

  • @melikey4398
    @melikey43989 ай бұрын

    Thank you super helpful i have one question what if the thermostat is between the 55 and -15 should there be continuity or not? Thank you for any help

  • @PartsDr

    @PartsDr

    9 ай бұрын

    It would depend on the temperature of the thermostat.

  • @gcflstaff3515
    @gcflstaff35154 жыл бұрын

    Thanks.... good video 👍💪

  • @PartsDr

    @PartsDr

    4 жыл бұрын

    😁

  • @gregkosinski2303
    @gregkosinski23035 жыл бұрын

    Ha he sounds like that dude on Better Call Saul. The one who the the flamed our H2 with spinners.

  • @ferlinsov
    @ferlinsov5 жыл бұрын

    Wow !!! Amazing video , you guys rock !!!

  • @PartsDr

    @PartsDr

    5 жыл бұрын

    Glad you found it helpful 😁

  • @leemason4024
    @leemason4024 Жыл бұрын

    Thanks for your videos AND advice!

  • @PartsDr

    @PartsDr

    Жыл бұрын

    You're welcome!!

  • @condor5635
    @condor56357 жыл бұрын

    Awesome video.. I understand the 55 degrees or higher there is no continuity. This is the case where the heater element has been on for several minutes and the thermostat opens to cut off the heater. I also understand the low end number which is the typical case where the defrost timer kicks in and the thermostat is like way down near zero or better degrees and the circuit is closed so the heater is safe to turn on. What I don't understand is what's going on with continuity in the middle range between 20 and 55 degrees? I am assuming the thermostat is closed allowing the heater to work until 55 degrees is reached. So why the 20 degree figure? Why not just have one figure - open above 55 and closed below 55 degrees?? Thanks for explaining. Great video once again

  • @PartsDr

    @PartsDr

    7 жыл бұрын

    Great question! It is because the manufacture does not want the thermostat to open and close at the same temperature. What happens in the middle depends on whether the thermostat is in an open or closed state. For instance with the numbers you provided, if the thermostat is at 37F it could be opened or closed. If the thermostat has already down to 20F or colder and it is closed and it has warmed up to 37F then it would be closed because it hasn't warmed up to the 55F to open. If the thermostat has opened by warming up above 55F, then the thermostat cooled down to 37f, it would still be open at 37F because it hasn't reached the closing temperature of 20F.

  • @condor5635

    @condor5635

    7 жыл бұрын

    Thanks for the great reply totally explained it well. I had an interesting way of checking my heater defrost element sticking my Fluke temperature probe in a screw hole down near the heater element which allowed me to see the temperature go up to 108° verifying that the heater cycle was working correctly without taking off the entire panel which is a real pain in my GE fridge. Love those Fluke instruments Thank you

  • @wyocoyotewyocoyote9007

    @wyocoyotewyocoyote9007

    5 жыл бұрын

    @@PartsDr this reply really helped....but still need a bit of clarification. I have 25-47F Bimetal Tstat,connected to my Ohm meter from below freezing warming up it switches from continuity to no continuity right around 25 F (according to my digital temp sensor tool )so from closed to open circuit as temp hits to 25. Then it will stay open if it goes up and past 47F and not close the circuit again until it drops past 47?

  • @PartsDr

    @PartsDr

    5 жыл бұрын

    ​@@wyocoyotewyocoyote9007 Most bimetal defrost thermostats that we have seen open at the higher temp rating and close at the colder temp rating. So if yours worked that way it would open at 47F and close at 25F. These are general rules and each manufacturer can do things differently if they want to. From the results you got it sounds like yours opens at 25F and closes at 47F and should be just fine as long as it works that way consistently.

  • @rodolfocalderon9861
    @rodolfocalderon9861 Жыл бұрын

    Muchas gracias

  • @PartsDr

    @PartsDr

    Жыл бұрын

    You're welcome!

  • @josemontanez3034
    @josemontanez30345 жыл бұрын

    Good video I like it

  • @PartsDr

    @PartsDr

    5 жыл бұрын

    Thanks!

