Structural Engineer Calcs
Structural Engineer Calcs
Welcome to Structural Engineer Calcs: Your Trusted Partner in Structural Solutions.
🔹 Who We Are:
25+ years of UK based experience in delivering precise structural calculations and design using cutting-edge software.
🔹 Our Expertise:
From home extensions to commercial projects, we offer tailored, cost-effective designs.
🔹 Why Choose Us:
✅ 25+ Years Experience
✅ Advanced Software
✅ Nationwide Service
✅ Cost-Effective
🔹 Special Offer:
Planning a home renovation or new build? Our expert engineers are here to help, serving London, Birmingham, Manchester, and beyond.
📞 Call Us: +44 7359 267907
🌐 Website: structuralengineercalcs.com/
🔹 Educational Outreach:
Subscribe for weekly tutorials to elevate your structural engineering skills.
🔹 Disclaimer:
None of what we teach in our videos should be taken as 'advice,' and you should always have your designs reviewed by a competent, experienced, registered, or chartered engineer.
Пікірлер
Thanks for the video, but to really teach the design of a metallic beam, you must add a box explaining what each letter stands for. Because, if you are explaining the design of a beam to a person that already know what forces,and how this forces affect the beam, then the video is of not much use. Beginning with the notion that algebraic expression can be solved by any student of last high school year. Thanks again
Why did you stop posting, your videos are really helpful and beneficial
nice channel
Q=ka*q*H
I ve a sere load of 4000kg over a span of 2 meters. What capacity of MS I beam do I need. Sere load concentrated over 250x250 mm area from wall.
I do hope that you'll have a separate channel discussing more on manual calculation of civil works (i.e earthwork, road , drainage, water reticulation, sewer reticulation, etc). Btw, really informative channel. Love it.
great video sir. Appreciate your knowledge sharing.
Where does 384 come from?
It's well explained and all the information is correct but omits some important information about group capacity. As it's poor practice to have single bolt connections in multi bolt connections for simply supported beams, beam flexure causes rotation of bolt holes which increases the load on the bolts. Although I don't believe this is directly covered by EN 1993-1 other literature does cover this such as The Steel Designer Manual 25.4.2 and SN017 where bolt shear capacity (or additional force applied) is reduced based based on bolt group geometry. It my be helpful to add this or create a separate video if you have not already. I ran some FE models and the effect is real, think it was something like 27% of vertical shear for a typical beam which tied in with SN017
Very useful! worth noting the 0.6 shear factor can be different, in Eurocodes it can be 0.5 also!
Isn't the steel characteristic strength fck factor of safety already accounted for from the stress block that gives rise to 0.87 in the steel formula for reinforcement area required?
Good day Mr Structural Engineer Calc. I have this problem that i am solving and i can not find any relevant to the question, Please assist me with any source of relevant material that i can use to get it solved or any method or steps that i can follow to get to the correct possible design. Provide an optimal design of a 16 m long concrete pile that is to be driven into 12 m of loose sand that was underlain by very stiff clay. The geotechnical parameters of the sand and stiff clay are respectively as shown in Figure Q2 below: Sand: ∅’= 26°; Unit weight γ = 19 kN/m3 Stiff clay: cu = 80 kN/m2; Unit weight γ = 18 kN/m3 The pile is expected to undertake the following characteristic loads: DL = 35 00 kN LL = 25 00 kN Also, Fcu = 40 MPa and Fy = 450MPa Additionally, maximum pile length allowable = 20 m (meaning the stiff clay can extend to 20 m depth). The idea behind this exercise is to provide an optimum design.
Nice Video
Where is the tensile area actually referring to? If I have a longer thread engagement, would it change the tensile area?
What if it's a solar system on the ground of a country side
What standard reference does this use? Do you use ASCE?
help ful video
How can a roof with zero slope have a windward and leeward value? With a flat roof shouldnt they be equal?
Thank you for the video
Your videos are superb are you vudeos relaxed to AISC codes?
Do we really need all these numbers. Won’t it be obvious if the bolts and plates are too big or too small.
Clear and good. Please do one on the internal pressure
Check for tension and compression?
thank you
Nice explanation. In the old AISC allowance stress design, you could just look up the tension or shear allowables for any size bolt. But this is a good refresher as to how those values are derived. 👍
Thank you very much, very infornative explanation
thankyou
Very informative video
Would you please design the same portal frame with the same dimensions using the eurocode 3? 🙏🏾🙏🏾🙏🏾🙏🏾
what is the code using this example?
Thank you Sir for this easy approach. I have my actual stress as 157N/mm^2, is the column suitable?
this video is very nice please which software are you using to do this video?
How can we get surcharge load
Perfect, go ahead by applying the load for multistory buildings
The problem arises when structural engineers require geotech engineers to perform these checks. Utter chaos!
i couldnt see the selfweight of the beam is add into gk. Unless it assumely included in the gk provided. Btw , thanks for the clear explanation on the load distribution.
what do u mean by gk
🙏🙏🙏
Kindly need the references for the equations above
Thanks. Good Example.
How did you come up with "A" 4973 ? It is not clear where this total area is derived from. As ii is the total area of member in solid beams.
An FEA analysis on this problem results in maximum 285 MPA (von Mises Stress) and maximum deflection of 1.8 mm.
This is applicable for piles dia less than 600 mm. What about large piles with dia more than 600 mm?
Is it okay to consider (2 or more as leading variable) both floor load and wind load as leading load in equation 6.10? or in Equation 6.10 the leading variable should only be one?
The real trick is knowing what wind loading to apply.
also to calculate shaft surface area y u took pile length 5.5m
y u dont divide the shaft area by 4 as you done in pile surface area
good load bearing capacity calculation of truss # but the load bearing capacity also greatly depends on the gauge , thickness , of the truss pipes #🇵🇰
Q.1) A rectangular beam supported on 300 mm wall having clear span 6m. Live load is 12 KN/m. Use M20 and Fe 415 materials. Width of beam is fixed at 300mm. Design the beam. What’s the effective depth on this one I am trying to calculate the effective span which is the c/c distance between supports using IS code
Can you make a video on how to design for the internal members?
nice video i wanna seee more of these type videos