Grounding and Bonding in the ham shack

Noise reduction and RFI grounding in shack always adhere to your own countries regulations.

Пікірлер: 29

  • @johnm0csn
    @johnm0csn Жыл бұрын

    Gotta love these videos...no fancy schnazzle just a normal operator's shack shown how people want to see it 👍👍

  • @hamradiostationg0dtx583

    @hamradiostationg0dtx583

    Жыл бұрын

    very nice

  • @MrMesospheric
    @MrMesospheric Жыл бұрын

    I presume the yellow/green wire is your connection to an external earth rod. If so, and you have a PME domestic supply (very many in the UK do) but no heavy-duty (10mm2 minimum) connection from your earth rod to the consumer unit earth, then this is contrary to the electrical regs and could cause a fire in the event of a neutral break along the supply line. Not only is this bad, it could be ruinous, because the breach of regs may well mean your property insurance would be invalidated. This is a common and serious error and one that even the RSGB have made in print.

  • @g0fvt

    @g0fvt

    11 ай бұрын

    I totally agree, our supply is TN-CS to the house and this is a potential problem (no pun intended). There are workarounds where you can legally use a different scheme for an isolated room but with some stipulations. Unfortunately much of the advice on the internet is from the USA where physics works the same but wiring regulations are different. I suspect that many UK installations are wrong, and I must confess to not being above criticism...

  • @GateKommand
    @GateKommand Жыл бұрын

    Interesting and informative thanks mate.

  • @hamradiostationg0dtx583

    @hamradiostationg0dtx583

    Жыл бұрын

    Glad you enjoyed it

  • @davidorme5579
    @davidorme5579 Жыл бұрын

    great video again john

  • @hamradiostationg0dtx583

    @hamradiostationg0dtx583

    Жыл бұрын

    Thanks for watching

  • @superconductorchip9072
    @superconductorchip9072 Жыл бұрын

    Plenty of ground loops, good if you want to cause interference..

  • @hamradiostation_M0UGE
    @hamradiostation_M0UGE Жыл бұрын

    Just a heads up...This seriously needs to be bonded back to the consumer unit if you're on a PME system...

  • @hamradiostationg0dtx583

    @hamradiostationg0dtx583

    Жыл бұрын

    Thanks for info

  • @hamradiostation_M0UGE

    @hamradiostation_M0UGE

    Жыл бұрын

    @@hamradiostationg0dtx583 Not trying to be "Mr Know it all" here, Ian (GM3SEK) gives some solid, sound advice on this topic at an RSGB convention, video link here - kzread.info/dash/bejne/foeAk8pvfa3Ikaw.html 73 M0UGE

  • @hamradiostationg0dtx583

    @hamradiostationg0dtx583

    Жыл бұрын

    @@hamradiostation_M0UGE THANKS WILL HAVE A LOOK

  • @butchdingle1000
    @butchdingle1000Ай бұрын

    Where did you get that buzz bar John will get one when I change coax for this M&P extraflex bury 10 stuff great video 73 DZH

  • @hamradiostationg0dtx583

    @hamradiostationg0dtx583

    Ай бұрын

    www.dxengineering.com/parts/ero-egba14210jf

  • @hamradiostationg0dtx583

    @hamradiostationg0dtx583

    Ай бұрын

    ERICO Copper Grounding Bars provide proper bonding; essential to create an equipotential plane between service grounds and shack equipment. This equipotential plane provides a near-zero voltage differential and serves to protect people and equipment during transient and electrical-fault events. These ERICO grounding bars have a series of 0.281 in. diameter holes that accommodate mounting many items, including Alpha Delta, PolyPhaser, and other surge-protection devices. They include stand-off mounts that deliver extreme isolation from the mounting surface. When used in tandem with ERICO ground rods and ERICO CADWELD ONE SHOT Wire to Ground Rod Clamps, there is no better grounding system available… period! These ground bars have a 1-1/16 in. standoff of their stainless mounting brackets plus a 1-1/2 in. insulator. This places the inside of the ground bar more than 2-1/2 inches from the mounting surface. There's plenty of room to work after mounting the bar. These bars may be mounted horizontally or vertically and the mounting holes in the copper bar are 8-7/8 in. on center. These grounding bars provide a convenient, reliable grounding location. Their quarter-inch thick solid-copper bar represents the ultimate in ground connections. ERICO grounding bars include insulators, stainless steel brackets, stainless steel mounting bolts, and are UL Listed. For premier grounding at your station, rely on ERICO Copper Grounding Bars from DX Engineering.

  • @johngulliver6151
    @johngulliver6151 Жыл бұрын

    Where did you get the braided earth strap I could do with some of that cheers great video thanks for posting

  • @hamradiostationg0dtx583

    @hamradiostationg0dtx583

    Жыл бұрын

    DX engineering john

  • @zaperfan

    @zaperfan

    Жыл бұрын

    @@hamradiostationg0dtx583 Thank you. Great setup you have cheers

  • @robertbest6863
    @robertbest6863 Жыл бұрын

    Hi this is M1DAT Rob, was wandering were you got your braid and ring connector and how much. Look forward to hearing from you, many thanks.

  • @hamradiostationg0dtx583

    @hamradiostationg0dtx583

    Жыл бұрын

    dx engineering i can not remeber the cost

  • @user-nq4wo7ti8i
    @user-nq4wo7ti8i Жыл бұрын

    OH good from HL5 call 73!!

  • @hamradiostationg0dtx583

    @hamradiostationg0dtx583

    Жыл бұрын

    Thanks 73

  • @mauricewilkes826
    @mauricewilkes826 Жыл бұрын

    Looks a bit overkill. How effective is rf grounding when your shack is on the first floor?

  • @hamradiostationg0dtx583

    @hamradiostationg0dtx583

    Жыл бұрын

    No rf in the shack happy days 73

  • @johnratcliffe6438
    @johnratcliffe64389 ай бұрын

    I don't bother with grounding. My world hasnt ended.

  • @LAFD54
    @LAFD547 ай бұрын

    If you would use a balanced dipole antenna, you wouldn't need all those ridiculous magnets and straps!

  • @hamradiostationg0dtx583

    @hamradiostationg0dtx583

    7 ай бұрын

    it's for noise coming from the neighbours not rf its for qrm on the coax.

  • @LAFD54

    @LAFD54

    7 ай бұрын

    LOL! @@hamradiostationg0dtx583