How I Installed A DUCTED Minisplit In My Bus Conversion

I go through the whole process of adding a DUCTED Minisplit system to my bus conversion. I have not seen any other skoolie with this setup and I thought I would try it out. After creating a drop ceiling in the bus I was able to run ducts through the ceiling to have central AC.
Thanks for watching! Enjoy!
#busconversion #buslife #tinyhome
Check me out on Instagram!
/ skooliebro

Пікірлер: 18

  • @danielfluty1373
    @danielfluty13739 ай бұрын

    Very impressive work, Dan. I discovered your channel through a KZread Short and now want to watch the whole Skoolie build! Your workmanship is second-to-none. One of the best bus builds I’ve seen to-date. 👌🏼

  • @DanZalinsky

    @DanZalinsky

    9 ай бұрын

    Thank you so much!! Appreciate that. I'm glad you enjoy the channel.

  • @phillyguy8541
    @phillyguy854110 ай бұрын

    Great system.

  • @DanZalinsky

    @DanZalinsky

    10 ай бұрын

    Thanks! Yeah Im glad I went with this unit.

  • @claytonjames4779
    @claytonjames47796 ай бұрын

    I'm about to install one of these in my house upstairs and this is great!!

  • @DanZalinsky

    @DanZalinsky

    6 ай бұрын

    Love the ducted minisplit!!

  • @Swerly01
    @Swerly0110 ай бұрын

    I didn't even know they made those! Looks great!

  • @DanZalinsky

    @DanZalinsky

    10 ай бұрын

    Thanks! Yeah I didnt even know before I started the build. But I figured it would work out!

  • @tylermccubbin63
    @tylermccubbin633 ай бұрын

    A small section of Braided stainless steel lines before your flares would reduce probability of leak from vibration

  • @DanZalinsky

    @DanZalinsky

    3 ай бұрын

    I have thought of that but never did it. Thank you for the feedback. Appreciate that.

  • @CHRISpective_
    @CHRISpective_10 ай бұрын

    Wow you dont see that often

  • @DanZalinsky

    @DanZalinsky

    10 ай бұрын

    Yeah, went with a different design here!

  • @tylermccubbin63
    @tylermccubbin633 ай бұрын

    How’s it doing without volume dampers?

  • @DanZalinsky

    @DanZalinsky

    3 ай бұрын

    Its doing great. No issues with even air flow. The back vent has a damper on it. So if I need to I will close that slightly.

  • @R22AP
    @R22APАй бұрын

    Any issues with the transformer being for EU standard 220v with live, neutral and earth whereas the unit requires US split phase live, live, earth? Seville told me it wouldn’t work when I asked. Assume no unexpected issues or case electrification due to bonded neutral?

  • @DanZalinsky

    @DanZalinsky

    27 күн бұрын

    No I havent had any issues with the 220v. I followed Victron the victron wiring diagrams to make sure everything was grounded and bonded correctly.

  • @R22AP

    @R22AP

    27 күн бұрын

    @@DanZalinsky awesome. Good to know. No real need for split phase for these then, just any 220v feed?

  • @DanZalinsky

    @DanZalinsky

    27 күн бұрын

    @@R22AP Yeah no split phase needed