How To Connect Refrigerant Lines Without BRAZING!! | RLS Press Tool

Фильм және анимация

- SUPPORT THE CHANNEL -
www.patreon.com/qualityhvacr?...
- Check out @TruTech Tools, LTD -
www.trutechtools.com (Use promo code “QUALITYHVAC” to save 8%)
- HVAC TACTICAL -
hvactactical.com/ (Use Promo Code "QUALITYHVAC" to save 10%!)
- FOLLOW ME -
Instagram: @qualityhvacr
- BUSINESS INQUIRES -
qualityhvacrtn@gmail.com
- TOOLS I USE -
RLS Klauke Braze-Free 5 Jaw Kit
www.trutechtools.com/klauke-1...
Fieldpiece SC440 Meter: www.trutechtools.com/SC440?af...
Fieldpiece SM380V Digital Manifold: www.trutechtools.com/Fieldpie...
Veto ProPac Tech MCT Tool Bag: www.trutechtools.com/TECHMCT?...
Supco Magnetic Umbrella: www.trutechtools.com/Supco-Ma...
Solderweld HVAC Brazing Pack: www.trutechtools.com/HVAC-15-...
Solderweld Hot Block Putty: www.trutechtools.com/SolderWe...
Navac 2cfm Battery Operated Vacuum Pump: www.trutechtools.com/NAVAC-NP...
Cordless-Vacuum-Pump-2CFM?affid=38
Accutools BluVac Micron Gauge: www.trutechtools.com/Accutool...
Accutools TruBlu Evacuation Kit: www.trutechtools.com/Accutool...
Veto ProPac LC Tool Bag: www.trutechtools.com/Veto-Tec...
Veto ProPac MC Tool Bag: www.trutechtools.com/Veto-Pro...
MeasureQuick App: www.measurequick.com/
Fieldpiece Job Link HVACR Charge & Air Kit: www.trutechtools.com/JL3KH6?a...
Fieldpiece Job Link Pressure Probe: www.trutechtools.com/Fieldpie...
Appion 1/2" Hose: www.trutechtools.com/MH120006...
Appion 3/8" Hose: www.trutechtools.com/Appion-M...
AccuTools Core Removal Tool: www.trutechtools.com/Accutool...
Malco Sheet Metal Snips (Left Cut): www.trutechtools.com/Malco-M2...
Malco Sheet Metal Snips (Right Cut): www.trutechtools.com/Malco-M2...
Malco Sheet Metal Snips (Bulldogs): www.trutechtools.com/Malco-M2...
Malco Sheet Metal Snips: www.trutechtools.com/Malco-MC...
Malco Turbo Shear Cutter: www.trutechtools.com/Malco-TS...
Malco Sheet Metal Hole Cutter: www.trutechtools.com/Malco-HC...
Malco Flex Duct Cutter: www.trutechtools.com/Malco-FD...
Malco Panduit Gun: www.trutechtools.com/Malco-TY...
Malco Sheet Metal Hammer: www.trutechtools.com/Malco-RH...
Malco Turbo Crimper: www.trutechtools.com/Malco-C5...
Malco Sheet Metal Pipe Crimper: www.trutechtools.com/Malco-C5...
Malco Reversible Hex Driver: www.trutechtools.com/Malco-MS...
Malco 24" hand bender: www.trutechtools.com/Malco-24...
I needed to relocate a condenser to the other side of the house, so I thought this was a perfect opportunity to test out the RLS press tool and fittings. To say the least, I was blown away with how easy, quick, and reliable this setup is when connecting refrigerant lines. Hope you enjoy!
#hvac #presstool #refrigeration

Пікірлер: 946

  • @dutch661
    @dutch6613 жыл бұрын

    Went from a really good channel to another trutechtools salesman.

  • @Deltron6060

    @Deltron6060

    3 жыл бұрын

    Yup, moving on.

  • @domrod1579

    @domrod1579

    3 жыл бұрын

    I was thinking the same thing

  • @zaclamb9038

    @zaclamb9038

    3 жыл бұрын

    Money talks. Can’t blame him. Means he’s doing something right. 👍🏻

  • @cesarmoore7996

    @cesarmoore7996

    3 жыл бұрын

    I am sure if you had a channel get as big as his you would do the same, any one of us would love to get these tools for free or even at a discount and then get paid to show case them. So go ahead and move on... I will continue to enjoy his videos and support his channel.

  • @dutch661

    @dutch661

    3 жыл бұрын

    Imagine going to watch a show you like and it's a 30min commercial.

  • @nightcoder5k
    @nightcoder5k2 жыл бұрын

    Good to see a professional who is proud of his work. Amazing work. Thanks for sharing the video.

  • @brandonrodriguez9403
    @brandonrodriguez94033 жыл бұрын

    Been doing hvac for roughly 7 months, falling in love with the trade more and more everyday! Your videos have MOST definitely helped give me a better understanding of what’s going on.

  • @wendtheatandair

    @wendtheatandair

    3 жыл бұрын

    then you need to not watch one of these bs videos. this is not whats going on. best advice is to work with someone who has been in the trade for 20 years or more, they will show you the correct way.

  • @brandonrodriguez9403

    @brandonrodriguez9403

    3 жыл бұрын

    @@wendtheatandair oh for sure man I understand what you mean, I still much rather prefer brazing then using those press fittings but overall the guy does some solid work, so that’s what’s helped me raise my own bar at work as well. If that makes sense.

  • @antmothirteen6540

    @antmothirteen6540

    2 жыл бұрын

    This isn't how things actually roll ..

  • @P9rkour90

    @P9rkour90

    2 жыл бұрын

    I just finished school and started working and I am too loving this trade! A lot good hvac tech KZread channels

  • @cbaykal001
    @cbaykal0013 жыл бұрын

    clean install, detail oriented business owner , taking pride in his work. Applies the best practices with a disciplined approach. Thumbs up!

  • @ryanjones7921
    @ryanjones79213 жыл бұрын

    I’ve never seen a Hvac technician so passionate about reaming and deburring pipe,, he must love his job

  • @rodgraff1782

    @rodgraff1782

    Жыл бұрын

    Reaming is very important. Leaving those burrs at every joint ads up to quite a pressure loss. I once was at a commercial job where an inspector saw a tech not reaming his pipe. He made him cut the whole system apart, and do it over. It is in most job specs, just like purging while brazing. Not doing so is just plane laziness, and no pride in workmanship.

