𝗘𝗹𝗲𝗰𝘁𝗿𝗶𝗰𝗮𝗹 𝗧𝗲𝗰𝗵𝗻𝗼𝗹𝗼𝗴𝗶𝗲𝘀 is based on an embedded system design that is a set of hardware and software designed to carry out a predefined task. Autonomous, often real-time, and a set of optimizations at both hardware & software levels.
𝗛𝗲𝗿𝗲 𝗶𝘀 𝗸𝗲𝘆 𝗳𝗶𝗲𝗹𝗱 𝘄𝗲 𝗰𝗼𝘃𝗲𝗿.
💡 Arduino Firmware development
💡 Project Designing
💡 PCB Designing
💡 Altium Designer
💡 Atmel Studio Programing
💡 PIC Controller
💡 Proteus Professional
💡 Automation
💡 Electronic
💡 Solution Provider
📝 Problem Solving
Mail Us: 👉 [email protected]
WhatsApp 👉 +923463183896
Website: 👉 www.prototypeguru.com/home/
Instagram 👉 instagram.com/electromentor/
Greetings From Pakistan ❤️
Пікірлер
Bro ess ma MCB nhi lagta. Ha
Nice Video, very helpful!
I think contactor faulty
Actually the AHD Power supply has separete power outputs to each cam, the wire of the DVR power supply should have different color from black the same color used to video imput from cam into dvr
kzread.info/dash/bejne/qoOeu9umlN3bo6Q.html
thank you so much
Pleasure
Great information thanks 👍
Thanks 🎉❤
WRONG. 99 out of 100 NVR's uses VLAN's for cameras ports. That been said, the diagram shows that the notebook is connected to the NVR VLAN port and by that, it will have access to the cameras directly but will not have access to the local network or internet. The notebook should be connected to the router.
sorry in 2-way switch no on/off tag given
First time correct information on youtube thanks for sharing
আপনার কানেকশন ভুল
Sepertinya ada yg salah
Router>Switch>NVR is the correct way not Router>NVR>Switch.
T
Do we need CCTV DC power to power the cameras again, thought the LAN cable had already taken care of that one...
Bravooo
Thanks 🙂
Please from this practical. Does it mean that the ethernet stands as a source of power supplies to the four cameras since it's in wireless form?
Ver nice video
Useful, how to retrieve the video records from NVR to system? Is it through a web browser or any external apps that we need to use? Pls advise
Good
Amazing
What is the perpes of push button switch
Bhai ye to godan wiring h tunnel m to 2 way swich k ek sire p neutral or niche bake p phase bich bale commen p led bulb lagta h
kzread.info/dash/bejne/nGuCrNqDc7DLhNY.htmlsi=C_Y0T9t8oB8q2rqU
WTH you need that switch for? You have it in NVR. It's only useful when you have bigger network than that or/and you want to use it in different room or smtn. Otherwise it's useless.
👍👍👍👍
what what is used, straight through or cross?
the poe switch, needs to be linked to the internet router too?
i like your metode..but, what BYR same with RST?thanks..
Sir which application did you used how can I make this type of videos Please answer me ❤
Bhai, is na too ap CT lgaye hen , na ap ny Amp meters layer hen aor na ap ny iss me ACB ka istemal kia ha. Aor MCCB ki jaga ap sirf BCB ka use kia ha. Auto control switch bhi nahi ha. 😮😮😮😮 Ap k kam ka toooooo ALLAH hi hafiz ha.
Sir ❤, please make its control wiring
Which site or app do you use to do you videos
Doodly animation software
😑
Hi, can you send to me diagram
Excellent job 🎉 helpful very easy
Which ones are the coil?
A1 and A2 are coil terminals
In a two wire tank float valve, is it best to run it with the neutral? It would interrupt the circuit of the remote cantactor/relay without having 120v in the tank. I can not understand the video to see if this is the case.
Moi est je ve compren
Good video
Pleasure it was helpful for you.
And your control wiring is wrong for the overload
The wiring at the out going of the delta contactor is wrong
Can i just use NVR without POE with each wire for camera conected to nvr ?
I have a 220 - 2 wire submersible well pump that fills a water tank. I have the Schneider contractor and a 3 wire float switch. I want the well to run when the tank is less than full. Can you confirm the video is for my setup?
Galad he sir
Why magnetic contactor are 24 DC volt???
Consider installing a double pole circuit breaker after the RCD for each phase. Then you can isolate one room and still have power to the other rooms if you need to work on the wiring in that room. But it is safer to switch off everything. The real advantage comes in when there is a fault in the one room it will only trip power to that room and not the whole house.
Very nice thank you
Nibyiza