  • @arielperezcarvajal7957
    @arielperezcarvajal7957 Жыл бұрын

    Very good

  • @PartsDr

    @PartsDr

    Жыл бұрын

    Thank you!

  • @duruikejohn3844
    @duruikejohn38444 жыл бұрын

    I have open the component up in the freezer n what see is evepartor full of ice

  • @MagicGuitara
    @MagicGuitara8 жыл бұрын

    Thanks for the explanation. there are two Thermostat in my fridge (Amanna)' one is L55-35F and L90-45F. why two?

  • @PartsDr

    @PartsDr

    8 жыл бұрын

    I believe the 2nd defrost thermostat on those refrigerators was used to control when the freezer fan turns on. You will want to check the wiring diagram to be sure.

  • @MagicGuitara

    @MagicGuitara

    8 жыл бұрын

    Thanks! I have checked the wiring diagram. the fan is connected separately. the L55-35f is connected in series withe the positive line and to one end of the heater and the L90-45F is connected in series to the negative (0) line and to second end of the heater.

  • @InnovativeShooter
    @InnovativeShooter8 жыл бұрын

    Hi, In May of this year. I had a "DEF" flashing off my GE Profile door monitor. I got a thermostat and a thermostat timer from Appliance Part Co. in Tempe, AZ. Installed them both and after a day "Def" flashing came back and ever since I just unplug and plug it back on. Today I decided to pull the back panel again and manually turn the defrost on thru the timer. I heater came on. I dbl checked the thermostat and to my surprise the the numbers on the replacement part is L140-30F. That says an opening of 140 and a closing of 110 degrees F. Is that why I am having a problem. I am going back tomorrow to that parts store. I appreciate your feed back. Thank you.

  • @PartsDr

    @PartsDr

    8 жыл бұрын

    Some newer GE refrigerators use the defrost thermostat as a high temperature safety and they use a control board and thermistor to monitor the temperature of the evaporator coil to tell the control board when to end the defrost cycle.

  • @duruikejohn3844
    @duruikejohn38444 жыл бұрын

    Hi please I need help a nonfroze refrigerator am working on product Hisense doorbell door freezer and fridge the up side is the freezer is working but fridge is not

  • @glennsharp8276
    @glennsharp82766 жыл бұрын

    I wanted to ask you my closed is L60-32= 28 degrees for a closed circuit. Wr50x10090 is only putting out 2.7 of resistance when I check. I noticed yours was like 6.5. Is 2.2-2.7 at like 18degree ok? I also checked the heater element it was like 40-50 ohms. I have the G.E. GBSC0HCXCRBB

  • @PartsDr

    @PartsDr

    6 жыл бұрын

    Yes that is a good reading. We would recommend to replace the defrost control board PD00023371 (WR55X10837) and the defrost thermostat PD00023359 (WR50X10090) at the same time. Also make sure to manually fully defrost the evaporator coil before turning the refrigerator back on. partsdr.com/part/wr55x10837-control-board/#model-GBSC0HCXCRBB partsdr.com/part/wr50x10090-defrost-thermostat/#model-GBSC0HCXCRBB

  • @16352huey
    @16352huey2 жыл бұрын

    Awesome!

  • @PartsDr

    @PartsDr

    2 жыл бұрын

    Thanks!

  • @heidimuller7506
    @heidimuller75064 жыл бұрын

    If the descriptions says L55-35F what is happening between 55 and 20 ? is it partly opened/closed? What does that mean?

  • @PartsDr

    @PartsDr

    4 жыл бұрын

    I think your question was answered in this previous comment here: kzread.info/dash/bejne/aZ-X2M6nh5u3idI.html&lc=UgjZLaZ4FiJM6HgCoAEC

  • @harmindersingh-yx8bt
    @harmindersingh-yx8bt7 жыл бұрын

    Hello dear sir l serviced freezer its temprature reading is -18 to -26 .its full cover with ice so i seviced what it is not show proper temprature -18 to -26.it show only -16. what is fault in this machine.

