Пікірлер

  • @kevinb21
    @kevinb21Ай бұрын

    So my ac works fine. But heat doesn't turn on (at least, not the fan. Can't tell about the actual heating). The white wire has no power (at the thermostat). could that be a sequencer issue?

  • @dogbone1065
    @dogbone10652 ай бұрын

    I would say this is the best video yet, the other videos i have watched are confusing because they keep switching around with to much unnecessary bullshit. You get to the point. I only needed to see where to connect each wire.

  • @mr.18s73
    @mr.18s733 ай бұрын

    If the heat sequencer is timedelay Does it take a while for heat to actually kick in?

  • @benm1751
    @benm17513 ай бұрын

    I currently have an electric furnace and, with the thermostat off, the sequencer is turning the heat elements on. Thermostat off. Unit keeps heating. Fan off. Just random turning on and off of heat elements, this issue started after I put everything back together after a deep clean. So the sequencers are working, but im not asking for heat. Any ideas?

  • @ntexashvac7240
    @ntexashvac72403 ай бұрын

    So what’s happened most likely is the ceramic rod that holds up the contact inside the sequencer has broken. When that happens the sequencer actually fails in the on position so it’s actually not working properly because it’s heating without a call for heat. The intermittent on off comes from the high limit switch interrupting the electric flow and heating as the temp inside the heat kit rises due to no airflow because the fan is off. You’ll need a new sequencer.

  • @benm1751
    @benm17513 ай бұрын

    @@ntexashvac7240 thanks for the quick reply. I watched a video, may of been yours, of a sequencer taken apart and explained how it works, along with your reply im confident that is the issue. My unit is 30 years old, and has 2 separate sequencers, im going to replace both. Thank you for your help!

  • @benm1751
    @benm17513 ай бұрын

    @@ntexashvac7240 do you think its safe to leave the unit on, until parts arrive, and have it still cycling on the heating elements ?

  • @ntexashvac7240
    @ntexashvac72403 ай бұрын

    @@benm1751 I would not leave it powered up if it’s going on and off, if the limit switch fails you could have a an over heat issue that could damage the heat kit or worse.

  • @benm1751
    @benm17513 ай бұрын

    @@ntexashvac7240 mt fear exactly, I will leave it off thank you

  • @The1realro
    @The1realro4 ай бұрын

    I finally get it because of you what an awesome laid back but perfectly explained

  • @stephenbraden6239
    @stephenbraden62395 ай бұрын

    Thanks for your video. Im going to check out my sisters mobile home furnace. Its blowing cold air.

  • @williambrown35
    @williambrown355 ай бұрын

    Hi l'm new to your channel and I had a technician out and he used these words. Heat handler has 3 heat bank's and it is a Trane and he said that a limit popped and is not letting the 3rd heat bank is not coming on what is he meaning about that?

  • @crunchyroll7734
    @crunchyroll77345 ай бұрын

    I love this video, thanks

  • @davidgutierrez731
    @davidgutierrez7316 ай бұрын

    Good job ,

  • @AbouTto_
    @AbouTto_6 ай бұрын

    Great

  • @bayloruniversity5812
    @bayloruniversity58126 ай бұрын

    Excellent explanation! Thank you for making this video!

  • @stevepolk4080
    @stevepolk40806 ай бұрын

    Central heat not heating, turn on it blow cool air want heat, element sensor honey well AC and Heat unit

  • @RaRaCruz
    @RaRaCruz6 ай бұрын

    My cadet electric wall heater was working just fine. All out of the blue it just started blowing cold air. The fan blows. Tested thermostat and works. Kicks in when i set it at warmer temp but just blows cold. I hit reset button, didn’t work, i reset the circuit breaker, no change. Is there a way to fix it or do i have to go buy a new one?

  • @betorangel4647
    @betorangel46476 ай бұрын

    New to your show wondering how can I get a blueprint of the wiring on the heat element?

  • @smoky407cdd
    @smoky407cdd7 ай бұрын

    So why would it blow cold when heat is on

  • @coltonadams9309
    @coltonadams93097 ай бұрын

    this was helpful in some ways and added questions for me. i have a similar unit that wont fire the element but the blower comes on as soon as i turn on the thermostat. ive replaced the thermostat, the sequencer, the limit switch wired to the element and the element itself. i only wait about 20 seconds of the the blower running and the element not firing before i shut the unit down again. Am i not waiting long enough or is something backwards?

