How Many Conductors Can Be Put in a Pancake Box by 2020 NEC? (Box Fill Article 314.16)

Amazon Prime Student 6 month Free Trial: amzn.to/2J4txZw
Amazon Prime Video Channel Free Trial: amzn.to/3mwgUEW
Hubbell-Raco 295 1/2-Inch Deep 1/2-Inch Bottom Knockouts 4-Inch Round Ceiling Fan Support Pan: Amazon: amzn.to/3nKfnfN
Hubbell-Bell PRCF57550GY Ceiling Fan Electrical box, Gray: Amazon: amzn.to/3mHJK5g
Westinghouse Lighting 0110000 Saf-T-Brace for Ceiling Fans, 3 Teeth, Twist and Lock,Silver(Pack of 1): Amazon: amzn.to/2KL9jEV
Hubbell Raco 936 Ceiling Fan Box and Support, 4 in: Amazon: amzn.to/3peWamv
Hubbell-Raco 294 2-1/8-Inch Deep, 1/2-Inch Side Knockouts, Wood Joist Bracket 4-Inch Octagon Ceiling Fan Support Box: Amazon: amzn.to/3nBHdLb
DEWALT DCN701D1 20V Max Cordless Cable Stapler Kit: Amazon: amzn.to/36CA5rS
National Electrical Code 2020, Spiral Bound Version (National Fire Protection Associations National Electrical Code) 1st Edition: Amazon: amzn.to/3omAbK5
NFPA 70, National Electrical Code (NEC) Handbook, 2020 Edition 1st Edition: Amazon: amzn.to/37JUjPz
NFPA 70, National Electrical Code (NEC), 2020 Edition: Amazon: amzn.to/39X0HFP
Ugly’s Electrical References, 2020 Edition: Amazon: amzn.to/3lFqWD3
Ugly’s Residential Wiring, 2020 Edition: Amazon: amzn.to/3lJXQTe
Ugly’s Conduit Bending, 2020 Edition: 2020 Edition 3rd Edition: Amazon: amzn.to/3qnW2CF
Ugly's Electric Motors and Controls, 2020 Edition Spiral-bound - July 10, 2020: Amazon: amzn.to/39SbyRB
Ugly's Electrical Safety and NFPA 70E, 2018 Edition 4th Edition: Amazon: amzn.to/3oxE3Ik
NFPA 70, National Electrical Code (NEC) Handbook, 2020 Edition 1st Edition: Amazon: amzn.to/37JUjPz
Gardner Bender MCS-100W Multi-Cable Staple, Secures: (NM) Non-Metalic, Coaxial & Data / CAT 5, 100 Pk., Red: Amazon: amzn.to/2LtQGpC
Morris Products Cable Stacker - Secure Hold for Non-Metallic Cables, CATV, Telephone, Instrumentation, Security Cables - Polypropylene - Easy Installation - Pack of 25: Amazon: amzn.to/3oGgBZq
Gardner Bender MPS-2100 Cable Boss Staple, ⅜ Inch., Secures: Coax: RG-6, Voice/Data: CAT 6, (NM) Non-Metalic 14/2, 14/3, 12/2, 200 Pk., White: Amazon: amzn.to/3a1qInF
Gardner Bender PS-150 Plastic Staple, ½ Inch., 14/2, 12/2, 10/2 (NM) Cable, Quick / Easy Installation, for Romex, UF, (NM) & More, 100 Pk., White: Amazon: amzn.to/2JURiUM
Klein Loose Cable Stapler 450-100: Amazon: amzn.to/3hzLdYV
Klein Tools 450-001 Heavy Duty Staples, 1/4 x 5/16-Inch Insulated Staples for CAT3 and CAT5e Data Cables, for Klein Tools Stapler No. 450-100: Amazon: amzn.to/3hzLr2d
Klein Tools 450-002 450-003 and 450-004 Heavy Duty Staples,1/4", 5/16" and 19/32" Insulated Staples for Coax, CAT3, CAT5e Cables, for Klein Tools Stapler No. 450-100: Amazon: amzn.to/39tFBNl
Amazon Prime Student 6 month Free Trial: amzn.to/2J4txZw
Fluke -A1-II Volt-Alert AC Non-Contact Voltage Tester: Amazon.com: amzn.to/13Tw7CY
Leviton GFNL1-W Self-test SmartlockPro Slim GFCI Tamper-Resistant Receptacle with Guidelight and LED Indicator, 15-Amp, White: Amazon: amzn.to/2I0nBRm
Leviton GFTR1-W SmarTest Self-Test SmartlockPro Slim GFCI Tamper-Resistant Receptacle with LED Indicator, 15-Amp, White: Amazon: amzn.to/2Uvzm7c
IDEAL Industries 61-164 SureTest Circuit Analyzer: Amazon: amzn.to/2Da3TwM
Wago (100) 221-412 (50) 221-413 (25) 221-415 Lever-Nut Assortment Pack: Amazon: amzn.to/2WxqHxC
Wago (25) 221-412 (25) 221-413 (25) 221-415 Lever-Nut Assortment Pack: Amazon: amzn.to/2HR6rDY
Wago 221-413 LEVER-NUTS 3 Conductor Compact Splicing Connectors Qty 50: Amazon: amzn.to/2HMeYIr
Wago 221-412 2-Conductor Compact Splicing Connectors (Pack of 100): Amazon: amzn.to/2Oy3Qzm
Shipping, Entertainment, etc. Discounts:
Amazon Prime Student 6 month Free Trial: amzn.to/2J4txZw
Prime Video Channel Free Trial: amzn.to/3mwgUEW
Amazon Prime 30 Day Free Trial: amzn.to/3mqTcdq
Amazon Music Unlimited Free Trial: amzn.to/35IlgC6
Discount on Amazon Prime: amzn.to/37ZJmLN
Audible Gift Membership: amzn.to/31Oxb08
Try Audible and Get Two Free Audiobooks: amzn.to/37NMydc
Amazon Business Account: amzn.to/31NGgGw
Amazon Kids+ : amzn.to/2J6xFIt
Exclusive benefits on Twitch: amzn.to/2HCWNpN
Amazon Home Services: amzn.to/3jxIFez
Kindle Membership Plans: amzn.to/31O9Pro
Amazon Prime as a Gift: amzn.to/3jxxF0U
Create an Amazon Wedding Registry: amzn.to/3jyHL1m
Create an Amazon Baby Registry: amzn.to/35CGa5K
Bill and sparkychannel.com are participants in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com,

