How Many Ground Fault Circuit Interrupters On One Breaker

In this video I will show you how many ground fault circuit interrupters ( GFCI ) you can have on one circuit. I have been asked this question numerous times and now I feel like it shoudl be addressed. I am using 2 20 amp GFCI's in this demonstration. Any questions please feel free to shoot me a message.
***Check out my Amazon Store Where you can help support my channel and learn about other great products that I highly recommend.
www.amazon.com/shop/mountaine...
Ideal 1/2 EMT Bender amzn.to/35sUaR0
Klein Dual Strippers amzn.to/3irPZIS
Klein 1/2 EMT Bender amzn.to/2RgixcB
Klein Linesmans pliers amzn.to/3latR7K
Klein 11-1 Screwdriver amzn.to/3glMRfV
Klein Stripper Pliers amzn.to/31mViU6
Santronics Voltage Tester amzn.to/3giLoa5
Scotch 33 Electrical Tape amzn.to/32i8WHi
Milwaukee hook blade knife amzn.to/2DVxkWV
Milwaukee 11-1 Screwdriver amzn.to/2RiiBIG
Klein Mc BX cutter pliers red handle amzn.to/3irg62D
Greenlee MC splitters amzn.to/2Roe1J3
Feel Free to join my other electrical only channel link is below:
/ @sparkythewindbag7074
Cameras And Gear That I Am Using
Canon m50 amzn.to/3h1EA1H
Sigma 16mm f/1.4 amzn.to/344dzXL
Go Pro Hero 7 Black amzn.to/343QWTq
Rode Video Micro Pro amzn.to/3ay2K1E
Comica XD Boom Wireless Microphone amzn.to/3gWHbtT
Movo Wireless Micorphone amzn.to/2PTgeeO
DISCOUNT CODES FOR ITEMS IN ALL OR PREVIOUS VIDEOS:
Tryavax wallets
www.trayvax.com use code Bold10 for 10% off all orders
Industructible shoes for everyone
www.indestructibleshoes.com use code MIKEG58 for 20% off
Surviveware shower wipes
www.surviveware.com use code MNTNRO10 for 10% off
Mailing address
P.O. Box 149
Covington Va 24426
Please Feel Free To Join Me On Patreon And Joining In On The Journey My Link Is As Follows. / mountaineeroutdoors1
PayPal: paypal.me/mountaineeroutdoors

Пікірлер: 652

  • @thenite187
    @thenite1873 жыл бұрын

    Okay, this is a bit confusing because there are some tests left out of this video (like testing the plug side while power is reaching the lug side of the brown CFGI or "child receptacle"). First of all, let's assign some names to the GFCI's in question. We'll refer to the first GFCI (white/off white) as the "parent" and the second (brown), third, fourth, ect... GFCI's as the child/ren. - outlets hooked up in series (connected to the bottom lugs of the GFCI outlet). To simplify this, do not/never hook up GFCI's in series. Only connect them in parallel as if they are independent from other GFCI's on the same circuit. Voltage drop from one GFCI/GFI to another will prevent children from resetting. You only need one CGFI for child outlets ran in "Series" (using the bottom lugs on the parent GFCI to connect child outlets - being mindful of how many outlets you can run on one circuit by code). GFCI should be able to trip with a short (grounded circuit) upstream and downstream, which trips the auto-shutoff feature of the receptacle/s (all the GFCIs on the same circuit should trip). The confusing part is that nowhere in the video does it show a reset of the child (brown) GFCI after the parent was tripped (indicating a voltage drop preventing the child GFCI from resetting or it wasn't manually reset until later, which we did not see), resetting the child GFCI should correct the power-flow to the plug-side/s of the all the children receptacles. So, as elementary as the GFCI function is, as long as there is power fed through the receptacle both the parent GFCI and theoretically the series GFCI receptacles have been manually reset, the power should flow through to the plug side of the parent and child/ren GFCI's (unless there isn't enough power to the GFCI in order to reset it/them). Problem again is, there's a voltage drop that keeps child CFGI's from resetting. The point is,, you do not need multiple GFCI's as long as you connect standard outlets in series to the parent GFCI outlet using the first method demonstrated in this video. It is not recommended to use this method to series GFCI's outlets (if it happened to work at all) because when one GFCI trips, they all should respectively trip and making it difficult to isolate where a short might be occurring (which will leave you and even a professional electrician with the proverbial head-scratch wondering why someone would subject themselves or anyone to that mess). It is wiser to choose whether or not to provide direct power (wiring in parallel to each receptacle, isolating GFCIs and with or without child outlets) or simply installing one GFCI that controls all following child outlets in series (connected to the bottom lugs of the GFCI). - Do not add GFCI's in series, meaning a parent GFCI controlling GFCI/s downstream, that's just being a jerk and causing you the headache of having to reset all dependent GFCI's, if they work at all, in the event one becomes tripped. Rely on one GFCI to control multiple child outlets or provide direct power to each GFCI independently on the same circuit.

  • @MountaineerOutdoors

    @MountaineerOutdoors

    3 жыл бұрын

    Wow that's an awesome comment thank you for writing this. Have a great day ☺

  • @jban4457

    @jban4457

    3 жыл бұрын

    In order to run a "series", couldn't you just figure out the formula-for-resistance-loss for every "child" outlet, then check the specs on the gfci for the required ohms? (I'm thinking one or two "child" outlets would operate properly but that's purely a common-sense guess.)

  • @MP-zf7kg

    @MP-zf7kg

    2 жыл бұрын

    @@jban4457 Problem is the unpredictability of load.

  • @MP-zf7kg

    @MP-zf7kg

    2 жыл бұрын

    This is a great comment and far better than the video. What's really a kicker is to "map" a circuit correctly, including light fixtures.

  • @keithharrington4595

    @keithharrington4595

    2 жыл бұрын

    @@jban4457 the use of "series" and "parallel" with gfci's can be confusing. Gfci's simply check for a current imbalance and trip. We connect up 120vac to the GFCI input (line) and it protects that outlet. There are terminals (load) to allow the GFCI to essentially be the protected power source for recepticles connected down stream, giving them GFCI protection. Running power through the GFCI like that can been refered to as "series" because power runs through it, however, it passes power through like a breaker (120vac) to the parallel connected down stream recepticles. If you need GFCI protection in two spots, you can "T" tap or pigtail or parallel connect two gfci's On the (line) side to have GFCI protection and a GFCI in each location. Gfci's do not play well with one another when one feeds the other.

