OMICRONenergy

OMICRONenergy

We are an international company founded in 1984 in Vorarlberg, Austria. With more than 1,250 employees from about 70 nations worldwide, we operate from 24 locations across the globe.

Our focus lies in developing innovative technologies to make electric power systems safe and reliable, meeting current and future challenges of the energy sector. We specialize in electrical testing for medium- and high-voltage equipment, protection testing, digital substation testing solutions, and cybersecurity solutions. Customers in more than 170 countries rely on our solutions and trust in their accuracy, speed, and quality.

Пікірлер

  • @rustanvillanueva223
    @rustanvillanueva22321 күн бұрын

    Great upgrades!

  • @omicronenergy
    @omicronenergy5 күн бұрын

    Thanks! :)

  • @NabijonHazratqulov-rb2uf
    @NabijonHazratqulov-rb2ufАй бұрын

    Hi . Thanks a lot.

  • @NimeveasKM
    @NimeveasKMАй бұрын

    Alguien sabe por norma cuánto es el tiempo máximo que pueden estar desincronizados los polos del interruptor?

  • @trueway697
    @trueway697Ай бұрын

    Hello sir Can i use this software in my apple MacBook laptop

  • @RadioNostalgia
    @RadioNostalgia2 ай бұрын

    Ahhh.... Che ricordi da ragazzino quindicenne !! La "fucilata"' era proprio così ! Lo so, non avrei potuto entrare in sottostazione, ma Papà era uno dei più noti e richiesti responsabili del collaudo di trasformatori e comunque eravamo tutti per forza al sicuro in camera di manovra. Una vita in mezzo alle centrali di tutto il mondo. Oggi avrebbe avuto 99 anni 😢

  • @juliefeng4355
    @juliefeng43552 ай бұрын

    Awesome podcast,I would like to introduce H2SCAN hydrogen DGA online monitor to you. please feel free to contact.

  • @fabiochiesa4422
    @fabiochiesa44222 ай бұрын

    Ok now wake up 😂

  • @tyanmutter1437
    @tyanmutter14373 ай бұрын

    Thankyou for your vids, very interesting. For now i study Master Electrical about Maintenance of Power Apparatus, and talk about PD. Very interesting for continue my final project about PD 👍. I hope one day, I can join your company to work maintenance👍

  • @hermifelder93
    @hermifelder933 ай бұрын

    Wie ist der Nettopreis für das Messgerät ? mfg

  • @omicronenergy
    @omicronenergy2 ай бұрын

    Hi @hermifelder93, danke für die Anfrage. Bei Interesse zum Produkt, füllen Sie gerne unser Kontaktformular auf der Webseite aus: www.omicronenergy.com/de/kontakt/email/?products=COMPANO%20100&request_type=1&cHash=37d7f94e6cfe7e15a4ececad54a2fdc2. Es meldet sich dann eine/r unserer Sales-Kolleg:innen bei Ihnen für weitere Details. Vielen Dank und liebe Grüße, OMICRON team

  • @user-ly9pj1bh2l
    @user-ly9pj1bh2l3 ай бұрын

    Quero aprender

  • @omicronenergy
    @omicronenergy3 ай бұрын

    Estimado @user-ly9pj1bh2l, gracias por su comentario y su interés. Puede encontrar más información aquí: www.omicronenergy.com/es/aplicacion/pruebas-fuera-de-linea/pruebas-de-subestaciones-aisladas-en-aire/ Saludos cordiales, su equipo OMICRON

  • @filchaneco506
    @filchaneco5063 ай бұрын

    where to download software

  • @omicronenergy
    @omicronenergy3 ай бұрын

    Hi @filchaneco506, thank you for your comment and interest. You can download the PTM software here: my.omicronenergy.com/software/primary-test-managertm-ptm/ after log in. Best regards, your OMICRON team

  • @XEinstein
    @XEinstein3 ай бұрын

    Ha! This is perfect! My work and hobby (adventure racing) combined. Where can I apply for a job at Omicron?

