Most gasman don't care . Esp the installer of mine, British Gas trained engineer. Kept telling me. Made right mess. Boiler never been right nor the thermostat n he took tiles off roof not sure if water tight but there's lot of draught n leaves coming down.
@kevk491 Жыл бұрын
Monoblock tap spanner, one of the extension fit in there . Use to always carry one just for this situation, thank me later
@derin111 Жыл бұрын
I’ve been trying to get my Ho’s for a week but they ain’t answer their phones……🤨
@bobby5634 Жыл бұрын
You'd really wanna turn that after 5-10 years wouldn't you
@muzdogbarbados5492
Жыл бұрын
you got that right mate
@ChristianBHough
Жыл бұрын
New to heating so don't bite... But if the boiler gets serviced every year, you drop the pressure to check the expansion vessel, surely it shouldn't become a problem. Assuming the boiler develops a fault twice every year that requires draining from there over a lifespan of let's say 10 years, you only need to open that 30 times. Surely it should last at least that long? I don't mind being educated and corrected.
@kendevanny4078
Жыл бұрын
@@ChristianBHough Most boilers you will go to my mate, will not have any servicing and these crappy parts always bite you on the arse.
@user.--.
Жыл бұрын
@@kendevanny4078 mine does, every year
@gow03333
Жыл бұрын
👍beat me to it
@sbe-bikes39127 ай бұрын
Or use disconnect integrated fill loop off of ch return and drain through that more control and drains quicker 👍🏼
@lifeofriley6187 Жыл бұрын
Mono block socket fits
@SloMoShort Жыл бұрын
Got an ideal logic. Works a treat.
@rayc1503 Жыл бұрын
I'm now using the drain point as one of many flue sampling points Ideal have designed throughout their boiler range 😂.
@BedsitBob Жыл бұрын
Or get a box spanner, which will have a cross hole, in case you need more leverage to undo the fitting.
@jonneym Жыл бұрын
The people on here saying 10 years out of a boiler is good. The one in my house was installed 1985 👍
@davefarmery8180
Жыл бұрын
And is not as efficient as a new one
@earlestes8649
Жыл бұрын
@@davefarmery8180 maybe but if it’s maintained properly idk,
@janice6173
Жыл бұрын
They were made to last. The ones after were pile of crud. In my experience.
@Danfrank24
7 ай бұрын
@@davefarmery8180you keep on lapping up lies. They may be less efficient as in the don’t burn as much of the gas they are given but a 14kw heat only boiler uses a lot less gas that a new combi. Especially when you’ve got idiots installing 38kw in 2 bed semis so they get “good” hot water.
@doncodman913 Жыл бұрын
Hi ya.. looks like that blackdrain spout has a slot on the end for an oversize flatblade screwdriver...?
@muzdogbarbados5492 Жыл бұрын
still leaking
@willcpfc4720 Жыл бұрын
Basin spanner set does the trick
@pigswillbepigs Жыл бұрын
Been wondering what they are, They are my grips. 😂
@Vass881234 Жыл бұрын
What do you turn off first tho?
@MrPaulogenes Жыл бұрын
Very helpful. Thank you
@AllenHart999
8 ай бұрын
Thanks very much for your comment, please consider subscribing to support the channel 🙂
@kurashare40785 ай бұрын
Thanks
@AllenHart999
5 ай бұрын
Thanks very much for your comment, please consider subscribing to support the channel 🙂
@NibblestheHamster7 ай бұрын
If return valve is closed and cold water inlet closed, undo the cold side of the integrated filling loop, put a small piece of drain down hose (the larger one) and then open the return, much easier to drain than clarting on trying to open that drain off, easy when there’s space but if your limited for space just crack the filling loop
@UAVWRIGHT
6 ай бұрын
Do those valves need to be closed or can I just unscrew and ain
@magdalenenjoki9679
6 ай бұрын
K4iokekynaphh name gb❤❤❤❤❤❤
@randomcamerajunk6977 Жыл бұрын
Imagine designing an appliance that you fill with water and then fit it with a barely functional drain point. Designed by muppets and installed by muppets
@ollieneate7928
Жыл бұрын
😆 well said
@joboeyful5 ай бұрын
Swear that went everywhere but….😂
@AllenHart999
5 ай бұрын
ha ha, it did.
