Norm and Eric's passions surround mentoring and coaching any candidate willing to learn about plumbing, gasfitting, codes, regulations, public safety and doing things right the first time. Norm, Eric and the TPA-on-line Tech. Team have developed this site to assist you with identifying your strength and weaknesses as apprentices proceed through their apprenticeship and journeyman advance to masters learning about the plumbing and gasfitting trade.
Who does it Help:
Although this site is focused towards apprentice and journeyman plumbers and gas-fitters preparing for licensing examinations it is also extremely beneficial for high school student interested in pursuing a career in the trades, the novice, or building professional.

Water Closets - AKA-Toilets

Water Closets - AKA-Toilets

Пікірлер

  • @larrytheplumber9851
    @larrytheplumber985127 күн бұрын

    It's a damn pipe threader lol

  • @andrewlaubi4448
    @andrewlaubi44482 ай бұрын

    Totally useless

  • @jamesadams4486
    @jamesadams44865 ай бұрын

    what is around it dirt? Thanks now let see you replace it!

  • @michaelsimsplaya4199
    @michaelsimsplaya4199 Жыл бұрын

    Abdul valve pdf

  • @alcapirobi2915
    @alcapirobi2915 Жыл бұрын

    No air gap!!!

  • @kruulz
    @kruulz Жыл бұрын

    Hi there. I'm a plumber in NYS (not the city). Do your teachings regarding codes apply to me in my area?

  • @R.R.Z.
    @R.R.Z. Жыл бұрын

    What paint do you use?

  • @bkoz319
    @bkoz319 Жыл бұрын

    well if you cant make turns with the flexible gas connector then every gas stove in america is wrong...they are all folded up when you push the stove back in

  • @ArchinatorWC88
    @ArchinatorWC88 Жыл бұрын

    Thank you. Could you perhaps speak more about the extent of application and whats going on here exactly?

  • @lawrenceoleary4589
    @lawrenceoleary4589 Жыл бұрын

    I guess that's a nice way of saying, WTF. One pipe diameter smaller. so half inch x 7? this video needs clarified

  • @frankdatank0101
    @frankdatank0101 Жыл бұрын

    LOVE THE VIDEOS and learning so much. I have a unique question on vacuum relief valves and whether they can be used on cold water supply line for draining purposes. I have a seasonal shed that I have cold water line run to with a sink. The supply line to the shed can be drained to the basement to prevent freezing in winter temps. When I open the shed sink spigot, close the supply at the house and open my drain valve, a vacuum is still created that is beating my expected gravity drain :-). I can go disconnect the fittings in shed to get the water to drain. Can I install a vacuum relief valve at the highest point under shed sink on main line that would automatically do this for me once I shut off the supply and open the drain in basement?

  • @Chrominance87
    @Chrominance87 Жыл бұрын

    And they used ring hangers too! I never see that. Normally plumbers use that cheap looking strap iron.

  • @bko1300
    @bko1300 Жыл бұрын

    You say "Any time you have a flat bottom fixture that's tied onto a kitchen sink on the vertical, you have to change to 3 inch". I'm kind of confused about that and want to understand it. Is there a code reference you can point me to that will lay it out? Thanks!

  • @JimmyBackflow
    @JimmyBackflow2 жыл бұрын

    Water continuously discharges out of the relief valve if the second check valve is not drip tight and backpressure is present. If the second check valve is drip tight it will not discharge. Water will also continuously discharge out of the relief valve if the first check valve is not drip tight and there is no downstream demand. A drop in supply pressure will cause the relief to spit and stop.

  • @devilmonkey
    @devilmonkey2 жыл бұрын

    Says do you have any common sense. Solution, install a few pipe elbows along with it. Ah yes how obvious

  • @theplumbingacademyinc.2209
    @theplumbingacademyinc.22092 жыл бұрын

    Plumbers seem to be lacking common sense and situational awareness these days. Gas appliance connectors are frequently installed NOT incompliance with manufacturers instructions.

  • @pkitp353
    @pkitp3532 жыл бұрын

    Love the content. Been licensed for 6 years and still learning. Thanks for all the videos

  • @theplumbingacademyinc.2209
    @theplumbingacademyinc.22092 жыл бұрын

    Great to hear!

  • @williammorris3303
    @williammorris33032 жыл бұрын

    I was under the impression that you couldn’t lay a sanitary tee down?

  • @theplumbingacademyinc.2209
    @theplumbingacademyinc.22092 жыл бұрын

    It's a VENT. You can lay it on its back just like that.

  • @upstateplumbing9995
    @upstateplumbing99952 жыл бұрын

    Can you explain why that 5 minutes extra is needed?