  • @jaiho314

    @jaiho314

    5 жыл бұрын

    Singh ji did you defrost the ice first?

  • @rickeykeeton4770
    @rickeykeeton47706 жыл бұрын

    I have one I checked with meter set to sound. Checked good. But when I set meter to Auto, I get a high reading of resistance. Does the bi-metal in the stat ever lose or gain resistance? This fridge was freezing over. Df element checks good. I have yet to check the timer. If I turn the timer to defrost and the heater comes on and goes off in the time it is supposed to, can I trust the stat is wirking properly, or are they like dryer thermostats that might check okay when ohmed but still be faulty?

  • @PartsDr

    @PartsDr

    6 жыл бұрын

    Yes it is possible for moisture to get inside the thermostat and cause it to make a poor connection. If you suspect it might be bad, we would recommend to go ahead and replace it.

  • @russantkowiak4205
    @russantkowiak42058 жыл бұрын

    I have been sweating over my used "patio fridge" (Amana) for a couple of weekends now. The evaporator fan did not work with the door open, but when I pulled it out it tested fine. Then I started looking at the defrost thermostat, and was just fixing to dangle it in a cup of ice water. Noticed that it was bulged like in your video, so I will order one and see if that was the problem. My other plan was to buy a different fridge from Craigslist.

  • @PartsDr

    @PartsDr

    8 жыл бұрын

    Hi Russ, It sounds like replacing the defrost thermostat should probably take care of your problem.

  • @carlostrejo8699
    @carlostrejo86993 жыл бұрын

    great video and very educational. My kenmore side by side fridge is in the garage and the evaporator fan keeps running. I've done the diagnostic checks to include forcing the heater to come on. The whole time I was in diagnostic mode, the evaporator fan was on. It seems like the thermostat is the problem but I can't be sure until I open it up and inspect the thermostat. What else do you think might be the problem?

  • @PartsDr

    @PartsDr

    3 жыл бұрын

    What is the model number of the refrigerator?

  • @carlostrejo8699

    @carlostrejo8699

    3 жыл бұрын

    @@PartsDr 10656573400

  • @PartsDr

    @PartsDr

    3 жыл бұрын

    @@carlostrejo8699 The fan motor is probably controlled by one of the control boards on your refrigerator. It could run constantly if it isn't cooling cold enough.

  • @carlostrejo8699

    @carlostrejo8699

    3 жыл бұрын

    @@PartsDr well....that's the peculiar thing, it is cooling. I thought the temp control was set too low thinking it might be trying to reach that temp that it can't so I raised it a couple of degrees. Factory set is 37F, it was set at 33. There is frost on the bottom of the back panel in the freezer and that's why I think it might be the thermostat. I'm open to more advice. thanks

  • @carlostrejo8699

    @carlostrejo8699

    3 жыл бұрын

    is there a way to determine inside temperature without a heat gun?

  • @maykaylarobinson3050
    @maykaylarobinson30506 жыл бұрын

    My refrigerator is warm ( side by side fridge/freezer) my freezer isn't freezing food anymore what could that be?

  • @geo745don
    @geo745don7 жыл бұрын

    if the thermostat is New and never been tested. when testing it at room temp should there be continuity or should it be a open circuit

  • @PartsDr

    @PartsDr

    7 жыл бұрын

    It depends on the temperature rating of the thermostat. Some should be open and some should be closed.

  • @awakeOsleeper7
    @awakeOsleeper76 жыл бұрын

    Awesome and informative video! Mine reads L140-30F so using your example it opens at 140F degrees and closes at 110F degrees? Does this seem right? It seems very hot compared to the example you gave. Please help!

  • @PartsDr

    @PartsDr

    6 жыл бұрын

    Yes that would be correct. Defrost thermostats that have a high temp rating like that one are usually a backup safety in case the defrost thermistor or control board fail and it gets too hot. It would prevent the refrigerator from overheating or starting a fire.