  • @takeniteasyfriend
    @takeniteasyfriend Жыл бұрын

    BLUF: Multiple GFCI receptacles on the same circuit must be wired electrically in parallel vs serially. Great 👍 hands on demonstration

  • @EsqChrio
    @EsqChrio Жыл бұрын

    I have an old house that has both bathroom wall outlets on the same circuit. I changed out both today with GFCI outlets and spent several hours trying to figure out why the second one would not work. Stumbled across this video and resolved the problem in a minute. Thanks for the video. It was a big help.

  • @MountaineerOutdoors

    @MountaineerOutdoors

    Жыл бұрын

    Awesome so glad that you found my video. I appreciate you watching and commenting ☺

  • @glasshalffull2930

    @glasshalffull2930

    Жыл бұрын

    You wasted time and money. A circuit only needs one GFCI and it should be on the receptacle closest to the breaker panel. The GFCI installed this way protects all outlets downstream.

  • @MountaineerOutdoors

    @MountaineerOutdoors

    Жыл бұрын

    That's great in a perfect world, most homes are not wired like they should be

  • @rw5838
    @rw5838 Жыл бұрын

    Greetings, Sir! I think I have the answer to your question as to "why" this works (correct me if I am wrong). We know that an A/C circuit is a parallel circuit. SO, in order to make the 2nd GFCI independent of the first one, we have to wire the UNgrounded Conductors "in parallel with" the TRUE source (the circuit breaker). By wiring the ungrounded conductors in parallel with the BREAKER, we allow current to flow to each receptacle at all times INDEPENDENTLY OF the upstream GFCI. I think this would be more evident into the viewers if you had used a pigtail, because it would show that the current is "dropped off" at the 1st GFCI receptacle AND it continues to the 2nd one simultaneously. This reminds me: I need to make this correction on my own house tomorrow from when I was an apprentice. Thank you for your excellent videos! If someone already commented on this, I apologize!

  • @josephcarreoniii6434
    @josephcarreoniii6434 Жыл бұрын

    I really liked your explanation. I needed this because I have to change out a regular receptacle to a a GFI on the other side of our kitchen sink. So, in other words there will be two GFI breakers on each side of the kitchen sink for safety sake. Keep up the good work!!

  • @MountaineerOutdoors

    @MountaineerOutdoors

    Жыл бұрын

    My pleasure thanks for watching and commenting ☺

  • @brettfoster6786
    @brettfoster67862 жыл бұрын

    Thanks buddy, I’m rewiring a old house and I’m keeping your videos handy. A big thumbs up 👍

  • @MountaineerOutdoors

    @MountaineerOutdoors

    2 жыл бұрын

    I appreciate it good luck. Thanks for watching and commenting ☺

  • @daniel.j.rauscher
    @daniel.j.rauscher Жыл бұрын

    Thanks for this video. I’m a DIY-er getting ready to install several receptacles around my outdoor patio, so will have several GFCIs on one circuit. Basically, looks like pigtailing them / wiring in parallel is the only way to go.

  • @MountaineerOutdoors

    @MountaineerOutdoors

    Жыл бұрын

    I agree. Or you can put in regular receps and come off the load side. All depends on what you want to spend and the look your aiming for

  • @ericsmith5104
    @ericsmith5104 Жыл бұрын

    Thank you. Home inspector said I had to put a GFCI on the outside [under porch] but no one realized it was daisy chained from the GFCI in the kitchen. Was having this very problem and this just fixed it.

  • @apackwestbound5946

    @apackwestbound5946

    Жыл бұрын

    Nice catch and discovery! May I make a suggestion that you label the outlet/receptacle that is outside and under the porch saying that it is GFI/GFCI current protected. Most GFI/GFCI have several small peel off and use labels included in the packet/box the GFI/GFCI comes in that are designed for this. All outlets/receptacles that are downstream, connected to the "load" side of the GFI/GFCI should be labeled as GFI/GFCI protected.

  • @billm.8220
    @billm.8220 Жыл бұрын

    Definitely good to know. Doubt I will ever need to put 2 GFIs on the same circuit but great knowledge to have for future reference.

  • @MountaineerOutdoors

    @MountaineerOutdoors

    Жыл бұрын

    Thanks for the comment and watching ☺

  • @denniskazich7559
    @denniskazich75592 жыл бұрын

    You are an excellent instructor. I've done this several years ago. It always worked fine so I feel confident. Although I'm going to take off the cover tomorrow and recheck it lol. It's in metal box and mounted on the block wall.

  • @MountaineerOutdoors

    @MountaineerOutdoors

    2 жыл бұрын

    I appreciate your kind words. Thanks for the comment and watching ☺

  • @dswartzinator
    @dswartzinator16 күн бұрын

    thanks for this video man! You confirmed what I was thinking.. now I'm good to go and didn't burn down my house!

  • @MountaineerOutdoors

    @MountaineerOutdoors

    14 күн бұрын

    My pleasure thanks for watching and commenting ☺

  • @bb55555555
    @bb555555557 ай бұрын

    that is absolutely correct. I found that out the hard way when I was installing these in my kitchen renovation.

  • @salfitimina2376
    @salfitimina2376 Жыл бұрын

    I've replaced many kitchen GFCIs, just using the existing wire method they used ( Line in load out) and have never had a problem. Tested all and theu all worked corr8

  • @slbreeze1
    @slbreeze1 Жыл бұрын

    Thank you thank you for this video! I had it wired right but ended up with no bathroom fans, lights or outlet juice in two bathrooms. Made no sense until I finally found this gem advice, It worked! Now if I can just get the broken bottom screw out of the box housing, it'll look nice too. :)

  • @MountaineerOutdoors

    @MountaineerOutdoors

    Жыл бұрын

    Glad to hear that this helped you ☺

  • @Mad_ghalley88
    @Mad_ghalley883 жыл бұрын

    Thanks. I am doing my own basement and I had to put 3 gfci in the kitchen counter and I was having the same issue. I did it they way u showed in this vedio it worked. Thank.

  • @MountaineerOutdoors

    @MountaineerOutdoors

    3 жыл бұрын

    Awesome thanks for watching and commenting

  • @andresmendez7800
    @andresmendez7800 Жыл бұрын

    I’m a third year apprentice and even this video made more sense then some of these electricians on this job site !! Thanks 🤙

  • @MountaineerOutdoors

    @MountaineerOutdoors

    Жыл бұрын

    Awesome glad to hear that this helped you. Sometimes people tend to over complicate things. Have a great day ☺

  • @LuminusMarley
    @LuminusMarley Жыл бұрын

    I can’t express my gratitude enough! This was driving me crazy…I have one gfci line running to 2 bathrooms and I couldn’t get the new outlets to work in the second bathroom! Problem solved! 😅🙏

  • @MountaineerOutdoors

    @MountaineerOutdoors

    Жыл бұрын

    Awesome!! Glad that this helped you. Have a great day ☺

  • @ktm42080
    @ktm42080 Жыл бұрын

    Great video! I'm currently rewiring my kitchen, gonna have (I know, I know) 3 GFIs on a 20 amp circuit. There will be no other load on that circuit, just multiple outlet options, house was built before electricity. Two will be joined in a junction box and the third will tail off the last GFI, now I know how to do it without getting confused. Thanks!

