How A Single Solar Battery Is Powering A 32 Hotel Rooms In Edo State, Nigeria.

How A Single Solar Battery Is Powering A 32 Hotel Rooms In Edo State, Nigeria.

Пікірлер: 127

  • @emmyokonkwo290
    @emmyokonkwo29019 күн бұрын

    It is not the size of house that matters, but the load in the house. This setup is not for AC but bulbs, fan and TV

  • @abisaiamatalo2769
    @abisaiamatalo276925 күн бұрын

    This is a Lithium Iron Phosphate (LiFePo) battery pack. It has many batteries inside connected in series-parallel configuration, and inverter chargers. This is very common here in Kenya in Off grid connections. There is nothing difficult here. Anyone who has an electrician diploma or certificate can do its wiring. For the above video, the hotel has energy saving bulbs, Probably LEDs, Phone charging sockets. The AC is probably connected to a few rooms.

  • @danielekweo.9770

    @danielekweo.9770

    22 күн бұрын

    Critically analyzed by you..

  • @tvbela2023

    @tvbela2023

    4 сағат бұрын

    That guy is just talking as if he does not know that solar power professionals will see this video . This video just show a high level of ignorant

  • @LexionKing
    @LexionKing26 күн бұрын

    You keep dissing the Generators and Transformers. Oya power all the ACs in the 32 Rooms with your 17.5KwH battery and 10KVa inverter na. Why you put only 3? 🙂 Do you know how many thousands of Kilowatts are consumed daily either through Grid Power or Heavy Duty Generators ? The inverter setup to do that will make the Transformer and Generator Prices a Joke. And for your info, 70% of the Daily Power consumption of that Hotel are the Air Conditioners. That's a necessity before most customers pay for a Hotel room anyways. So, the inverter is good, but certainly still needs major help from the Generators

  • @miltonchadwick

    @miltonchadwick

    24 күн бұрын

    Don't mind the liar!

  • @peterigwilopi

    @peterigwilopi

    22 күн бұрын

    Liar? The owner is saving money because he's using both the solar and generator alternatively​@@miltonchadwick

  • @GTdontDOthat

    @GTdontDOthat

    21 күн бұрын

    d amount to power all d ac and all d load na better money .all dis can only power d light load in day time

  • @topreviews7690

    @topreviews7690

    15 күн бұрын

    Yeah, that does not make any sense 17kw will only run a home a normal American home for half a day 12 hours hours much less run 38 rooms and especially on that single inverter stop playing games on the KZread

  • @adamstaiwo7779

    @adamstaiwo7779

    11 күн бұрын

    😂😂😂😂😂😂 naija my country haba 17.5kw how for where with a/c no way pls it only for lighting and fans in the rooms dey have guess not all unless you make the battery 🔋 like 30/40kva that will power all the rooms lights and fans successful including the bar for some hours not all days for the a/c you still need the generator

  • @eddyemmanuel512
    @eddyemmanuel51227 күн бұрын

    See lies 🤦‍♂️ 17.6kw system for this hotel Bros fear God o. Believe this at your own risk ⚠️

  • @GTdontDOthat

    @GTdontDOthat

    27 күн бұрын

    maybe they fail to inform us that this is only for day time wen d solar panel is producing but it can never power d hotel at night

  • @beejsplacegamesloungelagos5157

    @beejsplacegamesloungelagos5157

    27 күн бұрын

    @@GTdontDOthat Almost all the info is wrong,you can list the size of an apartment as and estimate of power or duration of the power supply,the whole of sheraton if not a single bulb or electrical item is on will consume 0kw a year while a container with bitcoin miners can consume 10 kw a day..A lot of the info there are just upside down.