Пікірлер: 122

  • @wmcomprev
    @wmcomprev3 жыл бұрын

    You made the comment that we were assuming the ECG inside the box to be 14 AWG, but that it was 12 AWG and could be considered as causing us to exceed the volume calculation. However, as you also showed, 314.16(B)(5) says that the calculation will be made on the largest "entering the box." The ECG that comes preinstalled in the box does NOT "enter the box."

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    Thanks for bringing that up! I edited out that section with KZread editor. You helped me make it a better video! Merry Christmas. 🎄

  • @Ed-uu9eo

    @Ed-uu9eo

    3 жыл бұрын

    I was about to say this. I don't think that article counts the pigtails to base the calculation on.

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    @@Ed-uu9eo Thanks and Merry Christmas! 🎄

  • @michaelmartin5995
    @michaelmartin59953 жыл бұрын

    Bill, Merry Christmas to you and your family. Still one of the best channels on YT!

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    Thanks so much Michael! Merry Christmas. 🎄

  • @Jeff-Lawrence
    @Jeff-Lawrence3 жыл бұрын

    Hi Bill from Sparky Channel Exceptional video as usual This was a really good one, had to read that code twice. They sure make those definitions confusing. Thanks again, really appreciate your hard work making these videos. Merry Christmas

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    Sometimes I think they make the code confusing on purpose. LOL! Merry Christmas! 🎄

  • @WeatherNut27
    @WeatherNut273 жыл бұрын

    Really enjoying these videos referencing the code book and reading it with us. Thank You!

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    Thanks so much! Merry Christmas. 🎄

  • @sledge3003
    @sledge30033 жыл бұрын

    Thanx for another great video!!!.....merry Christmas and all the best in 2021!!!

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    Thanks! Merry Christmas. 🎄

  • @kendrickkimble9763
    @kendrickkimble97633 жыл бұрын

    This guys the best. Learned so much from him.

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    Thanks Kendrick!

  • @iandrew6347
    @iandrew63473 жыл бұрын

    Great video again Sir Just like to say Merry Christmas or Happy Holiday Stay Safe Watching from the uk 🇬🇧

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    Thanks Ian! Merry Christmas. 🎄

  • @patriciamoraga2917
    @patriciamoraga29173 жыл бұрын

    Thank you for sharing all of this info.. you have amazing classes........and if i miss something i just rewind your video...