  • @MountaineerOutdoors

    @MountaineerOutdoors

    Жыл бұрын

    Nothing wrong with that many gfcis it's all preference. I appreciate you watching and commenting ☺

  • @charlesbernius8065
    @charlesbernius80652 жыл бұрын

    Good video Brother. Just retired out of IBEW Local 130. I can’t explain it either but you are correct, it doesn’t work if you use the load side to feed another GFCI.

  • @MountaineerOutdoors

    @MountaineerOutdoors

    2 жыл бұрын

    Amen and congratulations on your retirement.. I can't wait

  • @justwrenchit9287
    @justwrenchit92872 күн бұрын

    Omg thank you! Redoing a circuit and thought I was going crazy! Now I know, you are awesome

  • @richardbatters
    @richardbatters2 жыл бұрын

    Thank you for this. It makes perfect sense if you understand LINE & LOAD. But I understand the confusion.

  • @MountaineerOutdoors

    @MountaineerOutdoors

    2 жыл бұрын

    My pleasure thanks for watching and commenting ☺

  • @darrenwarren8636
    @darrenwarren86366 ай бұрын

    Thank - you, solved a problem that has been driving me crazy for months

  • @Kilrbbbs
    @Kilrbbbs2 жыл бұрын

    After scratch my head for an hour and wiring it the wrong way, I watch your video and problem solved. Thank you for the mock up walk through.

  • @MountaineerOutdoors

    @MountaineerOutdoors

    2 жыл бұрын

    So glad to hear this thanks for watching and commenting.

  • @actionjksn

    @actionjksn

    2 жыл бұрын

    Why did you put multiple GFCIs on a single circuit?

  • @Kilrbbbs

    @Kilrbbbs

    2 жыл бұрын

    @@actionjksn no particular safety reason. I just bought two…..Legrand radiant Night Light, Self-Test GFCI Outlets, Safe for Kids, Tamper Resistant, Brushed Nickel, 15 Amp, 1597NTLTRNICC4 on Amazon because I like the metal look. Afterwards I needed this video to figure out how to wire one GFI to another.

  • @philly444fan3
    @philly444fan3 Жыл бұрын

    I like your video/s and I know you're trying to help people. Let me also say that I'm not disagreeing with you, esp since I've seen your theory of wiring multiple GFCIs on 1 circuit used on other websites/searches. Only problem I have (which might be where a lot of people get confused) is if you look at the instructions that come in the box of a new GFCI, there's a diagram showing the correct way (or the manufacturers suggested way) to wire multiple GCFIs to 1 circuit is to take feed wires from breaker (panel) to line side of 1st GFCI, connect load (branch circuit/downstream) wires to load side of 1st GFCI, then connect those wires to line side of 2nd GFCI and repeat that process for however many GFCIs you are installing on that circuit. In other words go line to load, line to load, line to load etc. I have pictures of instructions from a brand new Eaton GFCI that illustrate this, however I can't add photos to this comment (or at least I can't figure out how to add the photos). Not sure where this leaves us, but I wanted to point out what the manufacturer (in my case Easton) suggests as to the correct way to wire multiple GFCIs on 1 circuit.

  • @MountaineerOutdoors

    @MountaineerOutdoors

    Жыл бұрын

    Yep. Nothing wrong with I always say follow the manufacturer diagram. That just keeps it alot more simple for some. Great comment. Have a great day ☺

  • @rickl6697
    @rickl6697 Жыл бұрын

    The reason I want to do this is, I have two sump pumps in my yard that I want to run off of one 20 amp circuit with a regular breaker. I want the sump pumps independent of each other so if one trips their GFCI outlet it won't shut down the other sump pump when there is no problem with that pump. Thanks for posting this and explaining. I'll be wiring them so they are in parallel with each having their own ground, neutral and hot.

  • @MountaineerOutdoors

    @MountaineerOutdoors

    Жыл бұрын

    Good luck and thanks for watching and commenting ☺

  • @earthenergyhex
    @earthenergyhex3 жыл бұрын

    thanks for this, I was connecting 2 sheds so I have 2 GFI's and it wouldn't work. now I know why, I'm gonna go fix it.

  • @MountaineerOutdoors

    @MountaineerOutdoors

    3 жыл бұрын

    Excellent thanks for watching and commenting ☺

  • @joseluisruiz3789
    @joseluisruiz37893 жыл бұрын

    Your video was very helpful thank you so much for taking the time to make it. I have regular 15 Amp outlets in my basement with a 20 Amp Circuit breaker and want to switch them to(WR) Weather Resistant 20 Amp GFCI Outlets and found this very helpful. I rent the house I live in "built in 1920" and all the Outlets where old and most of them we lose from the plug area and when I replaced them I noticed all of them were 15 amps. When I checked the circuit breaker box outside the house I seen that all the breakers are 20 amps using 12 Gauge Copper wiring except the Air Conditioning Breakers, those were 2 x 50 Amp Outlets and the main power breaker that shuts everything down is 2 x 100 Amp Breakers. I will definitely buy these off your affiliated link. It's the least I can do to support the channel. Thanks again for help me as a DWYER, my landlords don't fix anything so I do all the work my self. 🙏🙇‍♂️

  • @MountaineerOutdoors

    @MountaineerOutdoors

    3 жыл бұрын

    That sucks about your landlord. I appreciate you watching and commenting and supporting my channel. I hope everything gets fixed for you. Take care and good luck

  • @keithharrington4595

    @keithharrington4595

    2 жыл бұрын

    Read those instruction for those gfci's carefully. They do not play well together when one feeds another. You can have one GFCI feed several or use pigtails to attach power to the "line side".

  • @surferdude642

    @surferdude642

    2 жыл бұрын

    It's totally acceptable to use 15 amp duplex receptacles or gfci's on a 20 amp circuit. You shouldn't use 20 amp receptacles on a 15 amp circuit.

  • @marklashway
    @marklashway Жыл бұрын

    Wow we have this problem at our marina for about five boats. I’m going to look into this thank you very much.

