How to add an outlet. Easy tasks aren’t always easy, hopefully this helps 🙏

Ойын-сауық

We missed this outlet in the rough in. Very lucky to have that range cabinet there.
I am a master electrician with 20+ years experience. Hopefully this will help someone. No 2 projects are the same but this will provide context to adding a receptacle when drywall is finished. Always be mindful of where studs are in this process, otherwise you will have to cut out finished drywall. Or worse, tile! If the original outlet had a stud on the right side(wrong side), I would have removed the box and drilled through at the top or bottom of the hole so a box could still be place back in the original hole. Hope this helps. #electrician #apprentice #diy #howto #construction #ocd #outlet #receptacle #add #new

Пікірлер: 22

  • @mavenfeliciano1710
    @mavenfeliciano17104 ай бұрын

    "I'm a professional, I'm an electrician, I'm not cleaning up." You're not lying. 😂

  • @richt5986
    @richt59864 ай бұрын

    The best way to get the length for a wire in an old workbox. Put your lymans in the box and cut at the end of the handle. That leaves you exactly 8 inches.

  • @electricianjoe

    @electricianjoe

    4 ай бұрын

    Nice tip 🫡

  • @richt5986

    @richt5986

    4 ай бұрын

    @@electricianjoe wish you were in my area. I need people I'd hire you

  • @richt5986
    @richt59864 ай бұрын

    Nice job

  • @troyarce3620
    @troyarce36204 ай бұрын

    Hey Joe can you do troubleshoot videos? I think they would be interesting and helpful for people who might not have as much experience with them

  • @kev1nacho
    @kev1nacho4 ай бұрын

    “We love u UKers” 😂. Amazing vid Joe! Thanks as always!

  • @electricianjoe

    @electricianjoe

    4 ай бұрын

    🤝

  • @MasterShiFu714
    @MasterShiFu7144 ай бұрын

    Mercia fuck yeaaaaa

  • @richt5986
    @richt59864 ай бұрын

    I take it the house is built on a slab and there is no basement, so you can bring The Wire down and back up.

  • @jackburton1467
    @jackburton14674 ай бұрын

    Use your impact on the cover plate and I’ll know you’re serious

  • @chrisf9607
    @chrisf96074 ай бұрын

    If a fridge goes in there you might want a recepticle there to

  • @richt5986

    @richt5986

    4 ай бұрын

    It's an oven

  • @chrisf9607

    @chrisf9607

    4 ай бұрын

    ​@@richt5986that makes sense also maby the j box in the corner is for oven conection

  • @richt5986

    @richt5986

    4 ай бұрын

    @@chrisf9607 100% correct sir

  • @westcoastpacoimacalifas
    @westcoastpacoimacalifas4 ай бұрын

    Didn't even keep it the same height as the other one haha dam

  • @electricianjoe

    @electricianjoe

    4 ай бұрын

    Same height would have been right under the window, “custom” is applying something that makes since to the specific application 🫡

  • @westcoastpacoimacalifas

    @westcoastpacoimacalifas

    4 ай бұрын

    ​@@electricianjoe just fuccing wit you dogg no shit same thing with that un level tiger box

  • @TheOtisUpham
    @TheOtisUpham4 ай бұрын

    Lmfao cuts a channel instead of where the studs are. I like your style. Fuck the drywallers. I never pigtail on two wires, only three. Why do you do that

  • @richt5986

    @richt5986

    4 ай бұрын

    It's better to pigtail because of anything happens to the device.You can lose power down the line..... in theory,..... I've done jobs and buildings.Where the engineer actually specified, they pigtails.They did not want you to splice through devices