Saludos, creo a mi experiencia armando tableros de control, que debiste usar un gabinete mas grande, no hay mucho espacio entre los dispositivos de fuerza, y el variador de frecuencia Delta no dejaste el espacio para su enfriamiento a como lo específica el manual de instalación, los cables no están marcados 😢y así varias observaciones 😮...
@mindaugasv853 күн бұрын
It's ok with cooling for our climate zone - no issues. The requirements are calculated for max enviroment temperature, for fully load VFD (max currennt), for long continuos running. For really I never had VFD overheating alarm in any project 😉 I add labels just on those wires where it's complicated to replace bad component without wire labels (f.e. vfd control signals). All others are just wasting of resources. Stop playing this "mouse games" when trying to find the issues. If you will pay attention to components labels, you will find components are in groups, f.e. power line 1F1-1DK1-1X1. Control switch 1Sa1.
@kieranjones496313 күн бұрын
Great to see you back on KZread! Was gutted when your videos disappeared!
@flinton0322 күн бұрын
Very clean and professional work.Bravo
@flinton0322 күн бұрын
Nicer , in which country this factory located ?
@mindaugasv8518 күн бұрын
Lithuania (EU), Earth, Solar system, Milky way galaxy, Universe (no name) 😉😂
@NorbaHouseАй бұрын
congratulations! As always, good explanation with great examples. I don't want to be boring, but if you have an example of a temperature PID with a recipe, I would really appreciate it. I intend to automate a laminated glass oven. Thanks!! forgive the English, I'm Brazilian and I'm using a translator.
@mindaugasv85Ай бұрын
I have never did PID with Delta PLC, only with Siemens. But if you have an option to select, use AS series PLC, not DVP - I have heard DVP series PLC has some bugs on some PID types (this information also is old, so maybe bugs have been fixed). P.S. you can write in any language - there's a translate button so I will understand 😉
@eugeneberdnik6295Ай бұрын
More!Sir, more videos about PLC programming:)
@NorbaHouseАй бұрын
Feliz que voltou com o canal. Suas explicações e exemplo de montagem de caixas são excelentes. Parabéns pelo bom trabalho.
@martnreda8549Ай бұрын
I was searching a lot for your old channel I was enjoying your old videos❤
@manolete19Ай бұрын
What software do you use for designing? Could you share the design process?
@frm60182 ай бұрын
does delta have modifications with the ability to program on structured text?
@mindaugasv85Ай бұрын
Depends on PLC (some of them has) and software. You can test - software is free. WPLsoft (don't recommen to use this...), ISPsoft (for PLC) or DIAstudio (all in one, like TIA portal). For DIA studio you need to register but it is still free.
@alobalo37962 ай бұрын
I hope if you can explain wiring
@pawegorzan50482 ай бұрын
Nice movie, as always😃👍
@bennaidjatarek5632 ай бұрын
Nice work 😊
@mindaugasv852 ай бұрын
Thanks 😄
@alpha_centaurus53962 ай бұрын
Good work bro
@alexsikorskyzero2 ай бұрын
😍👍
@mahercontrol56963 ай бұрын
good nice ❤
@mindaugasv853 ай бұрын
Thanks ✌
@josvandiepen34253 ай бұрын
Green and Yellow colors are not allowed for wiring inside cabinets. Geen/Yellow is for PE/EARTH wire in Europe.
@mindaugasv853 ай бұрын
Don't panic - it's GROUNDED 0VDC 5:24
@josvandiepen34253 ай бұрын
It's not allowed to use metal screws inside the cable conducts. You must use plastic or nylon. NORM EN60204.