  • @yoshisatoshi3206

    @yoshisatoshi3206

    3 ай бұрын

    Just a little something called, "having integrity".

  • @clayfree7428
    @clayfree74283 жыл бұрын

    34 years in the Commercial HVAC business....Too expensive and still subject to leaks. A well prepped fitting and pipe will out last any of these press systems. Good video!

  • @Flap999

    @Flap999

    3 жыл бұрын

    This system just reminds me a little too much of the Ford automotive spring lock connections. They’re real great when they’re new for a couple years of vibration and heat and they leak like grandma’s spaghetti strainer. I’m all for new ideas if they work. But I know when I’ve welded a joint it’s not coming apart.

  • @srobeck77

    @srobeck77

    2 жыл бұрын

    It like the switch from cash in the mattress to putting it into banks. All the old timers resist change until the day they die, no matter what.

  • @JayBirde

    @JayBirde

    2 жыл бұрын

    @@srobeck77 Trust me, I was skeptical at first to, but also open to new ideas. I have been in the trade 26 years and have seen some pretty crazy ideas in HVAC (ammonia anyone?). I did my entire LG VRF lab with RLS fittings in 2019 and haven't had ONE issue. Keep in mind too that with LG VRF, the metering device is in the indoor unit, so we are running alot higher pressures than a residential mini-split sytem. And the fittings are warrantied for 10 years.

  • @decoysk

    @decoysk

    2 жыл бұрын

    @@srobeck77 because they work best

  • @grigorshukerski4689

    @grigorshukerski4689

    Жыл бұрын

    @@srobeck77 Cash in the mattress is still better than in the bank

  • @dannystiasny3891
    @dannystiasny38913 жыл бұрын

    GREAT VIDEO !! Plumber ,trying to learn more AC , thanks for explaining some of the things your doing and the numbers your looking for along the way , it helped me get a general idea of the process and and readings of a ac system basics , (with not so much info I get lost ). understanding different equipment sizing and developed length of your piping with change numbers and reading your probably looking for ... Thanks

  • @robinjackson7540
    @robinjackson75402 жыл бұрын

    You make a day in the life of an HVAC engineer look EASY. Props to you bro on your skills & knowledge.

  • @grigorshukerski4689

    @grigorshukerski4689

    Жыл бұрын

    This is not a day life of an engineer rather HVAC technician

  • @dog_city
    @dog_city2 жыл бұрын

    I used zoomlock a 3 years ago and it leaked 2 years later at all the joints. We had the little symbol showing meaning we did it right. Hopefully the tech has gotten better. Unfortunatly though to use a press on fitting you have to braze connection points onto the coil and condensor as well as braze in your filter dryer unless they fixed those problems

  • @SonsofIssac
    @SonsofIssac3 жыл бұрын

    As much as I love the whole process of brazing, I gotta say that looks simple and efficient.

  • @sportsngamingdmv6673

    @sportsngamingdmv6673

    3 жыл бұрын

    No point if you have to braze the coil and the condenser if im running line sets sometimes i dont use couplings with a tubing bender until the coils and the condenser comes pro press ready this is just extra work

  • @lordjaashin

    @lordjaashin

    3 жыл бұрын

    @@sportsngamingdmv6673 not to mention the tool kit costs couple of grands. lol

  • @Jake-by9ly

    @Jake-by9ly

    2 жыл бұрын

    And a whole lot faster! Be sure to charge flat rate, not HOURLY

  • @49ertruther53

    @49ertruther53

    2 жыл бұрын

    Time is money. If this tool can help you get the job done and in a timely manner why not invest? I've been in the industrial field for over 15 years. The 1 common saying I heard growing in the field was "work smarter, not harder". I believe this is working smarter. Would love to try this thing out. Definitely investing into this

  • @5thhorseman982

    @5thhorseman982

    2 жыл бұрын

    @@Jake-by9ly Theres a reason why people still weld in 2022....Not because they like to or its fun. If you had a drill that can put in screws 17x faster then you will just be expected to screw in 17 times as many screws. Tech only helps our lives to a certain point.

  • @redmanstunts2662
    @redmanstunts26623 жыл бұрын

    Love you’re channel !watch it on my lunch breaks an learn new stuff every time keep it up definitely need to get me a set of theses!!!!

  • @williamforrester9652
    @williamforrester96523 жыл бұрын

    Love your hat and I love learning from you. I’m an apprentice doing hvac installs

  • @pmichaelhayes
    @pmichaelhayes2 жыл бұрын

    Problem with that tool is the fittings are $15-25 per, and you still had to break out the torch to braze that stub on the heat pump and the air handler. So you still had to drag out your torch and nitrogen. In the attic that was a great application for the tool. If you just use a tubing bender you could have just brazed the pipe to the A/C and you would have no joints other then the connections to the heat pump to ever leak. This is why I decided to not buy this tool, as I knew I would be dragging out all my other gear anyway. Not trying to bad mouth your work, you did a very nice job. That customer is lucky they did not get some hack to install their system. Very nice work and attention to detail.

  • @actechchris
    @actechchris3 жыл бұрын

    How about a follow up video in 6-12months to see how they hold?

  • @man4evil

    @man4evil

    3 жыл бұрын

    it holds. this is like viega press water/gas fittings, but at cheaper costs.

  • @buckeyenation89

    @buckeyenation89

    3 жыл бұрын

    Holds very good. I have pressure tested at 600 psi with them and no issues. Quick and convenient. Cuts the material and time down dramatically.

  • @hvacslayer2929

    @hvacslayer2929

    3 жыл бұрын

    I’d say a couple years. Wonder how the gaskets would do in a system that’s acidic.

  • @actechchris

    @actechchris

    3 жыл бұрын

    @@buckeyenation89 nice! I think it might be time for me to just bite the bullet and try them myself!

