Rocky Mountain Generator Supply Co

Rocky Mountain Generator Supply Co

Rocky Mountain Generator Supply (RMGS) is the nation’s leading supplier of high-quality Cummins Onan generators. As an Authorized Factory Direct Dealer, RMGS is your single source for RV, Home, Portable, and Food Truck generators. RMGS offers a full range of Electric Generator solutions for Power Systems in a wide range of fuel sources; Natural Gas, Propane, Gasoline and Diesel fueled generators.

Пікірлер

  • @rickandersen8632
    @rickandersen8632Ай бұрын

    You have a great narration voice. I thought I was listening to a NASA commentary.

  • @Dharmagoose
    @Dharmagoose2 ай бұрын

    I have two of these generators one is surging.. any thoughts on that. It starts but then won’t stay running. Checking spark plug today oil filters changed oil change done. Could it be water in the fuel?

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp15432 ай бұрын

    I would suggest attempting to manually operate the choke and see if you can get it to quit surging. If this resolves the surging issue, I would suggest you replace the choke stepper motors and they may have failed. Thanks, and hope you have a wonderful day!

  • @andytavenner8833
    @andytavenner88333 ай бұрын

    Great video thank you.

  • @earlp3315
    @earlp33154 ай бұрын

    Thank you once again. I appreciate your kindness and help. I hope this is the last time, but thank you for sharing your knowledge.

  • @earlp3315
    @earlp33154 ай бұрын

    Thank you for your reply. I appreciate that. I have a new question for you…where can you buy the replacement battery for the Cummins Oman P4500i? I cannot find a brand on the original battery or a part number for it. Can you help with that? Thanks

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp15434 ай бұрын

    According to the Cummins parts manual it is PN A064N120. I have reached out to Cummins for pricing and availability and will get back to you. Unfortunately, they don't give me any additional description besides a Cummins part number. Thanks, and hope you have a wonderful afternoon!

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp15434 ай бұрын

    The cost on the replacement battery is $79.00 plus shipping. If you would like to order please contact us at (303) 777-6778 or via email at [email protected] Thanks, and hope you have a wonderful day!

  • @earlp3315
    @earlp33154 ай бұрын

    I do appreciate this video and your effort to educate us on the general maintenance. Thank you very much. Just a comment about the cabinet design...my hands are still recovering from all of the cuts recieved while trying to remove the oil drain plug. Probably the worst access design of any gasoline engine. Again, thank you for your work !

  • @i_am_thatguy1504
    @i_am_thatguy150412 күн бұрын

    There's a trick. A ratcheting open end wrench, does the job for me

  • @earlp3315
    @earlp33154 ай бұрын

    Is there a fuel filter on the unit? If so, where is it and how do you get to it?

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp15434 ай бұрын

    There is not a fuel filter on the unit that we are aware of and sorry about your hands. I will definitely pass along the feedback to Cummins. Thanks, and hope you have a wonderful day!

  • @barttraynor1220
    @barttraynor12205 ай бұрын

    Thank you for taking the time making this video greatly appreciated.❤

  • @tamchristopher9072
    @tamchristopher90726 ай бұрын

    Hi can you should the way to put the spring on the choke please

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp15435 ай бұрын

    Can you please send me an email at [email protected] and I will send you a picture. Unfortunately, I'm unable to paste a picture in this response. Thanks, and hope you have a wonderful day!

  • @stephengerish6978
    @stephengerish69785 ай бұрын

    Dude.... I appreciate this more than anything right now. Thank you!

  • @fixit4182
    @fixit41826 ай бұрын

    Darn good video👌

  • @joshuasmith2258
    @joshuasmith22586 ай бұрын

    How are you moving the pistons manually?

  • @i_am_thatguy1504
    @i_am_thatguy150412 күн бұрын

    Pull start slowly w battery disconnected

  • @bellaskyproperties9495
    @bellaskyproperties94957 ай бұрын

    My generator, 4500i starts and runs but as soon as I plug my RV in (nothing big running, just battery charger) it immediately shuts off. Any thoughts?

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp15437 ай бұрын

    Unfortunately, I do not believe that is going to be an easy one to diagnose. If your generator is still under warranty, please let me know your zip code and I can refer you to the nearest Cummins distributor location for service. You can email me at [email protected] Thanks!