@janice6173 Жыл бұрын
Nice clear n good rate too. Most info on these is like flipping Road runner or is USA I won't be attempting it but good to know.
@connerhuetson3581 Жыл бұрын
Just drain it down through the filling loop😜
@kendevanny4078
Жыл бұрын
Most people put the FL back to front, with the check valve on the return and fcuks this meth up.
@petermckiernan5822
Жыл бұрын
Not with a double check valve on the loop you won't.
@HughieMunro
Жыл бұрын
@@petermckiernan5822 double check goes on the cold water side 🤦♂️ You have no idea how many people still put them the wrong way round…. I’m guessing your one of them 😜😜😜 So yes, you can drain through filling loop if fitted CORRECTLY
@petermckiernan5822
Жыл бұрын
@@HughieMunro not so mate, I fit two, one on the cold main and one on the heating return, stops twats disconnecting the loop and accidentally draining 60° water into their face.
@sbe-bikes3912
7 ай бұрын
Every time even on the integral loops can drain down 👍🏼
@tk48358 ай бұрын
Omg that’s fascinating 🥸
@aronhaxhilari17435 ай бұрын
Open the filling loop point it into the bucket or sink and done
@mcbreartyfull5 ай бұрын
Pissing out over floor lad 😂
@mcbreartyfull
5 ай бұрын
Happens the best of us 🙏
@martinlouden9005 Жыл бұрын
That's a good tip. I'm not sure why there are so many negative comments?
@Brian777667 ай бұрын
What size is the nut on the plastic drain off?
@jezlucas3878 Жыл бұрын
Quite like the logic
@UAVWRIGHT6 ай бұрын
Is there anything else you need to do once drained?
@James-pz6jc7 ай бұрын
Any idea what will fix a L1 code thanks
@a5amr2 Жыл бұрын
When did Phil Mitchell become a plumber
@alexstoles1339 Жыл бұрын
Would a long socket fit over it to loosen it?
@romeomeoful Жыл бұрын
I need to get my course done
@nathd17488 ай бұрын
Why is your video back to front Allen? I noticed the filling loop on left and wondered WTF?
@martincole846224 күн бұрын
Why is there compression on the pressure relief pipe. And this is a loaded question
@richardshort4587 Жыл бұрын
Designed to fail = more money to be made on servicing or replacement. Once you get mineral deposits on that drain all bets are off. More so because it’s plastic.
@mikeznel6048 Жыл бұрын
Could turn it with a socket too. I like outside of the box ideas though myself.
@brians8664
Жыл бұрын
plumbers don’t carry sockets or box end wrenches. Why? No company makes ones that are special enough to cost 50x what they should cost 😂
@firsteerr Жыл бұрын
box spanner set ?
@maxmerton Жыл бұрын
Am I missing something? Why not a box spanner?
@kevinw74196 ай бұрын
Ideal, to change it to a better boiler!!
@777mjt Жыл бұрын
Standard garden hose fits over the hex part and grips it enough to turn open, I know I've worked on hundreds of Logics 😎
@Chronologist89
Жыл бұрын
Yeah, that looks like a self-blocking gardena adapter, was thinking the same.
@jimbevan4107
Жыл бұрын
Are they good boilers?
@nickbea3443 Жыл бұрын
Crap access then leaks everywhere. How about input at design stage from heating engineers?
@mb106429 Жыл бұрын
I need a piss now
@dunckeroo19876 ай бұрын
Looks like that tap could use some sealing tape.
@sambutler927 Жыл бұрын
Yeah they are shite, I fit loads of Ideal Logics but those drain offs piss out.