  • @TaRgEt0ZeRo

    @TaRgEt0ZeRo

    3 жыл бұрын

    @@hvacslayer2929 410 oil is acid

  • @wirenut003
    @wirenut0033 жыл бұрын

    Zack your the man, looks like you take pride in your work. Today that is hard to come by.

  • @martinheatingcoolingmartin4693
    @martinheatingcoolingmartin46933 ай бұрын

    Thanks for this demo, I really look forward to using this setup this season!

  • @hectormercado8065
    @hectormercado80653 жыл бұрын

    I checked the price on these things and I’ve decided to stick with my oxy-acet. Honestly I would not be able to sleep that night if I used those fittings. I’d be like damn did I crimp it good? Did I mess up the oring? Nope can’t do it lol. If it was cheaper I’ll be all over it I ain’t going to lie for hard to braze places.

  • @DiegoPerez-ro9si

    @DiegoPerez-ro9si

    3 жыл бұрын

    I agree with you 1000%

  • @danny_hampton

    @danny_hampton

    2 жыл бұрын

    You use a crimping system and you’ll never braze again. Such an out dated concept.

  • @DiegoPerez-ro9si

    @DiegoPerez-ro9si

    2 жыл бұрын

    @@danny_hampton maybe so. I wish you could try shit out before paying for it though 😂

  • @dustinpomeroy8817

    @dustinpomeroy8817

    2 жыл бұрын

    @@DiegoPerez-ro9si you can rent em,ask your supply house about it

  • @markcavelli9087

    @markcavelli9087

    2 жыл бұрын

    @@danny_hampton still have to braze to the condenser and at air handler

  • @dyershvac5884
    @dyershvac58842 жыл бұрын

    Awesome video bro! You could be an Hvac instructor. You are very clear, and straight to the point on all your work and demonstrations. You are 1 of my favorite guys online!!

  • @561lyfestyle2

    @561lyfestyle2

    Жыл бұрын

    Bruh no no, he said he's going from 5/8 copper to 3/8" and then marks pipe twice instead of doing it just once buddy's messing up all over the place plus it must be nice that daddy had his own hbac company not like he didn't help you at all...smh

  • @deebahamarockmeadows1506
    @deebahamarockmeadows15063 жыл бұрын

    Pretty cool I’ve been installing for over 20 years and never use them going to have to give them a shot

  • @diyhvacguy
    @diyhvacguy Жыл бұрын

    Do you still need to braze the stub outs at the king valves at at the coil or is there a way to avoid brazing all together?

  • @alanlee4891
    @alanlee48913 жыл бұрын

    When I install unit at attic I like to run copper line from top to air handler Because oil will stay in coil will help extend the compressor life

  • @mikedickinson9730
    @mikedickinson97303 жыл бұрын

    Not only is the investment high on that tool, but, it seems to take more time than fitting and brazing.

  • @antmothirteen6540

    @antmothirteen6540

    2 жыл бұрын

    I lost my marker. I have to go home boss.

  • @maxthefrenchie-productions
    @maxthefrenchie-productions3 жыл бұрын

    Love your videos. stay brite soft solder is the one for me 75% of the time. Brazing the rest of the time.

  • @aaronsimon46
    @aaronsimon463 жыл бұрын

    Good work, very professional and I enjoy watching your videos

  • @euanburch8332
    @euanburch83323 жыл бұрын

    HVAC apprentice here. I've always been told not to blow in the copper pipes to remove any lose burrs. Because of the liquid it would create

  • @euanburch8332

    @euanburch8332

    3 жыл бұрын

    @Enormity thank you for your response

  • @user-vi4zp6ly6j

    @user-vi4zp6ly6j

    3 жыл бұрын

    Hvac apprentice what 3 outdoor numbers do you need to find the indoor temp split at your outside condensing unit without taking an indoor temp?

  • @User-be5yj

    @User-be5yj

    2 жыл бұрын

    @@user-vi4zp6ly6j trick question. There is none 😏

  • @user-vi4zp6ly6j

    @user-vi4zp6ly6j

    2 жыл бұрын

    @@User-be5yj Nope not a trick question? you can find the inside temp at your condenser keep thinking, look at the condenser and think of what it does. So trick to question is within the question, . God bless have fun ✌

  • @rodgraff1782

    @rodgraff1782

    Жыл бұрын

    That’s correct, never blow in the pipe. My apprentice always used to say that because they taught that in RAC school

  • @mr.r9505
    @mr.r95053 жыл бұрын

    I've heard of this but never seen it in action great video

  • @QualityHVACR

    @QualityHVACR

    3 жыл бұрын

    Thank you!

  • @mr.r9505

    @mr.r9505

    3 жыл бұрын

    @@QualityHVACR always quality stuff

  • @aquattadomdren6760
    @aquattadomdren67603 жыл бұрын

    yeah i could definitely see this tool making solo installs more appealing, pretty much could do any lineset by yourself by just popping into the attic or crawl a bit and linking up long runs $$

  • @BigmoRivera
    @BigmoRivera2 жыл бұрын

    Great Tool Nicely Done😉👍🏽 If You Need To Hold The Line Up So It Won’t Slide Down You Can Use A Tape Measure Extende Under The Line And Lock It

  • @GB-ue6wr
    @GB-ue6wr3 жыл бұрын

    I like that you don’t have to bother with flowing nitrogen or burning anything. I just wonder how long those o-rings will last...

  • @picklerix6162

    @picklerix6162

    3 жыл бұрын

    No nitrogen needed with Stay Brite 8 either. I used it for my last installation. I used a propane torch to melt the solder.

  • @cabbagesoup7879

    @cabbagesoup7879

    3 жыл бұрын

    Still have to. Look at the numb of copper at the condenser he is attaching to

  • @nessnesu6202

    @nessnesu6202

    3 жыл бұрын

    @@cabbagesoup7879 For this application he was relocating it so it was pumped down, cut and moved. But on a new install still need torches for outdoor unit or cut bell to attach press fitting to non-swagged part pipe.