  • @cu0ngpitt
    @cu0ngpitt3 жыл бұрын

    Wow the info I was looking for! I know this isn't a forum but just to get a clear understanding. My thermostat is rated at 14.4 - 22.2C. So no continuity at room temp (approx 70F) then threw the thermostat in the freezer which was reading at at 0C. Checked and I had continuity, this means I have a bad thermostat?

  • @PartsDr

    @PartsDr

    3 жыл бұрын

    It sounds like it is working properly from your test results. This thermostat should open after warming up to 58F and close when it cools down to -14F.

  • @cu0ngpitt

    @cu0ngpitt

    3 жыл бұрын

    @@PartsDr Thanks I made a mistake on the conversion. Mistaking C for F. I believe you are right, thermostat is okay. Do you have any videos on how to test my defrost adapter controller?

  • @johnhenson757
    @johnhenson7574 жыл бұрын

    GE IC360NMARH Bottom freezer. The original Evap Thermodisc L65 - 20F while its replacement WR50X10030 L140-30F. Does not seem that these sames parts could operate the same in the freezer and be a suitable replacement. Can i expect the new part to operate satisfactorily? Glad i found your site on KZread.

  • @PartsDr

    @PartsDr

    4 жыл бұрын

    We can think of a few possible reasons the new and old thermostats would have such different temperature ratings. 1. Someone replaced the thermostat at some point in time with something other than the OEM part. 2. GE made a design change to the part. 3. GE has the wrong part number listed for your model refrigerator. It might be best for you to contact GE directly to see if they can clarify what the correct temperature rating for this part should be on your refrigerator. Our records indicate WR50X10030 should be L140-30F.

  • @remediusfernandes1570
    @remediusfernandes1570 Жыл бұрын

    Thanku sir

  • @PartsDr

    @PartsDr

    Жыл бұрын

    You're welcome!

  • @BY-bj6ic
    @BY-bj6ic2 жыл бұрын

    thanks

  • @PartsDr

    @PartsDr

    2 жыл бұрын

    You're welcome!

  • @aksnowjunky
    @aksnowjunky3 жыл бұрын

    Quick question. How would you interpret a bimetal/thermodisc labeled F42-32F? Does it work differently as in closed when above 42 degrees and stays closed then cuts open at 10 degrees? This part is wired in series with a cold control thermostat, not a defrost heater.

  • @PartsDr

    @PartsDr

    3 жыл бұрын

    That should open at 42F and close at 10F. Sometimes a bi-metal thermostat is used to turn a fan motor on/off at a certain temperature.

  • @aksnowjunky

    @aksnowjunky

    3 жыл бұрын

    Thanks for the reply. I thought this too but if it opens back up at 42*F then the unit wouldn’t cool if wired in series with a cold control. This bimetal has specs different than most fridge bimetals. Would you like to take a look at this GE fridge wiring diagram and see if you can make sense of it’s operation? It has no actual defrost circuit and instead lets frost thaw while the thermostat & bimetal are open. imgur.com/a/8IINMov

  • @akumathelion535
    @akumathelion5353 жыл бұрын

    My multimeter doesn't have a "continuity setting" (with the symbols shown on yours). It does have all the other stuff.What exactly should I set it to? I thought continuity was ohms? Tested the heater and it was 29.4 ohms. So I'm thinking it's the thermostat even though it looks fine. I guess I'll have to turn it back on without the heater and thermostat and leave it in the freezer to get it cold. Mine has no numbers on it though to say how cold or warm it needs to be.

  • @laurenceperkins7468

    @laurenceperkins7468

    3 жыл бұрын

    Continuity and ohms are functionally the same thing, but the continuity setting is a lot less picky about ranges and often has a beeper attached so you don't have to look at the meter. Ohms will do if your meter really doesn't have one.

  • @BlackCatSyndicate
    @BlackCatSyndicate3 ай бұрын

    Does this and the hearer element run 120v AC or is it converted to DC? Glass heater element was burned up, but after 30min im not sure its workinf as the tube isnt warm.

