How to Calculate Gas Load | Plumbing 101

Do you know how to calculate the gas load for your plumbing? Gas load calculation can seem daunting, but with a little practice, you can do it like a plumbing pro! This is an essential skill for plumbers, and in this video, I walk you through the process step-by-step.
▶️ Recommended Playlist: • How to Become the BEST...
🔔 Subscribe for more AWESOME plumbing videos: / @rogerwakefield
⭐️ Become a Member TODAY: / @rogerwakefield
________________________________________________________________________________________________
✅ Connect with me:
Instagram - / _rogerwakefield
Twitter - / _rogerwakefield
Tik Tok- / rogerwakefield
Reddit- / rogerwakefieldposts
LinkedIn - / rogerwakefield
✅ For business inquiries contact me at contact@rogerwakefield.com
________________________________________________________________________________________________
🔴 Links:
Check Out My Merch! - tuberturds.creator-spring.com/?
My Free Mini-Course- bit.ly/rogersfreeminicourse
My Networking Secrets That Grew My Plumbing Business FAST - bit.ly/rogersfreeguide
My Recommended Plumbing Study Guide -amzn.to/2RgYEn5
________________________________________________________________________________________________
Thanks for watching! I'm Roger Wakefield, The Expert Plumber, and welcome to my channel. On this channel, it's ALL about plumbing. We play games, we experiment, and we have FUN here, talking and learning about all things plumbing!
____________________________________________________________________________
🎥 Gear We Use:
Coolest Clock Ever - amzn.to/31CjLkW
Main camera - amzn.to/2RCyj1F
Lens for main and Second cameras - amzn.to/2SM7
Second camera - amzn.to/2SdzfdQ
My microphone - amzn.to/2FEvN8s
XLR Interface - amzn.to/2RDqskj
Wireless Lav Mic - amzn.to/2HenuRp
Tripod to hold our camera - amzn.to/32aI7Dj
Our studio lights - amzn.to/2Zv2R6O
*NOTE: This description contains affiliate links that allow you to find the items mentioned in this video and support the channel at NO COST TO YOU. While this channel may earn minimal sums when the viewer uses the links, the viewer is in NO WAY obligated to use these links. Thank you for your support!

Пікірлер: 68

  • @Lonzohiggins999
    @Lonzohiggins999 Жыл бұрын

    After many educational videos to use as context I finally feel like I fluently know the steps from start to finish to do this since you basically summarized it quick and easy here. To those who don't get it the first time looking into the code books chart might get some dots to connect

  • @taa347
    @taa3475 ай бұрын

    I'm going for my plumbing inspector's license and this is really one of the only things I just never got a chance to learn so thank you so so much for making this video.

  • @pandoxity9181
    @pandoxity9181 Жыл бұрын

    I'm 18 and trying to get into a plumbing apprentice and been watching your vids for tips and to jumpstart my knowledge so thanks for the vids!!!! great explanations

  • @RogerWakefield

    @RogerWakefield

    Жыл бұрын

    That is awesome! I love hearing that, good luck to you!

  • @jenko701
    @jenko701 Жыл бұрын

    The DR phill of plumbing. Great channel.

  • @st3vohhhh
    @st3vohhhh Жыл бұрын

    Great refresher!

  • @robertsarhanmd6433
    @robertsarhanmd64335 ай бұрын

    Excellent Professor, Thank You, Robert

  • @tjpatz2584
    @tjpatz2584 Жыл бұрын

    Great video!

  • @boby115
    @boby115 Жыл бұрын

    You will want to add 3 or 4 feet for everyone of your fittings. Roger’s understanding is correct but his explanation is somewhat confusing. Been in the gas industry for over 35 years , rather than me explain the correct way on sizing gas pipe, I invite you to go to Gray Furnace Man on KZread (gas line sizing video), there’s no better man to explain gas line sizing & appliance line drops on KZread . After watching his video on line sizing, let me know what you all think👍 (I can assure you, no one should have any arguments after watching).

  • @kenbrown2808
    @kenbrown2808 Жыл бұрын

    and this is why smart gasfitters in my area have started running a dedicated line to the water heater, if it's not the first point in the run. then they can run it at a higher pressure if they need to, to accommodate a tankless.