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    Glad you like them! Happy New Year Patricia!

  • @patriciamoraga2917

    @patriciamoraga2917

    3 жыл бұрын

    @@SparkyChannel a Happy New Year to you as well......!!!

  • @tedmcdonald3377
    @tedmcdonald33773 жыл бұрын

    Merry Christmas Bill, thanks for the videos!!!

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    Thanks Ted! Merry Christmas. 🎄

  • @JohnBGood-kq3ul
    @JohnBGood-kq3ul Жыл бұрын

    Thanks for the very informative video. Direct an to the point. Great job as always.

  • @SparkyChannel

    @SparkyChannel

    Жыл бұрын

    Thanks John!

  • @dougthoutt
    @dougthoutt3 жыл бұрын

    Great video on pancake boxes. Do cable clamps not count against the capacity of the box?

  • @junyue678
    @junyue6782 жыл бұрын

    It is so useful, thank you very much!

  • @stevenneuberger4323
    @stevenneuberger43233 жыл бұрын

    I wonder if an inspector might look at that "bushing" as being an internal cable clamp (314.16(B)(2) which I believe would bring the required space to 8.25

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    They might. The actual truth is that inspectors might say just about anything. But most of that clamp is outside the box so just about everybody would agree that it's an external clamp and not counted. Also, there is a picture in the 2020 NEC handbook with a set-up just like mine. Good question. Merry Christmas! 🎄

  • @thunder3470
    @thunder34703 жыл бұрын

    Thank you even for your gift of explaining things

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    Thanks and Merry Christmas! 🎄

  • @SuperVstech
    @SuperVstech3 жыл бұрын

    Code says largest grounding conductor ENTERING the box. The #12ECG is contained in the box, it does not enter the box. So, it doesn’t count.

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    Yes, that's true. I deleted the part where I was talking about the 12g ECG. Merry Christmas! 🎄

  • @MikeBramm
    @MikeBramm3 жыл бұрын

    Merry Christmas Bill and family.

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    Thanks and Merry Christmas🎄 to yourself and family!

  • @Eddy63
    @Eddy633 жыл бұрын

    Good 1 Wild Bill ... Merry Christmas to you and the NEC Code people ... Lol ...

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    LOL! Merry Christmas. 🎄

  • @billrutledge2962
    @billrutledge29622 жыл бұрын

    Bill. Can send me a link to the white light fixture you used in this video. I have been looking for a light fixture like that

  • @SparkyChannel

    @SparkyChannel

    2 жыл бұрын

    Hi Bill! It's just a cheap porch light that I bought at Home Depot. They used to cost $5, now they probably cost $10.

  • @philipbieniecki3819
    @philipbieniecki38193 жыл бұрын

    Good job 👍

  • @sfnsfn6628
    @sfnsfn66283 жыл бұрын

    If the light canopy (domed cover) is marked with a box fill volume, can that be added to the pancake box fill volume to give a total increased box fill volume?

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    Yes. But it's unusual to find a canopy or doom that is listed and labeled for wire fill. Merry Christmas! 🎄

  • @garydudgeon
    @garydudgeon3 жыл бұрын

    Good explanation Sparky.

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    Thanks Gary! Merry Christmas. 🎄

  • @joer9276
    @joer92763 жыл бұрын

    So we don’t have to count the cable clamp in the pancake box but do on the ones molded into the blue nm boxes? Makes sense? Merry Christmas!

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    The blue NM boxes with the integral clamps are quite controversial as to whether they would need to be counted as internal clamps. My internet search came up with about 50% yes and 50% no for people's opinions on that. Merry Christmas! 🎄

  • @bksamander
    @bksamander3 жыл бұрын

    When a fixture is connected to a pancake the space it provides for wire connections should be taken into account when calculating max fill values. 314.16 (A) Box Volume Calculations. The volume of a wiring enclosure (box) shall be the total volume of the assembled sections and, where used, the space provided by plaster rings, domed covers, extension rings, and so forth, that are marked with their volume or are made from boxes the dimensions of which are listed in Table 314.16(A).

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    Thanks! Merry Christmas. 🎄

  • @MikeSully01

    @MikeSully01

    3 жыл бұрын

    I think the only thing an inspector could get you on with that one is the "that are marked with their volume" most, if not all fixtures aren't, even though I agree they should count.