@mindaugasv853 ай бұрын
Can you please show me where in internatiol standard they are writing about this? I doubt very much that this was discussed in this standard. Another thing, the standard is constantly being updated, sometimes there are stupid requirements in it, which are then withdrawn or rephrased. While talking about wire colors, the standard is very old and dumb: they just separated high voltage (black) from safe voltage (blue) and possible voltage when machine is powered off (orange). Also ground (G+Y). But these color standard is very old and in many situations are not helpful. Many companies produce control panels by their own wire color standards (I periodically check this while I see new machines in the factories). I have my own standard too, which is very helpful for debuging or expanding the system: L - black, N - blue, PE - gy. 24VDC - red, 0VDC - green. 24VDC from safety device (relay or contactor) - purple. 24V signala: pnp type - white, npn type - grey. Dry contacts (interlock) - orange. Other control voltage levels - brown, f.e. in 5VDC system, analog voltage signal and so on... So technically I am close to IEC standard. The different is in control (safe!) voltage part. And I am adding labels inside the control panel about the wires colors.
@stk54523 ай бұрын
Не могли бы вы предоставить схему блока управления?
@mindaugasv853 ай бұрын
Hello, the drawings are useless for you - it's non standard machine + production line. There's no reason to share it 😉
@stk54522 ай бұрын
@@mindaugasv85 I would just like to study it, I'm a beginner.
@tamaspekar2999Ай бұрын
@@mindaugasv85Even if it's not standard, I could also appriciate if you upload them. As a begginer it's good to see useful techniques 😉
@FedeTimpano3 ай бұрын
Nice job dude, please keep it up
@TS-rs8mx3 ай бұрын
Відразу видно, що людина любить свою роботу і отримує від неї задоволення.
@pawegorzan50483 ай бұрын
I love your movies😍
@mindaugasv853 ай бұрын
Thanks!
@davesteer12284 ай бұрын
I have been designing, wiring and writing software for control panels for 30+ years. Self tapping screws - fast, easy, cheap but not professional. Drill tap always the best route. No wire ID. Good luck fault finding this one. Component ID on device. What if device is changed? Low voltage directive states component IDs not on device or on trunking lid. Not sure if Wago terminals, looks like a cheap alternative. No attempt at segregation between ELV and mains voltage. Where was the electrical safety test? Looks like it was just turned on and hope it doesn't catch fire.
@mindaugasv854 ай бұрын
Thank you for your profesional opinion! It looks like you stuck in 90s with your standards 😁
@franciscovillamea6444 ай бұрын
Hello, what happened with your previous videos? I have been watching your channel for a long time and I remember other videos you had that were very good
@mindaugasv854 ай бұрын
Old channel has been deleted. I have uploaded only few old videos - I don't have more ☹️ Also for some "political" reasons I can't upload everything.... Even now I have many video data but just can't share in public 😬
@1966sanya4 ай бұрын
Sveiki. Ar tik surinkinėjate ar ir projektuojate?
@mindaugasv854 ай бұрын
Labas. Dirbu vienas. Pilnai visa automatika: projektavimas, surinkimas, instaliavimas, programavimas
@ArtcomeCi5 ай бұрын
Ačiū uz video . Kokius mokslus esat baiges ? ka teko studijuoti ? kur papildomai mokindavotes ? KZread ? Knygos ?
@mindaugasv854 ай бұрын
Kauno kolegija. Knygos tai saviugdos, nieko apie technika 😁 Keiciu darbovietes kas ~3 metus - geras budas igaut praktikos is skirtingu saltiniu 😂
@ArtcomeCi4 ай бұрын
@@mindaugasv85 Super . Ačiū .
@yevheniiyevhenii53965 ай бұрын
nice job
@mindaugasv854 ай бұрын
Thanks!
@ArtcomeCi5 ай бұрын
Ačiū už video . 👊 Gal pasidalintum kur rasti medžiagos kur būtu aprašyta kaip tarpusavyje jungiasi visi skydelyje esantys komponentai ? Mokinuosi elektrika ir labai daug kur paviršutiniškai viskas dėstoma ir trūksta informacijos prie skydelių surinkimo technologijos .
