How much Voltage is needed between Earth and Neutral | Electrical Wireman | Electricals in Hindi
For online courses call: 9768871110
Share, Support, Subscribe!!!
Main KZread channel : / niketshahpluspoint
Click for membership : / @niketshahplus
Online Courses Android App: play.google.co...
Telegram : t.me/niketshah...
Twitter: / niketshahplus
Facebook: / pluspointtraining
Facebook Myself: / niketshahkalyan
Instagram: / pluspointtraining
For Online Courses Website: www.pluspointo...
Email: niketshah.pluspoint@gmail.com
WhatsApp: +91 9768871110
Online Courses also Available For more details Just call us on : 9768871110..
About : Niket Shah Plus is a KZread Channel, where you will find technological videos in Hindi, Technology video on Electronics, Electrical, Computer Hardware Training, Laptop Repairing, Mobile Repairing, Circuit making, Computer Engineering Software Courses like AutoCAD, Animation, Video & Sound Editing, 3D animation, Microsoft Courses, Accounting Software and Many More.. Etc.. All In Hindi... thankx.. :)
Пікірлер: 563
Sudhir Shah's comment is right. It is observed that due to loose connection at neutral point somewhere either in your house or main supply source, there will be higher than 10 - 15 volt between Neutral to Earth. This condition of supply line should be taken care of, otherwise higher the voltage between Neutral and Earth can lead to damage to sensitive electronic equipment and shock hazards to the equipment user.
@bakhshishsingh3165
Жыл бұрын
V good
@safuddinsardharwalla980
Жыл бұрын
Thank u sir
The ideal Voltage between Neutral and Earth should always be " 0 " . It should never be more than 5 volts. But to confirm that, Earth connection is in a proper working condition, the Voltage reading between Phase and Earth should be 5 to 10 volts less than voltage between Phase and neutral. If there is " 0 " voltage between Neutral to Earth as well as between Phase to Earth, then it is understood that, Earth connection is either disconnected or not provided to that point.
@sumansaha295
Жыл бұрын
If the voltage between earth and neutral is exactly zero and the continuity test is beeping when tested with multimeter, does it mean they are shorted?
@tahirakram2783
10 ай бұрын
yes it is interesting aspect, but seems to be correct. I think one point why the voltage between neutral and earth appears which is due to unbalanced load on three phases from the distribution transformer. This reason has not been highlighted.
@mr.bhupendra24
7 ай бұрын
Phase to Earth 220v and Phase to Neutral 220v ac. Neutral to Earth 2 to 3 volts, Neutral to Ground 0v ac.
Very nicely described and in an easy way it is a mix of theory and practical...hearty congrates sirjee
अच्छी जानकारी दी आपने गुरुजी धन्यवाद
Very good perfect explanation regarding neutral and earth
@NiketShahPlus
3 күн бұрын
Thanks a lot.. do share this video with your family and friends also
I think it is correct to have voltage between earth and neutral around 3 to 5 volts, according to me, if there is more voltage than that, then there may be a fault in some device of the house.
सुपर सर जी , आप बहुत अच्छी तरह से समझाते हैं।❤
One more very important and reason should have been mentioned here which is happening majority time rather than other reasons. Sometime the neutral from the power company creates such problems in neutral level increases due to some fault there, but resolves on its on. During such period you get about 20 to 30 voltas between neutral and Earth. Please comment 🙏
@gunjansharma1918
Жыл бұрын
yes u r right the busbar they r using is only for phase and neutral, no proper earth is done
@AwaisAli457
19 күн бұрын
I do have same.issue . Neutral from main supply from government is giving 80 volts . How to solve ?
Perfect balance of explanation
Apki saari baaton se hm sehmat hain👍
@NiketShahPlus
15 күн бұрын
Aapke vicharon ke liye dhanyavaad! Agar aapke paas koi aur sawal ya madad ki zaroorat ho, toh zaroor bataiye. Main yahan hoon madad ke liye! and do share this video with other also
Good Informative Video. 👍👌
Perfect explanation
आपण खरोखरच फारच अनुभवी तज्ञ आहात.