  • @upstateplumbing9995
    @upstateplumbing99952 жыл бұрын

    I just do 15 mins just to be safe

  • @theplumbingacademyinc.2209
    @theplumbingacademyinc.22092 жыл бұрын

    It is code compliance in Massachusetts

  • @brunoprimas1483
    @brunoprimas14832 жыл бұрын

    Stall urinals are still manufactured and installed to this day.

  • @theplumbingacademyinc.2209
    @theplumbingacademyinc.22092 жыл бұрын

    Not in Massachusetts, there is a history of stall urinals being used as floor drains and stall urinals are very unsanitary.

  • @brunoprimas1483
    @brunoprimas14832 жыл бұрын

    @@theplumbingacademyinc.2209 Interesting. I wonder how many states they are prohibited? I live in Wisconsin and they are still used in new construction.

  • @SarahMomSmith
    @SarahMomSmith2 жыл бұрын

    are these videos teaching IPC or UPC?

  • @theplumbingacademyinc.2209
    @theplumbingacademyinc.22092 жыл бұрын

    No. They are specific to Massachusetts-(a custom code). The original version adopted by Massachusetts in 1965 was the UPC with modifications and amendments. The current version of the Massachusetts Fuel Gas and Plumbing Code no longer resembles the original UPC 1965 version and stands alone on-its-own.

  • @80ivannoel
    @80ivannoel2 жыл бұрын

    Setup seems very unsafe, electric fixtures should be away from plumbing fittings and fixture.

  • @theplumbingacademyinc.2209
    @theplumbingacademyinc.22092 жыл бұрын

    This is a code compliant installation. It happens everyday

  • @upstateplumbing9995
    @upstateplumbing99952 жыл бұрын

    Is the water hammer arrester upside down?

  • @theplumbingacademyinc.2209
    @theplumbingacademyinc.22092 жыл бұрын

    Yes it is, but it does not effect the function

  • @bormorzx
    @bormorzx2 жыл бұрын

    Its a great pass or fail Norman. I do have a question about a sanitary T to be looking straight up and cut over! on the minute 4:33. The “cut over” meaning “turn the flat vent below ground on straight up Sanitary T”. But the vent ll be below the toilet flood level rim, right? So, the vertical Rise on 248 CMR 10.16 (7)(b) doesn’t apply for battery vents? If i'm right the 248 CMR 10:16 (7) (b) 2. a. apply for it? I hope u understand my question, Thanks.

  • @theplumbingacademyinc.2209
    @theplumbingacademyinc.22092 жыл бұрын

    Yes, I understand your question. In Massachusetts battery venting below the flood level rim, or below the weir of a trap can be performed in limited application and with very specific installation practices. Depending on the fixture, or fixtures being served; floor drains, mop receptor and similar fixtures can be vented below the flood level rim, or weir of the trap serving the fixture as long as the surface area of the fixture to be drain is no more than 144 sq. inches.

  • @upstateplumbing9995
    @upstateplumbing99952 жыл бұрын

    Blow down tubes are pvc here and pass code in Ithaca NY....

  • @theplumbingacademyinc.2209
    @theplumbingacademyinc.22092 жыл бұрын

    Interesting! PVC tubing has a maximum temperature rating-(usually around 180-Fahrenheit), this is well under the 210-Fahrenheit blow-off temperature of the relief valve setting on the water heater. At 210-Fahrenheit the PVC being used for the blow-off will become pliable, and in essence will melt-off rendering the relief valve dangerous and a significant scalding risk for anyone that may be in the area when a relief valve discharge occurs. It is so dangerous that the Commonwealth of Massachusetts passed a LAW-(following several incidents) that only allow the use of non-ferrous METAL tube or pipe to be used as the blow-off tube for T & P Valves.

  • @zbigniewbrzoza7056
    @zbigniewbrzoza70562 жыл бұрын

    Don't you need no hub adapters in your jurisdiction?

  • @theplumbingacademyinc.2209
    @theplumbingacademyinc.22092 жыл бұрын

    No - Hub adapters are not required when the I.D. and O.D. are the same

  • @chrisbrewer1403
    @chrisbrewer14032 жыл бұрын

    I did not think that this should have passed. The sanitary tee on its back as the vent

  • @theplumbingacademyinc.2209
    @theplumbingacademyinc.22092 жыл бұрын

    Sanitary Tees are permitted for use in the venting system as demonstrated in the video.

  • @adamroshia6596
    @adamroshia65962 жыл бұрын

    Slip couplings are useless

  • @theplumbingacademyinc.2209
    @theplumbingacademyinc.22092 жыл бұрын

    Absolutely

  • @fabrigasmaka8256
    @fabrigasmaka82562 жыл бұрын

    Thanks for this informative video.