  • @davisfox2170
    @davisfox21707 ай бұрын

    Golden advice!

  • @Jeremy-vb6tv
    @Jeremy-vb6tv8 ай бұрын

    I gotta check mine. Something is popping and switching intermittently causing the blower to run when it's not supposed to, or not expected to.

  • @kellyharris8970
    @kellyharris89709 ай бұрын

    Broke down perfectly! Thank you

  • @realSamAndrew
    @realSamAndrew9 ай бұрын

    If you have the heat strips running at the same time as the A/C, what would be the symptoms? Would you have super high pressure readings on both the high and low sides, making it appear overcharged? And would your delta T indoors be cool but lower than normal?

  • @ntexashvac7240
    @ntexashvac72409 ай бұрын

    Usually In a conventional air handler the heat strips are down stream of the coil so as far as your pressures are concerned they will look to be normal. The delta -T will be low because the cooled air will be heated downstream by the electric heat. The fastest way to diagnose a stuck on heat strip in the cooling months is to amp clamp the line voltage at the air handler while your set to cool. The blower only pulls a few amps so if your getting amp readings like 15amps and higher then you have a strip on. Each strip typically pulls about 20amps but some are a bit lower. But no blower is pulling 15+ amps under normal operation.

  • @realSamAndrew
    @realSamAndrew9 ай бұрын

    @@ntexashvac7240 great info, thanks. I briefly checked a PACKAGE unit last week for a neighbor, only had time for a quick check, high side 507 PSI, low side 170 (r410a). Told them it was overcharged, didn't think to check the heat kit. Heat kit was only installed last year, system is 5 years old. Condenser coil is clean. Delta t is only 9-12 degrees. Been going around my head to check the heat strips, but haven't been back. Could it be anything else besides severely overcharged?

  • @ntexashvac7240
    @ntexashvac72409 ай бұрын

    Yea it could be the TXV if it’s a TXV coil or possibly restriction. I would check the evap coil for even temperature across the coil

  • @randynBroncos
    @randynBroncos Жыл бұрын

    Hi, what gauge wiring is needed for wiring the heat sequencers? Is 10 gauge good enough for the sequencers in the furnace?

  • @christopherlucas6209
    @christopherlucas6209 Жыл бұрын

    Reasons sequencer type of switch is used is to limit the initial current to the heat strip. One stage heat strip dose not need or use sequencer....ad a second stage ....then you need the sequencer because the initial current draw would be way to large

  • @benbrewer5853
    @benbrewer5853 Жыл бұрын

    What do you call the thing the voltage staying there next to the heat sequencer

  • @antonionibarillas8255
    @antonionibarillas8255 Жыл бұрын

    Help a lot thank you

  • @arturppalacios4114
    @arturppalacios4114 Жыл бұрын

    I have problem ido not why tranformer burnet evrytime when turn on

  • @andredsouza2320
    @andredsouza2320 Жыл бұрын

    Thank you for the video. I have an issue with my furnace and I was wondering if you could could offer some assistance? I just uploaded it on my channel: kzread.info/dash/bejne/dZmassupiq_VgbA.html

  • @andredsouza2320
    @andredsouza2320 Жыл бұрын

    Thank you for the helpful videos. I've run into an issue with my electric furnace that happens atleast once ever couple of days: The thermostat will call for heat, but the furnace never comes on. While testing, the only way i've gotten it to work again is jumping the fan wires (R & G) for a second or two. 5 seconds after I do that, the furnace will kick on again and go off at the specified temperature. Do you know what could be causing this and how to troubleshoot? Last time this happened, jumping R and W did not work.

  • @zachosborne6577
    @zachosborne6577 Жыл бұрын

    Find where the power starts and follow it til it stops, then out what’s stopping it

  • @tonyshepherd4738
    @tonyshepherd4738 Жыл бұрын

    I get lost on verifying the sequencer is good. Amy videos on testing them?

  • @Alex-jo2oi
    @Alex-jo2oi Жыл бұрын

    Blower motor wouldn’t kick on. I tested resistance in the windings and they read fine. I’m starting to believe it’s the fan delay relay stuck in the open position

  • @chizo5097
    @chizo5097 Жыл бұрын

    That was a good video 👍 can you please make a video of reasons why fuse links blow up

  • @shirokuma2000
    @shirokuma2000 Жыл бұрын

    I work on these kinds of units im glad i found this video

  • @karljones1905
    @karljones1905 Жыл бұрын

    I've got one like that brand new and just stopped working I changed fuse checked all connections there fine.any hints

  • @jkajmtdblct1
    @jkajmtdblct1 Жыл бұрын

    You're amazing, thank you for your very easy to understand explanations. 👍

  • @MsFishingdog
    @MsFishingdog Жыл бұрын

    Great video.

