Probir Kumar Saha

Probir Kumar Saha

Knowledge sharing...

Share(3)

Share(3)

A Sweet Home

A Sweet Home

Beautiful Atish Bazi show

Beautiful Atish Bazi show

Plaster pull out test

Plaster pull out test

The beauty of Omani dates

The beauty of Omani dates

CONCRETE PILE CLEAR COVER

CONCRETE PILE CLEAR COVER

Concrete Slump test

Concrete Slump test

MOR test

MOR test

Пікірлер

  • @nicholasbrunetti2956
    @nicholasbrunetti29562 ай бұрын

    12 foot wide is at the maximum for FF 100/fl65 floors......

  • @AFIFVY
    @AFIFVY2 ай бұрын

    Last 3months i was searching this fish finally

  • @bicbouy4126
    @bicbouy41264 ай бұрын

    Guy checking laser screed is set at right height at the start isn’t even holding the laser height stick plumb, he tells the operator 2 millimetres up when his height stick is out of plumb by about 2 millimeters. Guy needs a spirit level bubble on his height stick

  • @Forgotthatshit
    @Forgotthatshit5 ай бұрын

    Hi. What is plaster pull out equipment specification and how i can buy it?

  • @pilingdrill
    @pilingdrill Жыл бұрын

    Good job

  • @mythistory6019
    @mythistory6019 Жыл бұрын

    Any contacts of the agency to conduct this test in Bangalore ?

  • @daelster
    @daelster Жыл бұрын

    Good music

  • @jodelmaralvessaraiva5780
    @jodelmaralvessaraiva5780 Жыл бұрын

    Vou parai

  • @joshuaandrew691
    @joshuaandrew691 Жыл бұрын

    Dear Mr. probib kumat, good informative video. Also, Please tell what is the name of pull out test equipment, current reading and required reading with unit. Thanks.

  • @alexandermadwrite2154
    @alexandermadwrite2154 Жыл бұрын

    But how do you do it on Mobile

  • @calebcoffman6897
    @calebcoffman6897 Жыл бұрын

    Yikes 9” slump is absolutely terrible even with fly ash and being a flowable mix with fibers, even a high range mix design typically won’t call for that high of a slump, that’s terrible. Good luck on those breaks

  • @calebcoffman6897
    @calebcoffman6897 Жыл бұрын

    Then again the testing procedure for slump was done wrong, he was tamping the first layer and hitting the bottom of the slump cone, plus he only did a maybe 3 second pull which doesn’t constitute a proper slump test, he did do the test within 2 min 30 secs, so at least he did one thing right.

  • @chautrongan6183
    @chautrongan61832 жыл бұрын

    Thank Sir 👍😊

  • @mr.alankar3059
    @mr.alankar30592 жыл бұрын

    half of test explained sir... how to cut plaster in circle shape, its deep how to fix dolly in that grove, which adhesive required how many times to set adhesive after that you explain next procedure

  • @probirkumarsaha
    @probirkumarsaha2 жыл бұрын

    Thanks for your comments. Plaster cut in circle shape buy pull up test. Dolly fixed by glue at least 24 hours. At this moment I have forgotten the adhesive name.

  • @constructionknowledge6012
    @constructionknowledge60122 жыл бұрын

    Nice video

  • @kiplane5229
    @kiplane52292 жыл бұрын

    Can I add a video I’ve posted to my friends channel which is opposite of what your doing..your taking her video to yours but I want to give my video to his softball channel

  • @robertchu1179
    @robertchu11792 жыл бұрын

    Can someone plz tell me what does RCC means, it’s full name

  • @probirkumarsaha
    @probirkumarsaha2 жыл бұрын

    RCC means "Reinforcement Cement Concrete"

  • @robertchu1179
    @robertchu11792 жыл бұрын

    @@probirkumarsaha thank you so much

  • @kenbrown9228
    @kenbrown92282 жыл бұрын

    X

  • @tusharshinde2121
    @tusharshinde21212 жыл бұрын

    How much minimum values required for pullout test withunit of measurements

  • @naveedjan8715
    @naveedjan8715 Жыл бұрын

    if it is pre-mixed plaster, refer to manufacturer material data sheet. it varies but average 0.3 MPa minimum. For in situ plaster refer to British Standards.

  • @hitendrarayamajhi7262
    @hitendrarayamajhi72622 жыл бұрын

    If in case joints needed to be placed due to break in concreting works, What should be its position? What should be needed to be done in such case?