@mindaugasv855 ай бұрын
Tai renki pagal projektą :) O projektuot išmoksi jau su laiku. Bet vardan smalsumo, tai sakyčiau pasiimk kokio dažnio keitiklio (VFD) aprašymą ir pasianalizuok niuansus, "wirind diagram", parametrizavimą... Aš kai pradėjau dirbt, tai labai daug tų manual'ų perskaitęs, dalį jų taip gana nuoširdžiai. Nesvarbu, kad su laiku pamiršti, bet bent jau galvoj išlieka, kad galima ir "taip anaip" padaryt, o kai bus poreikis kaip tiksliai daryt jau rasi aprašyme.
@mindaugasv855 ай бұрын
Jei kalbant apie patį projektavimo principą, tai sakyčiau pagrindiniai 3 punktai: Jėgos grandinė; Saugos grandinė (safety); Valdymo grandinė.
@ArtcomeCi5 ай бұрын
@@mindaugasv85 Super . Ačiū už info 👊
@ArtcomeCi5 ай бұрын
Ačiū už idomu video 👊
@FedeTimpano5 ай бұрын
After a long time I found your channel again!! Greetings from Argentina
@makovled6 ай бұрын
Sveiki! Jeskau darbo automatikos skydu surinkimo sferoj . Gal jums reikia pagalbos?
@mindaugasv855 ай бұрын
Labas. Kad aš vienas dirbu, o skydų surinkimas yra gana maža viso ko dalis 🙂 Tai kol kas išsiverčiu vienas
@bennaidjatarek5636 ай бұрын
NICE WORK
@pawegorzan50486 ай бұрын
Nice machine. Did you solve the issue with the horizontal motor and brake resistor overheating?
@mindaugasv856 ай бұрын
It is not overheating - it's just hot 🙂 But the customer is going to replace the motor+drive, I think it will be 1kW.
@pawegorzan50486 ай бұрын
Another nice video. Are the servos canopen controlled? I have noticed kinco hmi, which you assembled in few control boxes. What do you think about them? Could you compare them to Delta or Weintek?
@mindaugasv856 ай бұрын
Yes, servo on canopen. These Kinco HMIs are from old control panels, they are about 10 years old. So I am using old Kinco HMIware soft. I think Kinco HMIs are high quality, never had them failed. I have used maybe about 40-50 these HMI. Only 2 were mechanically broken. If I would compare Delta DOP100 series, the soft of Delta is more user friendly. But Kinco is cheaper 😉
@pawegorzan50486 ай бұрын
Welcome back Midaugas, I have been lookig for your movies😄
@mahercontrol56967 ай бұрын
❤❤❤❤ nice
@Ahmed-sv1zr7 ай бұрын
Nice
@boolve7 ай бұрын
Didžiulė karvė.
@rabahbelmiloud41947 ай бұрын
good work bro
@mindaugasv857 ай бұрын
Many many thanks
@rabahbelmiloud41947 ай бұрын
happy that you are back, welcome back bro, keep up
@rabahbelmiloud41947 ай бұрын
please would you repost the old videos , i learned a lot from you, by the way i dont use delta devices instead i use siemens
@mindaugasv857 ай бұрын
I have uploaded what I had. Others are lost forever... Sorry 😬
@rabahbelmiloud41947 ай бұрын
its been a long time Mndagause , where is your old youtube channel, i used to flow every video you make, it was full of videos,
@hamidkhar68578 ай бұрын
I like your work
@othmanothman11168 ай бұрын
👏👏👏
@abderaoufsetti93688 ай бұрын
welcome back sir , we missed your videos ☺
@mindaugasv858 ай бұрын
Glad to hear that!
@MantasAutomation8 ай бұрын
Labai patinka tavo video, pats labai dažnai randu ką pasimokyti ir pritaikyti projektuose! Turiu ir keletą klausimų. Pastebėjau, kad dažnai nenaudoji komunikacijų VFD valdymui - gal taip pigiau, nes galima atsisakyti komunikacijos modulių ir pan., tačiau ženkliai sumažintų montavimo darbus. Dar įdomu dėl EMI/RFI filtrų VFD įėjime - kodėl jų nenaudoji? Gal taip pat dėl kainos ar tiesiog nereikalauja užsakovas?
