3 EPIC High-Rise 2.5m/s ThyssenKrupp Gearless Lifts in NRW, Germany
Ғылым және технология
Timestamps:
0:00 intro
0:26 normal ride
4:37 motor room
9:21 car top / lift shaft
These lifts are situated in an office tower in a city in Ruhr area in Germany. They were installed in 2005 when the tower was built.
The group consists of 3 lifts, 2 of which are smaller passenger only lifts and a third, bigger one, which is the fireman's lift. It can also be used as freight lift and will serve regular calls if the other 2 lifts are busy. The 3rd lift is the only one to serve the lower floors below ground.
All lifts feature an interesting method to enter calls for people in wheelchairs: Up and down buttons are located at the base of the car panel and when held pressed let the user select a floor without having to reach up to the higher buttons.
The lifts run on Thyssens TCM MC1 controllers. The smaller lifts have asynchronous DAF 290 machines while the bigger lift has a synchronous SC 300 machine. The fireman's lift is in a separate lift shaft and has a separate motor room due to fire regulations.
Many thanks go to my friends from NRW for making this video possible!
Common data:
Manufacturer: ThyssenKrupp, 2005
Type: Traction, 2:1 roping
Fixtures: Step Modul
Speed: 2.5 m/s
Logic: ThyssoControl TCM MC1
Passenger only lifts:
Capacity: 13 persons / 1000 kg
Floors: 19: E, 1-18
Travel height: 59.9m
Drive: ThyssenKrupp MFC 20
Motor: DAF 290 M, 17.2kW
Fireman's / Freight lift:
Capacity: 16 persons / 1250 kg
Floors: 23: U4-U1, E, 1-18
Travel height: 71.4m
Drive: ThyssenKrupp CPI 60
Motor: SC 300 M, 19.5kW
WARNING/DISCLAIMER: DO NOT attempt to copy anything shown in the video without having the proper knowledge of how to do so! LIFT SHAFTS and MACHINE ROOMS are very DANGEROUS places and are NOT MEANT to be accessed by inexperienced or untrained personnel!
Dangers in these environments include but are not limited to crushing, electrocution, falling and burns.
Пікірлер: 33
2:1 roping always fascinated me
Great you found great lifts, they are very fast and have the pre-doors, really top lifts.
@TheLiftDragon
Жыл бұрын
Yes, they indeed are very nice, everything works well here. (except the brake-holing time of the big lift should be adjusted, it is too short) I have to thank my friends from NRW in this place since they were the ones that discovered the lifts, not me.
@ElevatorExploration
Жыл бұрын
@@TheLiftDragon Indeed we notice that the large elevator does not manage to adjust the first time to the floor. Your friends have found great elevators ;)
gutes Video! Einen solchen Antrieb habe ich noch nie gesehen!
@TheLiftDragon
Жыл бұрын
Danke! Solche Direkttraktionsantriebe findet man heute immer öfters - und bei schnelleren Anlagen waren sie schon immer gang und gäbe.
Schöne schnelle Aufzüge. Die Schachtfahrt war geil👍Aber leider noch immer sehr gefährlich
@TheLiftDragon
Жыл бұрын
Dankesehr. Schachtfahrten sind nie ungefährlich, das ist so. Deswegen ist dabei auch immer höchste Vorsicht geboten und man muss 100% bei der Sache sein.
Nice lifts
@TheLiftDragon
Жыл бұрын
Thx!
Cool sogar mit Chimes!
@TheLiftDragon
Жыл бұрын
Jep, die Chimes sind sehr nice.
Very nice thyssenkrupp can be good
@TheLiftDragon
Жыл бұрын
Yes indeed, they can.
Very nice lifts. And what camera are you using
@TheLiftDragon
Жыл бұрын
Thank you! I filmed this using my phone.
@oronalover
Жыл бұрын
@@TheLiftDragon what is the phone exactly?
@TheLiftDragon
Жыл бұрын
@@oronalover Xiaomi Mi Mix 3 but there are newer phones with already better cameras out by now.
Very nice! A bit sloppy on the brake timing parameters, though.
@TheLiftDragon
Жыл бұрын
Thx! Yes, the motor of the bigger lift is deenergized too early so it slips away a bit before the brakes close.