  • @mobilecommunicationsnetwor5268
    @mobilecommunicationsnetwor5268 Жыл бұрын

    Will the meter need to be changed for your tankless example ? What is the residential output side of the gas meter? Normal installation size?

  • @ron4274
    @ron42744 ай бұрын

    4:38 After correcting the small math error (257+160=417), the 1.25" pipe would need to be extended back another branch in the video example. (Easy for me to say, I'm not trying to write backwards and do math at the same time.) Worth mentioning too that fittings add more "equivalent length" than straight pipe and can sometimes bump the results up a pipe size. Unfortunately, physical installations are rarely as straight forward as paper plans (lol).

  • @larrytheplumber9851
    @larrytheplumber9851 Жыл бұрын

    Good shyt

  • @DJSephEntertainment
    @DJSephEntertainment2 ай бұрын

    So when you get to the water heater you reduce to 3/4 which the tankless accepts?

  • @wintonhudelson2252
    @wintonhudelson2252 Жыл бұрын

    Add the lineal feet each ell or branch of a tee to the O.A.L. piping structure. Rinna tankless at 199,000 BTU are sensitive to gas pressure drops and water pressure drops. Main symptoms are won't come up on high fire.

  • @markmonaco8901
    @markmonaco890111 ай бұрын

    Thank you very much

  • @RogerWakefield

    @RogerWakefield

    11 ай бұрын

    Any time

  • @ChefBoyareB
    @ChefBoyareB Жыл бұрын

    I learned that 257 + 160 = 317 today.

  • @ricksanchez6411

    @ricksanchez6411

    Жыл бұрын

    I thought I was the only one who saw that

  • @perrypstokes9868
    @perrypstokes98682 ай бұрын

    1/2 to 1 pound system with 3 appliances anything over 20 feet of run if u can tie it right outside ur always good

  • @johntruitt5899
    @johntruitt5899 Жыл бұрын

    Hey roger do you still have your plumbers cut and thread all of the gas piping you install? Or do you use csst (corrugated stainless steel tubing)?

  • @lactobacillusprime
    @lactobacillusprime Жыл бұрын

    writing in mirror alphabet real time is quite a little trick you're seem to be doing here! :)

  • @leonardoaguilar1357
    @leonardoaguilar1357 Жыл бұрын

    Thank you 🙏🏻 very much 👌🏻👌🏻👌🏻👌🏻👍🏻👍🏻👍🏻

  • @RogerWakefield

    @RogerWakefield

    Жыл бұрын

    Most welcome 😊

  • @Richard.Sanchez
    @Richard.Sanchez Жыл бұрын

    How do you find the inlet pressure pressure drop and specific gravity?

  • @williammontgomery2942
    @williammontgomery29422 ай бұрын

    Great video Roger!! Quick question; is there a way to measure the BTU from the end of a branch? I want to replace a 150K BTU firepit burner with a 240K burner. Is there a way to determine if enough gas is available to go to 240K or will I need to use your video and get my ruler and calculator out!! Cheers!!

  • @yermoffroad
    @yermoffroad Жыл бұрын

    Is pressure drop what the overall pressure will drop to when everyhing is running or how much it will drop from the original supply pressure?

  • @SpartanIV

    @SpartanIV

    Жыл бұрын

    I'm not a plumber but I believe the pressure drop of the table is the acceptable pressure drop with everything utilized. If you look at tables with higher pressure drops the BTUs that can be supplied by any pipe diameter goes up. That's because you're gaining more capacity at the sacrifice of pressure. What is an acceptable pressure depends on the pressure your gas regulator is providing and what your appliances specify as the minimum.