@andyparky2716
Жыл бұрын
I like ideal for the money put one in my own house actually
@mellepasveer6173 Жыл бұрын
And why then you have to refill the boiler again
@mike004692 Жыл бұрын
ideal would be great to design a tool for it , it could get lost along with the handles for those mag filters
@kendevanny4078
Жыл бұрын
And the fill keys for Worcesters
@richardwakelin8438 ай бұрын
A box spanner is built for the job
@AllenHart999
8 ай бұрын
Thank You
@Skydiver1000 Жыл бұрын
It’s a pity that Ideal, and many other manufacturers fail to provide a good design tap for draining the boiler. Or in a location that is easy to get to. If they want to make sure that it’s not mistaken for anything else by the end user then keep the actual tap inside the boiler. I use 1/4 drive long sockets for the small nuts and bolts, but the chamfer lead on them stops any engagement onto this hexagon. If it needs a special tool then it should be given away with the product.
@earlestes8649
Жыл бұрын
Yeah like the drain and flush kit that includes the pop off valve. I don’t know how many I’ve went and installed them a year or two after they were originally installed. It’s nuts!!
@TheLeekibble8 ай бұрын
Is this to drain down the central heating so I can reroute some pipes and add a rad? Thanks
@AllenHart999
8 ай бұрын
Thank You
@pauls826 Жыл бұрын
Love ideals to service soooo easy but thst drain off is a bastard
@pipedgolf4634 Жыл бұрын
Danm when they said gas workers can go to a job in a white shirt and leave clean I thought they were joking
@johnwelsh10776 ай бұрын
Personally I just use a big flat head screwdriver or chisel and put it in the slot that’s there instead of the messing about with copper 😂
@projectgaming3364 Жыл бұрын
Could you not just attach the hose to the other end of the copper pipe and then you only ever need to turn it easily
@2smokerjoker1785 ай бұрын
Nice and easy as it piss's all over his arm 😂
@alanwoods4023 Жыл бұрын
It’s pissing out round the hose Allen. Not a great drain off
@luckyman8319 Жыл бұрын
Get you hooes
@mellepasveer6173 Жыл бұрын
That has to be connected always ,that's the pressure overflow
@TprDjd21
Жыл бұрын
No it isn’t
@insidegamesluan8934 Жыл бұрын
Anybody saw that theres a slot for a flat head screwdriver
@freightshayker8 ай бұрын
Noyce
@ram64man Жыл бұрын
why not just add a bit of reducing pipe to a bit of plex to attach the drain pipe all in one, that way you can keep it all in the kit bag
@alexriley66635 ай бұрын
Or ye get ye mono spanner 😂
@burrowlad Жыл бұрын
Great boilers to work on but by far the worst drain off awkward positioning and no matter what you do it always leaks over the hose 🖕🏻
@ricklee827 Жыл бұрын
Love the copper not a big fan of the pro press
@abdoolbeebeejaun8408 Жыл бұрын
Hey Allen what is the best pressfit to buy? And where you get the best deal
@s.wilson5675
Жыл бұрын
Hello mate, (I'm not Allen).... I used the Conex brand (copper, not plastic) from Toolstation and been on my CH system 2 years with no problems. Toolstation also sell Pegler, a good brand apparently. The MOST important part of using push fit is pipe preparation. Spend extra time to cut pipe square, deburr, clean in and out. Good luck.
@FriendlyFireBrigade
Жыл бұрын
@@s.wilson5675he asked for PRESS fit, not push fit.
@s.wilson5675
Жыл бұрын
@@FriendlyFireBrigade Oops. My bad. Thanks for correcting.
@frianklippelaar73315 ай бұрын
I suppose a pipe wrench is also an option
@frianklippelaar7331
5 ай бұрын
My bad. In dutch its called a pipe wrench. An english pipe wrench is something else. Box spanner is the correct translation😂🤦♂️
@fivish Жыл бұрын
This 'plumber' has lots of videos which make you wonder if he is a prankster. Water is running down the ouside of his hose!
