Honeywell Smart Valve Testing-Workbench Series

Ойын-сауық

Welcome to the workbench series. Today we will dive into the Honeywell Smart-valve 1st generation. We will discuss the operation and connection to the Indoor Fan Control (IFC). The 4 wire connector between the valve and the board provides 24V power to the valve, provides a 24v signal to the valve when the pressure switch closes, then supplies a 24V signal back to the IFC on the Electronic Fan Timer (EFT) wire once flame is proven.

Пікірлер: 3

  • @jaymz0074
    @jaymz0074 Жыл бұрын

    Awesome video

  • @escogroup

    @escogroup

    Жыл бұрын

    Thanks James!

  • @ejosephsimon
    @ejosephsimon8 ай бұрын

    Question I have a Honeywell SV9501M2528 if I put the IGNITION SYSTEM CONTROL SWITCH to the off position my hot surface ignitor lights up but of course pilot & burner do not light, the switch being off prevents that, But then when I switch it to on inductor fan kicks on but hot surface ignitor never starts glowing? Is my Smart valve bad or could it be something else? thanks..