  • @probirkumarsaha
    @probirkumarsaha2 жыл бұрын

    Thank you for your comment. Could you please elaborate your question for my better understanding?

  • @hitendrarayamajhi7262
    @hitendrarayamajhi72622 жыл бұрын

    @@probirkumarsaha Sir. I mean to say that if in any case when we cant do the whole quantity of concrete continuously which is required for the pile cap and if we are under the circumstances where we have to beak the concreting work and introduce a joint in any way, then in such case what should be the position of the joint and what type of joint (vertical or horizontal) is needed to be introduced in the pile cap ?

  • @probirkumarsaha
    @probirkumarsaha2 жыл бұрын

    @@hitendrarayamajhi7262 Thank you. The joint is called Construction joint. Before the 2nd pour concreting some bonding agent can used before pouring. The joint could be made rough by chipping before the the 2nd pour.

  • @govigobi
    @govigobi2 жыл бұрын

    Where it's mentioned for vertical distance mention in IS2911

  • @rakeshmondal7990
    @rakeshmondal79902 жыл бұрын

    Spacing this cover block as per is per meter

  • @probirkumarsaha
    @probirkumarsaha2 жыл бұрын

    Yes

  • @Lisa-yy4or
    @Lisa-yy4or2 жыл бұрын

    I don't have any friends in youtube this helping to me

  • @ashishchaudhari7048
    @ashishchaudhari70482 жыл бұрын

    Sir, if you explain about readings and reference range of pull out test is much appreciated.

  • @dabrosfloorsurveysltduk1789
    @dabrosfloorsurveysltduk17892 жыл бұрын

    This procedure shown at 17:00 can lead to delamination issues.

  • @Prashant-sr6fj
    @Prashant-sr6fj2 жыл бұрын

    Hi i am PhD research scholar at IIT Bombay. can you please send me the equipment specification, I want purchase this. @probir saha

  • @probirkumarsaha
    @probirkumarsaha2 жыл бұрын

    Hi, Extremely sorry. At present I am not in position to help you. Anyway I will try to help you.

  • @Prashant-sr6fj
    @Prashant-sr6fj2 жыл бұрын

    @@probirkumarsaha thanks for your reply. i am waiing for the machine specification. or please give me the suppliers information.

  • @joylincy6580
    @joylincy65802 жыл бұрын

    Thanks for the video.

  • @SATISHYADAV-tx8ho
    @SATISHYADAV-tx8ho2 жыл бұрын

    Re bend ka kaha per hai

  • @SATISHYADAV-tx8ho
    @SATISHYADAV-tx8ho2 жыл бұрын

    Re- Bend IS 1786-2008 ME JO DIYA HAI WAHI WALA ULTA KARKE PRESS NAHI KARNA HAI MAIDRIL SE HI 157.5 ME LANA HAI.SIR KAISE HOGA

  • @kevin_prathi
    @kevin_prathi2 жыл бұрын

    Is there any test to check the plastering work in wall (inner wall plastering and outer wall plastering)

  • @probirkumarsaha
    @probirkumarsaha2 жыл бұрын

    Yea, the same test for inner and outer wall

  • @kevin_prathi
    @kevin_prathi2 жыл бұрын

    @@probirkumarsaha thank you

  • @moathunter5504
    @moathunter55042 жыл бұрын

    Why is he using a Helmet for this work ?

  • @probirkumarsaha
    @probirkumarsaha2 жыл бұрын

    Hi, It was a Project's HSE requirement.

  • @nkg00007
    @nkg000072 жыл бұрын

    Clicking on cuztomize channel will take me to youtube studio...Please update this video

  • @probirkumarsaha
    @probirkumarsaha2 жыл бұрын

    Thanks for your comment. Noted.

  • @Oaik_knowledge
    @Oaik_knowledge3 жыл бұрын

    Hi bhya kaise ho. Can I talk to u Plz come on my WhatsApp 9759746678

  • @raffiehydermirza1803
    @raffiehydermirza18033 жыл бұрын

    Equipment name and how many samples to be taken and is it also same for gypsum?

  • @rkbisheswar2024
    @rkbisheswar20243 жыл бұрын

    Kindly let me know the your testing strength

  • @qillaainur2877
    @qillaainur28773 жыл бұрын

    flat floor good ....