@theodore881 Жыл бұрын
All boilers have drain and turn by tap don't know why this is like this
@goodhouse910215 ай бұрын
Oh no not mapress right by the boiler connections 😅😅😅
@theodore881 Жыл бұрын
Use orange pipe
@Bertie2118 ай бұрын
Just use a flat head
@AllenHart999
8 ай бұрын
Thank You
@nico101gaming Жыл бұрын
Or just drain it through the filling loop 😅
@sambowden1062 Жыл бұрын
I've got a tip for you... But some nail clippers
@AllenHart999
Жыл бұрын
I have a tip, if you are going to be rude at least spell it correctly 😂
@sleektoneofficial Жыл бұрын
Never seen no pro press fittings like that
@experienceb4bob11 ай бұрын
The problem allan is the water which came out of your pipe outer diameter
@AllenHart999
8 ай бұрын
Thank You
@k20aa Жыл бұрын
There was nothing easy about that 😂😂 Bad design plastic junk
@fredthesavannahcat2899
Жыл бұрын
It is a bad design
@dezbeatty4250 Жыл бұрын
Or buy a deep socket for you're toolkit
@GaryHynes-im5di5 ай бұрын
Just use the prv...
@mx-lj4qq Жыл бұрын
Get your tools and get out of my house 😂😂 just kidding
@scottborton7774 Жыл бұрын
Yea good idea water going everywhere lol
@meatballhead3290 Жыл бұрын
I'll stick to using PRV 🤣😂
@justinowen8361 Жыл бұрын
Take it you don’t have a set of tap spanners
@oharv15 ай бұрын
Don’t work on ideal usually chuck em on the grass
@gobrad10 ай бұрын
Is it true these combi boilers are only good for a 1 to 2 bedroom house?
@AllenHart999
8 ай бұрын
did you watch this one? interested to hear your thoughts? Thanks. kzread.info/dash/bejne/rHV-stGveNvaiNY.html
@jamo78s3 Жыл бұрын
An get charged a squillian pound for doing it
@dr-mn7ld Жыл бұрын
that rule forcing the flexible hose is so dumb
@Stuart_Johnson_Solutions Жыл бұрын
And it's such a poor design the water runs down the outside of the hose and all over the floor...
@iainrichardson44955 ай бұрын
Yea and pissing out down the outside of his pipe.....
@Lutonman2010 Жыл бұрын
That drain off is one of the worst bits about the logic. Along with the stupid bracket that holds the vessel in that’s a pig to line up. I was really surprised to see that terrible drain off design has been carried over to the new logic. Do any of these manufacturers ever actually speak to service and repair guys? Ok they’ve at least sorted out the poor condensate trap this time around. But leaving that drain off? Really?
@kendevanny4078 Жыл бұрын
Forget that drain-off it will ruin your Friday. Just dump out the PRV and be done with it.
@TWH442
Жыл бұрын
yes and then the prv leaks because it wont seal again. cowboy.
@kendevanny4078
Жыл бұрын
@@TWH442 Oh forgot no one tests the fuction of the prv anymore during a service. Not as if they can be cleaned either. Im such a numpty.
@kevinohara19085 ай бұрын
Bad design
@AllenHart999
5 ай бұрын
Thank You
@jazsingh4186 Жыл бұрын
Flat head screwdriver
@arthurdaley895 Жыл бұрын
It's pissing out the top and down the sides of the fitting spilling everywhere. What a piece of crap factory fitting.
@giffy8924 Жыл бұрын
As phill Mitchell got a new job?