  • @bellaskyproperties9495
    @bellaskyproperties94957 ай бұрын

    10996 West Point NY @@rockymountaingeneratorsupp1543

  • @HeatherStone-pg3ro
    @HeatherStone-pg3ro8 ай бұрын

    Why is my carburetor leaking gas after the 3rd use?

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp15438 ай бұрын

    My apologies for the delayed response. Did you install the high altitude carburetor kit? If so, sometimes the O-ring gasket can get pinched and that could cause the carburetor to leak. Thanks, and hope you have a wonderful day!

  • @toddschmidt32
    @toddschmidt329 ай бұрын

    Thanks for making the video. Straight to the point, no ten minute intro filled with garbage. Good views with clear explanation!

  • @thomasschuh5535
    @thomasschuh553510 ай бұрын

    Great video, thanks for pulling this together. My only suggestion is to not bother disconnecting the two electrical connectors on the carb. If you do everything up to that point, you can easily get to the jet to remove and replace it.

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp154310 ай бұрын

    Glad you found the video beneficial and thanks for the additional advice!

  • @ericapallaron3379
    @ericapallaron337911 ай бұрын

    Very helpful but I must have not positioned the choke lever right because now the choke in the on position is actually off and moving it all the way to the left is actually on so I have to figure that out

  • @tamchristopher9072
    @tamchristopher90726 ай бұрын

    That's the hard part I can't figure it out too 😂

  • @jasonbruney8842
    @jasonbruney884211 ай бұрын

    Can you use the 10w-30 oil for your air filter?

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp154311 ай бұрын

    Thanks for the question. I don't see anything in the owners manual referencing or suggesting using oil on the air filter. Thanks, and hope you have a wonderful day!

  • @vmaxes
    @vmaxes11 ай бұрын

    Just bought one and it just surges, will not idle.revving up and down unless i put a full load with my air conditioner turned on in the trailer, im just above 2000ft elevation in Alberta. Is it a jetting problem?

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp154311 ай бұрын

    Likely not a jetting issue. If you just purchased it, I would recommend that you get it to a Cummins distributor location and have it looked at under warranty. Thanks, and hope you have a wonderful weekend!

  • @vmaxes
    @vmaxes11 ай бұрын

    @@rockymountaingeneratorsupp1543 will be this week, ill let you know what it was

  • @jtkrpm1
    @jtkrpm1 Жыл бұрын

    Can this charge a EV? something about the ground. Some generators need some kind of jumper to fool the vehicle.

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp1543 Жыл бұрын

    Unfortunately, I don't know the answer to your question. I would check with the EV charging requirements with respect to amperage and what voltage the EV charger requires. Thanks!

  • @Rocksteady176
    @Rocksteady176 Жыл бұрын

    Well, after 7 months of good use, mine finally took a crap. Even after recommended schedule service. Waiting to see what Cummins does about it. Just like all portable gens, except Honda, they dont last more than a year. If Cummins gives me a new one, per warranty, I am selling it and going back to Honda.

  • @jhm68
    @jhm68 Жыл бұрын

    Do you check the oil level with the dip stick screwed all the way in or just loose?

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp1543 Жыл бұрын

    To check the oil, do not screw in the dipstick. Leave it loose and you will be good to go! Thanks, and hope you have a wonderful afternoon!

  • @jhm68
    @jhm68 Жыл бұрын

    Thank you for the help.

  • @chandee80
    @chandee80 Жыл бұрын

    I’m having issues with my Cummins Onan p4500i generator cranks but won’t start, any suggestions?

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp1543 Жыл бұрын

    See if you can manually operate the choke and see if it starts. The stepper motor on the choke mechanism may have failed. Thanks!

  • @chandee80
    @chandee80 Жыл бұрын

    @@rockymountaingeneratorsupp1543 the choke is operating like it should and still no luck and try manually no luck

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp1543 Жыл бұрын

    @@chandee80 Sorry to hear that this approach did not fix the issue. I would recommend taking it to your local Cummins distributor. I can help you locate if you like with your zip code or here is a link locator.cummins.com/GlobalLocator/homeScreen.action?request_locale=en_US

  • @williamolliges2622
    @williamolliges26223 ай бұрын

    Damnit. Mine’s having hot start issues, and is going into overload mode at 50% load. It sounds like the choke problem you describe might be the culprit.