Good and infomative tech video.
@NiketShahPlus
Ай бұрын
Glad you liked it!.. do share this video with others also
Excellent video 👍
@NiketShahPlus
11 күн бұрын
Thank you very much! do share this video with others..
Good information 👍 ❤
@NiketShahPlus
3 күн бұрын
Thanks for liking. do share this video with others
अगदी नविन माहिती ऐ कायला मिळाली आपला फारच आभारी आहे.
Thanks
Sir ji aapka explained karne ka tarika laajawaab hain 😊👍🙏
Nice explanation.
@NiketShahPlus
2 ай бұрын
Glad you liked it do share this video with your friends and others
Thankyou sir
Nutral aur phase कि wire एक ही gauge की लगणा चाहिए ये आज मैने पहिली बार सूना. And auther information is very nice Thanks
@NiketShahPlus
4 ай бұрын
Do share with your friends
Nice video sir thanks.
@NiketShahPlus
2 ай бұрын
Nice.. do share this video with your friends
atisundar hai apke batane ka trika ..dhanywad..
सुंदर माहिती आहे धन्यवाद
@NiketShahPlus
3 ай бұрын
Thank you
Very clear tutorial. Thank you
बहोत बढ़िया जानकारी दी आपने घर की वायरिंग में voltage leakage कैसे ढूंढे
@NiketShahPlus
4 ай бұрын
New video ane wala he soon ..
NICE VIDEO SIR.
@NiketShahPlus
2 ай бұрын
Thanks and welcome do share with your friends and others
Simple way to describe... superbbbbbb 👍👍👍 i like it
Sir mere ghar me jab mene earthing check kiya toh Phase+Nutral=228v dikha raha tha Phase+Earth=227v Aur Nutral+Earth=8v dikha raha tha Sir aap please bataiye ye neutral to earth jo 8v aaya he ye sahi he ya galat ....please bataiye aur agar galat he to ise sahi kese kiya jaye please bataiye
Very informative briefing. 👍👍👍
@NiketShahPlus
4 ай бұрын
Glad it was helpful!do share with your friends
Bahut accha aap ne sikhaya sir
Mujhe bahut pasand aaya sir ji
Good information. Thanks
Very good sir
@NiketShahPlus
3 ай бұрын
Keep watching and do share with your friends this video
Very nice
@NiketShahPlus
4 күн бұрын
thankx.. do share this video with others also
Very crystal clear information
Lot's of thanks Sirji, For the valuable information about the voltage between Earth &Natural and also proper voltage mension in the house....
@NiketShahPlus
Жыл бұрын
So nice of you
Superb performance excellent explanation
@NiketShahPlus
5 ай бұрын
Thank you so much 🙂 do share with your friends
Good knowledge
@NiketShahPlus
4 ай бұрын
So nice of you do share with your friends
Sir apki video bahut achhi lgi
This is very useful and important video🎥 thanks sir
@NiketShahPlus
Жыл бұрын
So nice of you
Less than 5 V hona chahiye
Very nice bro , very useful
Bahut badhiya video
Good explanation.
Very use full knowledge
बहोत खूब ❤
@NiketShahPlus
2 ай бұрын
Thank you.. do share this video with others
electronic equipment and server room Switched 2v is very necessary
@user-nt9zq9sq8r
11 ай бұрын
0 volt
Very good teaching sir. Thank you very much.🙏
very good. Well explained. Thank you sir
Thanks bro; it was really helpful
Sahi jankari di aapne
It should be greater than 0 but less than 6 VAC
3 to 5 volt between neutral to earth.
Sir ev car charge battery 40 kw karne ke liye kitna solar panel lagega mere pass Nexon ev max hai
Namaste sir Very nice video
@kareemjassani3443
9 ай бұрын
Sir Mere yaha ek new machine ka connection diya hai Electrician ne loop karke neutral diya hai...jisse dusri machine mein body shot AA Raha hai. Kuch solution dijiye sir. . Thank you 🙏
Very Very good sir thank you sir
@NiketShahPlus
7 ай бұрын
Most welcome
Video achhe hain ...