  • @PartsDr

    @PartsDr

    3 ай бұрын

    All of them that we have seen so far have run off of AC voltage. The heater is only turned on periodically to melt the frost, it does not heat continuously.

  • @jeffcecchini8803
    @jeffcecchini88036 жыл бұрын

    I have a Sears Kenmore Fridge with Freezer on top model# 253.6480240C. Found that food was partially defrosted in freezer. The freezer temp is only 32F and the fridge temp is only 48F. I used a screwdriver to manually advance the defrost timer and that did turn on/off the the sound of what I believe to be the compressor as well as the freezer fan. Turning the fridge temperature control knob from lowest setting (left) to highest setting (right) also turns on and off the same sound. I clamped my multimeter on to the red wire near the compressor and it read ~ 1.6 amps when I believe the compressor is running. The freezer fan is definitely rotating as cold air is being pushed out of the freezer vents. I removed the freezer evaporator cover and confirmed the fan is rotating. There was a 3/4 x 2" chunk of ice on the tube (that does *not* have the thermostat attached to it) right near the fins of the evaporator, otherwise, no real icing in the freezer. The defrost heater element has continuity. I am suspecting the defrost thermostat. I don't want to cut the wires just to test unless I'm on the right track. Is this the next likely culpret that should be tested? Any advice?

  • @PartsDr

    @PartsDr

    6 жыл бұрын

    Hi Jeff, it sounds like you probably have a refrigerant leak. Usually if you are only getting a small section of the evaporator coil that gets frost/ice on it, that is and indicator that there is a leak in the sealed system. This type of repair is expensive and must be done by a professional so it might be better to replace the refrigerator.

  • @jeffcecchini8803

    @jeffcecchini8803

    6 жыл бұрын

    Thank you so much for your quick reply, even though it doesn't sound good for me :-) Given the likelihood of what's wrong, would it be beneficial to cut the thermostat and test it on the off chance that it is stuck on which would cause the defrost element to be on more than it should driving up the temperature inside the freezer/fridge somewhat? Or would it not work that way or have that effect? Thinking of a last ditch effort?

  • @jeffcecchini8803

    @jeffcecchini8803

    6 жыл бұрын

    I cut out the thermostat and checked for continuity >47F and it was open as expected. I put it in a working freezer for a few hours and just checked it and it was closed, as expected for

  • @PartsDr

    @PartsDr

    6 жыл бұрын

    The only thing we are aware of that can cause that type of problem is a sealed system problem. Unfortunately you will probably have to replace the refrigerator.

  • @jeffcecchini8803

    @jeffcecchini8803

    6 жыл бұрын

    Thanks, we did buy one.

  • @tylerdowns8191
    @tylerdowns81913 жыл бұрын

    I was having the symptoms of a broken thermostat - icy coils and warm refrigerator. I noticed the defrost thermostat was popped up like in the video, but it does have continuity when cold. I went ahead and replaced it. Hoping it solves the problem, but I’m not sure if it will.

  • @PartsDr

    @PartsDr

    3 жыл бұрын

    Our guess is that it will fix your problem. Either way, if it is popped up, it needs to be replaced.

  • @tylerdowns8191

    @tylerdowns8191

    3 жыл бұрын

    Follow-up a month later - it does appear that replacing the thermostat fixed my refrigerator.

  • @PartsDr

    @PartsDr

    3 жыл бұрын

    @@tylerdowns8191 That is great!

  • @jags132section
    @jags132section3 жыл бұрын

    Thank you for the excellent video.. as usual. My thermostat has 100% continuity..doesn't that mean that it's in constant defrost mode? However the evaporator still ices up while my heater, sensor and fan are fine thanks to your excellent testing videos. Is it possible that although the defroster shows constant continuity, that it's just totally bad and the control board is not getting any signal to turn on the heater(even tho as mentioned) the heater should be on constantly....thank u in advance for any reply...

  • @PartsDr

    @PartsDr

    3 жыл бұрын

    It sounds like your defrost thermostat is probably a high limit safety thermostat. It only cuts out if the evaporator coil gets too hot to prevent a fire.