  • @cabbagesoup7879

    @cabbagesoup7879

    3 жыл бұрын

    @@nessnesu6202 I’m well aware of this as stated in my comments. I’m saying that before this needs to be sold and pushed as a great tool they need to address the connections at the condenser and evaporator coils or what’s the point of having it. Ok sure I’ve cut an pumped down and moved an old system. Wow I get to press on a 90. That was well worth the thousands it cost for the tool. Would by these tools for each of my crews in a heartbeat if it truly was a no braze system from start to finish

  • @keenanwalker6597

    @keenanwalker6597

    3 жыл бұрын

    My company stopped using zoom lock because it sucked it doesn’t hold up to pressure over time

  • @bradpelc3429
    @bradpelc34293 жыл бұрын

    I’ll continue brazing, this kit could come free with the unit! I’d scrap it and braze the lines in!

  • @theredrepublic7973

    @theredrepublic7973

    3 жыл бұрын

    Cuz you’re a fucken idiot who doesn’t know how to use knew tools

  • @Diaszurana

    @Diaszurana

    3 жыл бұрын

    Then you can stay in the past and let everyone fly past you.

  • @PatIreland
    @PatIreland2 жыл бұрын

    When using a pipe cutter, in small increments, crank it down at different locations. I learned something today. TY.

  • @LtDMT
    @LtDMT2 жыл бұрын

    i haven't done much commercial but at least for me in new construction in residential areas brazing/swaging/bending the copper saves me a lot of time on trimming houses guess i'd have to use the tool to see 👍🏽

  • @notanewbie1718
    @notanewbie17183 жыл бұрын

    If that tubing is not perfectly round like the press lock fittings, there won't be uniform compression on the tubing and "o" rings. It's bound to leak eventually.

  • @chrisgonzalez5599
    @chrisgonzalez55993 жыл бұрын

    Keep it up bro I look up to you 💪 💯 👌

  • @luiselizalde6757
    @luiselizalde67573 жыл бұрын

    Really worth your time spent it, I really liked it, I totally recommend your videos, I really learned. Thanks man,

  • @maxprusak3970
    @maxprusak39703 жыл бұрын

    Great tool for some jobs. Really nice for work at hospitals, instead of having someone braze, another ignite the torch and someone else to spot you can just do your thing all by yourself. Saves a lot on labor.. 1 guy vs 3 guys per job

  • @HVACUncensored
    @HVACUncensored3 жыл бұрын

    Great video Zach. I’m gonna buy one of these tools for my company. We already have the pro press for water. I used one when they first came out not sure why I haven’t got one yet lol. Keep making these awesome videos brother 💪🏻💪🏻

  • @QualityHVACR

    @QualityHVACR

    3 жыл бұрын

    Thx man! I've got a trutrechtools link in the description for ya. :) RLS is offering a $500 rebate currently.

  • @davidbayles4732
    @davidbayles47323 жыл бұрын

    Love it! but looks like you still have to braze a peace off the coil and Condenser...? If I gotta pull torches out for that might as well hit it all.

  • @dodgerblue182able

    @dodgerblue182able

    3 жыл бұрын

    Yup!

  • @Diaszurana

    @Diaszurana

    3 жыл бұрын

    That is actually my issue. But if they ever make fittings to correct this, I will buy one immediately. $3500 may sound like a lot, but if you're good, it will save you enough time to squeeze in enough jobs that it will pay for itself in a few weeks.

  • @Diaszurana

    @Diaszurana

    3 жыл бұрын

    @Sven3xs no, I mean weeks. If I install an extra 2 systems a week with the time saved with press tools, the money made from. The installs will pay for the tool in a few weeks. Not year. Weeks

  • @perry2281

    @perry2281

    3 жыл бұрын

    Works good for Nat gas lines too. But I forgot to mark the depth..and it costs me.. So a guy can use it for plumbing water lines gas lines and refrigeration..lines. Very cool.. Costly Though.

  • @txbuzzard3260

    @txbuzzard3260

    2 жыл бұрын

    @@Diaszurana I dont know what kind of brazing youre doing that you can save enough time in 2 weeks to save 100$ worth of labor, much less 3500$. Not to mention the money lost every fitting you put in. I can sweat an entire lineset in 20 mins. Thats bending corners, sanding fittings/pipe, wrapping valves and lugging a torch around. You might do it twice as fast, but spend 20-100$ on fittings. Even if fittings were free. 10 mins saved per install? If you do one install per day for 2 weeks youre only saving 2 hours. If youre charging 1750$ per hour, yeah it will pay for itself in a few weeks. I need your customer base, because ill glady work for 1500$ hour.

  • @qaziumer1604
    @qaziumer16043 жыл бұрын

    Sir I am also ac technician and work in saudi Arabia but you are good ticher....inspired by your working 😍

  • @sufielectronics8131
    @sufielectronics81313 жыл бұрын

    Excellent job sir you done it very professionally

  • @pastormartinez4676
    @pastormartinez46763 жыл бұрын

    It seems helpful on “tight to braze spots”(particularly fire risk areas like the old insulation stuff in the wall on old houses) but I’d like to see if they hold up pressure in 5-10 years after so many cycles,specially on heat-pump systems which it’s twice as many and brutal on expanding and contracting the fittings! I’m not saying you’re wrong…but I might be right!

  • @Username-ng8jy

    @Username-ng8jy

    2 жыл бұрын

    Idk man. If it’s in a tough spot. I prefer to braze it. I would hate to have to come back to the right spot to fix a leak. That’s my take on it. I feel like anything with an o ring will leak eventually. Maybe not in 5 years. But 15 20 later.

  • @dexenationgracey1979

    @dexenationgracey1979

    2 жыл бұрын

    @@Username-ng8jy But you could say the same thing about a braze, there's no such thing as 100% leak free.

  • @suspect_fb

    @suspect_fb

    2 жыл бұрын

    @@dexenationgracey1979 yes there is

  • @dexenationgracey1979

    @dexenationgracey1979

    2 жыл бұрын

    @@suspect_fb No there isn't, copper will eventually weaken and start to leak. You can have all of your joints as sealed as possible but that metal will leak whether it's 10 years or 70 years. Something will cause a leak.

  • @RelyksTheG13

    @RelyksTheG13

    2 жыл бұрын

    Everything has a decay rate. Nothing is leak free ever not copper as a whole not flux and solder not o rings.

  • @antonlavey5540
    @antonlavey5540 Жыл бұрын

    You still have to braze in the copper at the service valves. Might as well just braze.