  • @MountaineerOutdoors

    @MountaineerOutdoors

    Жыл бұрын

    My pleasure thanks for watching and commenting ☺

  • @georgeryan9139
    @georgeryan91392 жыл бұрын

    Run a few regular outlets from your one gfi. Note, the gfi is the first outlet on the circuit, use them in bathroom, kitchen, basement, garage and out door outlets or use ark and combo circuit breakers (new code).

  • @MountaineerOutdoors

    @MountaineerOutdoors

    2 жыл бұрын

    Yep exactly thanks for watching and commenting ☺

  • @r4ptorbunny593
    @r4ptorbunny59310 ай бұрын

    The previous owner of my house wired up multiple GFCI outlets in series/chains in this house. I think the reason mine work and yours didn't is because mine are ungrounded. It's always fun when the 3rd or 4th receptacle doesn't have power and I have to check every one from the panel to the problem outlet to see which one tripped.

  • @gregrichard9192
    @gregrichard91922 жыл бұрын

    I've learned something watching this video. Great job

  • @MountaineerOutdoors

    @MountaineerOutdoors

    2 жыл бұрын

    Thank you I appreciate it alot and glad to hear that you learned from this. Have a great day ☺

  • @sammysleeves33
    @sammysleeves333 жыл бұрын

    My one bathroom doesn't have an outlet. I was thinking about maybe putting one in, wiring it to the GFCI on the adjacent wall in another bathroom. Now I know how! 😁

  • @MountaineerOutdoors

    @MountaineerOutdoors

    3 жыл бұрын

    Awesome glad to hear that this helped you. Good luck 🤞

  • @RicardoHernandez-fv5bv
    @RicardoHernandez-fv5bv2 жыл бұрын

    Old this helped a lot I was stuck and this saved my brain from crashing

  • @MountaineerOutdoors

    @MountaineerOutdoors

    2 жыл бұрын

    Awesome glad to hear that this helped you out. Thanks for watching and commenting ☺

  • @futuregamer5791
    @futuregamer57913 жыл бұрын

    Or you can wire the neutrals together and the hots. Then pig tail off of them to the first gfci

  • @castawaysmc
    @castawaysmc Жыл бұрын

    well I'm glad I accidentally run across this video. I recently made a few pigtail GFCI boxes to use on my string of drop cords on the job site so that I don't have to deal with running all the way back to the house. also many customers don't have a GFCI outlet outside their house so when it trips I have no power until I catch them at home in the evening. it really sucks when they are out of town. Anyway, I did it the wrong way and kept running back and forth chasing tripped outlets forever. I couldn't understand what was happening. THANKS

  • @MountaineerOutdoors

    @MountaineerOutdoors

    Жыл бұрын

    Awesome and it's my pleasure. I appreciate you watching and commenting ☺

  • @JDRedNation
    @JDRedNation2 жыл бұрын

    Dropping by to say this video helped me tremendously! Thanks

  • @MountaineerOutdoors

    @MountaineerOutdoors

    2 жыл бұрын

    That's awesome so glad that this helped you ☺

  • @CK-gd6mz
    @CK-gd6mz2 жыл бұрын

    I experienced the exact same issue and I was completely stumped. I took everything apart and double checked everything again. Same exact issue. I used a screwdriver and depressed the reset on both GFCI until I heard a loud "CLICK". The first way, the wrong way actually works. You just need to reset both GFCI.

  • @actionjksn

    @actionjksn

    2 жыл бұрын

    You're not supposed to put multiple GFCIs on one circuit, you put one single GFCI on the first one in the series and then it will protect all of the other outlets. That is nothing but a big waste of money putting multiples on one circuit.

  • @tomhanwayescape

    @tomhanwayescape

    2 жыл бұрын

    with the "wrong" way, if the parent one trips so will the second or third etc. I have a parent GFCI in a bathroom inside a rental studio and three other receptacles downstream off that GFCI. So if it trips in the rental bathroom all the other ones go to. The other ones are in a second studio or outside plugs. If the parent one trips, my second rental has no power in the kitchen and I have to get permission from the renter to go inside and fix it, which can take hours. So I am changing the wiring on the parent receptacle the "right" way, so each GFCI is independent from the others. hope that makes sense. '

  • @tomhanwayescape

    @tomhanwayescape

    2 жыл бұрын

    @@actionjksn unless you want them to work indepently, like if one is in unit and another is in a second unit

  • @MountaineerOutdoors

    @MountaineerOutdoors

    2 жыл бұрын

    It does good luck and it will help out alot

  • @adrianfrancis1156
    @adrianfrancis11563 жыл бұрын

    Very Good teaching Sir. Someone plz comment by informing what is that terminology. With why you cant put a GFCI from line to load feeding a next GFCI outlet. If someone knows watching this video plz comment and don't be mind with that knowledge.

  • @curtisruth7906
    @curtisruth790628 күн бұрын

    It’s called using the line to line and the reason why the other way will not work is because basically that is a breaker and a socket form and when the breaker trips, it breaks the connection which means if you have another circuit or another circuit, but if you have another plug down the line that’s wired on the load Side that is what is tripping so naturally it’s not going to work

  • @danchandler9381
    @danchandler9381 Жыл бұрын

    Some hair dryers have a GFCI built into the cord. WHen I plug a hair dryer like that into a wall-mounted GFCI, it works fine. This means (at least in this case) that there is no problem with putting GFCIs in series. Is there something unique about the case I describe here that allows GFCIs to be wired in series?

  • @johnc7883
    @johnc78838 ай бұрын

    Have a outdoor lamp post, front porch and back deck that I want on the same circuit. The all in one outdoor in use covers from the big box store already come with the GFCI so I am using both. soooooo. Outside lamp post runs to front porch GFCI and gets connected to load. The front porch and back deck both go to line yea? I know its dumb but its a visual thing for a future homeowner to see the GFCI versus guessing

  • @oscarsanta7986
    @oscarsanta79863 жыл бұрын

    Excelente información muchas gracias 👍

  • @MountaineerOutdoors

    @MountaineerOutdoors

    3 жыл бұрын

    My pleasure thanks for watching and commenting ☺

  • @tonymendes6743
    @tonymendes67434 ай бұрын

    Thanks. Great video. How close can you install a GFCI PLUG to a shower or a sink in the bathroom.

  • @MountaineerOutdoors

    @MountaineerOutdoors

    3 ай бұрын

    ?