  • @mikerowley3508
    @mikerowley3508 Жыл бұрын

    I was hoping you would let us know how much oil to put in. I purchase My RV used and it came with this generator but no manual. Any idea on how much oil?

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp1543 Жыл бұрын

    Mike, 0.6Qt. (20.3oz). Please email me, [email protected] and I can email you the manual. Thanks, and hope you have a wonderful day!

  • @straynoodle5057
    @straynoodle5057 Жыл бұрын

    Thanks

  • @mmesmer6447
    @mmesmer6447 Жыл бұрын

    I replied to pachilly below with a far easier method for changing the engine oil without needing to disturb the drain plug. When refilling it is important to have the P4500 perfectly level to prevent over or under filling. Fill just to the bottom thread. A 5 ml Luer-Lock tip syringe is extremely useful for adjusting the oil level. By not spilling any oil it is easy to ascertain if the engine has a main shaft seal leak. While not common I have seen a leak on a new generator.

  • @i_am_thatguy1504
    @i_am_thatguy150412 күн бұрын

    I believe I have that problem. Whats the fix?

  • @edwincruz8365
    @edwincruz8365 Жыл бұрын

    Is their a wire that doesn’t connect to anything?

  • @michaele979
    @michaele979 Жыл бұрын

    Which valve is the intake valve and which one is the exhaust? They have different clearances, so you need to know. The user manual doesn't say either. The parts diagram doesn't answer the question either. I even called 1-800-cummins tech service and HE could not tell me!

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp1543 Жыл бұрын

    Michael, I will inquire with Cummins and get back to you. Thanks, and hope you have a wonderful weekend!

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp1543 Жыл бұрын

    Here is the response that I received back from Cummins. The intake valve is always the valve closest to the air filter side of the engine. The exhaust valve is the valve closest to the muffler side of the engine. Thanks!

  • @michaele979
    @michaele979 Жыл бұрын

    @@rockymountaingeneratorsupp1543 I went into deep research mode and eventually found in the master parts manual that the left hand valve is exhaust in the right hand is intake. Thanks! Great video!

  • @michaele979
    @michaele979 Жыл бұрын

    Another helpful clarification: the manual quotes valve lash for intake as "0.0035 +/- 0.0043", which the latter number would then be a ridiculous tolerance. The numbers are OK, but the "+/-" should just be a "-" (dash) thus indicating a range, NOT a tolerance. Same is true for the Exhaust side numbers.

  • @707LDH
    @707LDH Жыл бұрын

    What does the phillips head adjustment on top of the carb do? Idle set? A/F mixture?

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp1543 Жыл бұрын

    Unfortunately, I do not currently have an answer for you. I have submitted to the factory and will respond back. Thanks!

  • @707LDH
    @707LDH Жыл бұрын

    @@rockymountaingeneratorsupp1543 Roger that. I believe it to be an A/F mixture, but would love the real scoop or how it supposed to be set. My 4500 has a very erratic idle and some occasional misfires at full song as well.

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp1543 Жыл бұрын

    @@707LDH I just received confirmation back from Cummins; the black, plastic, Phillips head screw on the top of the carburetor is the idle adjustment screw. Please let me know if you need anything additional and thanks for contacting Rocky Mountain Generator Supply!

  • @707LDH
    @707LDH Жыл бұрын

    @@rockymountaingeneratorsupp1543 That is pretty vague. Does it adjust Fuel or Air?

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp1543 Жыл бұрын

    @@707LDH I copied your reply and sent to Cummins for further details. The following is what I received back from them. I'm hopeful that this makes the answer a little less vague. The pilot jet is tied to the idle. It controls the fuel going into the carburetor during startup. The idle adjustment screw adjusts the fuel flow that is allowed through the pilot jet on startup.

  • @frankjdm4636
    @frankjdm4636 Жыл бұрын

    Thank you!

  • @gpslightlock1422
    @gpslightlock1422 Жыл бұрын

    Glad I watched the video. Thanks.

  • @Jbajapaca
    @Jbajapaca Жыл бұрын

    Thanks

  • @lawrence7065
    @lawrence7065 Жыл бұрын

    Thanks for letting us know the gap adjustment . Took me hours to find setting.