  • @diyhvacguy
    @diyhvacguy Жыл бұрын

    I just ordered one of these kits with your discount code. I hope you get some sweet comish from it!! Thanks bro 👊🏼 super excited to use this and save time on installs! Cheers

  • @mosears6808
    @mosears68083 жыл бұрын

    You talk about the stuff I am thinking about. Keep up the great work and make that money...!!!!

  • @jonathanhayes5194
    @jonathanhayes51943 жыл бұрын

    We love ours the tool paid for itself on a big refrigeration job we had!! Couldn’t have done it without it!!!!

  • @hvac526

    @hvac526

    3 жыл бұрын

    Where can I get this tool from

  • @joeb9600

    @joeb9600

    3 жыл бұрын

    Hopefully this iteration of these fittings is different. Have been on multiple vrf installs in condos where the ENTIRE job had to be redone because they failed after a few months. The fittings I'm talking about are no longer in service. But I'm skeptical AF of these especially with refrigerants becoming higher and higher pressure. Convenience is there - I just personally haven't been sold on these as a long term solution across our industry.

  • @Aquariun9iteMMare

    @Aquariun9iteMMare

    3 жыл бұрын

    @@joeb9600 my thoughts exactly...however this appears like it would pay for itself pretty, quickly. Plus the simplicity of it, its speed, and saving money on nitrogen and acetylene, this looks like its worth a shot.

  • @jonathanhayes5194

    @jonathanhayes5194

    3 жыл бұрын

    Prep is absolutely key for longevity of fitting

  • @joeb9600

    @joeb9600

    3 жыл бұрын

    @@Aquariun9iteMMare the risk of losing my reputation with my customer and the cost of the warranty repair is what stops me. At the end of the day, I trust a good braze - I don't put a lot of faith in these braze free solutions even though they may save time and lower costs IF it works perfectly and holds over time. There have been so many iterations of this exact thing and they all seem to go the same way. Your torches and acetylene pay for themselves too, I hope. You charge for them! IDK, maybe I'll try these on a residential side job and if it doesnt hold I'll go back and braze fittings in. I try not to be too close minded.

  • @acservicetechchannel
    @acservicetechchannel3 жыл бұрын

    Great job as always Zack!

  • @1971omi

    @1971omi

    3 жыл бұрын

    Can't rely on Oring. Concept is good but overtime I don't know how it holds up

  • @DClough

    @DClough

    3 жыл бұрын

    @@1971omi the o rings are recessed inside the fittings and seated in that recession so it kinda helps protect them and keeps them locked in position so when you put pipe in and out of the fitting it doesn’t really wear down that oring I totally understand why the old timers prefer solder but I mean especially in MA they are making it harder and harder to solder like in Boston if I wanna solder a joint I have to fuckin pull a permit and get a firefighter to come out and watch me do it even if it’s just one 5 minute joint I have to do that so why would I waste all that time? Time is Money friends.

  • @moonlightacmaintenance3232

    @moonlightacmaintenance3232

    3 жыл бұрын

    I have a 25 yr old Ford F-350 with original AC , O-rings and components.

  • @lordjaashin

    @lordjaashin

    3 жыл бұрын

    @@DClough MA is just stupid. permit for soldering?! lmao

  • @1971omi

    @1971omi

    3 жыл бұрын

    @@moonlightacmaintenance3232 I do refrigeration my friend. That set up is for newbie dyi jobs not any seasoned tech. Car hold up max 1lb 134A or R12. Some jobs I do is Propane refrigeration. I do know my stuff. O ring on 134A maybe but not a job due to laziness that going to cost arm and leg later on. Air to the system due to leak. BRAZING, Evacuation, virgin refrigerant then TEST ALL FOR THIS BECAUSE DIDN'T WANT TO BRAZING. WOW.

  • @williamrobbins2939
    @williamrobbins29393 жыл бұрын

    I'm from the ole school so I do love to braze my silver but I can see this as a great option instead of having to go through the headache of getting a hot permit in historic areas or in public buildings . But I do wonder about the longevity .

  • @georgekolos5255
    @georgekolos52553 жыл бұрын

    Fixed an electrical problem on a WI freezer earlier today that we installed still running 502 in 1985! Original compressor and TXV!

  • @geraldhenrickson7472

    @geraldhenrickson7472

    5 ай бұрын

    Wait, what?

  • @fsotomayor96
    @fsotomayor963 жыл бұрын

    $3500! for tool and 19.12 for a 90' elbow....yep I'll keep brazing 😂

  • @TaRgEt0ZeRo

    @TaRgEt0ZeRo

    3 жыл бұрын

    hahaha thats what i was thinking 3500$... and 20$ buck for a fitting lol. Labor cost that is pretty high here doesn't make it worth it still. To costly.

  • @1971omi

    @1971omi

    3 жыл бұрын

    Soldering or brazing over that fancy unreliable Oring. I will take brazing or Soldering any day, regardless of the job.

  • @floyddavis263

    @floyddavis263

    3 жыл бұрын

    Does anyone else think it pointless, if you still have to braze stub outs on the service valves? Also the coil, so, if I have to pull out the torches. Then that defeat the purpose 🤷‍♂️🤷‍♂️🤷‍♂️

  • @juniordude8341

    @juniordude8341

    3 жыл бұрын

    Have you heard of revolutionized? Just like the iphone and internet brazing actually will be a thing of the past sorry to say it 🤷🏻‍♂️

  • @JohnDavis_90

    @JohnDavis_90

    3 жыл бұрын

    @@juniordude8341 not yet tho

  • @HVACGUY
    @HVACGUY3 жыл бұрын

    Call me old school, but I’ll be the last to adapt Press fittings. I’m waiting on a video of someone fixing a leak on one of these by cutting it out and brazing.

  • @TheJordanwright

    @TheJordanwright

    3 жыл бұрын

    Happened to me a few times. Still quicker and more cost effective. Keep being old school so the newer guys can take your work lol

  • @Manzilla56

    @Manzilla56

    3 жыл бұрын

    @@TheJordanwright So true. They said the same thing about sharkbites. Now everyone uses them. These things have been used in Europe for awhile now.

