Gibson Furnace Won't Stay On (Repair and Parts List)

Тәжірибелік нұсқаулар және стиль

Is your Gibson furnace not staying on or repeatedly turning on and off? The flame sensor or the control board might need to be replaced. The control boards on this Gibson model (# KG7S 072C-24B1) commonly develop cracks in the solder joins causing the board to fail. Below are the part numbers for these two parts.
Gibson Furnace Model # KG7SA 072C-24B1
Nordyne Flame Sensor # 632484R
www.supplyhouse.com/sh/contro...
Nordyne Circuit Board for G7/M7 # 920915 (substitute part for discontinued control board # 624742 )
www.supplyhouse.com/Nordyne-9...

Пікірлер: 8

  • @chongminwang
    @chongminwang4 ай бұрын

    Thank you very much, Owen. I had the exact problem with my furnace, replacing the flame sensor didn't solve the problem. I just ordered a new sensor you listed and will report back when it is installed. Luckily, temperature has rising in the the spring.

  • @chongminwang

    @chongminwang

    4 ай бұрын

    Just want to report back that I've replaced the control board and, viola! the furnace is running again. I examined the old board and saw no visible broken soldering points.

  • @lizethgarciameza803
    @lizethgarciameza8035 ай бұрын

    You have a diagram How to conected the wiring to the control

  • @jarin12ga
    @jarin12ga6 ай бұрын

    I replaced my circuit board in 2019. So it lasted exactly five years. Well, at least I know what's wrong. Besides this board I love the furnace .

  • @AllanGarde
    @AllanGarde6 ай бұрын

    I am getting Pressure Switch Open Fault. Does the pressure Switch need to be changed?

  • @OwenLucas

    @OwenLucas

    6 ай бұрын

    You should check with an HVAC tech.

  • @hankjones2985

    @hankjones2985

    5 ай бұрын

    It was my board but it wasn't bad just had a loose wire. Now it's all good!!

  • @jaysheat631
    @jaysheat6317 ай бұрын

    just came across one, exact same thing