  • @gladiator2017
    @gladiator20173 жыл бұрын

    @probir Saha - do you know any govt authorized quality testing firm which conducts this in kerala ? I am facing some plastering issue in my apartment and builder is saying plastering is fine. I want to understand how to verify that. Also is there any govt lab in kerala which takes plastering sample and do some testing to measure the cement/sand ratio.

  • @probirkumarsaha
    @probirkumarsaha3 жыл бұрын

    Hi, Sorry I don't know.... Thanks for your question.

  • @gladiator2017
    @gladiator20173 жыл бұрын

    @@probirkumarsaha do you know the standard value for the pressure required in India for apartments when the plastering test succeeds ?

  • @probirkumarsaha
    @probirkumarsaha3 жыл бұрын

    Hi, I think this docs may help you. www.mpwrd.gov.in/documents/18/b6596087-233a-49ad-9c2e-b4fb39237994

  • @probirkumarsaha
    @probirkumarsaha3 жыл бұрын

    mddaonline.in/downloads/MDDALINKS/pdf/nbc.pdf

  • @janbellopez164
    @janbellopez1643 жыл бұрын

    Good work,i am concrete riding trowel from phillipines super flat crew

  • @nabeenkumardora1959
    @nabeenkumardora19593 жыл бұрын

    What is the spacing of cover blocks vertically?

  • @probirkumarsaha
    @probirkumarsaha3 жыл бұрын

    Please have a look this video, 5min 29 sec, vertical spacing 1m we have considered. kzread.info/dash/bejne/ZJ6WmMyEgceZgqg.html

  • @vivekgupta7104
    @vivekgupta71043 жыл бұрын

    What is the is code can any one recommend

  • @AHoney-xl9ux
    @AHoney-xl9ux3 жыл бұрын

    How much plaster strength required in N/mm2 ? What is acceptance criteria?

  • @probirkumarsaha
    @probirkumarsaha3 жыл бұрын

    The test will work reliably over an adhesion strength range between 0.2 and 50 N/mm2.

  • @habibkhan8410
    @habibkhan84103 жыл бұрын

    Dear Sir can you provide the Contact details of testing agency in DEHLI NCR india.

  • @probirkumarsaha
    @probirkumarsaha3 жыл бұрын

    Testing agency I know in Oman only.

  • @hnguyen136
    @hnguyen1363 жыл бұрын

    me like and sub ignore the hater from dislike :D

  • @lethukuthuladerrick5522
    @lethukuthuladerrick55223 жыл бұрын

    Perfect teaching. I now understand keep it up thank you

  • @akhtarali-qv3en
    @akhtarali-qv3en3 жыл бұрын

    Thanks for latest update

  • @drogogaming8302
    @drogogaming83023 жыл бұрын

    why shear links are not provided in pile cap

  • @TonzandPinkz
    @TonzandPinkz3 жыл бұрын

    This is RAK Ceramics and the one who tested the tiles is my friend😁😁😁

  • @m-2728
    @m-2728 Жыл бұрын

    Rak ceramics this is best company in the UAE

  • @arjunapoxegroutwork8877
    @arjunapoxegroutwork88773 жыл бұрын

    Apoxe & Grouting work 9601191392

  • @dancristurean3680
    @dancristurean36803 жыл бұрын

    Hello, Good work! I also want to buy a device for measuring flatness, the one that appears at minute 16; 28 and 34. Can you tell me his name or the name of the company where I can buy it from? If you can also for curing equipment? thank you , Dan

  • @emmalee2520
    @emmalee25203 жыл бұрын

    we supply various compression testing mahcine and universal test machine. Whatsapp 0086 13363667903

  • @jaidulsekh3883
    @jaidulsekh38833 жыл бұрын

    Agar pile kajer khobor nai dada

  • @enkrypt3d
    @enkrypt3d3 жыл бұрын

    7:37 would you mind not walking through the freshly floated concrete? KTHX

  • @probirkumarsaha
    @probirkumarsaha3 жыл бұрын

    Hi, Thanks for your comment. Actully we have applied surface hardner on the floor, for that and floor undulation measuring purpose; we walked through the wet floor.

  • @enkrypt3d
    @enkrypt3d3 жыл бұрын

    @@probirkumarsaha lol just busting chops... I'd be annoyed though if I was that machine operator and he kept walking thru the freshly floated concrete haha