@mindaugasv858 ай бұрын
Labas, Su komunikacija (RS485, modbus) gana nepatikima - jei daugiau VFD tai lagina duomenų perdavimas. Kai kuriuose procesuose tai kritiškai svarbu. Kažkada ir su Elinta tuo klausimu kalbėjau - sakė ir jų inžinieriai VFD valdo per diskretinius, per komunikaciją tai nebent greičius nusisiunčia iš anksto užduotus, seka apkrovas ir t.t... Nu toks RS485 modbus principas - per vieną užklausą tik kelis wordus gali nusiųsti/gauti. CanOpen, Ethercat, Profinet... tų problemų neturi. Bet tuo pačiu tai papildomi pinigai įrangoje (PLC, VFD). O gedimo atveju su diskretiniais greičiau susitvarkoma - galima ir kitą VFD modelį panaudot. Retai kas tuos filtrus ant įėjimo stato, čia jau kai problemų atsiranda, tai tada pradeda ieškot tų sprendimų, ko pasekoje ir filtrai atsiranda. Pagal ES direktyvas, "filtravimas" privalo būti, kad neterštų įvadinio tinklo. Nors kai kurie VFD tuos filtrus turi integruotu, bet turbūt ne biudžetinė klasė. Šiaip seniai tuo klausimu besidomėjau: tiesiog uždariau vieną dieną tą klausimą - likau prie to standartinio "kai atsiras poreikis, tai įdėsiu". Didžioji dalis projektų yra klientų sprendimai: tokia ir tokia įranga ir t.t... Ir visi taupo. T.y. aš daugiausiai dirbu su tais, kurie gamina įrenginius, o ne galutiniais vartotojais. Tai dažniausiai jie jau žino*** ko reikia 😁
@SvenEdits8 ай бұрын
wow your control cabinets look like they do here in Germany 😍 good video
@mindaugasv858 ай бұрын
Thank you! P.S. I assembly them in garage 😅
@Ahmed-sv1zr9 ай бұрын
Nice
@mindaugasv859 ай бұрын
Thanks!
@mahercontrol56969 ай бұрын
Hey, you guys have any other channels. I'm looking for your old movies.
@mindaugasv859 ай бұрын
Hi, Old channel has been deleted ~2 years ago. Sorry for that... I only have 3 old videos, 2 of them are uploaded (cba5, cba6). The last one is modbus rtu vs ascii - data lag test. I will upload it asap. What videos are you looking for?
@mahercontrol56969 ай бұрын
@@mindaugasv85 I was so upset that all your movies were beautiful.😢😢
@mahercontrol56969 ай бұрын
@@mindaugasv85I'd love to see those films again.
@mindaugasv859 ай бұрын
Can't do anything now: I uploaded everything I had. The good thing is that the channel is here and I'm going to make more videos 😉
@mahercontrol56969 ай бұрын
@@mindaugasv85 Hi. Thank you, my friend.
@SvenEdits10 ай бұрын
nice video where are you from?
@mindaugasv859 ай бұрын
Lithuania (EU) 😉
@boolve10 ай бұрын
At 2:20 you mentioned you have got a double stop button. Is it because of some sort of backup circuit or it really does disable other parts of the system? And what is the reason that you have removed the second set of contacts in your demonstration?
@mindaugasv8510 ай бұрын
It's safety system (cat2, 3 or 4). That means e.stop should work if one contact fail and it will be not possible to activate it until you will not fix it. So I have removed 1 contact because I needed to keep it in closed state - failure simulation.