  • @jacobkindsvatter4055
    @jacobkindsvatter4055 Жыл бұрын

    I enjoy running gas pipe threading is the cheapest and most reliable way to do it but i would like to hear some thoughts on other brands like trac pipe, ward flex, and mega press, i have done all of the above and still threading is still my favorite way to do it

  • @Allintn22

    @Allintn22

    Жыл бұрын

    I agree

  • @johngraziano6652
    @johngraziano6652 Жыл бұрын

    Looking for some advice doing lot of research and asking questions, im not sure if my gas meter and pipe set up is ok to run a tri fuel generator and or some of my gas appliances, mostly my NG furnace . some say its ok, some disagree. MY GAS METER INFO .5-7 WC , (1.2-1.7 kPa W.C.) and 1000 BTU a cubic foot . so my regulator reads 'B42R ORI 1/8 5-7 IWC 125 PSIG MAX 8/08 The meter says AC-250 250 C.F.H @ 1/2 DIFF. MAOP 5PSI. my gas furnace furnace draws 120k, water heater draws 40k, I have a gas drier and stove, but during an emergency, wont be using them,, A Trifuel Generator I was looking at is CHAMPION TRI FUEL GENERATOR REQUIREMENTS Nominal fuel rating- 1000btu a cubic foot. Fuel supply size-1/2inchFNPT. Fuel supply pressure 5-7wc. Max flow rate 135000 btu MY NG LINE LAYOUT I have a 3/4 pipe going from the main 1in to the back of the house,straight line directly opposite the meter aprox 25 ft. When the 3/4 in pipe exits the house, I have a shutoff valve and a 1/2 reducer so as to attach a 1/2 flex hose to the generator. ( Off the 1 inch main are the branches for the furnace ,drier water heater and stove and now the generator line) Thanks for any advice you can give John

  • @lyricstogo1463
    @lyricstogo1463 Жыл бұрын

    What's the the recommended plumbing materials to study for improvement?

  • @paralellosll3849
    @paralellosll3849 Жыл бұрын

    Oh my god... I finally found someone who does math like me 🤯

  • @mattmas8640
    @mattmas86404 ай бұрын

    Question for you. I have 70’ for my furthest distance. However, I want to install a 199,000 tankless water heater. The tankless water heater only has 3/4” connections. Using the chart, 3/4 is not supposed to be utilized even in a branch off of a 1-1/4 just to supply the water heater. The chart would state that I would need a 1” connection to the water heater. How do you get around this to meet code? Do you just reduce down to 3/4” close to the water heater?

  • @ron4274

    @ron4274

    4 ай бұрын

    Correct, just reduce down to 3/4" pipe near the TWH. If you refer to the sizing table in the video, 3/4" schedule 40 metallic pipe will support a BTU load of 247 cu. ft./h (assuming the same conditions) for an "equivalent length" of 20' (Note: The length of fittings is calculated differently than straight pipe - search online for a table that provides the equivalent length of fittings when sizing gas piping).

  • @nicholastrentini1999
    @nicholastrentini19993 ай бұрын

    How hard is it when it comes to measurements and plumbing

  • @danielwilson9049
    @danielwilson9049 Жыл бұрын

    So if the water heater is the first thing on the line after the meter, do i still measure all the way to the furthest point or just to the water heater?

  • @pq9254

    @pq9254

    2 ай бұрын

    Of course

  • @nortonplumbing9552
    @nortonplumbing9552 Жыл бұрын

    This is the biggest thing I have to explain to my customers. Then with the electric tankless option, it is kind of the same...do you have enough power to run this thing? It is never a clean swap.

  • @wtfpopupforyoutubechanel1500
    @wtfpopupforyoutubechanel1500 Жыл бұрын

    I was hoping you would talk about upgrading to a 2lb system also to prevent redoing pipping if it uneconomical to change gas pipe. You could run a 2lb system and put a regulator at each appliance. Or just 2lb to your utility room and have a regulator there.

  • @holdenruppert7638

    @holdenruppert7638

    6 ай бұрын

    We just did this on a job where a gentleman had a 1’’ line to a generator which should’ve been at least 1 1/4”. We had the gas company change the meter to a red face meter, medium pressure 5lb of gas coming into the house added a regulator at each appliance except the 1” line to the generator and it worked just fine. Only case it wouldn’t work is if they had every gas appliance on at one time which isn’t likely

  • @joeheiliger3956
    @joeheiliger3956 Жыл бұрын

    How does this differ when using regulators?

  • @nathancastro7942
    @nathancastro79428 күн бұрын

    How do you know what the meter out is?

