ELECTRICAL TECHNOLOGY and INDUSTRIAL PRACTICE
ELECTRICAL TECHNOLOGY and INDUSTRIAL PRACTICE
This technical channel is all about Electrical Technology and Industrial practice. In this channel we shall share different industrial practices, engineering fundamentals. A learning gateway to relate between Electrical engineering & its industrial application. We shall explain different aspects of electrical engineering in the most easy way. So please watch and enjoy electrical engineering.
Disclaimer:
Purpose of all the videos shared through this channel is only for sharing of ideas & knowledge, understanding of engineering and nothing else.
Viewers are advised not to perform any practical activity based on the videos published herein, without referring latest applicable norms/standards, and/or having guidance of experienced professionals.
If such activity is performed the channel shall not be responsible for any after happening.
Пікірлер
If I only know primary voltage and secondary voltage and secondary amperes how do I find primary amperage
Why the angle between the vref and the flux v is not 90 degrees, i have seen many text that stated that, by the way thank you very much for the content i am studying this at my university and i am a little bit struggling haha
Nice explanation
0.859 sq.inch=554sq.mm, provided Busbar 1000sq.mm>554sq.mm; Hence 1000sq.mm is more than the required minimum size busbar.
Hi I believe in both the fault conditions NCT sec. Current direction direction will be same. Your considering two different directions for outside and inside faults. Could you please correct me if I am wrong
Great effort friend
Great one small explanation but all thing include
Aptly explained. Hope this the tutorial will aid students as well as beginners of profession a handy presentation. Thanks a lot.
Long time
It was really informative video. Please can you provide a clear view regarding Io and I1' both are same and if they are not, then Is Io will be considered as no load current or I1'?
amazing video.
Hi. Are you sure about your explanation for close the disconnector???? 9:00 to 10:00 You can not close the disconnector just because the voltage of both side is equal.
Possible. Isolator can be closed if there is no change in current or voltage.
but you did not say that in video. Please check again your description about the priority of disconnector and circuit breaker. You said before opening the outgoing CB , you could close the disconnectir. Even you said , first close the coupler CB and after that close the bypass disconnector . It is completely wrong and impossible
Thank you sir,so much helpful🙏🙏,Plz Upload new video☑️
Thank you sir,very informative video🙏🙏,Plz Upload new video☑️
Thank you sir,so much helpful🙏🙏,Plz Upload new video☑️
How to calculate generator or transformer earth fault current which one we are limiting through NGR.
can someone pls share link to part 2 of this video
When outside fault are occurring near light why mcb are phase 50ka fault current..
Need video on ferroresonence resistor
Can you please add some ups sizing contents for NiCd/Lead acid .
Good and informative lessons
Thanks Sir
Nice explanation
Like your information videos ,pls suggest suitable numerical book on protection for experienced industrial professionals
Nice & helpful video
Best
How calculate VA of PT. Pls make a vedio
Sir, as I know, transformers do not contribute or feed fault current in the system, might be i am wrong.
confusing concept 😮😮😮
what's logic of 58 percent and 33 percent settings. clarify
Love it
Nice lecture👍👍
Can you please further explain what is this 7% of reactor and why do we consider this.
Bro which software are you using for explaining this ?
Hindi me Explain karne me Tx Dena padta kya aap ko....
it is superb video .could you explain me the difference between fixed KVAR and virable KVAR please?
Quite illustrative. Excellent,
❤🇧🇩
I need your session. How do i contact you?
Thanks for your interest but unfortunately I do not do such sessions. You may put your query here. I will try to answer.
Need differential relay settings
explain very nice
Excellent
Your black arrow is the wrong way around
Yes correct
How do i contact you
How to calculate the settings for the feeder relay used on RMU.
😢ssazstslssaz😮s
Sir kindly provide more information why protection class of PT has 3P,6P,5P when we choose 3p n all. Some time I have seen secondary of PT in broken delta is 110/3 not 110/√3
Meaning of 3P, 6P,5P
HOW SHOULD WE CALCULATE THE SHOT CIRCUIT THERMAL EFFECT FOR WIRES& CABLES
Sir,Pl make video on different IEC Characteristic and relay coordination using them