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp1543 Жыл бұрын

    Our pleasure and please let us know if there is anything additional we can assist you with. Hope you have a wonderful afternoon!

  • @elchingondechicali
    @elchingondechicali2 жыл бұрын

    Thanks for this video. It was very informative

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp15432 жыл бұрын

    Moses, our please and thanks for the reply! Hope you have a wonderful day and please let us know if there is anything further we can assist you with in the future!

  • @cic-jakevanddalgeemyers.2739
    @cic-jakevanddalgeemyers.27392 жыл бұрын

    WOW 😮

  • @jeffhall1393
    @jeffhall13932 жыл бұрын

    How much will the unit take?

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp15432 жыл бұрын

    Are you referring to the quantity of oil? Thanks!

  • @jeffhall1393
    @jeffhall13932 жыл бұрын

    Yes, I see 20.3 ounces

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp15432 жыл бұрын

    @@jeffhall1393 That is correct. The oil capacity is: 20.3 ounces. Thanks, and hope you have a wonderful day!

  • @timwagoner6610
    @timwagoner66102 жыл бұрын

    I'll be using my unit between 5,400 and 8,000 feet. Which jet would you recommend?

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp15432 жыл бұрын

    I would recommend Jet C. 5,000-6,000 Feet. This way you are pretty much in the average elevation with your Jet choice. Thanks!

  • @jtt5858
    @jtt58582 жыл бұрын

    Does it matter if I don’t use the Cummins brand oil?

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp15432 жыл бұрын

    No, you do not have to utilize Cummins branded oil. Please follow the recommended viscosity in the owners manual. Thanks!

  • @kylearaiza8808
    @kylearaiza88082 жыл бұрын

    Decent enough generator. I have one it did save my meat in the freezers and served it’s purpose. But it is just another cheaply made import the exact same as Westinghouse and other brands. There is a few issues with the cheap Chinese carburetor and it’s components the Honda carburetor would work better for this. The switch from gas to LP always gets stuck and the machine dies when it should stay running flawlessly. Unfortunately Cummins only had one option to return it to a service center instead of sending out replacement parts and I refuse to have a moron touch these as it had a stripped screw from the factory.

  • @jayc9017
    @jayc90172 жыл бұрын

    My generator is similar it does not want to stars it is doing a clicking sound after a every starting attempt !!! Any one know what might be the issue???

  • @willycolby1216
    @willycolby12162 жыл бұрын

    Unfortunately, I don't have a specific answer for you. Please let me know what zip code you are located in and we can provide contact information for the nearest Cummins distributor. Thanks, Willy Colby, Mobile: (303) 618-9257

  • @elchingondechicali
    @elchingondechicali2 жыл бұрын

    Low battery on mine. I had to use the pull start option and let the generator run for over an hour to recharge. After that it's been fine. Also, if you shut it off and then immediately try to start the push button feature, it won't do it. You'll have to wait a minute or two

  • @jeribonham80
    @jeribonham802 жыл бұрын

    Mine shut off and i cant get to start again, has gas and oil new battery and spark plug..what should i check next?

  • @willycolby1216
    @willycolby12162 жыл бұрын

    Did it run after you installed the high altitude carburetor kit? Please make sure that you have the main power switch turned on and the fuel is turned on. Please feel free to give me a call if you wish to discuss further. Office: (303) 777-6778 or my mobile (303) 618-9257. Thanks, and hope you have a wonderful weekend!

  • @noodlejohnson
    @noodlejohnson2 жыл бұрын

    I got a brand new onan and upon initial start with nothing plugged in the overload light comes on and will not reset. Engine starts and runs fine.

  • @willycolby1216
    @willycolby12162 жыл бұрын

    My apologies for the delayed response. Please give us a call at: (303) 777-6778 and we would be happy to provide you information on your closest Cummins Distributor location and can repair your generator under warranty. Thanks, and hope you have a wonderful evening!

