Hot Redundant PLC (Siemens S7-417-5H) Hardware Configuration
Ғылым және технология
In this video you can learn how to make a Hot redundant PLC system using Siemens PLC , It can automatically change over when fault comes in any CPU without stopping process . IM is also redundant in this configuration so that any fault in a single master BUS or IM will not effect the process , Data will be transfer with another IM to another CPU .
Пікірлер: 42
this video has cleared a lot of doubts of mine , You have explained it vey clearly . I become fan of your's immense Knowledge. You have a huge knowledge on Automation system . Thank u for sharing your knowledge .
Thanks a ton sir for making such a beautiful video on my request .
Thank you so much Sir ! I understand how to configure the simatic S7400h for redundancy
thank you so much🥰
Thanks a lot Bhai
i am getting error the module can be inserted only in the rack 0
Thanks sir
S7 400 working, composed bare me bata ea sir
Sir , Why the same hardware is not showing in TIA Portal is it not available in TIA ? can we open a project made with TIa in simatic manager
@engineeringwithengineers6123
4 жыл бұрын
Catalog is not same for both . All PLC models are till now not available in TIA . S7 simatic manager based program can be migrate in TIA but the program must with the controller matches with TIA catalog
good
thanks for the video.. how about programming writing? do we need to download on both CPUs?
@engineeringwithengineers6123
Жыл бұрын
No , just download in any CPU it will automatically sink
@syafawichealuwai243
Жыл бұрын
@@engineeringwithengineers6123 thanks
Which version of simatic manager did u used
@engineeringwithengineers6123
4 ай бұрын
5.6
Dear sir Please let me know Once came PLC CPU solo Mode it can come automatically run mode ? or we need to switch from stop to run mode? (PLC CPU 417)
@engineeringwithengineers6123
8 ай бұрын
No need to switch manually
without download any OB on how you make the system healthy. I am trying it on s7-412 5H failed
@engineeringwithengineers6123
3 жыл бұрын
Can’t get you , in case of step 7 you must have to download OB’s to execute program
I am using 412-5H redundancy system with et 200 sp Im module on profinet communication, but my IM module is not taking IP address what is problem?
@engineeringwithengineers6123
2 ай бұрын
Try to configure directly IM without CPU communication
Hi! I am getting an error. While adding CPU 417-5 H, the H-sync dialogue box is not opening. And later, when I am trying to add 2nd CPU to Rack 1, it is showing only allowed in rack 0. Can you tell me what is the problem? Can the H-sync config be done any other way?
@engineeringwithengineers6123
Жыл бұрын
Please insert H Station not 400 Station when inserting project
@saradendukarmakar5052
Жыл бұрын
@@engineeringwithengineers6123 Oh Yes! Thanks... Yeah I had only added 400 station.
Need help on how to install wincc on windows 7
@engineeringwithengineers6123
Жыл бұрын
sure , mail me
Can you make video on siemens IPC hot backup
@engineeringwithengineers6123
2 жыл бұрын
Use Simatic image creater tool
Are boss vedio thoda clear audio ke satha banaye..
@engineeringwithengineers6123
2 жыл бұрын
Ya , sorry for the problem .
Sir you provide paid online training.
@engineeringwithengineers6123
Жыл бұрын
Mail me ,will try
Sir if possible kindly share your Mail id where we can send our doubts .
@engineeringwithengineers6123
4 жыл бұрын
engineeringwithengineers@gmail.com
@srkumar5199
4 жыл бұрын
thank u sir
@arunjena9432
3 жыл бұрын
My problem is Y link one IM module all indication like SF , Busf1 and busf2 flashing continues plz give me any suggestions.
Thank you bhai
@engineeringwithengineers6123
2 жыл бұрын
Wellcome
i am getting error the module can be inserted only in the rack 0
@engineeringwithengineers6123
3 жыл бұрын
In which case it’s showing ? On which PLC ?