  • @billybilodeau1991
    @billybilodeau19913 жыл бұрын

    Why use a bonding jumper when you can wrap the romex bonding wire around the green screw it’s self? Even if we used a 14 awg jumper and don’t have to count it, it still does take up some room. I also like using small orange wire nuts in that situation because they are smaller then the wagos. We don’t have to figure them in for box fill code wise but in reality they do take up room and depending on the fixture bigger wire nuts or wagos can get in the way.

  • @kenbrown2808

    @kenbrown2808

    3 жыл бұрын

    I agree. I'll also have to double check when I get my handbook, because I prefer the 3.5" pan box, which is only made legal by the volume of the fixture canopy, so if they've started to prohibit adding canopy volume, I'll have to find another way to get box volume without cutting into my margin of error by using 4 inch boxes. also, if you haven't played with them, I like the 3M O&B wire nuts for connecting fixtures in close quarters.

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    That's a good technique which does save space. Merry Christmas. 🎄

  • @billybilodeau1991

    @billybilodeau1991

    3 жыл бұрын

    My boss, as I was an apprentice, never let use use 3” pancake boxes and so i still don’t. Usually fixtures thar require a small splice box NEED a metal 1gang box, because of the size and shape of the canopy. I’m always surprised they are allowed to make such fixtures seeing as how there’s no boxes technically rated to hold them. (As far as i know) And I’ve never seen a 1gang metal mudring tapped for 8-32’s...that would be great lol

  • @billybilodeau1991

    @billybilodeau1991

    3 жыл бұрын

    Merry Christmas Sparky

  • @lockpickingvlad

    @lockpickingvlad

    2 жыл бұрын

    That’s how I do it. 👍🏻

  • @aldavison420
    @aldavison4202 жыл бұрын

    Can we surface mount these pancake boxes?

  • @chrisharper2658
    @chrisharper26582 жыл бұрын

    It looks like your ground pigtail may actually be #12 AWG so wouldn't that push you over the 6.0 CU INCH limit or does the pigtail not get counted? Seem odd that because of the regs, using #12-2 wouldn't be allowed even though the biggest issue with those boxes is fitting the wire nuts into that tiny space and not the air gap around the wires. Those flat Wago lever-nuts sure are a big help and yet they're not required.

  • @jamesalvin5735

    @jamesalvin5735

    Жыл бұрын

    You're right that the pigtail is #12, but 314.16(B)(5) says that the calculation shall be based on the largest conductor "entering" the box, which would be the bare #14. The "entering" distinction was added in the 2020 edition, so if you're using an older edition, that would explain your confusion 🤙

  • @drexrew
    @drexrew2 жыл бұрын

    Why would you have a separate grounding wire for the box ground screw, just wrap the bare copper ground wire around the screw and then connect the device ground to the wire. No need for an extra wire.

  • @Jason_Canada

    @Jason_Canada

    2 жыл бұрын

    3 conductors but really its a 14/2 with marettes

  • @Jason_Canada

    @Jason_Canada

    2 жыл бұрын

    Smack that box ...Bill

  • @Jason_Canada

    @Jason_Canada

    2 жыл бұрын

    Personally I would of used the bond wire around box screw then the green to the wiggee

  • @WeatherNut27
    @WeatherNut273 жыл бұрын

    The last paragraph new to 2020 is throwing me off. What does "based on largest" mean? If we had 12-2 conductors in the pancake box and the additional ground was 14-2 does that mean we dont add that 1/4 volume?

  • @kenbrown2808

    @kenbrown2808

    3 жыл бұрын

    it means you count the first four grounding conductors as 1 conductor count of the size of the biggest. say you have a #12, a #14, and a #18, like in his example, you would count them all as 1 #12. if you had a multigang switch box with 6 #14 grounding conductors, you would count the first 4 as one #14, and then count the next two as two quarters of a conductor count,

  • @DarkD112
    @DarkD112 Жыл бұрын

    Thankfully, CEC is much nicer. We only count insulated conductors, so the ground is out. And #14 AWG only uses 1.5 cubic inch per insulated conductor. Although, we have a rule that counts every two wire-caps as an insulated conductor. So our fill only goes up to 4.5 cubic inches. Also, where are you getting 6 inches from for pancake boxes. The number I googled says they're 5.5 inches cubed.

  • @stevelopez372

    @stevelopez372

    Жыл бұрын

    Now it is. Was not so nice in previous code cycles. Of course I have been retired for 3 code cycles,Lol.

