Continuous Beam Reinforcement according to Curtailment
Welcome To AK Skills And Solutions Channel.
In this video I will show ,how to provide reinforcement in Continuous beam.
.Beams are the horizontal members of a structure which are provided to resist the vertical loads acting on the structure. So in order to maintain the efficiency of a structure, it is necessary to provide the proper size of a beam to resist a given set of loads.
#beams
#Beamanimtion
#animationbeam
#how to animation of Beam?
If you see this video helful, Please "Subscribe", like, comment and share. Thanks you
Пікірлер: 85
Amazing demonstration and simple to understand.
Muito bom, este video é fantastico, muito obrigado por compartilhar conhecimentos com o resto do mundo, muito obrigado.
very nice and best explanation
Superb quality
Good presentation Sir
Good explaination❤
Best explanation on bar bending on KZread so far. I’m glad to discover your channel😂
@akskillssolutions4377
Жыл бұрын
Glad you enjoy it!
@mdmohibbullah8340
Ай бұрын
@@akskillssolutions4377আচ্ছা আমার ছাদ ডিম লম্বায় আছে 66ফিট আর উঃ দক্ষিণে আছে 15 ফিট তো আমি বিমের রট আগে কোন টা বিছাবো
Muy bien, un saludo
Amazing work
@akskillssolutions4377
Жыл бұрын
Thanks a lot 😊
great effort.. weldone
@akskillssolutions4377
Жыл бұрын
Thanks a lot
Amazing video with good illustrations. 👍
@civilengineeringfromgoldme3074
Жыл бұрын
Of course
@akskillssolutions4377
Жыл бұрын
Thank you very much!
Thanks u making me expert engineer
@akskillssolutions4377
Жыл бұрын
It's my pleasure
Sandar
great work , add info ; the stirup of the beam stops at the face of the col
Good enforcement
I find it, Thanks, 🙏
Beam to column is cold-jointed... maybe better if poured at same time (monolithic)?
❤️❤️❤️❤️
Nice
Mast video hai bhai
@akskillssolutions4377
Жыл бұрын
Thanks
🎉🎉🎉🎉
Amazing animations Appreciated
@akskillssolutions4377
Жыл бұрын
Thanks
At support compression is at bottom. where is compression reinforcement. As per SP 34 negative reinforcement at end support L/4. it is OK . But in intermediate support it is also L/4. because point of contraflexure from both the support is 0.211L
How u make such type of videos and which software are you using for making these type of videos .Can you tell me ?
Masha Allah Which software is this
Good
@akskillssolutions4377
Жыл бұрын
Thanks
Sir can both beam main bar stay at outside of column bar?
Sir which app did you use for making it?
Hai, is it correct or not I don't know, Although I just say, Bars available In market upto 12m length, but here you mentioned both column to column 6m distance. So total need length of bar is, 6+6+0.25+0.25+0.2+0.2=12.9. Here, 0.25- column(L), 0.2-(L bending). So there must come lapping. Please check and correct it.
Which softwear?
Can u guide me how is the size of pillar And beam for 3 stories building.
how to make this kind of animation? what app do you use?
Length of steel bar not more than 12 m.here distance between columns shown 6m in the both so how can you put 12m continuos
Clear concrete cover should be atleast 40mm. Correct me if im weong
@jerapornheetchoui9347
Жыл бұрын
พาสสดใสน่าสัมผัสกับธรรมชาติ
Sir combined footing pe video banaye
Nice one . But you should have shown lapping zone for continuous beam .
@akskillssolutions4377
Жыл бұрын
It is placing of reinforcement of continuous beam.this is not overlapping zone.
AD hay ai đó có thể giúp mình biết phần mềm nào thể hiện 3D vậy? Em cảm ơn mọi người!
Just want to ask, what is the Width & Height dimension of the beam?
@akskillssolutions4377
Жыл бұрын
300mm x 450mm
Which software, software name
Sir bottom extra bar is provided in center of beam. Is it right?
@akskillssolutions4377
Жыл бұрын
Yes,it is right.
may i ask the name of the software that you used in this video?
@akskillssolutions4377
Жыл бұрын
Sketch up
In case seismic loading is considered, bottom beam reinforcement will be more at support. Is it right?
Sir please wich software tell me sir
kc sire rod baiding video please
2=14#.mm bar steel
What is the task of bottom extra bar??
@akskillssolutions4377
Жыл бұрын
To resist the tension.
Pls Engr what app did u use
@akskillssolutions4377
Жыл бұрын
Sketchup.Thanks
I don't understand this notation: "2L-8#@200mm" Would someone be so kind as to explain it to me? Thank you!
Hay a
កាយ៉េសរសអត់ដកចេញ😂😂😂
400 mm C/c stirrups spacing are wrong
@akskillssolutions4377
Жыл бұрын
Thanks.writing mistake
সোজা রড ঠিকই আছে,, বাঁকা রডে কি লোড নিবে,,সেতো এমনিতেই লম্বা।
Sir which State from u India
@akskillssolutions4377
Жыл бұрын
From Germany
@dariodario8960
Жыл бұрын
@@akskillssolutions4377 schönen Dank! Greetings from argentina 😅😅😅😅😅😅😅😅😅😅😅😅😅😅😅😅😅😅😅😅😅😅😅😅
@civilengineeringfromgoldme3074
Жыл бұрын
Hahaha
Sir 14 mm ka bar Kain sa kpany bnaraha hai
@akskillssolutions4377
Жыл бұрын
Sorry this is 16 mm not 14 mm.thanks
Slope type
No no no ful
if a beam B1 is connecting to a Col from one side and another beam B2 is connecting from opposite side of col. And both beams details is different B1 has 3 Top continues bars and B2 has 4 Top continous bars how will we provide development length and will B2 continues bars extend into B1 or not plzzzzzzz someone .....
@thoughts7085
Жыл бұрын
Yes extend B2 bars into B1 . Bcz this way it will be more safer
@MAnas-el6cd
Жыл бұрын
@@thoughts7085 to how much length should we extend
@thoughts7085
Жыл бұрын
L/4
@MAnas-el6cd
Жыл бұрын
@@thoughts7085 bro as far as i know Top extra extends by L/3 or L/4 as per mentioned in drawing
@MAnas-el6cd
Жыл бұрын
@@thoughts7085 I'm talking about only top main bars not top extra