  • @GTdontDOthat

    @GTdontDOthat

    27 күн бұрын

    @@beejsplacegamesloungelagos5157 i also use solar.d thing surprise me and i say maybe na only day time wen d panel dey produce power

  • @elmultimediaschoolofartscu3924
    @elmultimediaschoolofartscu39245 күн бұрын

    ❤❤❤❤ Brother, for an African i congratulate you, don't focus on negative ernegy. People in Africa don't like to share knowledge 😢😢, keep going brother. I learnt a few things from you 😊😊😊❤❤❤❤🎉🎉🎉🎉 🥳

  • @GTdontDOthat

    @GTdontDOthat

    4 күн бұрын

    dey play and believe rubbish

  • @donptv433
    @donptv43324 күн бұрын

    14 solar panel is @500 watt is 7000watt =7kw. @32 rooms with lightning ⚡ point and air conditioning @1.5kw. what is the battery capacity. In conclusion the solar panel and battery is not fully for the load

  • @GTdontDOthat

    @GTdontDOthat

    22 күн бұрын

    also note 500watt will never produce up to 500watt

  • @shizzysmith2514

    @shizzysmith2514

    11 күн бұрын

    Anybody that give this one job he do enter trouble

  • @ClementElectrical11
    @ClementElectrical1123 күн бұрын

    Good work my brother but all the Air conditioner won’t be on all the time there’s a load separation on the Distributional board

  • @ikpalian4413
    @ikpalian441311 күн бұрын

    I can only accept this, if is carrying critical load during off grid with energy saving bulb in the 32 rooms❤. Try on any heavy appliances if they will not call u back.

  • @justusmarthin853
    @justusmarthin85325 күн бұрын

    The iron battery is like how much in naira for those who are interested but stay abroad Please can someone inform the correct amount of iron battery for solar

  • @OmosagbaKoleIsraelResonance
    @OmosagbaKoleIsraelResonance7 күн бұрын

    This solution is easier said than done. Let wait for the next 6-12 months

  • @ArrèyJAE
    @ArrèyJAE29 күн бұрын

    "They fit seize light, they no fit seize sun" legendary words my bro. Solar is the future in deed.

  • @CExcel

    @CExcel

    25 күн бұрын

    😂😂😂 SUN IS NATURAL BY GOD.

  • @michaelan139

    @michaelan139

    23 күн бұрын

    sun de seize every night

  • @GTdontDOthat

    @GTdontDOthat

    23 күн бұрын

    @@michaelan139yes light in my area na rain every day

  • @KD-tp7cg

    @KD-tp7cg

    8 күн бұрын

    What guys don't understand is if the rain keeps failing every day like the 1 week, the sun is nearly out and less charge is stored, we have to make use of Nepa to charge. Nepa even charges the batteries faster than the sun

  • @relaxationstudio1270
    @relaxationstudio127029 күн бұрын

    This is an hybrid inverter but, they don't use it that way..... This one can light up the hotel energy saving bulbs and some small loads.... Battery determine the backup time. That battery can last on bulb only and few load. Average house uses about 50kw of power per day not to talk of an hotel..... If you know about inverter, you know.... The cost of that inverter pass those generator

  • @danielokwum248

    @danielokwum248

    28 күн бұрын

    It is apparent most installers don't really understand the basic numbers when it comes to renewable energy. If conservatively, all rooms uses a 5 units of 5watts bulbs, 40 inches tv, tge table top refrigerator, the hotel's low voltage equipments, etc. Your run time on that battery alone might not exceed 2 hours. This battery DOD of discharge is at 80%.

  • @Swit-Elect

    @Swit-Elect

    28 күн бұрын

    Don’t mind the Olodo. He said 17.5KWH is equivalent to 15 220ah tubular batteries. 4 batteries is 10KWH. 8 is 20KWH. The DOD of the lithium battery IS 98% compare to tubulars. Which is at most 50 to 70% DOD

  • @outtersteller

    @outtersteller

    28 күн бұрын

    @@Swit-Electalthough he isn’t accurate but he isn’t wrong either, people often forget tubular batteries has a usable capacity of 50% Which means 15 12v 220amps is likely 19kw... and that’s without factoring the mixture of parallel and series connection to get a 48v architecture ....

  • @GTdontDOthat

    @GTdontDOthat

    27 күн бұрын

    maybe they fail to inform us that this is only for day time wen d solar panel is producing but it can never power d hotel at night

  • @michaelakomolafe9249

    @michaelakomolafe9249

    20 күн бұрын

    ​@@Swit-ElectThey are just creating content for the ignorant.