  • @martingonzalez529
    @martingonzalez5293 жыл бұрын

    Excellent information, well done 👍👍👍👍

  • @MountaineerOutdoors

    @MountaineerOutdoors

    3 жыл бұрын

    Thanks ☺

  • @MissyRichmond-vm5rf
    @MissyRichmond-vm5rf3 ай бұрын

    I’m brand new at all this but I’m eager and want to be great at it thank u for your video ! My question is when putting a gfci in what can u do wrong that your other outlets won’t be protected

  • @MountaineerOutdoors

    @MountaineerOutdoors

    3 ай бұрын

    Wiring them only on the line side will not protect the downstream ones

  • @troops9986
    @troops99862 жыл бұрын

    Nice video man. Takes some courage to put one's livelihood out there for a zillion other arm chair electricians to pick apart. Well done. Just a thought, not a critique... it would have been beneficial, I think, to show a "test/reset" cycle of the secondary outlet. Gfi outlet replacement, although relatively standard fare for a working electrician, can be trickier than people give it credit for. A simple, yet very worthy topic.

  • @MountaineerOutdoors

    @MountaineerOutdoors

    2 жыл бұрын

    I appreciate your comment and watching. I agree with you on this whole comment. I have had some pretty interesting talks with so called electricians who try to throw code at me and telling me that I am wrong. Some people just are always negative and see miserable in life. Once again thank you for your comment and watching ☺

  • @jonathancall9967
    @jonathancall99672 жыл бұрын

    I did the same thing with an exterior outlet on our fifth wheel, and I have a GFCI outlet on the outside of our fifth wheel that is connected to the load side of our GFCI in our fifth wheel's bathroom and it works!

  • @gregriley649
    @gregriley6493 жыл бұрын

    Awesome video thanks for sharing 👍

  • @MountaineerOutdoors

    @MountaineerOutdoors

    3 жыл бұрын

    My pleasure.. ☺

  • @LisaJensen
    @LisaJensen Жыл бұрын

    We are adding an outdoor GFCI outlet off a line in the kitchen that already has 1 GFCI outlet protecting 3 standard outlets. How do you connect/wire a new GFCI outlet to a reg outlet? The line-load method is causing the new one to trip immediately. Thank you for the education!

  • @MountaineerOutdoors

    @MountaineerOutdoors

    Жыл бұрын

    kzread.info/dash/bejne/eJltytl-aMe0j84.html this may help

  • @AdanValue
    @AdanValue Жыл бұрын

    I am a 2yr apprentice and recently ran into an issue. A main line from the Box was brought into a GFCI line/load (#1) in a bathroom, hopped over to another GCFI (#2) line/load, up to a light fixture, then over to a single pole switch. Best recommendations of fixing this issue??

  • @tedlahm5740
    @tedlahm57403 жыл бұрын

    Wonderful instruction. I plug my Hair Dryer (with a self contained GFCI in the cord) into a GFCI circuit. Will try tripping out the wall mounted GFCI to see what happens. Thank you.

  • @wizard3z868

    @wizard3z868

    2 жыл бұрын

    Ya been my experience 2 gfci don't like working together but maybe modern ones have worked that out

  • @carlodonnell146
    @carlodonnell146 Жыл бұрын

    you can install a regular outlet where the second GFCI is, the way you have now, you just can't install a second GFCI through the load terminals, but I think you can pigtail the hot line into the first GFCI, if you want to put a second GFCI.. Does that all make sense?

  • @jacenas
    @jacenas Жыл бұрын

    Lol, I have been going at it for 2 days on an outdoor project, powering an outdoor kitchen and outlet in the garden which we think should be gfi. This vid will allow me to redeem myself

  • @MountaineerOutdoors

    @MountaineerOutdoors

    Жыл бұрын

    Definitely outdoors gfci.

  • @danielharms5776
    @danielharms57762 жыл бұрын

    I Want to thank you for your outstanding video instructions on your explanation on circuity! Ive watched many videos on circuity and your instructions helped me understand it and complete my wiring correctly! Thank you very Much!

  • @MountaineerOutdoors

    @MountaineerOutdoors

    2 жыл бұрын

    So glad to hear that. I appreciate you watching and commenting and making these videos is definitely my pleasure. Have a great day ☺

  • @chopnchannel
    @chopnchannel2 жыл бұрын

    You’re a life saver! Thank you

  • @MountaineerOutdoors

    @MountaineerOutdoors

    2 жыл бұрын

    My pleasure thanks for watching and commenting ☺

  • @VideoByPatrick
    @VideoByPatrick Жыл бұрын

    Question: what if the breaker pan has gfi breaker, does that mean all same leg molex wires stay on line lugs and never load lugs ? Many thanks for your video. When should you use the load lugs of gfi outlets ?

  • @MountaineerOutdoors

    @MountaineerOutdoors

    Жыл бұрын

    If you have gfci breakers. You won't need gfcis at the receptacle boxes. The only times that you use load is when you are trying to make another recep that is non gfci make it protected by the gfci

  • @JuanCastillo-zm2wq
    @JuanCastillo-zm2wq2 жыл бұрын

    You just solved my problem. Thank you so much

  • @MountaineerOutdoors

    @MountaineerOutdoors

    2 жыл бұрын

    My pleasure glad to hear that this helped you.

  • @bryanburt1
    @bryanburt12 жыл бұрын

    Awesome video..Great job Mountaineer Outdoors

  • @MountaineerOutdoors

    @MountaineerOutdoors

    2 жыл бұрын

    Thanks I appreciate it ☺

  • @larryprice6321
    @larryprice63216 ай бұрын

    Thanks I really needed this for my job I'm on

  • @MountaineerOutdoors

    @MountaineerOutdoors

    6 ай бұрын

    So glad that this helped you ☺

  • @rafa031993
    @rafa0319933 жыл бұрын

    You're the best thank for your good explanation

  • @MountaineerOutdoors

    @MountaineerOutdoors

    3 жыл бұрын

    My pleasure thanks for watching and commenting ☺

  • @kevinmccaffrey7092
    @kevinmccaffrey70923 жыл бұрын

    I just built a bar, I have 3 outlets next to the sink they are all gfci because they are with in 4’ of water I have 3 gfci in a row they all work just reset them all and they are all protected

  • @ebo2584
    @ebo2584 Жыл бұрын

    Excellent explanation very clear thank you 👍

  • @MountaineerOutdoors

    @MountaineerOutdoors

    Жыл бұрын

    My pleasure thanks for watching and commenting ☺

  • @227giorgio
    @227giorgio Жыл бұрын

    I wanted it for my trailor running a space heater. Gfci goes to 6 outlets on a 15 Amp breaker. But half way through I wanted to add another gfci so the Heater only trips the last 3 that I don't care about and not all of them. This didn't help for my answer much

  • @frankrhodes5689
    @frankrhodes56893 жыл бұрын

    Solved my issue also. Thanks for this :)

  • @MountaineerOutdoors

    @MountaineerOutdoors

    3 жыл бұрын

    My pleasure thanks for watching and commenting ☺

  • @Steven1Cicero
    @Steven1Cicero4 ай бұрын

    I have a situation where I have 14 dock slips divided into 2 GFCI Breakers, ,However the GFCI breaker is located about 100 feet from the docks and every time someone leaves an extension cord plugged in and there is any moisture in the air the GFCI breaker trips leaving at least half of the dock without electric. I was wondering if I could replace the GFCI breakers with a normal breaker and wire in separate GFCI outlets so that only the person that is causing the problem would be without electric until they reset their GFCI outlet. This explained how this can be done .

