How to solution error code: E066-0001 E066-0002 Canon image RUNNER ADVANCE 6275

Ғылым және технология

C5535i C5540i C5550i C5560i C5230 C5235 C5240 C5245 C5230 C5035 C5040 C5045 8795 2645i 2630i 2625i 4551 4545 4535 4525 6055 6065 6075 6255 6265 6275 8085 8095 8105 8205 8505 8585 8595 6555 5555
Code: E066-0001
Description:
Pre-transfer Charging Shutter HP open error. The
Pre-transfer Charging Shutter Sensor (PS95)
detects that the shutter is opened although it is
moved to the close position.
Remedy:
1. Check the position of the Pre-transfer Charging
Shutter. 1-A. In the case that the Pre-transfer
Charging Shutter fails to operate (stopped at HP
at front side) Check the connection of the Pre-
transfer Charging Wire Cleaning Motor (M7).
Sensor side: J3108, J3089 (relay), PCB side:
J3088 (relay), J114 (Main Driver PCB (PCB2)) 1-B.
In the case that the Pre-transfer Charging Shutter
is stopped at rear side (close operation position)
1-B-1. Check that the Primary Fan Duct is closed.
Close the Primary Fan Duct. 1-B-2. Check
movement of the pin to push the Pre-transfer
Charging Shutter Sensor (P$95). Replace the Pin.
1-B-3. Check movement of the flag on the Pre
transfer Charging Shutter Sensor (PS95). Replace
the flag/ spring. 1-B-4. Check the connection of
the Pre-transfer Charging Shutter Sensor (PS95).
Sensor side: J2114, J3215 (relay), J3067 (relay)
PCB side: J3066 (relay), J130 (Main Driver PCB
(PCB2)) 1-C. In the case that the Pre-transfer
Charging Shutter is stopped along the way 1-C-1.
Check abrasion of the Slider Pin. Replace the
Slider Pin. 1-C-2. Replace the Pre-transfer
Charging Assembly. 2. Replace the DC Controller
PCB (PCB1).
★ ★ ★ ★ ★ ★
Code: E066-0002
Description:
Pre-transfer Charging Shutter HP close error. The
Pre-transfer Charging Shutter Sensor (P$95)
detects that the shutter is closed although it is
moved to the open position.
Remedy:
1. Check the position of the Pre-transfer Charging
Shutter. 1-A. In the case that the Pre-transfer
Charging Shutter fails to operate (stopped at HP
at front side) Check the connection of the Pre
transfer Charging Wire Cleaning Motor (M7).
Sensor side: J3108, J3089 (relay), PCB side:
J3088 (relay), J114 (Main Driver PCB (PCB2)) 1-B.
In the case that the Pre-transfer Charging Shutter
is stopped at rear side (close operation position)
1-B-1. Check that the Primary Fan Duct is closed.
Close the Primary Fan Duct. 1-B-2. Check
movement of the pin to push the Pre-transfer
Charging Shutter Sensor (PS95). Replace the Pin.
1-B-3. Check movement of the flag on the Pre-
transfer Charging Shutter Sensor (PS95). Replace
the flag/ spring. 1-B-4. Check the connection of
the Pre-transfer Charging Shutter Sensor (PS95)
Sensor side: J2114, J3215 (relay), J3067 (relay)
PCB side: J3066 (relay), J130 (Main Driver PCB
(PCB2)) 1-C. In the case that the Pre-transfer
Charging Shutter is stopped along the way 1-C-1
Check abrasion of the Slider Pin. Replace the
Slider Pin. 1-C-2. Replace the Pre-transfer
Charging Assembly. 2. Replace the DC Controller
PCB (PCB1).
#canon advance #Toshiba e-studio #sharp #konica minolta #develop #kyocera
#TechHumayunkabir
/ techhumayunkabir
/ humayun61

Пікірлер: 28

  • @protatolitito2014
    @protatolitito20142 жыл бұрын

    thank you for your talent, i have learn from u

  • @alwaraq7iber495
    @alwaraq7iber495 Жыл бұрын

    thanks جزاك الله خير جربت الطريقه وضبطت معي

  • @miskunjayadi8919
    @miskunjayadi89192 жыл бұрын

    Mantap

  • @TechHumayunkabir

    @TechHumayunkabir

    2 жыл бұрын

    .