  • @dallascowboys2757
    @dallascowboys2757 Жыл бұрын

    Would the heat sequencers effect my blower ? Weird situation so the emergency heat strips would work , fan would work , but as soon as I put it in on heat pump blower would run then stop and make a super loud noise

  • @jamesmiller7148
    @jamesmiller7148 Жыл бұрын

    I have a ? Heater comes on blows cold the after a few gets hot

  • @donaldpainter956
    @donaldpainter956 Жыл бұрын

    Went on a call today the homeowner had a new ecobee tstat installed he said now it says the auxiliary heat stays on so I thought they put the white wire in the wrong place but no it was saying auxiliary heat on but really the tstat wouldn't bring the strips on even set to emergency heat I put a Honeywell t8000 tstat on everything worked as it is supposed to

  • @scjbenify
    @scjbenify Жыл бұрын

    👍🏻

  • @caseyjarvis2842
    @caseyjarvis2842 Жыл бұрын

    I was In till you lost me at power out of the heat strip on a 220 element said to my self 👀

  • @wannis100
    @wannis100 Жыл бұрын

    Hello Great educational video. thank you very much for your help. I have a question about the low voltage wiring diagram. If we have installed a 24HX5 fan coil with a Goodman Heat Pump Condenser how we may wire the fan coil without a heat strip making it a heat pump system? Please Help Thank You

  • @reinaldolopez3197
    @reinaldolopez3197 Жыл бұрын

    you gave me some info i needed about sequencers.. im going to school for hvac 5 months in. thank you for the info.greatly appreciate it

  • @dogbone1065
    @dogbone10652 ай бұрын

    Don't they teach you that in school?

  • @johnowens5207
    @johnowens5207 Жыл бұрын

    So basically if you’re a DIY kinda person cut the power. Take pictures, Swap like for like?

  • @HsingSun
    @HsingSun2 жыл бұрын

    Thank you very much for your video. After I replaced these three items: Time-Delay, Fan-Relay, and Contactor (outside). Still, my AC cooling system keeps running and cannot be stopped. Question: Does Sequencer relate to fan-relay and cooling systems?

  • @tenncutt
    @tenncutt2 жыл бұрын

    Got a furnace with no control/circuit board that blew a transformer (no fuse) replaced transformer and added fuse and blows the fuse instantly when i turn the power on! Any thoughts?

  • @ntexashvac7240
    @ntexashvac72402 жыл бұрын

    Low voltage short in thermostat wire most likely. Disconnect all thermostat wires from the furnace then replace the fuse and try again. If it doesn’t blow then you’ll need to track down the short in the low voltage thermostat wires

  • @joshsmith8000
    @joshsmith80002 жыл бұрын

    How do you program a new module? Is there something else to buy?

  • @ntexashvac7240
    @ntexashvac72402 жыл бұрын

    Are asking how to program a new module for the Azure motor? Or are you asking how to program a new module for a factory motor?

  • @fovtheend2291
    @fovtheend22912 жыл бұрын

    So I moved in to this mobile home I made a complaint about this furnace inside my 90 days but the dude they paid to fix it left me with this. The lower elements are unhooked.. I cant seem to find the wiring diagram for this furnace. Was hoping for a little help.

  • @ntexashvac7240
    @ntexashvac72402 жыл бұрын

    Post model and serial number as well as make and I’ll see what I’ve got

  • @mikow.standingbear9274
    @mikow.standingbear92742 жыл бұрын

    What are the symptoms if a sequencer is stuck on?

  • @ntexashvac7240
    @ntexashvac72402 жыл бұрын

    The heat strips will constantly be on. If you have and amp clamp meter you can clamp the high voltage wires and look for amp draw. Anything about 1-5 amps will Indícate a strip is on. Typically 15-20 amps per strip

  • @johnnywells9319
    @johnnywells93192 жыл бұрын

    I need a more detailed wiring .

  • @dc5duben96
    @dc5duben962 жыл бұрын

    learned alot from this video, thanks!