  • @ronaldvazquez4373
    @ronaldvazquez4373 Жыл бұрын

    What would happen if you trip and reset the black GFCI? The magic is the electronic of the black one?

  • @CT9905.
    @CT9905. Жыл бұрын

    I wired my GFCI’s the Wrong way and now I know how to correct the problem.

  • @dabananaman1550
    @dabananaman15502 жыл бұрын

    This is great info, but what about if it's an old house and there's no ground on any outlet? Would I still put the downstream gfci on the line of the upstream gfci? I already have 3 gfci outlets in the wrong way but as soon as I put the 4th one on it trips and I cant find the issue afterwards?

  • @davidroddini1512

    @davidroddini1512

    Жыл бұрын

    Yes. If you are using GFCI outlets because the house has no ground on any outlet and are using the GFCI for safety due to lack of ground, you have to make sure to use the second method where all wires are hooked on the line side. If you only want one set of wires going to each outlet then pigtail the incoming wire, the outgoing wire and a third wire that will connect to the outlet.

  • @MarcosElMalo2
    @MarcosElMalo22 жыл бұрын

    Thank you! This is a good explanation and tutorial. This is long and about crazy electrical work in Mexico. Read on if you want to laugh and be frightened at the same time. I’m a gringo living in an apartment in Mexico. I don’t even know where to begin! In the U.S., where we have codes and shit, I was able to troubleshoot and repair electrical issues, confident that there was a basic logic based on county and national building codes. I was even able to add new circuits/circuit breakers when I needed a separate circuit for the computer room or when I set up a 220 circuit for welding. The building is between 15 and 20 years old, built by my landlord and one of his sons. I’ve been living here for nearly 10 years. It’s 2Br/1 bath/kitchen/living room, and a rooftop patio. The building is 2 second floor apartments and one commercial space on the first floor. I believe that the landlord and the son did the electrical themselves or didn’t hire a competent electrician. Also, as is common, the electrical service is split between the two apartments-meaning that each apartment gets one of the phases at our meters. My neighbor gets 120v of one hot leg, and I get the other 120. There is a single 30 amp breaker at my service panel!! All the outlets and overhead lighting are fed from a single 30 amp breaker! The house is brick construction and the wiring is buried in the walls. I’m not entirely sure if everything is wired in series or if it’s branched. If branched, the first splice is buried somewhere in the walls. Am I making sense? Also, there was no ground. One of the first things I did was to drill a hole in the foundation and hammer a 4’ copper pole into the ground. (My service panel is by the front door on the first floor.) This is so I could add two new grounded outlets to the living room for the TV and computer. I added new wire (romex 12 gauge) from the breaker-basically another splice, but at the breaker/service panel. Yeah, I know, not kosher! In the U.S., I would have added a new breaker at the panel. Here, there is no room for a second breaker on the panel. I guess at some point I might upgrade the panel or even upgrade the service to 100 amps. I hesitate because this is a rental, but I’ve been here 10 years. I’m doing a kitchen remodel and I want to replace the the outlet by the sink with a GFCI. The grounding issue is complicated. Here’s what I’ve done: the water pipes were not grounded as they’re fed from a big water tank on the roof. I’ve run a ground wire from the copper grounding pole to the water pipes. Under the kitchen sink I’ve attached a ground wire. It’s currently attached to the previous outlet (the wire is surface mounted in a plastic cable channel). I plan to add more outlets upstream. I know full well that what Im doing would not be allowed by the NEC in the U.S. I’m just trying to make my apartment safer, without going to the expense of completely redoing the electrical. Maybe I should move, but $186/month is strong motivation to stay. The plan is to do a little bit to improve the situation each month. Oh, and I haven’t even mentioned the situation with the back bedroom. It shouldn’t be too hard to solve when I get around to it: there is a open neutral somewhere. I just use the room for storage anyway. One ceiling light and one outlet function properly. But I also dread opening a can of worms and discovering the problem is more complicated than I hoped. Anyway, that’s my ongoing crazy Mexican wiring story. Also, I think this experience has cured me of my libertarian tendencies.

  • @MountaineerOutdoors

    @MountaineerOutdoors

    2 жыл бұрын

    Wow that is alot of problems. Good for you though to try to make it safer. I understand that rent is super low. I have only in my whole electrical career seen first hand one service that was 120volts. I have heard about it before but to actually see it was something else. If you keep upgrading I'd tell him to make sure he takes it off the rent. Good luck 🤞

  • @busterhikney6936

    @busterhikney6936

    2 жыл бұрын

    Wait till you see conduit made from garden hose

  • @a..d5518

    @a..d5518

    2 жыл бұрын

    @@busterhikney6936 Wait, that's not legal/smart/safe?? 🤣

  • @abrahamrodriguez4029
    @abrahamrodriguez4029 Жыл бұрын

    Hey thanks for the vid it did help!! I have a question idk if you or anybody here could help. I'm remodeling my house and had to rewire the whole thing, now I connected the electrical box and everytime I turn a breaker on it doesn't trip it but cuts power off I've been troubleshooting it but I can't seem to find the solution. I have a tester with me and power is on at the poles, all the breakers are off. As soon as I turn any breaker on the power to the the box shuts off. When I turn the breakers off the power at the poles turn back on

  • @MountaineerOutdoors

    @MountaineerOutdoors

    Жыл бұрын

    Do you have it hooked up right? I would have to see a picture of your box

  • @kevindick7485
    @kevindick7485 Жыл бұрын

    Thanks . When doing the hots would you use a Wago connector instead of a wire nut ?

  • @MountaineerOutdoors

    @MountaineerOutdoors

    Жыл бұрын

    I absolutely do not like wagos in the least. I have seen them fail. That's just my opinion. Can't ever go wrong with twisting your wires and an old fashioned wire nut.

  • @fredschultz8267
    @fredschultz82673 күн бұрын

    I always use the stab in the back connections, comments that lead individuals to think using the stab in the back (manufacture design) is wrong/dangerous is simply comical. Otherwise, I enjoyed the video.