  • @salman579
    @salman5793 жыл бұрын

    Video is good but Please use tripod your hand is very shaking

  • @TechHumayunkabir

    @TechHumayunkabir

    3 жыл бұрын

    Thank you for giving me the right idea

  • @rahulmourya5676
    @rahulmourya56762 жыл бұрын

    Sir if we set 5050 on 1 then it comes 0061_001 what should I do

  • @TechHumayunkabir

    @TechHumayunkabir

    2 жыл бұрын

    1) Clean the primary corona unit. 2) Exposure unit clean 3) Laser unit clean. Try this ....

  • @user-rd6ci4uv4j
    @user-rd6ci4uv4j7 ай бұрын

    sir good day, please what problem is this code Canon ImagePress C700: Error E000066-0011

  • @karencubos9778
    @karencubos9778 Жыл бұрын

    Sir my machine canon ir 6265 error 66-0001 I replace the transfer and then the machine copied 1000pcs plus error again 66-0001 ,what should I do sir

  • @TechHumayunkabir

    @TechHumayunkabir

    Жыл бұрын

    Replace transfer corona unit or corona unit Shutter open. Pre-transfer Charging Shutter HP open error The Pre-transfer Charging Shutter Sensor (PS95) detects that the shutter is opened although it is moved to the close position.

  • @mdirshad2685
    @mdirshad2685 Жыл бұрын

    Sir hamare pass canon 8505 machine hai usme error code 67 0001 araha hai kya karna padega kis chiz ka error hai ye 50 100 page chalne ke bad marta hai

  • @TechHumayunkabir

    @TechHumayunkabir

    Жыл бұрын

    kzread.info/dash/bejne/nK6V3K6Qj9TYlrA.html Yea video same as

  • @vinodwaghela951
    @vinodwaghela9513 жыл бұрын

    sir i have error e000025-001 what do i do

  • @TechHumayunkabir

    @TechHumayunkabir

    3 жыл бұрын

    Toner Feed Motor error. Overcurrent of the Toner Feed Motor (M28) was detected

  • @pogisolis3774
    @pogisolis37742 жыл бұрын

    Hello do you have some video to fix this error - E000400-0002 c3530i error

  • @TechHumayunkabir

    @TechHumayunkabir

    2 жыл бұрын

    Error code: 004-0002 Current detection circuit error Current outside the specified range flowed to the Fixing Heater when the heater was turned ON. Or, failure of fixing current detection circuit was detected. - *_Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES_* [Related parts] R1.00 - Harness between the Low Voltage Power Supply PCB (UN01/J302) and the Fixing Drawer (J1001) - Harness between the Fixing Drawer (J1001) and the Fixing Heater (H01/J1115) - Harness between the DC Controller PCB (UN049/J121) and the Fixing Drawer (J1001DB) - Harness between the DC Controller PCB (UN049/J115) and the Low Voltage Power Supply PCB (UN01/J322) - Fixing Unit - Low Voltage Power Supply PCB (UN01) - DC Controller PCB (UN049) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected.

  • @pogisolis3774

    @pogisolis3774

    2 жыл бұрын

    @@TechHumayunkabir Thank you sir! do you have any tutorial videos for these error?

  • @TechHumayunkabir

    @TechHumayunkabir

    2 жыл бұрын

    kzread.info/dash/bejne/ha162ax6mqW1iJc.html

  • @TechHumayunkabir

    @TechHumayunkabir

    2 жыл бұрын

    Same program but mechanical work this video is not the same.

  • @pogisolis3774

    @pogisolis3774

    2 жыл бұрын

    @@TechHumayunkabir thank for thee help.

  • @talarihemanth2132
    @talarihemanth2132 Жыл бұрын

    00067-001 error a

  • @TechHumayunkabir

    @TechHumayunkabir

    Жыл бұрын

    Check transfer/separation Charging corona unit Developing high voltage output leak error The leak detection signal was detected 5 times in a row for every 20 msec.

  • @user-ed2zb1xo4v

    @user-ed2zb1xo4v

    3 ай бұрын

    عندي مشكلة كود 0001-00068 رجاء ما هو سبب العطل canon 8095

  • @TechHumayunkabir

    @TechHumayunkabir

    3 ай бұрын

    kzread.info/dash/bejne/aXqGztFsf8SqZLQ.html

  • @user-ed2zb1xo4v

    @user-ed2zb1xo4v

    3 ай бұрын

    @@TechHumayunkabir شكرا كتيرا🌹🌹