Speziell das die da noch einen Maschinenraum bauten. Bei den Schindler sind die Aufzüge meinstens MRL. Z.b. Das City West Hotel in Chur. Dort gibt es Schindler von 2012 oder so uns die haben 23 Etagen und keine Maschinenräume. Die Maschine gefällt mir jetzt nicht so😅
@sputnik8924
Жыл бұрын
Das ist der Wunsch der Kunden/Architekten. Man spart Platz und somit Geld wenn man einen Maschinenraumlosen Aufzug einbaut. Highrise-Aufzüge haben nach wie vor einen Maschinenraum, bis 3,0m/s ist noch Mid-Rise und somit oftmals MRL.
@Swissvator
Жыл бұрын
@@sputnik8924 Ok stimmt
@TheLiftDragon
Жыл бұрын
Das City West in Chur kenn ich bestens, auf diesen Anlagen war ich auch schon drauf vor über einem Jahr. Selbe Geschwindigkeit, Förderhöhe ist sogar noch einige meter mehr als der Feuerwehrlift hier. Wie bereites erwähnt wurde spielen evrschiedene Faktoren eine Rolle, ob nun ein MAshcinenraum gebaut wird oder nicht. Heute würde man für diese Anlagen auch MRL bauen, hat man ja im City West shcon, aber auch da sind 7 Jahre Unterschied dazwischen! MRLs wurden schon in der Zeit enorm weiterentwickelt und gerade in der Anfangszeit war man noch nicht an dem Punkt, wo man solche Anlagen im Mid-High-Rise Übergangsbereich als MRL bauen konnte. Heute sieht das ganz anders aus, Kone und schindler bieten MRLs bis 4m/s an mittlerweile. Das ist schon ne andere Liga. Die Maschinen hier sind halt normale Direkttraktionsantriebe von Thyssen. Findet man sehr häufig in Deutschland bei diesen Anlagen, die zwischen 1.75 und 2.5 m/s fahren.
@Swissvator
Жыл бұрын
@@TheLiftDragon Ok bist du momentan in Deutschland in denn Ferien?
@TheLiftDragon
Жыл бұрын
Kone und schindler bieten mittlerweile bis 4m/s MRL an. Bei Schindler natürlich mit den FML-Maschinen vom 5500 und bei Kone halt mit EcoDisc. Otis ist soweit ich weiss noch immer bei ihren 2.5m/s Gen2s hängen geblieben, die haben im Portfolio halt einfach ein Loch für diesen Übergangsbereich Mid-High-Rise. Entweder 2.5m/s mit Gurten oder dann direkt die SkyRise Anlagen, die natürlich super sind. Aber dazwischen fehlt irgendwie was. Ich hab für das Video High-Rise jetzt auf die Förderhöhe bezogen, was es korrekt übersetzt eigentlich ja auch heisst. Für Europäische Standards darf man denke ich schon Gebäude ab 50+ Meter als High-Rise bezeichnen, daher das hier. Klar, streng genommen wäre bei TKE jetzt eher so eine DAB450L eine High-Rise Winde. Aber keine Sorge, solche habe ich auch noch auf Lager und sie sind auch schneller als 3m/s. ^^
Why are they braking with only one brake o_O
@TheLiftDragon
10 ай бұрын
The TCM controllers I have seen always apply one brake after the other. That doesn't matter in general as the motor should only de-energise after both brakes have applied. On the larger lift here the timing is not set up correctly, that's why it slips back a bit.
the motor is same as in the BENO recoding kzread.info/dash/bejne/k6yN06OqiLXNYcY.html at 6:48
Ohne Ausgleichseilen bwz. Ketten?
@TheLiftDragon
Жыл бұрын
Genau, hier gibt es kein Ausgleich. Hat mich auch verwundert, aber bei Thyssen ist das wohl eher selten. Schindler macht das aber mittlerweile auch so, ich kenne 70 Meter MRL mit Gurten, kein Ausgleich. Ich meinte aber auch, die Gurte wiegen weniger pro Meter als normale Seile. Und für so einen 1000kg Lift braucht es ja nur 2 Stück mit 60mm Breite.