  • @omicronenergy
    @omicronenergy3 ай бұрын

    @XEinstein, sound's super nice - a match for you :) You can have a look at our open vacancies here: www.omicron.jobs/en/jobs-opportunities/jobs/ Best regards, your OMICRON team

  • @youssofasiry7233
    @youssofasiry72333 ай бұрын

    Thanks for clear explanation and all details. I have question regarding this subject can I depend on excitation current result during TTR test ? If we have result zero current in one phase What is the possible reason? Also we did the winding resistance test and all phase give us reading within the limit.

  • @omicronenergy
    @omicronenergy3 ай бұрын

    Dear @youssofasiry7233, thank you for your reply and the interest. Yes, you can depend on the excitation current result during the Transformer Turns Ratio (TTR) test. The excitation current is voltage-dependent and non-linear, and it can provide valuable information about the transformer's condition. If you are measuring zero current in one phase, it could indicate a turn-to-turn short circuit fault in that phase. The excitation current results will rise significantly on the affected phase if such a fault is present. On the other hand, it could also be a problem with the measurement device or the connection. If you have some questionable results, please send an e-mail to [email protected] who are happy to help you with your inquiry. As for the winding resistance test, it is done to verify internal connections and to detect any open or poor connections. If all phases are giving readings within the limit, it suggests that the transformer's internal connections are in good condition. However, keep in mind that this test is very sensitive to temperature, and results must be corrected to standard temperature. Best regards, your OMICRON team

  • @dirkalbrecht4796
    @dirkalbrecht47963 ай бұрын

    Dreamteam Thomas und Karsten 😂!

  • @30mAkills
    @30mAkills4 ай бұрын

    Useful demo.

  • @omicronenergy
    @omicronenergy5 күн бұрын

    Glad it was helpful! :)

  • @juancarloshurtado
    @juancarloshurtado4 ай бұрын

    Excelente OMICRON gracias

  • @ameviademnyadenu8336
    @ameviademnyadenu83364 ай бұрын

    Merci pour cette prise en main, nous attendons les autres démo à venir

  • @abrahanvelasquez8860
    @abrahanvelasquez88604 ай бұрын

    buenos dias que medimos cuando hacemos un barrido en tension?

  • @omicronenergy
    @omicronenergy3 ай бұрын

    Estimado @abrahanvelasquez8860, gracias por su interés y comentario. Con FRANEO 800 no es posible realizar un barrido de tensión. Por favor, especifique su pregunta o contacte directamente con nuestro equipo de soporte técnico, estarán encantados de ayudarle: [email protected] Saludos cordiales, su equipo OMICRON

  • @juancarloshurtado
    @juancarloshurtado4 ай бұрын

    Excelente OMICRON gracias

  • @juancarloshurtado
    @juancarloshurtado4 ай бұрын

    Excelente OMICRON !!!

  • @user-bw3wf8wb4g
    @user-bw3wf8wb4g4 ай бұрын

    Quelle sont les causes d'échauffement les bobines de déclenchement et enclenchement Durant les testes de disjoncteur

  • @omicronenergy
    @omicronenergy3 ай бұрын

    Chère @user-bw3wf8wb4g, nous vous remercions de votre intérêt et de votre commentaire. Lors des essais de disjoncteurs, la surchauffe des bobines de déclenchement et de commutation peut être provoquée par des courants de circulation élevés. Ces courants peuvent générer une chaleur excessive, entraînant des dommages importants. Il peut également arriver que l'alimentation de la bobine soit interrompue et qu'elle continue à être alimentée même après le déclenchement du disjoncteur. Cette situation devrait normalement être évitée grâce aux contacts auxiliaires. Si vous avez besoin de plus d'informations, veuillez consulter le site : omicronenergy.com/cibano500 Meilleures salutations, votre équipe OMICRON

  • @MohsinRaza-gz7dz
    @MohsinRaza-gz7dz4 ай бұрын

    What is the minimum value of offline PD ?