  • @jags132section

    @jags132section

    3 жыл бұрын

    @@PartsDrthanks so much for quickly replying.... I'm not sure..i immersed it in a cup of my faucet hot water 140° left it in fir 10min n still had continuity...

  • @PartsDr

    @PartsDr

    3 жыл бұрын

    @@jags132section Some safety thermostats have an opening temperature over 140F.

  • @user-hm1cq9wr2o
    @user-hm1cq9wr2o Жыл бұрын

    CORRECT Info, GREAT video! Question: I just replaced a defrost thermostat (it lasted one year) - it was a 48 - 18 = 30; the new one I put in was 48 - 30 = 18. Any idea if this new thermostat will work, or should I go ahead and order one like I just removed? My unit is an old Top Freezer Roper RT18BKXKQ03. PS: I can't find the specific specs for what the thermostat specs should actually be. THANKS!

  • @PartsDr

    @PartsDr

    Жыл бұрын

    This is the correct defrost thermostat listed for your model here: partsdr.com/part/4387490-defrost-thermostat?model=RT18BKXKQ03 It has a rating of L6.7-14.5C. It is always a good idea to make sure to use the correct defrost thermostat for your model as the incorrect thermostat can cause it to not work properly or in some cases it could be a fire hazard.

  • @user-hm1cq9wr2o

    @user-hm1cq9wr2o

    Жыл бұрын

    @@PartsDr THANK YOU very much for addressing this issue! You're awesome!

  • @CommonSenses101
    @CommonSenses1012 жыл бұрын

    Is defrost thermostat interchangeable, C to F or vice versa? For example, my original defrost thermostat uses F, if I replace with new one with C, will it still work? Or I have the same version F? I have replaced start relay, capacitor, defrost thermostat and defrost sensor Added new freon. My Kenmore bottom freezer refrigerator still does not work. The temperature is 57 F for the fridge, 27F for the freezer after 1 1/2 days.

  • @PartsDr

    @PartsDr

    2 жыл бұрын

    As long as the temperature rating is the same, it doesn't matter if the temperature is listed in Fahrenheit or Celcius.

  • @Mecambrea77
    @Mecambrea776 жыл бұрын

    Bimetal sometimes pass the continuity test , but the contacts dont hold when the heater comes on, so the continuity test is not 100% reliable, I learn with experience whenever I replace the timer or heater I also replace the bi metal tio avoid recalls

  • @PartsDr

    @PartsDr

    6 жыл бұрын

    Yes, this is good advice. We recommend the same thing.

  • @andromedaandrade889

    @andromedaandrade889

    Жыл бұрын

    Exactamente, así pasa. Se puede ver en buen estado el termostato de descongelamiento, pero es mejor hacer una prueba con la carga ( resistencia, foco,etc,) para ver si logra encenderlos, obvio también con su respectiva medición del voltaje que de a su salida.

  • @andromedaandrade889

    @andromedaandrade889

    Жыл бұрын

    Saludos desde Sinaloa, México

  • @shaneharr9404
    @shaneharr94046 жыл бұрын

    The defrost thermostat for my kenmore fridge has this sequence of characters on it. L8.9-16.7C. Converting to Fahrenheit it comes to L48.02-62.06F. This seems backwards in that the first number is lower than the second number and the close temperature calculates to -14.04F. What is wrong here?

  • @PartsDr

    @PartsDr

    6 жыл бұрын

    That is correct. The closing temp can be very cold because it is attached to the evaporator coil which gets cold enough to close the thermostat.

  • @southpark4151
    @southpark41513 жыл бұрын

    Nice video clip. So - after watching this video - this device is electrically connected in series with the heating element right? So if the temperature gets above a certain temperature ----- then the device becomes an open circuit ------ which prevents any more heating until the next defrost cycle occurs, right?

  • @PartsDr

    @PartsDr

    3 жыл бұрын

    Yes that is correct!