  • @yungpass1
    @yungpass121 күн бұрын

    One of the generators can power the whole hotels both the ACS but the solar can not power quarter of the ACS. Just the play

  • @wizlipskings8958
    @wizlipskings895826 күн бұрын

    1 water heater pull 2000 to 3000 watts of power , so imagine 3000watts x 34 rooms 102kw of power and u have 17kw. This can last 1hour if you give this hotel full load, imagine, tv , fan at max , at night it wont last ...at all

  • @GTdontDOthat

    @GTdontDOthat

    26 күн бұрын

    maybe it power only light load like light,tv and fan in d day time wen d solar is producing.dis cant carry d hotel at night.not possible

  • @wizlipskings8958

    @wizlipskings8958

    25 күн бұрын

    @@GTdontDOthat yeah , but his video made it look like it will sustain the loads , especially at night.

  • @anyiegopatricks1869

    @anyiegopatricks1869

    21 күн бұрын

    Nawao 😮

  • @surajudeenayoola4591
    @surajudeenayoola459123 күн бұрын

    It can carry the load of fan, bulbs but not Air conditioner

  • @alarapeedrees2903
    @alarapeedrees290326 күн бұрын

    ❤😂🎉 well try

  • @nwaaba1778
    @nwaaba177829 күн бұрын

    Make person babe/wife/husband show face for this video. You go explain tire...😂

  • @shookoneldn300

    @shookoneldn300

    29 күн бұрын

    😂😂😂

  • @ashestoashes6902

    @ashestoashes6902

    26 күн бұрын

    😂😂😂😂😂😂

  • @krayonnesilva390
    @krayonnesilva39011 күн бұрын

    I believe those rooms have fans and not ACs but solar is the way to go like he said.

  • @emmank3710
    @emmank371027 күн бұрын

    Hw much for this system

  • @asikaohadike8993
    @asikaohadike899322 күн бұрын

    The entire installation is a 20Kva with 17.5Kwh Lithium Backup, you can not run more than 5 Air-conditioner on this entire system. My concerns lie more with how many Good weather / sun hours Benin has in a year.

  • @GTdontDOthat

    @GTdontDOthat

    21 күн бұрын

    even with good sun.this cant power d hotel at night

  • @crimeandcontroversy9042

    @crimeandcontroversy9042

    11 күн бұрын

    how much does ot cost

  • @kaseamate9080
    @kaseamate908017 күн бұрын

    Luckily for you to say it was only for 3 AC and other lighting points. Lol, i was expecting you to say the system will power all the AC in that hotel, and mind you the 14 sets of 500w solar panels won't be enough for this system and the Battery won't get enough charge from them if you're using the system on daytime. Well nice job

  • @GTdontDOthat

    @GTdontDOthat

    17 күн бұрын

    me alone i dey use 18 units of 625 halfcut panel.not to talk of hotel with many rooms

  • @chukwuemekaegbuonu6695

    @chukwuemekaegbuonu6695

    7 күн бұрын

    This installation can only run 1 air conditioner all though the night.

  • @greattom3605
    @greattom360526 күн бұрын

    Hey Daddy you can lie ooooo😂😂😂😂😂😂😂😂😂

  • @ashestoashes6902

    @ashestoashes6902

    26 күн бұрын

    😂😂😂😂😂

  • @shizzysmith2514

    @shizzysmith2514

    11 күн бұрын

    HIs just saying rubbish

  • @johnvincent4993
    @johnvincent499322 күн бұрын

    It is good that the talkshow is promoting the guy but i being a pro in solar system, there are more things not said than said. I rest my case

  • @GTdontDOthat

    @GTdontDOthat

    21 күн бұрын

    u dont need to be solar pro to know dis cant power d hotel well

  • @uzochukwujustin6452
    @uzochukwujustin645220 күн бұрын

    Haba Bros. How he gontalk say that 17kwh na like 15 of tubular. 4 units of 220ah tubular is approximately 10.5kwh meaning that 8 of it is 21kwh. How 15 u it's come take be 17kwh. Nawa o 😂

  • @seunsonoiki6979

    @seunsonoiki6979

    18 күн бұрын

    from tubular batteries , you can only use 50% of its rated capaccity for a longer life span.

  • @uzochukwujustin6452

    @uzochukwujustin6452

    18 күн бұрын

    @@seunsonoiki6979 that the theory on paper. But have you compared both side by side? Cause I have. Put the same load on each and record the time it takes to completely consume.

