Electrical|House wiring Earth Leakage Problem|Led Light Glowing Problem|Havells Led Light
Ғылым және технология
Hi friends I'm sonu (technical sonu tech) your most welcome on my KZread channel (Sonu Automation Technology) I'm a electrical & plumbing technician,friends I will upload all types electrical informative videos on this channel each day,so please subscribe and watch complete video starting to the end,for complete information
!
Included topic: electrical installation,three phase power system,pannel installation,electrical saftey devices& electrical mentenance....Commercial & residential
thank-you so much...
About in this video- today we will learn that in this video how to solve electrical earth leakage problem in house wiring,and also more about of electrical installation...
#electricalinstallation
#electricalleakage
#electrician
#housewiring
#ledlights
#havellslight
#electricianlife
#sonuautomationtechnology
@havellsindia
My official plumbing channel link-
My social media links.....
(1)-instaagram link- / technical_sonu_tech
(2)-facebook page- / toolsman555
(3)-twitter- / technicalsonut1
Contact for business inquiry &sponsorship- sonujiautomationtechnology@gmail.com
Пікірлер: 91
वीडियो अच्छी तरह समझ में आया लेकिन बिना पकड़ से वायर ज्वाइंट किया है इनके बारे में डिटेल में प्रेक्टिकल वीडियो बनाय जिनसे shock से बच सके
Phase hamesha socket ke right side me hona chahiye
@sanipti
4 ай бұрын
Right bro
@DanishA-vy3ni
3 ай бұрын
Bilkul
@RavinderDelhipoliceASI
2 ай бұрын
Bhai sha hi kha
@kanhiyalal4449
2 ай бұрын
You are right
@shudhansu2433
Ай бұрын
Phase ko switch se connect kerna hai, Chahe kisi bhi side lagao
Super electrician kaha se ho vaiya इ होता है electrician man
Y problem mujhe bhi aai h thanks bhai jankari Dene ke liye
Kya electrician banega bhai..
Nice 👍👍👍
Nice bro
@SonuAutomationTechnology
5 ай бұрын
Thanks
Nutral socket ke right par kiu hai ?
Good
Bhaiya mera double phase karne pe dono socket ke hole line aata hai Q
Thanks. In my house phase and neutral wires are correctly connected. Even though 5 watts are glowing lightly even after switch off condition. Please give solution early.
@glocklock2828
2 ай бұрын
there must be some issue with the neutral if u have check it with the meters and neutral is ok ..then first check ur board from u r operating the LED bulbs..check it with the multi meter...put one side on the ground (Earth) other on the neutral ..if its showing the voltage..it means u have leakage problem there .if its ok then check ur led lights
Prnam sirr ji g evng
👍
Thnks bro
Think you
Sir neutral pe v load hota h , circuit tavi toh complete hota h na
App men ghumaya isika asar invoter me sahi rahega ya use chenj karna padega
Sir MCB box ka hight jeada up hai shyd repair krte time me problem aa sakta hae
Bhai face bhi sahi hai Nurul bhi sahi hai aur inverter bhi sahi he fir balb halka halka jalraha he😢😢 bahut problem he please koi solution bataiye
Good message thank you bro
Hello sonu bhai un se pucheiye dressing krna kaha sikha h Rajat ke pas
Mere sath v ayi ye problem par Sonu Bhai mere case me phase or natural dono sahi h but fir v led fir v glow hora h
Sir Rccb ke bare me puri jankari dijiye kese Kam karta hai kha lagaya jata hai
Phase ki jagah neutral aur neutral ki jagah phase isliye hota hai kyunki house wiring complete ho jane ke baad use check karne ke liye ki sab kuchh sahi to hai temporary mein connection kiya jata hai vo bhi ek hi colour ke wire se jiske karan ye problem hoti hain , agar colour coding ke hisab se connection kiya jaye ya ek hi colour ke wire mein phase, neutral ko check karke conection kiya jaye to ye problem nahin hongi.
@villageboysk952
5 ай бұрын
Shi baat mere sath v hua tha ek jb connection shi kiye phase ko phase or net ko neutral m to shi chla
@sunilsain8063
3 ай бұрын
Canaction sahi ho to bhi ya fault aata hai
@BHUVAN....
3 ай бұрын
@@sunilsain8063 han , shayad pole se aisa ho sakta hai, phase ki jagah neutral aur neutral ki jagah phase 🙂.
@pritamkumar-kc6tn
12 күн бұрын
Same problem mere sath bhi hua hai @@sunilsain8063
Sonu bhaiya hamara phase netural earthing sab kuchh sahi hai phir bhi kuch company ka bulb 💡 halka glow hota hai or kuch company ka bulb 💡 sahi jalta hai, solution please bhaiya
@rameshray49
4 ай бұрын
Ha Sonu bataya
Nice video 💖
Neutral face sab karke dekh liya fir bhi jale ja Raha hai. Plz ek solution. Satish Sharma Nangli
@manojparjapat1224
6 күн бұрын
Bhai यही मेरी साइड प्रॉब्लम ह क्या करे बताओ ना
Same problam mere sath
Very good
Socket me pahila wala he o phase hona chahiye kisne kiya ye wiring😂
न्यूट्रल फेस का कनेक्शन सही नहीं होंगे
Bhai mri phase nutrule tik h pr door bell 10 10 mint bad baj ri h mko rply kre
Pace socket ke right side mein hona chahie
Aapse baat ho sakti hai kya bhai
Socket me pahila wala he o phase hona chahiye kisne kiya ye wiring
Pase hamaisha soket ki right side pa hota ha
2 second ke kam ke liye 15 minut😂😂😂😂😂
Thank you sar
Ye bahut hi normal problem h😅
Matlab phase control main hona chahiye
2nd floor flat me earthing kese kre ?
