Hyper Lyceum

Hyper Lyceum

This channel is for HyperLyceum.com and we are trying to provide tutorial videos for students.
Our goal is to provide opportunities for you to share your knowledge. For more information please contact: [email protected]

Пікірлер

  • @MoBen798
    @MoBen7989 күн бұрын

    Thank you for the interesting video, I have followed all the steps and all is OK and even the link is established for Abaqus files and not only shortcut. the command "abaqus info=system" works well and i see the Fortran compiler well set up. However, in the verifying step, I have an error

  • @somdebsar7378
    @somdebsar737810 күн бұрын

    you are the best!!

  • @anasouzzahra9858
    @anasouzzahra985822 күн бұрын

    I am trying to link Intel 2024 and Visual Studio 2019 with Abaqus 2021. Is that okay, or will there be a compatibility problem?

  • @amirloghmani5143
    @amirloghmani514325 күн бұрын

    Thank you, loved it. Right to the point 👌

  • @CompositesImdea
    @CompositesImdeaАй бұрын

    I get this error: ***ERROR: ELEMENT 771 INSTANCE PART-1-1 CANNOT BE ADDED USING *MODEL CHANGE IF IT IS NOT REMOVED OR INACTIVE IN THE PREVIOUS STEP ***NOTE: DUE TO AN INPUT ERROR THE ANALYSIS PRE-PROCESSOR HAS BEEN UNABLE TO INTERPRET SOME DATA. SUBSEQUENT ERRORS MAY BE CAUSED BY THIS OMISSION It seems like the deactivation is not being correctly performed. I double checked the pre-step and it is defined as you specify. Any hint on what could be the problem?

  • @CompositesImdea
    @CompositesImdeaАй бұрын

    Ok I found the problem. The python code defines an area wider than the one selected for the deactivation step

  • @ulrichbenash2338
    @ulrichbenash2338Ай бұрын

    hello I am a young enthusiast of fluid mechanics...I am doing a simulation regarding atmospheric flows and I would like to know how to write the C++ code to have the normal speed at the level of a patch and not throughout the domain...I tried everything but nothing I need help please

  • @sivaadapa9255
    @sivaadapa9255Ай бұрын

    how can i get first code

  • @zeinabmohammadi1379
    @zeinabmohammadi1379Ай бұрын

    Thanks for your insightful tutorial, best of luck to you too!

  • @saurabhkratos
    @saurabhkratosАй бұрын

    Thank you for the details. I followed every step as per the instructions. The abaqus info=system command shows that the link has been established. However, the verify command ends up in an error when checking for the subroutine. I would appreciate any help.

  • @jboy804
    @jboy804Ай бұрын

    2022 visual studio does NOT work, find and use 2019 version!

  • @user-eh1fe2ld8y
    @user-eh1fe2ld8y2 ай бұрын

    Hey, thank you very much for your vedio. I'm pretty sure that I had followed every step correctly. but when I verify my abaqus info(by using: abq2023 info=system), it showed : C++ Compiler: Unable to locate or determine the version of a C++ compiler on this system. If a C++ compiler is installed on this system, please load vcvars64.bat file before running Abaqus others are all correct. I checked other community, there are also some people have same problem with mine. I would like to ask that do you have any solution for this error? thank you!

  • @victorhu1264
    @victorhu12642 ай бұрын

    Hi thank you for the video. I followed every steps; however, my verification has failed instead of pass. I noticed that when I opened the command window, the prompt is C:\Windows\System32 instead of C:\temp. Could that be the reason? (When I use C:\Windows\System32\abaqus info=system in the command window, the results shows that my Fortran compiler has been linked but the verification failed). I’d appreciate your insights! Thank you! 🙏

  • @victorhu1264
    @victorhu12642 ай бұрын

    Also I’m using vs 2022, Intel oneAPI 2024, abaqus 2023.

  • @rahuljws7090
    @rahuljws70902 ай бұрын

    Hi, I followed the same procedure, but still i am facing error. I am trying to link the fortran with abaqus2023. linking part is ok. but verification part failed and giving errors. Please help me out. I am using VS2022 + Abaqus 2023 + latest version of oneAPI toolkits this is the error Verify test : Abaqus/Standard with user subroutines verification .. log located at C:\temp\verify\user_std\user_std.log result : ERROR : Abaqus/Standard with user subroutines verification ------------------------------------------------------------ Verify test : Abaqus/Explicit with user subroutines verification - 'Abaqus/Explicit single precision user subroutine' Failed. - 'Abaqus/Explicit double precision user subroutine' Failed. .. log located at C:\temp\verify\user_exp\user_exp.log result : ERROR : Abaqus/Explicit with user subroutines verification linking part C++ Compiler: Microsoft Visual C++ 14.39.33523.0 Linker Version: Microsoft (R) Incremental Linker Version 14.39.33523.0 Fortran Compiler: Intel Fortran Compiler 2021.12 MPI: MS-MPI 10.1.12498.18