  • @ShrimpCracka
    @ShrimpCracka Жыл бұрын

    so this applies for a meter thats 7wc? or a meter that is 2psi?

  • @Tommyhawk068

    @Tommyhawk068

    Жыл бұрын

    MTR would have to be pushing 2LBs if he’s basing his calculations off 2LBs.

  • @nicknickolette2777
    @nicknickolette2777 Жыл бұрын

    One thing not covered here is can the meter pass the proper amount of gas for the application. In this case you'd need atleast a 425 cfh meter

  • @andrewwelch5668
    @andrewwelch5668 Жыл бұрын

    I know these videos are intended for the purpose of giving pointers and advice to plumbers and gas fitters as well as for those striving to be plumbers and gas fitters. You have to figure that some DIYers are looking at this stuff too and thinking that they can do it as well...without the proper training and licensure. Only takes 1 moron to THINK they can do this before they make a dangerous situation for themselves and their neighbors messing with gas piping. DO NOT TRY THIS IF YOU DON'T KNOW WHAT YOU'RE DOING!!!

  • @kenbrown2808

    @kenbrown2808

    Жыл бұрын

    remember: a water leak can make your house fall down. a gas leak can make your house fall up.

  • @matthewwright1813
    @matthewwright1813 Жыл бұрын

    Mr. Wakefield, could you do a video on Water Column for the same system here?

  • @andrewwelch5668

    @andrewwelch5668

    Жыл бұрын

    What do you mean by "Water Column"?

  • @matthewwright1813

    @matthewwright1813

    Жыл бұрын

    Water column is an alternative way of expressing measurements of pressure. This measurement is defined as the pressure produced by a 1-inch by 1-inch column of water with a specified height.

  • @Helpfulsuggestions
    @Helpfulsuggestions Жыл бұрын

    I’m confused as all this still apply if it’s a five psi system ??

  • @billcryer3389
    @billcryer338910 ай бұрын

    Sizing has is simple

  • @billcryer3389
    @billcryer338910 ай бұрын

    Sizing gas pipe is simple.

  • @13072b
    @13072b Жыл бұрын

    What happens if meter is 250 or less .

  • @ricksanchez6411

    @ricksanchez6411

    Жыл бұрын

    Gas company will up size

  • @thewaterheaterfactory
    @thewaterheaterfactory Жыл бұрын

    Is there an expansion tank for gas lines? To expand the volume? Oh wait did I just invent that? Great video thanks!

  • @dr.roostertail9274
    @dr.roostertail92746 ай бұрын

    You casually say that you need the proper chart for your area to determine pressure drop. I cant find info anywhere! How do you find the local information?

  • @mondavou9408
    @mondavou94089 ай бұрын

    I learned its hard to write backwards

  • @RogerWakefield

    @RogerWakefield

    9 ай бұрын

    it is quite tough lol

  • @Seven7Pain1
    @Seven7Pain1 Жыл бұрын

    or save your brain and like Rinnae water heaters taught me tankless outside heaters place them right beside the meter and 90 percent of time that will work

  • @spowehnmichael
    @spowehnmichael Жыл бұрын

    can I hack it to save money tho? I switched heater, range and hot water heater to gas.

  • @jameschuke4104
    @jameschuke41044 күн бұрын

    Fu k it iam lost

  • @jwblount7802
    @jwblount7802 Жыл бұрын

    Or you could just install the tankless that is designed to replace a tank heater which will supply the same amount of hot water as tankless water heater that you explaining without adding the cost of changing the old gas line. Just saying....

  • @fixerupperer

    @fixerupperer

    Жыл бұрын

    What? Tankless use more gas over a short period of time vs tank style heaters. Go find a tankless that only runs at 35k-50k btu and see what the temp rise and gpm are.

  • @jwblount7802

    @jwblount7802

    Жыл бұрын

    @@fixerupperer Rheem, States, and Navian to name a few that run on the existing gas line that is for replacing an existing tank water heater for a whole house set up, Especially for the size house he was describing in this video. So look around and ask they're out there and I have installed them and they work pretty well.

  • @pleasureincontempt3645
    @pleasureincontempt3645 Жыл бұрын

    Haha, your backwards C is not impressive. Clarity over style is more important.