  • @lordjaashin

    @lordjaashin

    3 жыл бұрын

    @@TheJordanwright customer does not care whether you are brazing or press fitting. so why do you think you can get more work by press fitting? lol stop talking like a clown

  • @TheJordanwright

    @TheJordanwright

    3 жыл бұрын

    @@lordjaashin less time spent braising? Are you dumb

  • @lordjaashin

    @lordjaashin

    3 жыл бұрын

    @@TheJordanwright are you? because this press fitting doesn't work for coils and discharge line connections especially on r410a systems. you definitely have to bring out your brazing stuff to complete the job. so whats the point of this press fitting especially when it costs $2000+?

  • @bmorris8276
    @bmorris82763 жыл бұрын

    I recall these at Ferguson a couple years back, after the demo I was iffiy at best, then the price drop on me........yea Ill keep doing it with the flame thank you.

  • @bayouflats5054
    @bayouflats50543 жыл бұрын

    Pretty cool. Thanks for the demo. Manufacturers now need to produce units with stub-outs ready for press fittings. Until then…., my torch and nitrogen is already set up

  • @JayBirde

    @JayBirde

    2 жыл бұрын

    I had a discussion in March with 2 Ruud engineers at a DSC meeting and they are planning on stopping the swaging of both the outdoor units and the coils in the near future. Also, Rectorseal has a fitting that goes OVER the swaged end on one side and the pipe goes in the other end like a Shark Bite fitting. No press necessary.

  • @derekmc9580
    @derekmc95803 жыл бұрын

    Ill stick with the Hilmore and braze rod. Even adding nitrogen to the mix its gonna be way cheaper and i can trust I’m not gonna have any leaks.

  • @adamrspears1981
    @adamrspears19813 жыл бұрын

    The price makes it obvious why brazing is here to stay.

  • @Engineerisaac

    @Engineerisaac

    3 жыл бұрын

    Agreed.

  • @antmothirteen6540

    @antmothirteen6540

    2 жыл бұрын

    @Sven3xs the cost of the fittings alone. Even without the tool cost.

  • @dominicm2175

    @dominicm2175

    2 жыл бұрын

    I was just on a job with something like 100 condos , each with multiple units. The guy had a press tool and no question it paid for itself 10 times over in saved labor

  • @ianicus123

    @ianicus123

    2 жыл бұрын

    @@dominicm2175 pft, can literaly braze a joint in less than a minute, what labor lol

  • @dominicm2175

    @dominicm2175

    2 жыл бұрын

    @@ianicus123seems to me that with brazing there is more time spent to set up with acetylene and nitrogen and fire safety considerations. On that job site I mentioned with over a hundred condos and multiple units per condo the mechanical company foreman says it was a “ no brainer” using the press fittings

  • @DavidHernandez-gt9bo
    @DavidHernandez-gt9bo3 жыл бұрын

    Nice tool makes a lot sense as long as the o - rings hold up no flame 🔥 means less hazard ! I know it’s probably expensive but it will pay for itself quickly. Once again very clean installation and solid craftsmanship . 👍

  • @stevew1268
    @stevew12683 жыл бұрын

    Our company used zoomlock fittings for a few years...they tend to leak a lot. All we use now is the maxi pro refrigeration fittings. Rothenberger makes the press tool for the fittings. Haven’t had a single leak yet

  • @1971omi

    @1971omi

    3 жыл бұрын

    Give it a time.

  • @rogerwhiting9310
    @rogerwhiting93103 жыл бұрын

    When I took my refrigeration course my instructor showed us that using plumbing solder was plenty strong enough for refrigeration copper connections. I have never had a failure and you dont get all the oxidation inside the pipe from extreme heat.

  • @picklerix6162

    @picklerix6162

    Жыл бұрын

    StayBrite 8 is a soft solder used for HVACR applications. In the past, other types of soft solder have been used on refrigerant lines.

  • @jeremyhall7951
    @jeremyhall79513 жыл бұрын

    How do you get a fitting off if it doesn't press correctly or leaks?

  • @jeremyhall7951

    @jeremyhall7951

    3 жыл бұрын

    If you have to braze to the unit service valve anyway why not just turn the lineset into unit and do away with 4 joints?

  • @jeremyhall7951

    @jeremyhall7951

    3 жыл бұрын

    Was this video paid for by the tool manufacturer?

  • @jeremyhall7951

    @jeremyhall7951

    3 жыл бұрын

    I'm sorry if I'm asking too many questions or if they are annoying. I'm just asking as they come to mind....

  • @jeremyhall7951

    @jeremyhall7951

    3 жыл бұрын

    What are the maximum pressure of these fittings? Will coil cleaning chemicals attack the seals? Are these seals compatible with all refrigerants and oils?

  • @Deltron6060

    @Deltron6060

    3 жыл бұрын

    @@jeremyhall7951 obviously a sponsored sales pitch.

  • @paulrozinski1488
    @paulrozinski14883 жыл бұрын

    Love the tool. Brazing is such a mess by comparison . One question about the fittings. I noticed on the outdoor vertical line, when you crimped the top side, the fitting flared open kind of like an upside down umbrella. Do you think that opening (if left exposed) might be a trap for water to accumulate ?? I know that a suction line would typically be insulated but that leaves the liquid line. Comments, thoughts welcome😊👍

  • @andypatterson8991
    @andypatterson89913 жыл бұрын

    Love it man. Love your videos. Inspiring. Similar to sharkbite fittings for plumbers minus the press.

  • @stevee7774

    @stevee7774

    3 жыл бұрын

    Many plumbers are also using pro press fittings similar to these. Not surprisingly the reviews are as mixed among plumbers as they seem to be among the HVAC techs here!

  • @linktothepassed
    @linktothepassed3 жыл бұрын

    It isn't the copper that's getting reamed, it's Zack's wallet.