Пікірлер
Saludos, creo a mi experiencia armando tableros de control, que debiste usar un gabinete mas grande, no hay mucho espacio entre los dispositivos de fuerza, y el variador de frecuencia Delta no dejaste el espacio para su enfriamiento a como lo específica el manual de instalación, los cables no están marcados 😢y así varias observaciones 😮...
It's ok with cooling for our climate zone - no issues. The requirements are calculated for max enviroment temperature, for fully load VFD (max currennt), for long continuos running. For really I never had VFD overheating alarm in any project 😉 I add labels just on those wires where it's complicated to replace bad component without wire labels (f.e. vfd control signals). All others are just wasting of resources. Stop playing this "mouse games" when trying to find the issues. If you will pay attention to components labels, you will find components are in groups, f.e. power line 1F1-1DK1-1X1. Control switch 1Sa1.
Great to see you back on KZread! Was gutted when your videos disappeared!
Very clean and professional work.Bravo
Nicer , in which country this factory located ?
Lithuania (EU), Earth, Solar system, Milky way galaxy, Universe (no name) 😉😂
congratulations! As always, good explanation with great examples. I don't want to be boring, but if you have an example of a temperature PID with a recipe, I would really appreciate it. I intend to automate a laminated glass oven. Thanks!! forgive the English, I'm Brazilian and I'm using a translator.
I have never did PID with Delta PLC, only with Siemens. But if you have an option to select, use AS series PLC, not DVP - I have heard DVP series PLC has some bugs on some PID types (this information also is old, so maybe bugs have been fixed). P.S. you can write in any language - there's a translate button so I will understand 😉
More!Sir, more videos about PLC programming:)
Feliz que voltou com o canal. Suas explicações e exemplo de montagem de caixas são excelentes. Parabéns pelo bom trabalho.
I was searching a lot for your old channel I was enjoying your old videos❤
What software do you use for designing? Could you share the design process?
does delta have modifications with the ability to program on structured text?
Depends on PLC (some of them has) and software. You can test - software is free. WPLsoft (don't recommen to use this...), ISPsoft (for PLC) or DIAstudio (all in one, like TIA portal). For DIA studio you need to register but it is still free.
I hope if you can explain wiring
Nice movie, as always😃👍
Nice work 😊
Thanks 😄
Good work bro
😍👍
good nice ❤
Thanks ✌
Green and Yellow colors are not allowed for wiring inside cabinets. Geen/Yellow is for PE/EARTH wire in Europe.
Don't panic - it's GROUNDED 0VDC 5:24
It's not allowed to use metal screws inside the cable conducts. You must use plastic or nylon. NORM EN60204.
Can you please show me where in internatiol standard they are writing about this? I doubt very much that this was discussed in this standard. Another thing, the standard is constantly being updated, sometimes there are stupid requirements in it, which are then withdrawn or rephrased. While talking about wire colors, the standard is very old and dumb: they just separated high voltage (black) from safe voltage (blue) and possible voltage when machine is powered off (orange). Also ground (G+Y). But these color standard is very old and in many situations are not helpful. Many companies produce control panels by their own wire color standards (I periodically check this while I see new machines in the factories). I have my own standard too, which is very helpful for debuging or expanding the system: L - black, N - blue, PE - gy. 24VDC - red, 0VDC - green. 24VDC from safety device (relay or contactor) - purple. 24V signala: pnp type - white, npn type - grey. Dry contacts (interlock) - orange. Other control voltage levels - brown, f.e. in 5VDC system, analog voltage signal and so on... So technically I am close to IEC standard. The different is in control (safe!) voltage part. And I am adding labels inside the control panel about the wires colors.
Не могли бы вы предоставить схему блока управления?
Hello, the drawings are useless for you - it's non standard machine + production line. There's no reason to share it 😉
@@mindaugasv85 I would just like to study it, I'm a beginner.
@@mindaugasv85Even if it's not standard, I could also appriciate if you upload them. As a begginer it's good to see useful techniques 😉
Nice job dude, please keep it up
Відразу видно, що людина любить свою роботу і отримує від неї задоволення.