  • @brentyoungmann2732
    @brentyoungmann2732 Жыл бұрын

    I have a ground fault plug that has a green light on one side and has a red light on the side which is red and is blinks intermittently. Seems to be working without any problems just do not understand about the blinking red light?

  • @morokeiboethia6749
    @morokeiboethia6749 Жыл бұрын

    Does that same thing happen when you wire other AFCI outlets downstream/Load from an existing AFCI outlet? I saw a vid that this home inspector did about this same topic and in the example he had 4 GFCI outlets wired downstream from the load terminal of the first GFCI outlet on the circuit. To get all of them back online you have to reset them in the order they are beginning with the first GFCI from the breaker.

  • @MountaineerOutdoors

    @MountaineerOutdoors

    Жыл бұрын

    Great question. I will be completely honest with you. I have never ever installed a arc fault receptacle ever so I cannot answer this correctly.

  • @kandiecandelaria3134
    @kandiecandelaria31342 жыл бұрын

    Ok so I want to tap into an existing GFCI to a new one for a small above ground pool motor ( 11 amps) Going to use a 20 amp gfci. Going to put both grounds connected with a ground connector,neutrals (white) into silver holes. Hot (black) into bronze colored hole on other side. Going to the new gfci ground to ground hole, white ( silver hole) black to hot side on top? Or does it go to bottom load?

  • @MountaineerOutdoors

    @MountaineerOutdoors

    2 жыл бұрын

    If you are adding another gfci for a total of 2 then come off of the line side.

  • @michaelvaughan3929
    @michaelvaughan3929 Жыл бұрын

    I thought you could have all your receptacles GFCI, but the power in is connected to the line side of each of them. I don't like having "hidden" GFCIs where a bunch of circuits are connected to the load side of a GFCI, but it's not obvious when that GFCI trips.

  • @GuitarsCarsandBikes
    @GuitarsCarsandBikes4 ай бұрын

    Good video , even with basic electrical knowledge it makes no sense why they can’t daisy chain power. But now I’m a believer.

  • @abel2santiago
    @abel2santiago4 ай бұрын

    So ilustrative. Thankyou so much!!!🎉🎉

  • @MountaineerOutdoors

    @MountaineerOutdoors

    4 ай бұрын

    My pleasure thanks for watching and commenting ☺

  • @Troy-McClure81
    @Troy-McClure81 Жыл бұрын

    Lol my House 1989 Build is so poorly wired the only 2 Gfci in my 2 story home is one in garage and one in kitchen..the kitchen was 15A on 20a circuit and wasn't even working,builder did it all backstabbed every outlet and switch,ground wires plastered instead of connected, i pray it doesn't burn down till we have the money for a pro to run through the whole system.Great explaining on wiring .

  • @MountaineerOutdoors

    @MountaineerOutdoors

    Жыл бұрын

    Yea I would definitely get this looked into as soon as you can. Good luck and thanks for watching and commenting ☺

  • @Troy-McClure81

    @Troy-McClure81

    Жыл бұрын

    @@MountaineerOutdoors Ya its matter of what the tax return will cover this year,just to change the 7 outlets in my kitchen had to turn off 5 breakers lol

  • @MountaineerOutdoors

    @MountaineerOutdoors

    Жыл бұрын

    Wow that's weird

  • @Troy-McClure81

    @Troy-McClure81

    Жыл бұрын

    @@MountaineerOutdoors ya one outlet on a wall was tied into the living room breaker,one outlet the one the big lights plug into the ceiling was another,the fridge stove and 2 outlet next to stove another,the Gfci another,and of course Dishwasher and disposal on a dedicated 20amp lol To turn off the one outlet in my backyard and the 4 in garage I have to turn off a breaker marked Gfi ,which also my low voltage is tied into I.E. my house number and doorbell lol

  • @MountaineerOutdoors

    @MountaineerOutdoors

    Жыл бұрын

    I c that makes sense now.

  • @williamspence3511
    @williamspence35112 жыл бұрын

    I have a room with - ground in the plugs and non work, but the over head lighting?

  • @AquaLew
    @AquaLew7 ай бұрын

    I have 4 outlets the first two are gfci then two regular outlets. The final two stop working... how should I go about fixing this issue?

  • @AJDIYNetwork
    @AJDIYNetwork2 жыл бұрын

    Subscribed. Great vid dude!

  • @MountaineerOutdoors

    @MountaineerOutdoors

    2 жыл бұрын

    I appreciate it and welcome to the mountaineer outdoors family

  • @eddierome4016
    @eddierome40162 жыл бұрын

    Hi friend, thanks for this video but I have a question, I did the wrong way like you show in the video but I still have power on both gfci. I want to show you how I have everything connected. From the breaker I have the 1st gfci, then 2nd gfci then three regular outlets. On one of those regular outlets , my refrigerator is plugged. Every gfci and regular outlets have power but this is the problem- after 3to 4 hours the first gfci triggers and shut down all please can you help me with this problem? Thanks

  • @MountaineerOutdoors

    @MountaineerOutdoors

    2 жыл бұрын

    First of all how do you have the gfcis wired? Then we can try to go on from here

  • @tycoonz0619
    @tycoonz06192 жыл бұрын

    Nice video, really helpful

  • @MountaineerOutdoors

    @MountaineerOutdoors

    2 жыл бұрын

    I appreciate your comment and watching ☺

  • @llchips7
    @llchips7Ай бұрын

    Thanks. This was very helpful. Exactly what I needed

  • @joev467
    @joev467 Жыл бұрын

    Good video! Nice job!...Series circuit versus Parallel circuit

  • @MountaineerOutdoors

    @MountaineerOutdoors

    Жыл бұрын

    I appreciate it, I'm assuming when you say series versus parallel you would like to see a video on it?

  • @nadajoey1
    @nadajoey19 ай бұрын

    Great video. Very helpful.

  • @Hunter__14
    @Hunter__14 Жыл бұрын

    Sweet video, question for ya, im ginna wire up my shed and was planning on one GFCI from the panel 3 regular recepts and the end of line being a recept located outside the shed, and was gonna put a GFCI on that, question is, would i hook it up like u just showed ? Bit confused . Will the recpts after the first GFCI be protected? If wired up this way? Thanks in advance....

  • @MountaineerOutdoors

    @MountaineerOutdoors

    Жыл бұрын

    Only if you out the downstream on load side.

  • @jonhansen4745

    @jonhansen4745

    Жыл бұрын

    If the 3 regular receptacles are wired to the load side of the GFCI, they are protected. If that's the case, you can then wire the outside receptacle out of any one of the 3 regular outlets or the load side of the GFCI & it will also be protected. I try to never place a GFCI receptacle outdoors. I always try to use a standard receptacle outside which is wired from a GFCI outlet or GFI protected outlet which is inside. You very seldom get a tripped receptacle outside that way. I also NEVER wire in series through a receptacle unless it's a GFCI. I always wire from pigtails.