  • @mikeclinton6027
    @mikeclinton60273 жыл бұрын

    By the time he gets done with piping, I would already have been on a vacuum. Plus, how did he connect a coupling to the condensing unit. And the o rings are only good for 25 years.$$$$$"

  • @dustinpomeroy8817

    @dustinpomeroy8817

    2 жыл бұрын

    From my experience no system will go 25 years ,the fittings will last as long as the system

  • @joeljimenez5780
    @joeljimenez57802 жыл бұрын

    Thank You for sharing your RLS tool. Good Job! Good Video. I do have 2 more processes, which I observed MUST be executed for this job! # 1) Please use a small Nitrogen cylinder with blowing Kit/Gun to clean pipe-works/fittings . DO NOT and NEVER-EVER blow air through your mouth to pipes? To avoid contaminating / adding moisture to your line set / system. #2). Please rub compatible refrigerant oil @ the O-Ring prior to insertion to avoid possible damage.

  • @rogeriosoares8528
    @rogeriosoares85282 жыл бұрын

    Happy, fico feliz de ver profissionais com equipamento certo para o serviço e eu aqui capengando ferramenta.

  • @tomdolan8811
    @tomdolan88113 жыл бұрын

    The big question, just how long does the “O” ring last before it begins to deteriorate❓

  • @Keegeth
    @Keegeth3 жыл бұрын

    Damn, some techs in the comments despise pro press type fittings.

  • @actechchris

    @actechchris

    3 жыл бұрын

    I don’t despise them. Never used them. Interested though.

  • @Keegeth

    @Keegeth

    3 жыл бұрын

    @@actechchrisI've been trying bro have my boss OK a full pro press boiler install.

  • @Republican317
    @Republican317 Жыл бұрын

    The attic coupling really drove home the benefit of it 👍

  • @hvacguy8362
    @hvacguy83623 жыл бұрын

    Great video but just something I would never consider using. Thumbs up great content 👍

  • @antoniodefilippis323
    @antoniodefilippis3233 жыл бұрын

    Rumour has it viega stayed away from Press ACR fittings because of outdoor climate with a rubber pressed conection asking for a failure in future. braze with nitrogen old school

  • @theredrepublic7973

    @theredrepublic7973

    3 жыл бұрын

    Do you still paint a whole house with a paint brush?

  • @JayBirde

    @JayBirde

    3 жыл бұрын

    Viega Pro Press is a 3 crimp system and they very much exist! The rep offered to supply all the fittings at no cost for my VRF lab, but we went with RLS because we had an account with them.

  • @Paulie1232
    @Paulie12323 жыл бұрын

    I'm a old school tech, I'll braze till I die...

  • @theredrepublic7973

    @theredrepublic7973

    3 жыл бұрын

    Nobody asked dumbshit. You act like there’s pride in that

  • @EastDallasKicks

    @EastDallasKicks

    3 жыл бұрын

    @@theredrepublic7973 What’s with the hostility. Atleast he knows how to braze. You’re probably pissed because you go trough multiple rolls just to get one line brazed.

  • @EastDallasKicks

    @EastDallasKicks

    3 жыл бұрын

    @@wreckitbmx2698 Oh I see, you’re enraged. Grow up kid.

  • @Diaszurana

    @Diaszurana

    3 жыл бұрын

    @@EastDallasKicks the hostility is that it's people like him that slow down progress, and frankly their arrogance is frustrating.

  • @EastDallasKicks

    @EastDallasKicks

    3 жыл бұрын

    @@Diaszurana People like him dont create or innovate non brazing processes nor choose to use them. Yet others create nonetheless. He isnt slowing down anything.

  • @HsingSun
    @HsingSun3 жыл бұрын

    As a home owner, I did brazing many years ago for few copper lines and I had to use a piece of metal to block the drywall to avoid burning.

  • @FBHSswimmer2006
    @FBHSswimmer20063 жыл бұрын

    That thing is pretty slick. Looks like it makes your life easier

  • @joshuat2751
    @joshuat27513 жыл бұрын

    pro press somewhat near compressor? i give those a few mo nths before a leak appears. .-. i love pro press for plumbing dont get me wrong, but i dont think it belongs in HVAC installs.

  • @jeremybelcher6681

    @jeremybelcher6681

    3 жыл бұрын

    Why?

  • @Sesamestreet9080

    @Sesamestreet9080

    3 жыл бұрын

    @@jeremybelcher6681 probably higher pressures and temperature differences. Only can wait and see

  • @joshuat2751

    @joshuat2751

    3 жыл бұрын

    @@jeremybelcher6681 because pro press does not make as good as a seal as regular solder. Especially being close to the compressor there is a-lot of vibration and it will just wiggle it loose after x amount of time. i've personally had to go back behind a few installs with these on them and put in regular solder joints.

  • @RickSegui
    @RickSegui3 жыл бұрын

    Nobody ever talks about the very high price for the device and crimp on fittings!

  • @anthonyelectric6045
    @anthonyelectric60453 жыл бұрын

    All I can say is wow!! For exposed work you can beat that invention. Nice!!

  • @WaqasAhmad-hd7vz
    @WaqasAhmad-hd7vz3 жыл бұрын

    Great job man....Best of luck for your future..

  • @georgekolos5255
    @georgekolos52553 жыл бұрын

    I'm old and new school in doing what I do for going on 30 years in this trade. Thank you much but I'll stick with brazing with oxy/ acetylene running nitro when possible and haven't had a leak on any of my joints since I can remember with my practice/ skills of brazing over 2" suction lines with proper tips minus alone silver brazing skills say stainless to copper of metric sized fittings that I doubt no such press shit can do Unbelievable how such top union companies that use such don't know shit about properly piping using oil return traps etc.

  • @josecalletano6316
    @josecalletano63163 жыл бұрын

    I mean, you still got to braze the extension in on a new install.

  • @QualityHVACR

    @QualityHVACR

    3 жыл бұрын

    Not always, some manufactures have long enough stub outs on valves that can be cut off. It's not about one way or the other, do what works best for each situation.

  • @JayBirde

    @JayBirde

    3 жыл бұрын

    True! I have noticed that Payne units aren’t swedged on the liquid side, so winning there!

  • @hughholt121
    @hughholt1213 жыл бұрын

    Been out of the trade for twenty years but I would have taken a piece of 3/4 inch ENT (blue smurf) and put it on the 5/8 copper line at the entrance to the attic , bent a nice smooth elbow at that point and saved having to make a joint in that area. The rubber insulation will fit over the bend if you use some baby powder. 1 inch works on 3/4 pipe . Something I happened on as an A/C and electrical Contractor. The tool seemed to work but I would still prefer the old brazing method. But very interesting post.