  • @theplumbingacademyinc.2209
    @theplumbingacademyinc.22092 жыл бұрын

    Glad it was helpful!

  • @pkitp353
    @pkitp3532 жыл бұрын

    I’ve been deceitful on the marks a few times hopefully I can be forgiven :)

  • @theplumbingacademyinc.2209
    @theplumbingacademyinc.22092 жыл бұрын

    Shame shame!!! Going forward you will be more aware.

  • @givennameidk4515
    @givennameidk45152 жыл бұрын

    I really enjoy your videos keep them up!

  • @theplumbingacademyinc.2209
    @theplumbingacademyinc.22092 жыл бұрын

    Thanks, will do!

  • @larrytheplumber9851
    @larrytheplumber98512 жыл бұрын

    Good 👍 stuff

  • @theplumbingacademyinc.2209
    @theplumbingacademyinc.22092 жыл бұрын

    Thanks 👍

  • @givennameidk4515
    @givennameidk45152 жыл бұрын

    Does this follow upc code?

  • @theplumbingacademyinc.2209
    @theplumbingacademyinc.22092 жыл бұрын

    No. They are specific to Massachusetts-(a custom code). The original version adopted by Massachusetts in 1965 was the UPC with modifications and amendments. The current version of the Massachusetts Fuel Gas and Plumbing Code no longer resembles the original UPC 1965 version and stands alone on-its-own.

  • @rodneyrtennis1279
    @rodneyrtennis12792 жыл бұрын

    What codes are you referencing from? We are currently referencing UPC/UMC 2015🤦‍♂️

  • @theplumbingacademyinc.2209
    @theplumbingacademyinc.22092 жыл бұрын

    Massachusetts, which is a custom code

  • @theplumbingacademyinc.2209
    @theplumbingacademyinc.22092 жыл бұрын

    They are specific to Massachusetts-(a custom code). The original version adopted by Massachusetts in 1965 was the UPC with modifications and amendments. The current version of the Massachusetts Fuel Gas and Plumbing Code no longer resembles the original UPC 1965 version and stands alone on-its-own.

  • @rodneyrtennis1279
    @rodneyrtennis12792 жыл бұрын

    3' above within 10'

  • @theplumbingacademyinc.2209
    @theplumbingacademyinc.22092 жыл бұрын

    2-feet above or 10-feet away. It is not 10-feet away and 2-feet above.

  • @wallstgovernment
    @wallstgovernment2 жыл бұрын

    I do say that when I see after 30-40 years… this guy cared and gives me confidence the rest of the home is done properly upon repairs as well. 🤙🏽

  • @theplumbingacademyinc.2209
    @theplumbingacademyinc.22092 жыл бұрын

    Hello WallSt Government! That was the exact sentiment of our Instructor. In his career as an Inspector he found that work which demonstrated a high degree of craftsmanship indicated that the plumber was just as conscientious throughout the entire installation.

  • @zackhines2569
    @zackhines25692 жыл бұрын

    What state are you in?

  • @theplumbingacademyinc.2209
    @theplumbingacademyinc.22092 жыл бұрын

    Massachusetts.

  • @orbfather8105
    @orbfather81052 жыл бұрын

    Probably should go to jail - could be quote of 2022

  • @timothyking1688
    @timothyking16882 жыл бұрын

    Thank you for doing these videos. Great information.

  • @theplumbingacademyinc.2209
    @theplumbingacademyinc.22092 жыл бұрын

    Glad you like them!

  • @timothyking1688
    @timothyking16882 жыл бұрын

    Good video, Norm. Looking for the little details pays off.

  • @theplumbingacademyinc.2209
    @theplumbingacademyinc.22092 жыл бұрын

    Hello timothy king! Thank you for the kind words. You are absolutely correct. "Little details" often get overlooked. Sadly, overlooking details that some consider little can result in someone getting scalded, sick, or worse. After all "The Plumbers Protect The Health Of Our Nation"!

  • @richardgarcia3210
    @richardgarcia32102 жыл бұрын

    So you have to purchase a domain to enter this website?

  • @theplumbingacademyinc.2209
    @theplumbingacademyinc.22092 жыл бұрын

    Hello Richard Garcia! Thank you for taking the time to comment and for viewing our videos. Most of our main website, www.theplumbingacademy.com , should be accessible without without the use of credentials or payment. There are areas where access is restricted to enrolled students. We also offer practice plumbing and gas fitting tests to help measure knowledge of plumbing codes, plumbing math, drawings, sizing and other subjects. There is a charge for practice tests, but, sample tests are available for free.