I have made new earthing at home because the old one is showing more than 230volt between nutral to earth at all the points. Now, the neutral to earth is between 16v to 22 volt at all points. No appliances are damaged or malfunction. How to resolve the more voltage between neutral to earth. Wiring done by builder looks poor, and almost all points were loose connections. And seems extended neutral wire from main point. Some. Do suggest the best way to solve the problem. Thanks
@NiketShahPlus
3 ай бұрын
First check the load on neutral.. make proper bus bar as well as if possible implement RCCB.. upto 10v is also ok between neutral and earth
Nice ❤
@NiketShahPlus
Ай бұрын
Thanks 🔥 do share this video with others
Kya baat h sir maja aa gya...
Neutral to earth not to zero, less than one volt, in case voltmeter select should adjust, neutral resistance less than one Ohm. As per the electrical engineering.
Lovely Video ❤
Very nice sir🙏
Good suggestion
Namasthe sar, your teach very good 👍.
Thanks. Very well explained.
सर आपने बहुत ही बढ़िया तरीके से समझाया बहुत बहुत धन्यवाद।
Good work ❤❤❤❤
@NiketShahPlus
4 ай бұрын
Thanks ✌️do share with your friends
Good one sir
Thanks for sharing
Very good
Sir thankyou for your information
Good information sir
Nice
Fantastic explanation. Can u please tell us the correct earthing wire sizes for airconditioners and other appliances like geyser, iron box etc / bulb, fan etc
@NiketShahPlus
6 ай бұрын
Will try to make video on this
Great Video but you must point out that this is only good for India, as it's wiring is spur for each room for sockets in UK and may be in Europe the Socket wiring is ring mains wiring and it uses 2.5mm wire for Live & Neutral and 1mm for Earth wire
Zero volt sahi answer hai
@NiketShahPlus
Жыл бұрын
Nahi
Sahi hai Boss
How to organise Newtral bus as you said Netral is overloaded
धन्यवाद 🙏
@NiketShahPlus
2 ай бұрын
Welcome.. do share this video with others also
Helloo sir Mera ghar village area mei hey ...high hill mei parta hey .....udar weather mei bahut kharb hota hey lightning thandar ka problem hey .. ussee bachna kunsa earthing thik rahey ga?
The best 👍
Nice sir
@NiketShahPlus
5 ай бұрын
Thanks and welcome
सर बेस्ट नौलैज ❤👆👌👌
Sometimes wireman conect Neutral and Earth to save wire and cheat. How to detect and rectify?
@NiketShahPlus
Жыл бұрын
Check eath and neutral voltage
Neutral say ek room por 5 point cunnection k liya ek hi Neutral say hony say kya hoga
Nice video sir 👍
Very good. Ab. Kadar Khan.
Good
Thanks ❤
@NiketShahPlus
4 ай бұрын
You're welcome 😊do share with others
Very nice sir
This video clip is very nice.Ask to one question that if voltage between neutral and earth has more than 3.5 volt,Is it affecting the electrical energy bill.. If it is zero volt, is it affecting electricity bill..?
@Rajendr9651
11 ай бұрын
Yes, affecting, but ,how much ? Twenty eight Paisa per bill.
Dhanyawad sir
Very nice 👍 some douts about Neutral and earthing is clear.. Thank you
Great👍
Thanks dear sir
Anchor ma kon sa Modular Board's Best ha, Rider, Roma Clasic, Roma Plus, Roma urban, for Home.
@kamal2kotabagh
Жыл бұрын
Gret white brand ka switch badiya hota he, Gret white, Anchor brand ka aapas me purana relation he,Google search kar dekhana
Veeri good sar
@NiketShahPlus
4 ай бұрын
Do share with others this video