Maraming salamat sir malaking tulong talaga sir.god blessed you always sir....more power.ingat.
@kamarino4514 Жыл бұрын
Salamat sir ,sana marami pang kagaya sayo na masipag mag share ,para din naman satin lahat yan mga pilipino para mas lalo pang magtiwala satin ang mga owners ng barko ❤
@channacion202010 ай бұрын
Thank u so much po sir galing mong mag xplain sir . Isa kang alamat😅
@hidelitosisona357011 ай бұрын
In sounding the COT of tanker, i used the standard chart T 52 and 54. for observed temperature and density. .i agree with you, density will be take from laboratory. We could not get the accurate but slight different and acceptative to international stanaded and even API 60 to Centigrate 15 there is slight different, and could not be avoided during steaming time .
@shoannessecidadeafonso3124 Жыл бұрын
at the end there is a correction.... it should be 95.7708
@ranienograles-yb8ug Жыл бұрын
Thank you very much sir very informative.
@oleksandrkyrylyuk7944 Жыл бұрын
Thanks 👍 Chief. Is this correction table is suitable for calculation FO and MDO as well???
@archiecerbito8190 Жыл бұрын
thank u Sir
@apholmanlangit889 Жыл бұрын
Salamat sir sa idea..
@TJ-bi8hf6 ай бұрын
salamat sir
@obedjohnbajan177911 ай бұрын
Good eves po sir, new subscriber po 😊
@andrewjohn6611 Жыл бұрын
Last equation should be 95.7708 instead of 94.7708 . Thanks.:)
@thiagoweberth2210
Жыл бұрын
yes... i reach to same calculation
@bosslakay6466 Жыл бұрын
Good day sir, tanong ko lang po kung saan nakukuha yung "trim". Isa po akong kadete interisland at self studying po habang ginagawa yung mga trabaho dito. Salamat po.
@kuyamigzt.v44313 ай бұрын
Sir chief yung 35degree celcius observe temp.po ba yan?
@leuacapulco86256 ай бұрын
Wla bang mas madaling computation nyan sir.
@shoannessecidadeafonso3124 Жыл бұрын
and MT=88.444 (correction at the end)
@rommelvillahermosa1763 Жыл бұрын
Good day sir, paano nakuha ang 0.00072 o coefficient of expansion? Sa computation cya?
@reneocheta9275 Жыл бұрын
Thank you sir, and i want to take this opportunity for the benefit of all, mostly for the beginners like me. My Question sir is, how or is there a way we can know in advance the density of the fuel that is going to be supplied to us. Since that fuel is yet to be loaded or bunkered onboard? 🙄🙄🙄 Is it posible that we can ask the owner/charterer to get the correct sg so we can compute how much exactly or at least close enough to the ordered quantity. Salamat po.
@user-bb6qr6hc3r
Жыл бұрын
The supplier will give you the density. During the bunkering procedure, the fuel will be sampled and afterwards will be taken to a lab to be analyzed, and compared to the density the supplier provided.
@danphilippedrajas3448 Жыл бұрын
Good eve po san po galing ang 35°C na t1.
@GR-bf2gw
Жыл бұрын
Tank Temperature
@devanshshukla6557 Жыл бұрын
Plz english
@enginejobstvtrapz4469 Жыл бұрын
Sir saan po makikita ang 35 na temperature sa loob naba ng storage tank yan?
Пікірлер: 24
Maraming salamat sir malaking tulong talaga sir.god blessed you always sir....more power.ingat.
Salamat sir ,sana marami pang kagaya sayo na masipag mag share ,para din naman satin lahat yan mga pilipino para mas lalo pang magtiwala satin ang mga owners ng barko ❤
Thank u so much po sir galing mong mag xplain sir . Isa kang alamat😅
In sounding the COT of tanker, i used the standard chart T 52 and 54. for observed temperature and density. .i agree with you, density will be take from laboratory. We could not get the accurate but slight different and acceptative to international stanaded and even API 60 to Centigrate 15 there is slight different, and could not be avoided during steaming time .
at the end there is a correction.... it should be 95.7708
Thank you very much sir very informative.
Thanks 👍 Chief. Is this correction table is suitable for calculation FO and MDO as well???
thank u Sir
Salamat sir sa idea..
salamat sir
Good eves po sir, new subscriber po 😊
Last equation should be 95.7708 instead of 94.7708 . Thanks.:)
@thiagoweberth2210
Жыл бұрын
yes... i reach to same calculation
Good day sir, tanong ko lang po kung saan nakukuha yung "trim". Isa po akong kadete interisland at self studying po habang ginagawa yung mga trabaho dito. Salamat po.
Sir chief yung 35degree celcius observe temp.po ba yan?
Wla bang mas madaling computation nyan sir.
and MT=88.444 (correction at the end)
Good day sir, paano nakuha ang 0.00072 o coefficient of expansion? Sa computation cya?
Thank you sir, and i want to take this opportunity for the benefit of all, mostly for the beginners like me. My Question sir is, how or is there a way we can know in advance the density of the fuel that is going to be supplied to us. Since that fuel is yet to be loaded or bunkered onboard? 🙄🙄🙄 Is it posible that we can ask the owner/charterer to get the correct sg so we can compute how much exactly or at least close enough to the ordered quantity. Salamat po.
@user-bb6qr6hc3r
Жыл бұрын
The supplier will give you the density. During the bunkering procedure, the fuel will be sampled and afterwards will be taken to a lab to be analyzed, and compared to the density the supplier provided.
Good eve po san po galing ang 35°C na t1.
@GR-bf2gw
Жыл бұрын
Tank Temperature
Plz english
Sir saan po makikita ang 35 na temperature sa loob naba ng storage tank yan?