  • @oluwatoyinjegede3348

    @oluwatoyinjegede3348

    15 күн бұрын

    U KNOW EDO PEOPLE LIKE EXAGERATION NAH

  • @kenazuka7521

    @kenazuka7521

    12 күн бұрын

    Good! If 8 tubular is approximately equal to this one 17kw lithium.. lithium is always times 2 efficient that it's equivalent tubular battery because of the DEPT OF DISCHARGE

  • @Dr._Aniekan_udo

    @Dr._Aniekan_udo

    12 күн бұрын

    Have you heard of 100 ah tubular battery too? And have you heard of discharge efficiency? 98% discharge efficiency is not same as 50% to 60% discharge efficiency. So he is not far from being correct. Each 200ah tubular battery is 2.6kwh, but you can only extract 1.3kwh to 1.56kwh from it. And if you want it to have a longer lifespan you should avoid full discharge. With expert standard suggestion of 50% discharge you are left to use 0.65kwh to 0.78kwh. You can use the full 1.56kwh if you don’t mind. For LiFePo of 17kwh you can have up to 98% extraction, which give you 16.7kwh So for the most efficient ones (60% eff.) tubular in full usage is 11*200 ah = 17.16 kwh Tubular in Lifespan mindful usage(50% cap) 21*200 ah = 16.4 kwh I have a 1.2kwh LiFePo and have don reallife test using my friends 2*200ah tubular battery which is 4.8kwh. My friend had to change his tubular battery after it became very weak in 2 years. Also he does maintenance check every 6 months, while I haven’t done any. Lifepo4 only drops by 80% in about 4 years. Another benefit I discovered was that LiFePo battery also charges faster, even when sun shine is weak like this time that we are having rainy season.

  • @profprof5816
    @profprof581623 күн бұрын

    Why would the battery be in operation during the day when the sun is at its fullest energy? The battery should be charging and automatically goes off if full. During the day, power should be from the solar to inverter and to appliances. At night it should be from Battery to Inverter and appliances.

  • @GTdontDOthat
    @GTdontDOthat29 күн бұрын

    u fail to inform us that this is only for day time wen d solar panel is producing but it can never power d hotel at night

  • @OjibaMario
    @OjibaMario2 күн бұрын

    One 17.5kwhr battery can't give you 15 tubular battery.. Mathematically one tubular battery is 2.64kwhr(12*220) multiplied by 8 that's about 21kwhr.. The advantage lipo battery has is better BMS, ease of maintenance, life span so one 17.5kwhr can never be up to 15 12v 220ah

  • @trendinginfotech
    @trendinginfotech7 күн бұрын

    Generators are good choice for hotels not solar Due to AC and heaters and other heavy recessive loads. Cost of solar will be too much to buy a good generator or two generators

  • @stephensunday7048
    @stephensunday704810 күн бұрын

    Solar is the way but your 20kva is not enough,I did something like this for my client but with 2pcs of 17kw lithium battery, that's for a person house o,how much more of this with only 1pcs of 17kw battery for hotel of 32rooms

  • @electricvehiclesug256
    @electricvehiclesug2567 күн бұрын

    Forsure solar is the way

  • @degreatcornelius5292
    @degreatcornelius529225 күн бұрын

    You no tell us how much 😊

  • @oluwoleodetola1626
    @oluwoleodetola162618 күн бұрын

    Solar can be good but not reliable........Nigeria fixing it's electricity challenge is still the best.

  • @seunsonoiki6979

    @seunsonoiki6979

    18 күн бұрын

    its reliable if properly designed

  • @oluwoleodetola1626

    @oluwoleodetola1626

    18 күн бұрын

    @seunsonoiki6979 lol You only run on solar?? You don't use Nepa anymore??

  • @GTdontDOthat

    @GTdontDOthat

    16 күн бұрын

    wetin u dey talk.i get 18 units of 600watt half cut panel with 12 unit of 230ah battery.my solar dey work well with 3 inverter ac.2 fridge.4 big tv.micro wave.washing machine.pumping machine and many more .my solar dey generate 4000watt wen weather bad and almost 10000watt wen sun dey.spend good money on solar and enjoy but not for hotel bcos d rooms many but can power few load wen sun dey

  • @elvisgregor8403

    @elvisgregor8403

    13 күн бұрын

    Nigeria electricity can never be fixed.. Even one presidential aspirant owns mikano Gen 😅