  • @christopher9826
    @christopher98263 жыл бұрын

    Can I put a gfci and a regular receptacle in a 2 gang box with cover and add another same config down stream around my front porch will all be out in the weather

  • @MountaineerOutdoors

    @MountaineerOutdoors

    3 жыл бұрын

    Yes just make sure that both of the receps are protected and working.

  • @mothertaracey2510
    @mothertaracey25104 ай бұрын

    Good question. My house is 1986 built. there is a GFI inthe bathroom and I am adding an outdoor outlet & coode says I need a GFI. What a headache

  • @MountaineerOutdoors

    @MountaineerOutdoors

    4 ай бұрын

    Definitely for safety purposes

  • @elias2024
    @elias20242 жыл бұрын

    Thank you, it is helpful!

  • @MountaineerOutdoors

    @MountaineerOutdoors

    2 жыл бұрын

    My pleasure thanks for watching and commenting ☺

  • @Renassainceman
    @Renassainceman Жыл бұрын

    I recently replaced several GFCI receptacles for a friend and found three GFCI's wired just as you described. Since all three were on the backsplash behind the sink, I questioned why they would not just used two regular receptacles wired through the load side of a single GFCI. I assume the only reason would be if one trips the others may still stay 'alive'. Is there any other reason I'm not seeing?

  • @MountaineerOutdoors

    @MountaineerOutdoors

    Жыл бұрын

    That's probably exactly why. Alot of people like to have it match so that may be why they did it. I appreciate you watching and commenting ☺

  • @c182SkylaneRG
    @c182SkylaneRG2 жыл бұрын

    I've got a different, but related, question: I extended an outdoor outlet circuit underground to power a shed. I put a GFCI Circuit Breaker onto the circuit rather than dealing with changing the outlet cover to accept a GFCI outlet from the existing standard outlet, but as soon as I got the underground wire hooked up (18 ft from house to shed, plus another 10 or so ft along the house and inside to the panel), the breaker inside would immediately trip, regardless of how perfect I made the wiring. When I replaced it with a standard breaker, now it works perfectly. Any idea what's going on? Why a GFCI breaker keeps tripping on an underground wire?

  • @MountaineerOutdoors

    @MountaineerOutdoors

    2 жыл бұрын

    Is your conduit full of water? Is your nuetrals touching your ground wires? Is your gfci breaker hooked u correctly? Nuetral from circuit on breakers not the nuetral bar?

  • @c182SkylaneRG

    @c182SkylaneRG

    2 жыл бұрын

    @@MountaineerOutdoors I bought liquid tight flexible non-metallic conduit which is one single piece from junction box on the side of the house to junction box inside of the shed (it goes in through the shed floor to prevent water ingress). I used direct-burial rated 12-gage romex (solid plastic all the way through instead of paper) which also makes a non-stop run from junction box to junction box at each end. I can't say for 100% certain that there's no water in the line, because I laid the line a day or two before I ran the wire through it, but I did make sure the openings were pointed down, or otherwise sheltered inside the shed. I know the junction box doesn't get rained on because my eaves are 22" not including the gutters on a 1-story house, and the box is 3 ft above grade. As for the circuit breaker, itself, it was definitely wired correctly because it predates the underground extension by a year or two with no issues.

  • @thomasreedy4751
    @thomasreedy47512 ай бұрын

    Did you try to reset both GCFI outlets when connected in serial? Another KZreadr showed it is possible to have multiple GCFIs connected but highly confusing because the user has to figure out where the fault originated and reset all subsequent connections. Thus not code.

  • @cjbarlow61
    @cjbarlow614 ай бұрын

    Customer has a prefab greenhouse with a gfci. The whole thing plugs into another gfci on a stand alone breaker. When the greenhouse is plugged into the other gfci, the gfci on the breaker stops working.

  • @waynejones8548
    @waynejones854810 ай бұрын

    I am going to replace 3 GFI outlets in my primary bathroom, mainly because they are 20 years old. 2 outlets have reset buttons, but one doesn’t. The outlet that doesn’t have a reset button does have a GFCI sticker on it. So, I guess there are GFI outlets that don’t require reset buttons?

  • @MountaineerOutdoors

    @MountaineerOutdoors

    10 ай бұрын

    Sounds to me like it's being protected by one of the other gfcis

  • @calvincaltechwhitfield2545
    @calvincaltechwhitfield25452 жыл бұрын

    I replaced 2 working outlets with 2 GFCI 15 amps on a 20a breaker in the kitchen near the sink. Pigtailed them black to line(brass) white to line(silver) to both GFCI and I put a tested on the terminals and get lights on the voltage tester and with a meter 120v but when I plug any thing in, I get nothing. Double checked incoming wires for power and get 120 but nothing is power up when a device is plugged in There are no indicator lights on the GFCI. The reset and test buttons do nothing. I even swapped out for another still nothing. What should I look for ?

  • @MountaineerOutdoors

    @MountaineerOutdoors

    2 жыл бұрын

    Make sure you put them on the line side of the gfci

  • @nelsonguerra2973
    @nelsonguerra2973Күн бұрын

    Would two GFCI's back to back make sens for an outdoor bar next to a pool? For safety and soundness reasons.

  • @anthonyesparsen9453
    @anthonyesparsen94534 ай бұрын

    Yup the problem when you use multiple gfci's it becomes a nuisance for the home owner having to reset those up stream in the circuit

  • @matthewstewart6437
    @matthewstewart64372 жыл бұрын

    I have a new circuit for an outdoor patio extension. Hot coming into a double gang box with two GFCI receptacles. Then a third GFCI at a grill station. All are in outdoor approved boxes. I have them wired via your "wrong" method but am confused because the sticker on the load terminals say to only remove if feeding additional GFCIs, which I am. Currently none of the three GFCIs will reset with the breaker on. I originally had the first box wired via the pigtail method to the line terminal on receptable 1, then load on receptable 1 feeding line on receptacle 2, then load on receptable 2 feeding line on receptacle 3. The breaker would trip instantly at the panel every time. These 3 receptacles are the only 3 on this circuit. I am going to try your "correct" method. But, my gut also is telling my that I may a ground wire coming in contact with a neutral or hot once I jam everything back into the double gang box as it is super tight. Any suggestions would be much appreciated.

  • @MountaineerOutdoors

    @MountaineerOutdoors

    2 жыл бұрын

    That's what it sounds like to me. You have to use the line on every gfci. And make sure that nothing is touching the box nuetral. Let me know if you fixed it