  • @mrdixiewreckedpsn9018
    @mrdixiewreckedpsn90183 жыл бұрын

    I leave the core tool on and valve off my micron gauge before letting the refrigerant loose got oil in it once and it took some doing to get it working right again

  • @cdubs1723
    @cdubs17233 жыл бұрын

    Why the elbows when you have a bender? Eliminate 2 potential leaks for each instance by bending instead. Guess you needed to show all aspects of the tool in order to get it for free. I’m not buying one.

  • @georgekolos5255

    @georgekolos5255

    3 жыл бұрын

    Trane and other manufacturers get bending incorrect these days.. Recycled copper is not what it used to be not just long ago. 6 RTUs we put up not long ago all had cracked discharge piping cracks in factory 90 bends out of scroll compressors resulting in losing all charge in all them in one season of operation! Vibration problem? Was told to cut out and repipe them with proper 90° fittings by Trane

  • @briangc1972
    @briangc19723 жыл бұрын

    Over priced toy offering a solution to a non existent problem. There are no long term studies to see how those fittings last when subjected to constant vibration and hydraulic pressure fluctuations. Brazing is just as fast. Brazing costs less; for the price difference of just 2 long radius elbows, I can buy a full refill of Acetylene. Add a coupler or two and I'm far better off financially brazing. Quality brazing rod (15% silver) lasts a lifetime and then some. I've been a licensed HVAC contractor for over 20 years, seen a lot of fads come and go.

  • @merckxherve9116

    @merckxherve9116

    2 жыл бұрын

    Al is true, but next year we have propane mini-splits in Europe. I dont like brazing with trapped gas inside and is also forbidden to do it in Europe. Also hvac in Europe it is not alone mini splits, but also floorheating with air/water heatpump. On the water side we press every connection with tesame tool. Thus a non existing problem for the future?

  • @briangc1972

    @briangc1972

    2 жыл бұрын

    @@merckxherve9116 Obviously you will need to pull the system into a vacuum during recovery of flammable gasses then purge the system properly with nitrogen. Our EPA wants to force us to use flammable refrigerants in a couple years. I foresee (in a couple years) a few dead service guys that don't follow procedure

  • @stevensanderson9615
    @stevensanderson96153 жыл бұрын

    Great videos man. Your professionalism shows in your work. Love your videos. Where do I purchase your quality hvac hat?

  • @Rhahdhdn
    @Rhahdhdn3 жыл бұрын

    I went to school recently and we used these fittings for our refrigeration project. They are neat but I think the cost per fitting is a lot more.

  • @Diaszurana

    @Diaszurana

    3 жыл бұрын

    It is, but you can always pass that to the client. It's not like you're screwing them over, either. That 30-60 minutes you save is 30-60 minutes less time waiting for cooling.

  • @DragonflyAcres2022
    @DragonflyAcres20223 жыл бұрын

    Good tool to use when you require a fire watch.thank you for sharing

  • @nicolasminicuci7083
    @nicolasminicuci70833 жыл бұрын

    Specifically talking about the tool itself it actually seems cool and convenient. Everyone in the comments complaining about leaks in 5-10 years as if the customer is going to expect a free callback to fix it that long after lol. Atleast the tool will keep us in business! 😂

  • @wblynch

    @wblynch

    2 жыл бұрын

    Thanks for the warning. -a homeowner

  • @terrygrant8126
    @terrygrant81262 жыл бұрын

    I learned something today!....thanks friend!

  • @peterrivas2064
    @peterrivas20643 жыл бұрын

    Awesome I love this technology. Quick question do they make a kit for all the different fittings or do you have to buy separately and individually spec out?

  • @BurntLemmons
    @BurntLemmons Жыл бұрын

    Our company uses the Milwaukee version. It’s nice for large commercial installs. We braze in residential.

  • @malcolmwhite821
    @malcolmwhite8213 жыл бұрын

    25 years in trade. Last 15 in Controls. Crazy how things change. All Brazing when I did this.

  • @danf16dcc38
    @danf16dcc383 жыл бұрын

    The press tool sounds great, it saves time and dont have to flow nitrogren. But there are videos that show fittings leaked or even came apart. Might not have been installed correctly. I'll keep brazing. Nice demo though

  • @Debra758
    @Debra758 Жыл бұрын

    Thank you very much for such kind of great video , I have a question please Is there an adapter or connector to prevent the leakage of the air conditioner gas when removing the air conditioner gas pipes?

  • @1wettfloor
    @1wettfloor2 жыл бұрын

    You give us alot of information, im new to your channel I'm wonder what boots are you using they look very comfortable

  • @MichaelAnderson-py1ej
    @MichaelAnderson-py1ej3 жыл бұрын

    Price, and just the time it takes to do each fitting. I can see this being great inside an apartment building when you don’t want to braze.. but just a re and re I think brazing is the way to go. It was super quick... lol easy yes but not quick

  • @vahorashebaj4133
    @vahorashebaj41332 жыл бұрын

    Great work zack

  • @modestohodesto7140
    @modestohodesto71403 жыл бұрын

    Nice work. Love your videos. Question will the press work pressing pipe connected right out of the condenser and evaporator ? Thanks

  • @donnierobertson3088
    @donnierobertson30883 жыл бұрын

    Great job and video like always

  • @b-2466
    @b-24663 жыл бұрын

    #1 hvac/r channel

  • @illusionz1
    @illusionz12 жыл бұрын

    I will be doing a lot of apartment changeouts with the air handler having the refrigerant lines dangerously close to insulation, studding, and drywall. This will be perfect... I noticed the kit does not come with a 3/4's jaw... Do the jaws go by inside diameter (5/8's jaw for 3/4 OD) or outside diameter (3/4 jaw for 3/4)?

  • @khalilhq1981
    @khalilhq19813 жыл бұрын

    Hi Zack, thanks for the video, the A/C port where still welded, so what is the use of the press? Can you press on a new installation? No welding needed?

Келесі