Neatrul our phase change kro
Aake hm se shikh lijiye sonu bhai
@SonuAutomationTechnology
5 ай бұрын
Video aapne pura dekha kya? Maine fault ko sahi kiya hai,sikhaya hai bataya hai understand! Anyway thanks
@ranjanelectricalvlog6013
5 ай бұрын
Bhi hame sikha do kidr ana hai
8:48 😢 कैसे काम करते हो सर कभी भी लोड ज्यादा न्यूट्रल पर ही पड़ता है आपने नोटिस किया होगा घर में लाइन ब्रेक होती है तो न्यूट्रल ही ज्यादा तर जला रहता है
Umesh bhai ko conection nhi aata hai
ऐसी समस्या हमारे बिल्डिंग में भी हे जो जो इसके विपरीत है हमारा बिल्डिंग में एक स्विच बोर्ड है जिसमें चार स्विच है 1234(1बल्ब का जो स्विच है उस लाइट बंद चालू होती लेकिन स्विच 1 बंद कर दिया हेऔर बोर्ड के अन्य स्विच 3चालू किया तो बल्ब 1 हल्का सा ग्लो कर रहा है (मतलब ये h की अन्य स्विच चालू करने पर बल्ब 1 ग्लू kr rha हे) हमने मीटर से फेस वह न्यूट्रल भी चेंज कर लिया है सॉल्यूशन nhi हुआ
Neutral cut hua h phase nahi
Sir mere ghar me only 2way ke switch mai hi halka halka 9w bulb chalu rahta hai switch off hai fir bhi
@Preetjattii7903
4 күн бұрын
Hamare bi yhi problem hai bhai
ये प्रोब्लम मेरे घर में भी ही मैने वायर को चेंज भी कर लिया फिर भी ये प्रोब्लम सही नही हो रही है प्लीज सॉल्व्ड my problem
Niotal mi karant hai
Bhai Mera wairing me 3 room main 3 led halka glow ho raha hain,,,, baki sab thik hain,,phase neutral Arth sahi se laga,,,Denag khrap ho raha hain please help bhai,,,
@rksjgdm2511
4 минут бұрын
Mera bhi yahi hal h
Rccb laga ho to bhi kya n f
Is KO phase nutal kaha LA gate no maloom😂😂😂😂. Moo utake agaya phase phase left me tester lagake
उस्को pahse jodne nahi atta to electrician kisa😂
Phase neutral sahi hone par bhi ye problem aata hi hai
@rameshray49
4 ай бұрын
Hamare sath bhi esa hi huwa h jawab dijiye ji Sonu bhai
ulta paida hua h kya bhai right side m phase aata hai
Kaniksan galat hai immediately me
न्यूटन सप्लाई नहीं
3:41 कौन से इलेक्ट्रीशियन हो कभी भी पेज कनेक्शन राइट साइड में किया जाता है और न्यूट्रल लेफ्ट साइड में किया जाता है नियम तुम्हें खुद ही नहीं पता है तो क्या तुम प्रॉब्लम सॉल्व करोगे
Bolneka..style chenge hua...chuta bath hote rahethahe
Ek hi problem hosakta hai
Acha dressing. 😂😂😂😂 kissikobhi no aga aap ko hi ayahai
Song ji apna mob. No. De pls , abhi kis city me hai
Le timepass
Board mein Jo sokit laga hai usme connection bhi shi nhi kar rakkha hai line ka neutral kar rakkha hai Neutral ka line Pahle connection karna seekh lo Tabhi video banakar sbko Gyan do Galat Gyan mat do Kam se Kam 3pin top ke neecche Wale do pin ko dekh lo Line kis side hai or Neutral kis side hai Vaha likha hota hai L N Fir dekho ki Sockit mein Line connection kis side hota hai or Neutral connection kis side hota hai Jb aapse connection karne theek se nhi aate hai to video banakar galat Gyan mat do
À
यही बात , 3.4 मिनट के वीडियो में भी तो बताई जा सकती थी 😂
Tum plamber ho ki eletricin jankari jhat bhat aur kaam raat bhar
@Jahidali00086
5 ай бұрын
Do no he
Led blub does not require Earthing Cleare your decision This is called reverse current , coming in switch wire because neutral is directly connected to the bulb , in this case blub needs phase supply for glowing , but the switch is off, in this position any phase wire is leaking current , that goes to catch switch wire and your blub dim glowing and also may be wrongly inter connected main supply or wiring
Kisi ne wiring ulti ki hui hai
Wire leakage hoga
Bhai kobalt ka online nahi mil rah h rotary hemar powertax ka 900watt kesa h