  • @krayonnesilva390

    @krayonnesilva390

    11 күн бұрын

    I only run solar in my house and it's very reliable

  • @Idemudia-pk2ob
    @Idemudia-pk2ob25 күн бұрын

    Whyy you dey mouth wash the generator and transformer na.. like say na you manufacture the inverter and battery 😂😂 na wah oh

  • @obichukwuebukajames1209
    @obichukwuebukajames12098 күн бұрын

    I want wind and solar in combine

  • @charlestoniwuagwu3787
    @charlestoniwuagwu378729 күн бұрын

    Great Job and awesome information. How may I reach out to you. Be safe

  • @Theedotalkshow

    @Theedotalkshow

    29 күн бұрын

    @Charles. His numbers are displayed at the bottom of the screen

  • @bencoinstitute
    @bencoinstitute24 күн бұрын

    This is mis information shaa

  • @user-mm4my3po4u
    @user-mm4my3po4u16 күн бұрын

    Ordinary 17.5KWH battery, this boy de lie sha. I use 2 x 17.5 and 30 550 panels for 4 beds duplex and I cannot on all the AC's. You guys should take this video down.

  • @jesuslover1896
    @jesuslover18967 күн бұрын

    Lol. Ignorance is a bad thing. I have 15kW panels paired with 54 kWh of batteries. This system is nothing, and keep in mind it's all about load. No way this is running ACs. Probably just lights and fans.

  • @IjeomaVictor.N-ld7nn
    @IjeomaVictor.N-ld7nn10 күн бұрын

    Baba why na😂😂

  • @bitlebron8801
    @bitlebron880128 күн бұрын

    What about AC's in the hotel rooms?

  • @GTdontDOthat

    @GTdontDOthat

    26 күн бұрын

    dis can't power all d ac

  • @kenazuka7521
    @kenazuka752112 күн бұрын

    😂😂😂😂... Depending on wetin de inside those 38 rooms oh.. maybe just 38 fans and 38 10watt lights bulbs and maybe 8 fans. E non go carry 38 ACs oh

  • @musajarjusey6132
    @musajarjusey61323 күн бұрын

    My friend this not possible,can power not more that 2hs.

  • @adewumisesan26
    @adewumisesan2624 күн бұрын

    Ole

  • @oliverndubizu4360
    @oliverndubizu436023 күн бұрын

    A just watching movie

  • @Tonyben1
    @Tonyben1Ай бұрын

    Them will bill you so that ur mind nor dey again

  • @FTaiwo1
    @FTaiwo116 күн бұрын

    How many air conditioners can this power and for how long?

  • @oladejosolomon2186

    @oladejosolomon2186

    12 сағат бұрын

    It depends on the ac horse power and if its inveter ac then that even better.

  • @EGBEAlpha
    @EGBEAlpha25 күн бұрын

    🤣🤣🤣🤣 everyone they do solar believe at Ur own risk is lies 32room how many watts per room big lies

  • @GTdontDOthat

    @GTdontDOthat

    22 күн бұрын

    only my house dey us 20wh not to talk of hotel

  • @GTdontDOthat

    @GTdontDOthat

    21 күн бұрын

    many will surely believe

  • @nedeosaretin4064
    @nedeosaretin406411 күн бұрын

    I don’t think this boy is an installer or he’s new to the business and wants to mislead potential inverters owners.

  • @engineervictorakpoghene9637
    @engineervictorakpoghene963721 күн бұрын

    Why promote something like this.... Every single talk Na nonsense 🤦‍♂️🤦‍♂️🤦‍♂️🤦‍♂️🤦‍♂️

  • @enyichukwudi1026
    @enyichukwudi102624 күн бұрын

    Pure lie. Una no dey ever talk true

  • @GTdontDOthat

    @GTdontDOthat

    22 күн бұрын

    if he say na only for day time we for believe small if dem remove some load

  • @titochineke1236
    @titochineke123625 күн бұрын

    You dey whine for 32 hotels. Unbelievable

  • @CovenantChisom
    @CovenantChisom20 күн бұрын

    Is better for me to buy a 350kva soundproof than this solar system,350kva can power all the 32rooms and everything.

  • @imonikhebraimoh7191
    @imonikhebraimoh719111 күн бұрын

    as a solar installer, this is complete deceitful. First off, low customer patronage is causing load consumption to be minimum. Technically, if each room consumes just 200W, and all rooms consume that, power consumption= 6400w. then how long will that battery last? Also, the controller looks like an 80W controller which means max. solar power is about 3840W. what he is saying is incoherent.

