This video shows how to curtail reinforcement in beams. It shows that you have not to curtail reinforcement in critical sections where you have maximum bending moment, you are not allowed to curtail bars in that region. The curtailment we do in beams or in slab because to make economical design, where we need no reinforcement to resist bending moment, so we place no steel bar over there.
Our channel brings civil engineering videos for students of Diploma, B-tech, M-tech, Bachelors and Masters.
Subscribe our channel for more civil engineering videos.
Пікірлер: 66
Aapka Har video 100 me se 90 present smjh aata hai Thank you sir civil guru jee ki jay ho
L/3 and L/8 : L is length of column centre to column centre and not column inner to column inner...correct it!!!
Than when we use crank bar? Is same arrangements crank and curtailment bar? Can I replace curtailment to crank bar?
Really nice today is my exam it helped a lot
How decide l/3 and l/8 for extra bars
Thank you sir...nice explaination
Thank u to share very imprtnt knowledge with us👍.
@civilengineering94
4 жыл бұрын
(Y) #Khan
you explained it really simple bro...God bless you
@civilengineering94
4 жыл бұрын
Glad it helped
Curtaiment same Hoti h kya slab ki bhi
Thank you 🙏
Osame yar
super video aur chahie
It was very helpfull thank you brother
@civilengineering94
2 жыл бұрын
Glad it helped
Thank you very much brother for sharing your knowledge. Really appreciated.
@civilengineering94
4 жыл бұрын
Glad it was helpful!
Thanks for good explain.
@civilengineering94
3 жыл бұрын
You're welcome
Sir if l/4 =0.25l ,l/2= 0.5l what is value of 0.15l and 0.3l ?? so I want list of all these values in which code or book I will get all these values plz tell me sir
@FriendTrue2008
Жыл бұрын
L/6.67 = 0.15L L/3.33 = 0.3L
Some beams bottom use l/4 in the beam can u explain where we can use the l/4 or l/8 concept
@wtfplays333
3 ай бұрын
Continuous beam L/3 End beam L/4
How to tie stirrups in the middle if bar not provided?
@civilengineering94
5 жыл бұрын
Ties without bar has no meaning
Good ,I am foreman of steel.
Column ko add nhi kya apne
For continuous beam how
Thanks for information
@civilengineering94
2 жыл бұрын
Welcome
Sir , top extra bar at the end col will be in the shape of L ie ( Ld + length of top extra bar from outer face of col ) Please clarify the matter.
@MAnas-el6cd
Жыл бұрын
Yes you are right development length / Anchorage length must be provided
Nice job sir.
@civilengineering94
2 жыл бұрын
Thank you kindly
Thank you Sir...
@civilengineering94
3 жыл бұрын
Most welcome
Sir why we use curtailment of bars
These are extra bars not main bars. Curtailment done only on end extra and bottom extra bars
Sir one que. Jo. Apne l/3. =13.1 aa gya. Fr column me. Uska L and kitna column k adr rkhna he j to btao na g .
@LivingOnTheEdge123
2 жыл бұрын
Column ka under toh . Dusra main bars ki tarah same development lenghth hoga
@jazzroyal865
10 ай бұрын
@@LivingOnTheEdge123 develpment lenth l/4 +column +develment length RIGHT NA ?? SIR IS CODE K ACCORDING TO DEVELMENT LENTH BHUT BADI HO JATI HAI kya kre g
Continuous nd discontinues side pe same ata hai kya sir
@MAnas-el6cd
Жыл бұрын
For top extra L/4 is used at dis continues side and L/3 at continues side usually
👍👍👍👍
@civilengineering94
4 жыл бұрын
#Raja (Y)
IS कोड क्या क् ह्ता या क्योकि कुछ टॉप बीम मे टॉप बार L/4 तक व बॉटम बार L/6 लेते हे जबकि कुछ लोग L/3 व L/8 lete हे क्या स हि हे
Thanks
@civilengineering94
10 ай бұрын
Welcome
L should be effective length
❤❤❤❤❤
@civilengineering94
6 ай бұрын
Thanks
R u from Pakistan?
Good
@civilengineering94
3 жыл бұрын
Thanks
English subtitles plz
Subject is in English but the procedure is being explained in a different language
@sahilbanyal1232
4 жыл бұрын
Its hindi
@MAnas-el6cd
Жыл бұрын
@@sahilbanyal1232 no it's urdu
Waw how L/3?
If both your title and language are in english, you should also be explaining the subject in english in your video.
.15 L pe curtail
kindly dont provide extra bar at bottom bcz it can collapse bcz of no ductility in bending moment
@MAnas-el6cd
Жыл бұрын
No brother i don't agree with u Becoz bottom extra is provided at bottom centre to resist bending. And is provided in most cases especially in main beams
Video not clear
Seen so many engrs channel but felt very disappointed