  • @user-bq3ud8sw2t
    @user-bq3ud8sw2t2 ай бұрын

    Hi sir, thank you so much for sharing such type of very informative video. I am currently working on a simulation for thermo-mechanical analysis, when i go for mechanical analysis, getting this type of error; The volume of two elements is zero, small, or negative. Check coordinates or node numbering, or modify the mesh seed. In the case of a tetrahedron this error may indicate that all nodes are located very nearly in a plane. The elements have been identified in element set ErrElemVolSmallNegZero. Plz suggest a solution for it. Thank you.

  • @hehe19001
    @hehe190013 ай бұрын

    Verify test : Abaqus/Standard with user subroutines verification .. log located at C:\Windows\System32\verify\user_std\user_std.log result : ERROR : Abaqus/Standard with user subroutines verification How to fix this error?I have installed Vs2019+HPC&Base(2024.1)+Abq2023 for windows 10 pro

  • @hussainwaris2838
    @hussainwaris28383 ай бұрын

    Dear sir hope you are doing well Can you please help me to learn abaqus I'm also want to work on dental implants

  • @kiran-jh7ze
    @kiran-jh7ze3 ай бұрын

    when test is conducted for 10 seconds experimentally, why does simulation wont finish in 10 seconds

  • @kar-dt1hk
    @kar-dt1hk3 ай бұрын

    thank you sir for this video , i have one question I have a question concerning abaqus, I have modeled a hollow sphere in abaqus, and I have applied a radial displacement in the inner surface, but when I run the simulation, I get the following error 1 nodes have dof on which velocity/displacement/acceleration/base motion etc.constraintq are specified simultaneously.the nodes have been identified in node set ErrNodeBCRedundandDof

  • @AliSiddiqui-hd7he
    @AliSiddiqui-hd7he3 ай бұрын

    Music ruined the whole video!!!!!

  • @somdebsar7378
    @somdebsar737813 күн бұрын

    I like her voice, and that makes everything, her voice is so seducing!!!

  • @kar-dt1hk
    @kar-dt1hk3 ай бұрын

    hello sir ,how i can connect matlab with gnuplot

  • @tuminonyana
    @tuminonyana3 ай бұрын

    For two-dimensional models, if a non-unity thickness is specified for two-dimensional solid elements and these elements are involved in an interaction such as contact, the same thickness should be specified for the out-of-plane thickness of the corresponding surface under *surface interaction.

  • @ameliam7732
    @ameliam77323 ай бұрын

    Hello, how do we solve if the error shows node set not defined

  • @mdmaseehuddin
    @mdmaseehuddin4 ай бұрын

    Can we install polaris fibrogenesis plugin the same way

  • @KaarthicKaundabalaraman
    @KaarthicKaundabalaraman4 ай бұрын

    How can you help me in getting the model meshed as per the reference model

  • @kinlee5491
    @kinlee54914 ай бұрын

    NICE!

  • @somdebsar7378
    @somdebsar73784 ай бұрын

    Your voice is very sweet

  • @user-qg3qy7yk5b
    @user-qg3qy7yk5b4 ай бұрын

    정말 감사드립니다

  • @user-pl2ws2bk6d
    @user-pl2ws2bk6d4 ай бұрын

    Why did you explain it like that? I wasted so much time because you confused me. For anyone attempting to replicate the simulation, please DO NOT follow the previous instructions. In the user subroutine interface, FIELD(1) should be set equal to the radius. Abaqus utilizes this value to evaluate the Young's modulus and Poisson's ratio based on the 3rd column, which represents the radius in this case, NOT THE YOUNG'S MODULUS! The current code is incorrect. The key thing to understand about USDFLD is that FIELD(1) corresponds to the Field 1 column in the definition of the material model. So, you should simply write FIELD(1)=r, and then Abaqus can identify the appropriate row in the tabular data. Hyper Lyceum, instead of helping me, you confused me. If you don't know something, don't upload videos claiming to be experts!

  • @hariomsaransingh3783
    @hariomsaransingh37835 ай бұрын

    For *tie pair (assembly_surf-2-assembly_surf-1), adjustment was specified but no node was adjusted more than the adjustment distance = 2.22000e-16.