  • @urchman7475
    @urchman747526 күн бұрын

    Solar is the best way

  • @BB_KUMBO
    @BB_KUMBO8 күн бұрын

    220AH tabular battery = 2.64 KWH x 7 = 18.48 KWH. Do the math and compare it to what he is saying. No one is doubting the quality of lithium ion battery but say 17.5 KWh is equivalent to 15 tabular batteries is a big lie

  • @Martinmartin-ix2cq
    @Martinmartin-ix2cq6 күн бұрын

    His explanation is wrong 😂

  • @Tonyben1
    @Tonyben1Ай бұрын

    If you call them na their will not attend to you probably

  • @Engineerizo
    @Engineerizo14 күн бұрын

    This guy is here to make video but me as an Engineer he should not deceive people around YES SOLAR IS GOOD BUT DO THE Math 17500x80% D. O.D Depth of discharge=14,000w Divide 14,000w by 12hr example of full run time =1166.6w/hr Divide 1166.6W/HR by 32 rooms that is avarage of 36.45625 w/hr for each room Do you think this is true each room can consume approximately 37W for 1 hr NO THAT'S A LIE 🛑

  • @electrowashyelect9715
    @electrowashyelect9715Күн бұрын

    Not serious u are just talking about 300ah x 4pcs of 12volts battery for lithium batteries. A 240ah 12v x4 pcs or 5 pcs or 150ah x 8pcs is still not bad ad equivalents ,but you have over promised what can not be achieved. Sorry for ur self if anybody does copycat of this poor design and over promised.

  • @beejsplacegamesloungelagos5157
    @beejsplacegamesloungelagos515727 күн бұрын

    So much misinformation in one vid

  • @GTdontDOthat

    @GTdontDOthat

    27 күн бұрын

    maybe they fail to inform us that this is only for day time wen d solar panel is producing but it can never power d hotel at night

  • @charlesekpima8210

    @charlesekpima8210

    25 күн бұрын

    It can not power the hotel even in day time with AC or water heater ​@@GTdontDOthat

  • @tvbela2023
    @tvbela20234 сағат бұрын

    Oga Where did you learn your Solar power installation .If you only know about led acid and gel Batteries limit your self to that please . Do not talk about Lithium batteries if you do not know what you are talking about . Do not mislead innocent people please .

  • @Oliviakitchen2023
    @Oliviakitchen20239 күн бұрын

    Pls , am installer always tell the truth when it comes to solar installation. What you are saying is not correct. I jave use 25kwh felicity battery up to 6pcs giving us 150kwh backup. Pls stop telling lies on solar installation. It works not the way you are saying.

  • @waliumoshood9405

    @waliumoshood9405

    Күн бұрын

    Don't mind the guy. Na so Dem go put people for problem after investing so much resources into the project.

  • @ogidz-xix
    @ogidz-xix7 күн бұрын

    Another Click bait video. I stopped watching after a minute

  • @abdulhalimibrahim4826
    @abdulhalimibrahim48266 күн бұрын

    This Man is LYING I SWEAR, this Lithium Phosphate has the power of only 7 tubular batteries, The Inverters on the wall are 10KVA inverters, how can 20KVA be enough for at least 38 pieces of 1HP ACs? miserable liars. and how can these small breakers and changeover be enough for 38 hotel rooms? fear God my brother.

  • @samgongelectronics3761
    @samgongelectronics376122 күн бұрын

    I am an electrical engineer from Cameroon system of 500-watt of 14 solar panels can supply: -Total DC Power = 7000 watts - Total AC Power = 6300 watts (considering 90% inverter efficiency) -Daily Energy Production = 25.2 kWh to 37.8 kWh (depending on 4 to 6 peak sunlight hours) They can support a continuous AC load of up to 6300 watts under optimal conditions. I think you should be talking more about power consumption in DC using LED lights bulbs of between 5w to 15w each. your system cannot support More than 4 air-conditioners of 1.5Kw each.

  • @GTdontDOthat

    @GTdontDOthat

    21 күн бұрын

    solar panel will never produce their rating.a 500watt will never produce up to 500watt