I love your movies😍
Thanks!
I have been designing, wiring and writing software for control panels for 30+ years. Self tapping screws - fast, easy, cheap but not professional. Drill tap always the best route. No wire ID. Good luck fault finding this one. Component ID on device. What if device is changed? Low voltage directive states component IDs not on device or on trunking lid. Not sure if Wago terminals, looks like a cheap alternative. No attempt at segregation between ELV and mains voltage. Where was the electrical safety test? Looks like it was just turned on and hope it doesn't catch fire.
Thank you for your profesional opinion! It looks like you stuck in 90s with your standards 😁
Hello, what happened with your previous videos? I have been watching your channel for a long time and I remember other videos you had that were very good
Old channel has been deleted. I have uploaded only few old videos - I don't have more ☹️ Also for some "political" reasons I can't upload everything.... Even now I have many video data but just can't share in public 😬
Sveiki. Ar tik surinkinėjate ar ir projektuojate?
Labas. Dirbu vienas. Pilnai visa automatika: projektavimas, surinkimas, instaliavimas, programavimas
Ačiū uz video . Kokius mokslus esat baiges ? ka teko studijuoti ? kur papildomai mokindavotes ? KZread ? Knygos ?
Kauno kolegija. Knygos tai saviugdos, nieko apie technika 😁 Keiciu darbovietes kas ~3 metus - geras budas igaut praktikos is skirtingu saltiniu 😂
@@mindaugasv85 Super . Ačiū .
nice job
Thanks!
Ačiū už video . 👊 Gal pasidalintum kur rasti medžiagos kur būtu aprašyta kaip tarpusavyje jungiasi visi skydelyje esantys komponentai ? Mokinuosi elektrika ir labai daug kur paviršutiniškai viskas dėstoma ir trūksta informacijos prie skydelių surinkimo technologijos .
Tai renki pagal projektą :) O projektuot išmoksi jau su laiku. Bet vardan smalsumo, tai sakyčiau pasiimk kokio dažnio keitiklio (VFD) aprašymą ir pasianalizuok niuansus, "wirind diagram", parametrizavimą... Aš kai pradėjau dirbt, tai labai daug tų manual'ų perskaitęs, dalį jų taip gana nuoširdžiai. Nesvarbu, kad su laiku pamiršti, bet bent jau galvoj išlieka, kad galima ir "taip anaip" padaryt, o kai bus poreikis kaip tiksliai daryt jau rasi aprašyme.
Jei kalbant apie patį projektavimo principą, tai sakyčiau pagrindiniai 3 punktai: Jėgos grandinė; Saugos grandinė (safety); Valdymo grandinė.
@@mindaugasv85 Super . Ačiū už info 👊
Ačiū už idomu video 👊
After a long time I found your channel again!! Greetings from Argentina
Sveiki! Jeskau darbo automatikos skydu surinkimo sferoj . Gal jums reikia pagalbos?
Labas. Kad aš vienas dirbu, o skydų surinkimas yra gana maža viso ko dalis 🙂 Tai kol kas išsiverčiu vienas
NICE WORK
Nice machine. Did you solve the issue with the horizontal motor and brake resistor overheating?
It is not overheating - it's just hot 🙂 But the customer is going to replace the motor+drive, I think it will be 1kW.
Another nice video. Are the servos canopen controlled? I have noticed kinco hmi, which you assembled in few control boxes. What do you think about them? Could you compare them to Delta or Weintek?