@danieldaniel43 Жыл бұрын
Looks like a lazy boiler install there. Not one soldered joint
@petersabatini7817 Жыл бұрын
Why don’t you just use a socket with and extension
Пікірлер: 152
And drain it off all over the floor 😂
@stevehirst536
Жыл бұрын
Was going to say exactly the same 😂
@janice6173
Жыл бұрын
Most gasman don't care . Esp the installer of mine, British Gas trained engineer. Kept telling me. Made right mess. Boiler never been right nor the thermostat n he took tiles off roof not sure if water tight but there's lot of draught n leaves coming down.
Monoblock tap spanner, one of the extension fit in there . Use to always carry one just for this situation, thank me later
I’ve been trying to get my Ho’s for a week but they ain’t answer their phones……🤨
You'd really wanna turn that after 5-10 years wouldn't you
@muzdogbarbados5492
Жыл бұрын
you got that right mate
@ChristianBHough
Жыл бұрын
New to heating so don't bite... But if the boiler gets serviced every year, you drop the pressure to check the expansion vessel, surely it shouldn't become a problem. Assuming the boiler develops a fault twice every year that requires draining from there over a lifespan of let's say 10 years, you only need to open that 30 times. Surely it should last at least that long? I don't mind being educated and corrected.
@kendevanny4078
Жыл бұрын
@@ChristianBHough Most boilers you will go to my mate, will not have any servicing and these crappy parts always bite you on the arse.
@user.--.
Жыл бұрын
@@kendevanny4078 mine does, every year
@gow03333
Жыл бұрын
👍beat me to it
Or use disconnect integrated fill loop off of ch return and drain through that more control and drains quicker 👍🏼
Mono block socket fits
Got an ideal logic. Works a treat.
I'm now using the drain point as one of many flue sampling points Ideal have designed throughout their boiler range 😂.
Or get a box spanner, which will have a cross hole, in case you need more leverage to undo the fitting.
The people on here saying 10 years out of a boiler is good. The one in my house was installed 1985 👍
@davefarmery8180
Жыл бұрын
And is not as efficient as a new one
@earlestes8649
Жыл бұрын
@@davefarmery8180 maybe but if it’s maintained properly idk,
@janice6173
Жыл бұрын
They were made to last. The ones after were pile of crud. In my experience.
@Danfrank24
7 ай бұрын
@@davefarmery8180you keep on lapping up lies. They may be less efficient as in the don’t burn as much of the gas they are given but a 14kw heat only boiler uses a lot less gas that a new combi. Especially when you’ve got idiots installing 38kw in 2 bed semis so they get “good” hot water.
Hi ya.. looks like that blackdrain spout has a slot on the end for an oversize flatblade screwdriver...?
still leaking
Basin spanner set does the trick
Been wondering what they are, They are my grips. 😂
What do you turn off first tho?
Very helpful. Thank you
@AllenHart999
8 ай бұрын
Thanks very much for your comment, please consider subscribing to support the channel 🙂
Thanks
@AllenHart999
5 ай бұрын
Thanks very much for your comment, please consider subscribing to support the channel 🙂
If return valve is closed and cold water inlet closed, undo the cold side of the integrated filling loop, put a small piece of drain down hose (the larger one) and then open the return, much easier to drain than clarting on trying to open that drain off, easy when there’s space but if your limited for space just crack the filling loop
@UAVWRIGHT
6 ай бұрын
Do those valves need to be closed or can I just unscrew and ain
@magdalenenjoki9679
6 ай бұрын
K4iokekynaphh name gb❤❤❤❤❤❤
Imagine designing an appliance that you fill with water and then fit it with a barely functional drain point. Designed by muppets and installed by muppets
@ollieneate7928
Жыл бұрын
😆 well said
Swear that went everywhere but….😂
@AllenHart999
5 ай бұрын
ha ha, it did.
Nice clear n good rate too. Most info on these is like flipping Road runner or is USA I won't be attempting it but good to know.
Just drain it down through the filling loop😜
@kendevanny4078
Жыл бұрын
Most people put the FL back to front, with the check valve on the return and fcuks this meth up.
