11. How to Define & Assign Earthquake or Seismic Load in ETABS | BNBC 2020 | Civil Engineering Tips
Ғылым және технология
After watching this watch this video : • 35. Define and assign ...
Like our Facebook Page : / cet.fb
Share your civil engineering videos on our facebook group: / cet.fb
Email: civilengineeringtips1@gmail.com
Mobile: +880-1327213813
WhatsApp: +880-1327213813
Пікірлер: 31
After watching this watch this video : kzread.info/dash/bejne/lWeAm6tql82eo6Q.htmlsi=nmCQj7WmY45f9uqI
@civilengineeringjobsolution
10 ай бұрын
Thanks vai
Nice Presentation .
চমৎকার প্রেজেন্টেশন পেলাম।ধন্যবাদ ভাইয়া
Thank you very much for reference
Vai ami jodi ASCE7-05 use kori problem hobe ki??cause my version doesn't have ubc 94
@CivilEngineeringTips
Ай бұрын
No. It'll be more accurate. BNBC 2020 follows ASCE7-05.
Assalamu alakum viya, ❤❤❤
@CivilEngineeringTips
9 ай бұрын
Walaikum assalam
আপনি অনেক ভালো ভাবে শিখান
@md.saddamhossain4830
9 ай бұрын
সত্যি আপনি অনেক ভালো ভাবে বুঝান
The seismic design principle of BNBC 2020 is not compatible with UBC 94. Rather It is similar to ASCE 7-05. So use ASCE 7-05 as "Auto Lateral Load", not UBC 94.
@CivilEngineeringTips
4 ай бұрын
Yes I agree with you. We should use ASCE 7-05.
Run দেওয়ার পর Display→ Load Assigns →Joint এ গিয়ে EqX (1/3) অথবা EqY(1/3) সিলেক্ট করলে জাস্ট কয়েকটা Frame এর উপরে Load Apply হয়েছে দেখাচ্ছে। এইটার সলিউশন কি?
@CivilEngineeringTips
Ай бұрын
Ignore it.
Etabs 20 te UBC 94 nei sekhetre konta use krbo?
@CivilEngineeringTips
22 күн бұрын
ASCE7-05 (It's correct).
After application of run analysis function, a text showed-up '' No cases set to run''. The analysis function does not run correctly. What should I do now?
@CivilEngineeringTips
6 ай бұрын
After run analysis once you cannot run run analysis again. You've to unlock the file then you can run analysis again. You can not run analysis when it is already run.
Run analysis korbar por theke ...beam,. Colume slub newar oi row ta enable hoa ase ata kivabe thik korbo sir janaben???
@CivilEngineeringTips
8 ай бұрын
Please take screen shot and post them to our facebook group.
Asslamu alaikum vaia, Ex & Ey load ki Assign korte hobe? Naki live load 0.25 deya tei Ex & Ey Assign kora hoyeche?
@CivilEngineeringTips
2 ай бұрын
No need to assign. Just follow the steps that I've shown.
@ShoilpikProkousholy
2 ай бұрын
@@CivilEngineeringTips thank you so much bro. ❤️
analaisis e dile no cases set to run ashe ki korbo
@CivilEngineeringTips
5 ай бұрын
unlock the model. click on the lock icon beside the run analysis icon. then you can run analysis.
@shoumicahmed7009
5 ай бұрын
@@CivilEngineeringTips bhaiya animation dilam but apnar model ta show defrom shape e ex load dile jemon model ta nortase but amar model ta nortase na . amar shudu stair er reference plan /landing ta nortase ar kichu na, ki korte pari.
@CivilEngineeringTips
5 ай бұрын
@@shoumicahmed7009 I think there is error in creating the model. Analyze>Check model
@CivilEngineeringTips
5 ай бұрын
@@shoumicahmed7009 I think there is error in creating the model. Analyze>Check model
torsion niay akta clear video chai
@CivilEngineeringTips
Жыл бұрын
kzread.info/dash/bejne/n6JpyNdyeZu4hJc.html