Yes, servo on canopen. These Kinco HMIs are from old control panels, they are about 10 years old. So I am using old Kinco HMIware soft. I think Kinco HMIs are high quality, never had them failed. I have used maybe about 40-50 these HMI. Only 2 were mechanically broken. If I would compare Delta DOP100 series, the soft of Delta is more user friendly. But Kinco is cheaper 😉
Welcome back Midaugas, I have been lookig for your movies😄
❤❤❤❤ nice
Nice
Didžiulė karvė.
good work bro
Many many thanks
happy that you are back, welcome back bro, keep up
please would you repost the old videos , i learned a lot from you, by the way i dont use delta devices instead i use siemens
I have uploaded what I had. Others are lost forever... Sorry 😬
its been a long time Mndagause , where is your old youtube channel, i used to flow every video you make, it was full of videos,
I like your work
👏👏👏
welcome back sir , we missed your videos ☺
Glad to hear that!
Labai patinka tavo video, pats labai dažnai randu ką pasimokyti ir pritaikyti projektuose! Turiu ir keletą klausimų. Pastebėjau, kad dažnai nenaudoji komunikacijų VFD valdymui - gal taip pigiau, nes galima atsisakyti komunikacijos modulių ir pan., tačiau ženkliai sumažintų montavimo darbus. Dar įdomu dėl EMI/RFI filtrų VFD įėjime - kodėl jų nenaudoji? Gal taip pat dėl kainos ar tiesiog nereikalauja užsakovas?
Labas, Su komunikacija (RS485, modbus) gana nepatikima - jei daugiau VFD tai lagina duomenų perdavimas. Kai kuriuose procesuose tai kritiškai svarbu. Kažkada ir su Elinta tuo klausimu kalbėjau - sakė ir jų inžinieriai VFD valdo per diskretinius, per komunikaciją tai nebent greičius nusisiunčia iš anksto užduotus, seka apkrovas ir t.t... Nu toks RS485 modbus principas - per vieną užklausą tik kelis wordus gali nusiųsti/gauti. CanOpen, Ethercat, Profinet... tų problemų neturi. Bet tuo pačiu tai papildomi pinigai įrangoje (PLC, VFD). O gedimo atveju su diskretiniais greičiau susitvarkoma - galima ir kitą VFD modelį panaudot. Retai kas tuos filtrus ant įėjimo stato, čia jau kai problemų atsiranda, tai tada pradeda ieškot tų sprendimų, ko pasekoje ir filtrai atsiranda. Pagal ES direktyvas, "filtravimas" privalo būti, kad neterštų įvadinio tinklo. Nors kai kurie VFD tuos filtrus turi integruotu, bet turbūt ne biudžetinė klasė. Šiaip seniai tuo klausimu besidomėjau: tiesiog uždariau vieną dieną tą klausimą - likau prie to standartinio "kai atsiras poreikis, tai įdėsiu". Didžioji dalis projektų yra klientų sprendimai: tokia ir tokia įranga ir t.t... Ir visi taupo. T.y. aš daugiausiai dirbu su tais, kurie gamina įrenginius, o ne galutiniais vartotojais. Tai dažniausiai jie jau žino*** ko reikia 😁
wow your control cabinets look like they do here in Germany 😍 good video
Thank you! P.S. I assembly them in garage 😅
Nice
Thanks!
Hey, you guys have any other channels. I'm looking for your old movies.
Hi, Old channel has been deleted ~2 years ago. Sorry for that... I only have 3 old videos, 2 of them are uploaded (cba5, cba6). The last one is modbus rtu vs ascii - data lag test. I will upload it asap. What videos are you looking for?
@@mindaugasv85 I was so upset that all your movies were beautiful.😢😢
@@mindaugasv85I'd love to see those films again.
Can't do anything now: I uploaded everything I had. The good thing is that the channel is here and I'm going to make more videos 😉
@@mindaugasv85 Hi. Thank you, my friend.
nice video where are you from?
Lithuania (EU) 😉
At 2:20 you mentioned you have got a double stop button. Is it because of some sort of backup circuit or it really does disable other parts of the system? And what is the reason that you have removed the second set of contacts in your demonstration?
It's safety system (cat2, 3 or 4). That means e.stop should work if one contact fail and it will be not possible to activate it until you will not fix it. So I have removed 1 contact because I needed to keep it in closed state - failure simulation.