@petermckiernan5822
Жыл бұрын
Not with a double check valve on the loop you won't.
@HughieMunro
Жыл бұрын
@@petermckiernan5822 double check goes on the cold water side 🤦♂️ You have no idea how many people still put them the wrong way round…. I’m guessing your one of them 😜😜😜 So yes, you can drain through filling loop if fitted CORRECTLY
@petermckiernan5822
Жыл бұрын
@@HughieMunro not so mate, I fit two, one on the cold main and one on the heating return, stops twats disconnecting the loop and accidentally draining 60° water into their face.
@sbe-bikes3912
7 ай бұрын
Every time even on the integral loops can drain down 👍🏼
Omg that’s fascinating 🥸
Open the filling loop point it into the bucket or sink and done
Pissing out over floor lad 😂
@mcbreartyfull
5 ай бұрын
Happens the best of us 🙏
That's a good tip. I'm not sure why there are so many negative comments?
What size is the nut on the plastic drain off?
Quite like the logic
Is there anything else you need to do once drained?
Any idea what will fix a L1 code thanks
When did Phil Mitchell become a plumber
Would a long socket fit over it to loosen it?
I need to get my course done
Why is your video back to front Allen? I noticed the filling loop on left and wondered WTF?
Why is there compression on the pressure relief pipe. And this is a loaded question
Designed to fail = more money to be made on servicing or replacement. Once you get mineral deposits on that drain all bets are off. More so because it’s plastic.
Could turn it with a socket too. I like outside of the box ideas though myself.
@brians8664
Жыл бұрын
plumbers don’t carry sockets or box end wrenches. Why? No company makes ones that are special enough to cost 50x what they should cost 😂
box spanner set ?
Am I missing something? Why not a box spanner?
Ideal, to change it to a better boiler!!
Standard garden hose fits over the hex part and grips it enough to turn open, I know I've worked on hundreds of Logics 😎
@Chronologist89
Жыл бұрын
Yeah, that looks like a self-blocking gardena adapter, was thinking the same.
@jimbevan4107
Жыл бұрын
Are they good boilers?
Crap access then leaks everywhere. How about input at design stage from heating engineers?
I need a piss now
Looks like that tap could use some sealing tape.
Yeah they are shite, I fit loads of Ideal Logics but those drain offs piss out.
@andyparky2716
Жыл бұрын
I like ideal for the money put one in my own house actually
And why then you have to refill the boiler again
ideal would be great to design a tool for it , it could get lost along with the handles for those mag filters
@kendevanny4078
Жыл бұрын
And the fill keys for Worcesters
A box spanner is built for the job
@AllenHart999
8 ай бұрын
Thank You
It’s a pity that Ideal, and many other manufacturers fail to provide a good design tap for draining the boiler. Or in a location that is easy to get to. If they want to make sure that it’s not mistaken for anything else by the end user then keep the actual tap inside the boiler. I use 1/4 drive long sockets for the small nuts and bolts, but the chamfer lead on them stops any engagement onto this hexagon. If it needs a special tool then it should be given away with the product.
@earlestes8649
Жыл бұрын
Yeah like the drain and flush kit that includes the pop off valve. I don’t know how many I’ve went and installed them a year or two after they were originally installed. It’s nuts!!