  • @southpark4151

    @southpark4151

    3 жыл бұрын

    @@PartsDr Thanks very much!!!

  • @bevjacquez
    @bevjacquez3 жыл бұрын

    Our Samsung French Door Refrigerator bottom freezer bimetal defrost thermostat doesn't seem to have any "L" numbers, only 100 10 and 60 / 40. What do those numbers mean? Also, at room temperature it had a continuous beep when we put it on the ohm meter. We're trying to figure out why the bottom freezer fluctuates in temperature between 0 degrees and even up to 30 degrees. Ice cream is soft and ice is slippery.

  • @PartsDr

    @PartsDr

    3 жыл бұрын

    The bi-metal thermostat on Samsung refrigerators is usually a high limit safety that only kicks in if the main control board or temperature sensor fails. It will usually have an opening temperature of 100F+.

  • @stevedrinkwater7202
    @stevedrinkwater72027 жыл бұрын

    my freezer works and I removed the cover to expose the coils. They had some frost but not much. I defrosted them anyway. The frig is still not cooling. what next?

  • @jamesharrison8406

    @jamesharrison8406

    3 жыл бұрын

    one time i remember finding an electric damper motor not working properly... make sure that the opening between freezer and ref section is open and not blocked somehow.

  • @craighicks1399
    @craighicks13995 жыл бұрын

    We're testing our defrost thermostat. At room temperature it's reading 0.00 for continuity. We bought a new one thinking the old one was broken. It also reads 0.00 at room temperature. Visually they both look fine. Is our multimeter not working correctly or are we crazy?

  • @PartsDr

    @PartsDr

    5 жыл бұрын

    What is the part number?

  • @druiz607
    @druiz607 Жыл бұрын

    my multimeter in the continuity setting showed 001 after the thermostat was in the freezer for a few minutes. The same reading as when I touch the probes together. Is this saying that the thermostat is good?

  • @PartsDr

    @PartsDr

    Жыл бұрын

    That sounds like a good reading from what you are describing. You could let it warm up to room temperature to verify that it opens up when it warms up.

  • @TheTor
    @TheTor Жыл бұрын

    Hi there. My current defrost thermostat states L175 - 20F. What would the opening and closing temperatures be with those figures? I don't think that 175 degrees would be the opening temp LOL! ;O). Thx for the great video!

  • @PartsDr

    @PartsDr

    Жыл бұрын

    Th defrost thermostats with a higher opening temperatures like yours are a safety device in case the main control board and temperature sensor don't properly regulate the temperatures on their own.

  • @billholder46
    @billholder463 жыл бұрын

    Here’s a ? For you, my freezer will run but when it shuts off it will not come back on and I get a high temp alarm. Is that caused by the defrost thermostat, or the regular thermostat? I thought it was the capacitor and control on compressor and replaced those, though tho old capacitor checked okay. What’s my problem?

  • @PartsDr

    @PartsDr

    3 жыл бұрын

    That type of problem wouldn't be caused by a bad defrost thermostat from our experience. It could be caused by a bad cold control thermostat.

  • @martinsmythe3414
    @martinsmythe34146 жыл бұрын

    Could either of these items stop the defrost timer from advancing.

  • @PartsDr

    @PartsDr

    6 жыл бұрын

    No, not that we are aware of.

  • @hollisterthompson7813
    @hollisterthompson78134 жыл бұрын

    If the new thermostat has a different wiring code, does it matter how you make the connection?

  • @PartsDr

    @PartsDr

    4 жыл бұрын

    On most refrigerators it does not matter which of the two wires from the thermostat goes to which of the two wires in the refrigerator.

  • @EvendimataE
    @EvendimataE4 жыл бұрын

    what will happen if not the right specs is installed...like my bad thermostat is hotpoint and i plan to replace it with my spare thermostat from frigedaire?

  • @PartsDr

    @PartsDr

    4 жыл бұрын

    It is best to replace the thermostat with an exact match OEM part. Installing one with the incorrect rating could damage the refrigerator or be a fire hazard.

Келесі