  • @jeremiahephrim5339
    @jeremiahephrim53393 жыл бұрын

    Can toy make a trouble shoot video because I’m having trouble starting mine it will start after 15-2 mins of trying until the battery goes out and then pull starting over and over again but then the next day the same thing happens

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp15433 жыл бұрын

    You should not be having that type of an issue. What model do you have and when did you purchase it? I may be still under warranty and we can provide you information on whom can complete a warranty repair is still covered under factory warranty. Thanks, and hope you have a wonderful day!

  • @bobbeanbags
    @bobbeanbags3 жыл бұрын

    This is an awesome video!!! Do you have one one storage/draining fuel from and cleaning carburetor?

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp15433 жыл бұрын

    Unfortunately, we do not at this time. We will add that to our list of suggestions. Thanks for your comments and please let us know if there is anything further we can assist you with.

  • @ThePaulvito1
    @ThePaulvito13 жыл бұрын

    What jet came from factory?

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp15433 жыл бұрын

    The jet that comes from the factory with the generator is good to 2,000 above sea level. Beyond that; the manufacture recommends the high altitude carburetor kit. We offer them for $29.00 with free shipping and sales taxes would apply. Thanks, and hope you have a wonderful holiday weekend@

  • @joeybishop7604
    @joeybishop76043 жыл бұрын

    NEVER use engine oil on an air filter 🤦‍♂️ Use air filter oil. And yes, there is a difference

  • @CFmechanic2020
    @CFmechanic20208 ай бұрын

    The manual says to use clean engine oil....

  • @zenjamin6262
    @zenjamin62623 жыл бұрын

    I USE MY WIFES PANS TO CHANGE THE OIL TO !! shh shhhhh "our little secret"

  • @car_junkie
    @car_junkie3 жыл бұрын

    Do Not follow this video! The connector mentioned at 2:37 is impossible to get to if you don't have the hand size of a child. You can just pull the carb bowl off with a 10 mm wrench and then unscrew the jet with a flat head. "The second connector is a little tricky" is the understatement of a lifetime....

  • @Fraggboy
    @Fraggboy3 жыл бұрын

    👆 This! Pull the air cleaner box out and you can remove the carb bowl. Super simple. I just received my 4500, and swapped the jet out.

  • @dcshoe559
    @dcshoe5593 жыл бұрын

    What size is the main jet? Is it possible to just replace the jet instead of buying the complete jet?

  • @mikeetienne1685
    @mikeetienne16853 жыл бұрын

    Hi. I'm trying this right now. I have the bowl off but how do you access the jet with a flat head? There isn't enough space to get a screwdriver in there. Thx Mike

  • @mikeetienne1685
    @mikeetienne16853 жыл бұрын

    @@Fraggboy hi. How did you access the jet with a screwdriver without removing the carb? I've removed the bowl but cant get a screwdriver in to access the jet Thx Mike

  • @Fraggboy
    @Fraggboy3 жыл бұрын

    @@mikeetienne1685 You have to remove the air cleaner box for more clearance. A few screws holds it in.

  • @CT9905.
    @CT9905.3 жыл бұрын

    Outstanding and informative video, I own the Westinghouse version of this generator.

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp15433 жыл бұрын

    Anthony, glad you found it informative and please let us know if there is anything further we can assist you with!

  • @mikegoettina
    @mikegoettina3 жыл бұрын

    dam i went 6000hrs on my spark plug and i change oil ever 2 week at like 100 hrs some times 200hrs if it snowing a lot

  • @jaydunbar7538
    @jaydunbar7538 Жыл бұрын

    I’m wondering how that’s going for you after a few years, just got mine and it seems like a solid unit. My only complaint is the case, the accesses were clearly not designed by someone that has ever serviced anything in their life.

  • @jacobsandall9482
    @jacobsandall94823 жыл бұрын

    we just purchased one and it came without a dipstick do you have a replacement part you would recommend?

  • @rockymountaingeneratorsupp1543
    @rockymountaingeneratorsupp15433 жыл бұрын

    Jacob, thanks for the comment. Please give me a call (Willy Colby) @ (303) 777-6778 with your serial number and shipping address. I will get you a replacement dipstick. Thanks, and hope you have a wonderful week!

  • @jacobsandall9482
    @jacobsandall94823 жыл бұрын

    @@rockymountaingeneratorsupp1543 Thank you so much but we contacted Cummins customer support and they have one on order for us. Thank you so much for your kindness Have a good week!