  • @ettajayaram7167
    @ettajayaram71675 ай бұрын

    THIS KEYWORD IS NOT AVAILABLE IN Abaqus/Explicit Analysis will be terminated Analysis Input File Processor exited with an error. i am getting this error can you please help me

  • @ettajayaram7167
    @ettajayaram71675 ай бұрын

    THIS KEYWORD IS NOT AVAILABLE IN Abaqus/Explicit Analysis will be terminated Analysis Input File Processor exited with an error. can you please help me

  • @palashdas823
    @palashdas8235 ай бұрын

    Can you provide VUSDFLD instead of USDFLD, for the same problem it simulate in dynamic analysis ?

  • @BalamuruganS-zy3sc
    @BalamuruganS-zy3sc5 ай бұрын

    How to pick a point in the middle of the flat sided bone surface. In assembly, Instances - Not able to pick that point for placing the implant

  • @yaserjahan7555
    @yaserjahan75555 ай бұрын

    Wow❤❤

  • @civilengineeringknowledgeb2955
    @civilengineeringknowledgeb29555 ай бұрын

    For two-dimensional models, if a non-unity thickness is specified for two-dimensional solid elements and these elements are involved in an interaction such as contact, the same thickness should be specified for the out-of-plane thickness of the corresponding surface under *surface interaction.........................can you explain about this problem please

  • @amrmasoud5580
    @amrmasoud55805 ай бұрын

    Hi Please tell me how to define the bond slippage between line truss or beam elements and solid element in abaqus??

  • @easyhack5859
    @easyhack58595 ай бұрын

    I have a question. Can i add the energy equation containing T and alphaTh in the interfoam solver ?

  • @user-oo4iy2zd2j
    @user-oo4iy2zd2j5 ай бұрын

    thank you sir for this video, it is very interesting

  • @hussainwaris2838
    @hussainwaris28386 ай бұрын

    Thank you so much for this amazing video Stay blessed❤

  • @hensem5442
    @hensem54426 ай бұрын

    Hey can i send you my model and you do the meshing part?

  • @jinbokchoi3755
    @jinbokchoi37556 ай бұрын

    I have a question, I think we need to define the FIELD(1) =radius instead of Young's modulus because we defined the Field 1 in material behaviors. Don't you think like that?

  • @arifhussain5610
    @arifhussain56106 ай бұрын

    Thank you for such detailed explanation

  • @subhasis9923
    @subhasis99236 ай бұрын

    Sir in the last option T is not coming

  • @Anatomy.doctor
    @Anatomy.doctor6 ай бұрын

    Good presentation.. Please suggests the links where I can get all material vulues for femur bone...

  • @hyperlyceum60
    @hyperlyceum606 ай бұрын

    Hi, You find download the model from here: hyperlyceum.com/product/heterogynous-bone-how-to-apply-material-properties-using-mimics/ Inside the INP file you can find the material properties. Also if you have any reuquests or questions, please contact our tutor: [email protected]

  • @Anatomy.doctor
    @Anatomy.doctor6 ай бұрын

    ❤❤

  • @johncarter40101
    @johncarter401017 ай бұрын

    I have a question: I WANT TO CHANGE DENSITY AS A FUNCTION OF TEMPERATURE VALUE AT EACH INCREMENT, HOW TO CALL IT IN USDFLD SUBROUTINE?? PLEASE HELP. I mean , how to update density variable as function of TEMP solution value?

  • @hyperlyceum60
    @hyperlyceum607 ай бұрын

    Hi, You don't need USDFLD subroutine for this task. You just need to activate temperature dependent box in density panel and insert your temperature dependent density in the table. You can use this link: 130.149.89.49:2080/v6.11/books/usi/default.htm?startat=pt03ch12s08s01.html Follow the 3rd step.

  • @martinmoran4919
    @martinmoran49197 ай бұрын

    Thank you for sharing. So compression would be at the bottom and traction at the top parts, right? I mean with that moment sign arrow.

  • @hyperlyceum60
    @hyperlyceum607 ай бұрын

    The tutor who made this video is not available right now. but I believe it is correct.

  • @CJFHXY
    @CJFHXY7 ай бұрын

    nice video~

  • @hyperlyceum60
    @hyperlyceum607 ай бұрын

    Thank you

  • @abhimuliya7456
    @abhimuliya74567 ай бұрын

    "Abaqus/CAE kernel exited with an error, how to resolve", this message shows after installation when I open Abaqus 2023 first time in my Windows 11 Laptop

  • @hyperlyceum60
    @hyperlyceum607 ай бұрын

    I m not quite sure the reason. It might be related to licensing issue. Please let us know how did you solve it.

  • @abbastaheri470
    @abbastaheri4708 ай бұрын

    I really appreciate your help

  • @hyperlyceum60
    @hyperlyceum607 ай бұрын

    Glad to hear it

  • @cn7030
    @cn70308 ай бұрын

    Can you give me enlightment, what is the list within in system? I'm just wondering, because, my datToFoam can't read my *.dat