How to solve the problem of the air conditioner dripping water inside the room
The air conditioner drips water inside the room:
This problem is common in air conditioners, and many homeowners face the problem of water dripping from the air conditioner into the room (water dripping), as most of these problems and malfunctions in air conditioning require a lot of assumptions before carrying out the maintenance process, so you must determine your expectations before starting to solve the problem.
1- The water drainage line is blocked
If the drain pipe is clogged with dirt, dust, or mold, water will collect in it and not come out, causing water to back up into the house. The need here is to blow forcefully into the pipe to clean it completely, then turn on the air conditioner and check it again.
Note: The drain pipe is a plastic pipe that connects to the indoor unit of the split air conditioner. It goes outside the house parallel to the copper line that carries cool air from the outdoor unit.
2- Keep the air conditioner away from the wall
How to install a split air conditioner and the required dimensions
3- The drain pan is damaged or full
The drain pan may become damaged or corroded after several years (10-12 years) of use of the air conditioner. When water falls into this basin, it causes rust, which ends up damaging the drain pan. To solve this problem, the drain pan must be replaced.
Remove the front cover of the air conditioner.
Open the drainage hole in the bottom of the pot and set aside. Locate the filter bowl, and store it away from damp areas.
Wash and dry the leaves well. Use water and a damp cloth to remove any dirt or dust found between the leaf veins.
A dirty air filter causes the air above the evaporator coil to freeze, so the air cools the evaporator coil to the freezing point, so the ice melts and drains excessively, so that the drain pans cannot handle the excess water. If the air filter is washed and cleaned every three months, or according to the recommended ratio, it will be able to drain effectively. Use the conditioner by:
Remove the front indoor unit cover.
Next, remove the filters (after reviewing the compressor user manual).
Wash the filters under running water (using the kitchen tap).
Leave the filters in the air conditioner until they dry and then put them back in.
5- Low coolant level
If there are no other reasons for this, you should check the coolant level. If there is insufficient refrigerant in the AC system, it may cause water to freeze in the evaporator coils. When this happens, the antifreeze will melt, and it will overflow into the drain pan. Then the drops fall out of the chamber. Low refrigerant occurs when refrigerant leaks into the air conditioner, causing the amount of gas to decrease.
Test it using a standard watch for that, or if you don't have one, you need to go to a professional service technician.
Пікірлер: 27
مشكور اخي ..نحن بانتضار الجزء الثاني بخصوص مكيف جيون
بارك الله فيك على شرح والله صفحتك تستاهل ملايين من الاشتراك الله يرحم والديك وجزاك الله خير
شكراً لك وبارك الله فيك اخي الكريم ماذا يرمز رمز الخطأ E2 في مكيف kiowa وشكرا مسبقاً
شكرا 🇩🇿🤝
شكرا
مكيف فيه 560 g ou wahed fih 700 g هل لي يرفد الغاز كثر هو لي قوي ويبرد كثر؟ فهمني فهاذي اذا تكرمت مع العلم في زوج غاز 410
السلام عليكم ممكن اخي الكريم شرح أو رايك في الوافد الجديد المكيف nardi
@Asrar-1001
Ай бұрын
احسن مكيف في الجزائر بعد مكيف LG
كيف حبس الغاز في مكيف كوندور انفرتر
كيفاش نخرج الماء من المكيف ؟؟
انا مايقطرش الما الا كي نديرو في 16 و يطول كي نطفيه يقطر من اللور .مالحل Hisense
عندي مكيف يقطر مل وحدة خارجية من وحد الفتحة عادي؟
عندي مكيف مكس ويل يخرج ماء من و مرا ت يكون مكيف يخرج حرارة ماسبب
سلام عليكم
حل آخر خويا تقدر تثبت تعليقي ملقيتش تورنيفيستمص ولا تنشع لما لي ف تيو للبرا بلا متحل
شريت جديد lg قطر الماء فالغرفة و بعدها طفا و مابغاش يشعل
اخي هل الوحدة الخارجية تكون t3 والوحدة الداخلية t1 ولا الإثنين يكونو نفس النوع ارجو الرد
@Asrar-1001
27 күн бұрын
قصدك الكتابة
@nadir8466
27 күн бұрын
@@Asrar-1001 نعم اخي الكتابة... عندي في الوحدة الداخلية مكتوبة t1 وبطاقة المعلومات في الوحدة الخارجية ممحية، يعني تكون t1 مثل الوحدة الداخلية ولا t3
عندي مكيف سامسونق 1200 t3 ركبناه في غرفة 5 علي 4 عند ارتفاعدرجات الحرارة يحبس بالاخص منتصف النهار وفي الليل يمشي نورمال احضرنا اختصاصي لفحص الغاز والكهرباء وقال كل شئ ممتاز ولم يعرف اين المشكل تابعت الكثير من الفيديوات ومعضمهم تحدثو عن المكثفة ارجو النصيحة والتوجيه لوجه الله وشكرا ارجو الرد
@momokoko3095
27 күн бұрын
خوي من كلامك ممكن ماكونش t3
نحي هاذيك الكتبة ماشفنا والو
@Asrar-1001
23 сағат бұрын
هذيك ترجمة انت الي مفعلها في يوتيوب انت الي تتحكم فيها تخليها او تنحيها
مشكور اخي ..نحن بانتضار الجزء الثاني بخصوص مكيف جيون
@Asrar-1001
Ай бұрын
قصدك شرح وحدة التحكم
@user-jp1iu8nr3k
Ай бұрын
@@Asrar-1001 ايه ..مراجعة لتلكوموند ورأيك فأداء نتاعو (واذا فيه الحس....) وشكرا مرة اخرى♥️🙏
@Asrar-1001
Ай бұрын
@@user-jp1iu8nr3k الاداء تاعو والتبريد مليح مفيهش الحس وحدة التحكم راح نشرحها في قادم الايام