  • @luvdady

    @luvdady

    3 ай бұрын

    It's stamped on the box

  • @torodaman
    @torodaman3 жыл бұрын

    What I do so it could be less busy with wires in the pancake bx, No ground pig tail install in the bx, I leave the ground wire extra long and just wrap it on the ground screw with 5 inches long b4 the screw and wrap it inside along the edge of the bx out of the way and 6 inches after, and you eliminate an extra pice of wire and make it roomier in the tiny bx, but to answer ure question, only one wire in the pancake bx.

  • @Nick-bh1fy

    @Nick-bh1fy

    3 жыл бұрын

    Btw bro “bx” also refers to an armoured cable not box

  • @stop2kare472

    @stop2kare472

    3 жыл бұрын

    I believe he did that for demonstration purposes only. I'm sure he's out in the field doing good work👍🏽

  • @luktish
    @luktish21 күн бұрын

    Anyone knows some video showing which type of light fixtures count into the total box volume, which don't?

  • @Sparkeycarp
    @Sparkeycarp2 жыл бұрын

    How many times have you opened up a pancake box and seen a splice going to another place? Especially bathrooms.

  • @jamiedrover6192

    @jamiedrover6192

    Жыл бұрын

    I was hoping this would work to center a bathroom light. It wont pass because theres a splice going somewhere else No wires are allowed to exit. Is that correct?

  • @Shadi2
    @Shadi23 жыл бұрын

    I like Saddle or L shaped fan boxes. Much more CU (12 & 16).

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    Yes, excellent point. Merry Christmas. 🎄

  • @--JohnDoe
    @--JohnDoe3 жыл бұрын

    I learned "new update" you also add a 1/4 volume allowance for each additional e.g.c. Thank you.

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    Yes, that's the new update. I'll be using that update in a future video. Merry Christmas. 🎄

  • @--JohnDoe

    @--JohnDoe

    3 жыл бұрын

    @@SparkyChannel Merry christmas bill.

  • @MrTooTechnical
    @MrTooTechnical3 жыл бұрын

    Woohoo. Merry Xmas

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    Merry Christmas Dave. 🎄

  • @jgoddard0757
    @jgoddard07573 жыл бұрын

    Noticed in the last couple vids youre wear HD gorilla gloves. Are you wear these at work? I do and find they give excellent dexterity and feel while protecting my hands.

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    I like them because they protect my hands from little scrapes and they give a good grip on things. They're nice little gloves IMO. Merry Christmas. 🎄

  • @HashBandicoot356
    @HashBandicoot356 Жыл бұрын

    So if you had 2-4 grounding conductors it is still 2.00 cu In, but if you had 5 it would be 2.5 cu in.?

  • @mae2759

    @mae2759

    Жыл бұрын

    Yes.

  • @--JohnDoe
    @--JohnDoe3 жыл бұрын

    Bill I think your box fill is 6.0 not 6.25. It says "entering the box" that 12awg grounding pigtail originates from that box, it doesn't enter it. Am I wrong?

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    You are correct. I edited my video taking out the part about the 12 ga EGC. I learned a good one there! Merry Christmas. 🎄

  • @michaelc.3812
    @michaelc.38123 жыл бұрын

    This wouldn’t be acceptable for ceiling fans with a 14-3 NM cable, not for any daisy chain lights. Just a single run of 14-2. Of course the new 2020 ceiling fan box requirements apparently rule this box type out.

  • @Arieeeee
    @Arieeeee3 жыл бұрын

    Awesome video! This must be the biggest code violation in the world because it means that even a single 12/2 wire will go over the 6 cubic inch limit and yet I've seen it all the time and may or may not have been guilty of committing it myself! I guess your alternative there is those NM fan boxes that let you screw directly in the jost but even those only have 12 cubic inches of capacity.

  • @KitchenerLeslie2

    @KitchenerLeslie2

    3 жыл бұрын

    Some of my coworkers use those for regular fixtures in place of pancake boxes. They stink. All the extra plastic interferes with most fixture brackets.

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    Thanks and Merry Christmas! 🎄

  • @nickm9123
    @nickm91233 жыл бұрын

    in nj, that could fail in new con. if the inspector is a jerk, because we have to have allowances for "future work" i.e, you cant meet box capacity, you have to have a minimum of 1 cubic inch extra.