Is this to drain down the central heating so I can reroute some pipes and add a rad? Thanks
@AllenHart999
8 ай бұрын
Thank You
Love ideals to service soooo easy but thst drain off is a bastard
Danm when they said gas workers can go to a job in a white shirt and leave clean I thought they were joking
Personally I just use a big flat head screwdriver or chisel and put it in the slot that’s there instead of the messing about with copper 😂
Could you not just attach the hose to the other end of the copper pipe and then you only ever need to turn it easily
Nice and easy as it piss's all over his arm 😂
It’s pissing out round the hose Allen. Not a great drain off
Get you hooes
That has to be connected always ,that's the pressure overflow
@TprDjd21
Жыл бұрын
No it isn’t
Anybody saw that theres a slot for a flat head screwdriver
Noyce
why not just add a bit of reducing pipe to a bit of plex to attach the drain pipe all in one, that way you can keep it all in the kit bag
Or ye get ye mono spanner 😂
Great boilers to work on but by far the worst drain off awkward positioning and no matter what you do it always leaks over the hose 🖕🏻
Love the copper not a big fan of the pro press
Hey Allen what is the best pressfit to buy? And where you get the best deal
@s.wilson5675
Жыл бұрын
Hello mate, (I'm not Allen).... I used the Conex brand (copper, not plastic) from Toolstation and been on my CH system 2 years with no problems. Toolstation also sell Pegler, a good brand apparently. The MOST important part of using push fit is pipe preparation. Spend extra time to cut pipe square, deburr, clean in and out. Good luck.
@FriendlyFireBrigade
Жыл бұрын
@@s.wilson5675he asked for PRESS fit, not push fit.
@s.wilson5675
Жыл бұрын
@@FriendlyFireBrigade Oops. My bad. Thanks for correcting.
I suppose a pipe wrench is also an option
@frianklippelaar7331
5 ай бұрын
My bad. In dutch its called a pipe wrench. An english pipe wrench is something else. Box spanner is the correct translation😂🤦♂️
This 'plumber' has lots of videos which make you wonder if he is a prankster. Water is running down the ouside of his hose!
All boilers have drain and turn by tap don't know why this is like this
Oh no not mapress right by the boiler connections 😅😅😅
Use orange pipe
Just use a flat head
@AllenHart999
8 ай бұрын
Thank You
Or just drain it through the filling loop 😅
I've got a tip for you... But some nail clippers
@AllenHart999
Жыл бұрын
I have a tip, if you are going to be rude at least spell it correctly 😂
Never seen no pro press fittings like that
The problem allan is the water which came out of your pipe outer diameter
@AllenHart999
8 ай бұрын
Thank You
There was nothing easy about that 😂😂 Bad design plastic junk
@fredthesavannahcat2899
Жыл бұрын
It is a bad design
Or buy a deep socket for you're toolkit
Just use the prv...
Get your tools and get out of my house 😂😂 just kidding
Yea good idea water going everywhere lol
I'll stick to using PRV 🤣😂
Take it you don’t have a set of tap spanners
Don’t work on ideal usually chuck em on the grass
Is it true these combi boilers are only good for a 1 to 2 bedroom house?
@AllenHart999
8 ай бұрын
did you watch this one? interested to hear your thoughts? Thanks. kzread.info/dash/bejne/rHV-stGveNvaiNY.html
An get charged a squillian pound for doing it
that rule forcing the flexible hose is so dumb
And it's such a poor design the water runs down the outside of the hose and all over the floor...
Yea and pissing out down the outside of his pipe.....
That drain off is one of the worst bits about the logic. Along with the stupid bracket that holds the vessel in that’s a pig to line up. I was really surprised to see that terrible drain off design has been carried over to the new logic. Do any of these manufacturers ever actually speak to service and repair guys? Ok they’ve at least sorted out the poor condensate trap this time around. But leaving that drain off? Really?
Forget that drain-off it will ruin your Friday. Just dump out the PRV and be done with it.
@TWH442
Жыл бұрын
yes and then the prv leaks because it wont seal again. cowboy.
@kendevanny4078
Жыл бұрын
@@TWH442 Oh forgot no one tests the fuction of the prv anymore during a service. Not as if they can be cleaned either. Im such a numpty.
Bad design
@AllenHart999
5 ай бұрын
Thank You
Flat head screwdriver
It's pissing out the top and down the sides of the fitting spilling everywhere. What a piece of crap factory fitting.
As phill Mitchell got a new job?
Looks like a lazy boiler install there. Not one soldered joint
Why don’t you just use a socket with and extension
Yeah, a fucking mess!