  • @kenbrown2808

    @kenbrown2808

    3 жыл бұрын

    years ago, I had an inspector tell me that if everything is folded in neatly, and there is obviously plenty of space for the devices or fixture connections, he wasn't going to be bothered counting conductors. which was a relief because the box he was looking at was at its maximum conductor fill.

  • @playnationtoday

    @playnationtoday

    3 жыл бұрын

    That’s kind of crazy! 1 cu. in. Won’t get you anything more than what the box already allows!

  • @markmadlena6009
    @markmadlena60093 жыл бұрын

    One wire. Or two or three if the inspector doesn’t catch it.

  • @philiphorner31
    @philiphorner312 жыл бұрын

    Pancake box will need a bump on backside to carry 12-3 or 14-3.

  • @canadiantrucker9574
    @canadiantrucker95743 жыл бұрын

    As many as you can possibly cram into the box?

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    LOL! Merry Christmas. 🎄

  • @canadiantrucker9574

    @canadiantrucker9574

    3 жыл бұрын

    @@SparkyChannel Merry Christmas to you too Bill, have a blessed holiday season

  • @chaseoes
    @chaseoes3 жыл бұрын

    Can you make a video about interconnected smoke detectors?

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    Yes, I'm planning on it. Merry Christmas! 🎄

  • @alsentman9390
    @alsentman93903 жыл бұрын

    I was under the impression that the "conductor" consisted of the hot and neutral wire. Please correct me if I'm wrong. Currently reading and watching videos to learn electrical.

  • @captainteamcarry3

    @captainteamcarry3

    3 жыл бұрын

    Copper wire or green wire is the grounding conductor.

  • @jamesalvin5735

    @jamesalvin5735

    Жыл бұрын

    Both the hot wire and the neutral wire are current carrying conductors. They each count as one.

  • @philiphorner31
    @philiphorner312 жыл бұрын

    So we can't use #12 wire. Rediculous

  • @SparkyChannel

    @SparkyChannel

    2 жыл бұрын

    Yep.

  • @wolfworrier3169
    @wolfworrier31693 жыл бұрын

    ? Sir what problems could you have at home for your utility bills to keep going up ?.could it be wiring

  • @mikeeat7918

    @mikeeat7918

    3 жыл бұрын

    To much stuff on large appliances don’t think the wiring could have anything to do with that. How big is your house?

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    Utility Bill problems are usually from heating (including heating food) and cooling (including cooling food). LED lights have dramatically reduced utility expense from home lighting. Wiring is not usually an issue. Merry Christmas. 🎄

  • @wolfworrier3169

    @wolfworrier3169

    3 жыл бұрын

    4 rooms

  • @stevenneuberger4323

    @stevenneuberger4323

    3 жыл бұрын

    I suspect restrictions due to the COVID-19 pandemic might contribute.

  • @yzmoto80
    @yzmoto803 жыл бұрын

    Hmm, 14-3 w/ground NOT allowed in a 6 cu. in. pancake box.

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    That's correct.

  • @andydelle4509
    @andydelle45093 жыл бұрын

    So basically you can't use #12/2 with a pancake box period? I'll bet that get's very lightly enforced.

  • @Nick-bh1fy

    @Nick-bh1fy

    3 жыл бұрын

    Typically you won’t even use a pancake unless for a keyless fixture

  • @clayadams2068

    @clayadams2068

    3 жыл бұрын

    We use pancakes for almost all surface mounted lights unless center comes out on the edge of a joice.

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    You're correct. 12/2 with ground wouldn't work. Merry Christmas! 🎄

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    Gotta love keyless fixtures! The old gas fixtures had keys so the invention of the electric lights were "keyless". Merry Christmas! 🎄

  • @crazycomments2.178

    @crazycomments2.178

    Жыл бұрын

    @@SparkyChannel What if you run type AC cabling back to the the previous box, and ground the the fixture directly to the box? So you have 0 grounds, 2 #12s, and 3 omitted fixture wires

  • @kirkshirley1319
    @kirkshirley13192 жыл бұрын

    If hickeys and nipples each count as one conductor then you forgot to include the threaded nipple in your total. Pancake boxes that come with the metal cable clamps inside should now be delisted or exempted in the code.

  • @tevman69
    @tevman693 жыл бұрын

    Math, does not lie.

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    No, it sure doesn't! Merry Christmas. 🎄

  • @williambarry4693
    @williambarry46933 жыл бұрын

    There needs to be a simpler explanations.

  • @SparkyChannel

    @SparkyChannel

    3 жыл бұрын

    I hear you.