  • @omicronenergy
    @omicronenergy3 ай бұрын

    Dear @MohsinRaza-gz7dz, thanks for your comment and for your interest in this video. For offline PD testing, if there are no PD present, the lowest measurable value is the general noise from the surrounding and the source at test voltage level. A blocking impedance helps to reduce the noise level from the source to test most sensitive. If you need more detailed information, please contact our technical support team: [email protected] Best regards, your OMICRON team

  • @josiahufono
    @josiahufono4 ай бұрын

    For a digital relay with no DC source available, wouldn't it be okay to use the V-Out to power it?

  • @omicronenergy
    @omicronenergy3 ай бұрын

    Dear @josiahufono, Thank you for your comment and your interest in this video. Yes, the COMPANO 100 has its own AUX-DC mode, which allows a relay without its own power supply unit to be supplied with DC via the V-Out. Best regards, your OMICRON team

  • @manishmaurya8727
    @manishmaurya87274 ай бұрын

    First view

  • @manishmaurya8727
    @manishmaurya87274 ай бұрын

    First view

  • @AsanMasraf
    @AsanMasraf4 ай бұрын

    in the min 3:03 shows something look like a transformer, I haven't saw anything similar 11KV to 400KV to this can you give info about it

  • @omicronenergy
    @omicronenergy4 ай бұрын

    Dear @AsanMasraf, thank you for your comment and interest in this video. This transformer is with one of our customers in Austria. The transformer is a 300 MVA transformer with horizontal 220 kV and 110 kV bushings. The UHF PD measurements were made with the UHF 800 using a UHF drain valve sensor. If you require further information or have any questions, please contact our technical support team: [email protected] Best regards, your OMICRON team

  • @AsanMasraf
    @AsanMasraf4 ай бұрын

    it can work with ASPEN or PSSE Softwares?

  • @omicronenergy
    @omicronenergy4 ай бұрын

    Dear AsanMasraf, Thank you for your question. The CMC 356 can be controlled via OMICRON software or via programming interface. It cannot be directly controlled via ASPEN or PSSE software. Therefore, we are currently planning on adding a feature in our RelaySimTest control software that will offer enhanced compatibility. In case you wish to know more about this please contact our technical support team ([email protected]) for more detailed information. Best regards, your OMICRON team

  • @ericbecerra7962
    @ericbecerra79625 ай бұрын

    Este modulo sirve para probar reconectadores?

  • @omicronenergy
    @omicronenergy5 ай бұрын

    Estimado, gracias por su interés y pregunta. Sugerimos probar los reconectadores con nuestro ARCO 400, pero por supuesto puede probarlos con un CMC y un secuenciador de estado. Puede encontrar más información aquí: www.omicronenergy.com/en/products/arco-400/ Saludos cordiales, su equipo OMICRON

  • @heldemarcio
    @heldemarcio6 ай бұрын

    Excelente vídeo.

  • @AsanMasraf
    @AsanMasraf6 ай бұрын

    what type of MICRON used for this type of test?

  • @omicronenergy
    @omicronenergy6 ай бұрын

    Hi @AsanMasraf, thank you for your comment and interest! In this video we used our COMPANO 100 for testing. You can find more information about it here: omicronenergy.com/compano100 Best regards, your OMICRON team

  • @SeshChannel
    @SeshChannel6 ай бұрын

    Profesjonalnie omówione

  • @JuanLopez-gw1se
    @JuanLopez-gw1se6 ай бұрын

    Que tal me pudieron decir cuál es la fórmula para cálculo ipol para un 587-1 porfavor

  • @omicronenergy
    @omicronenergy6 ай бұрын

    Estimado @JuanLopez-gw1se, gracias por su comentario e interés. En general, esta información se encuentra en el manual de cada relé. Si echamos un vistazo al manual del SEL-587-0, -1 (Código de fecha 20151105) podemos encontrar lo siguiente: 'El IRT1 se genera sumando las magnitudes de las corrientes de los bobinados en una simple suma escalar y dividiendo por dos.' O en palabras del TestObject: (|Ip|+|Is|) / K1 & K1 = 2 Por cierto, para la SEL587 disponemos de plantillas de prueba prediseñadas, en las que esta configuración ya está establecida por defecto, en nuestra Biblioteca de Pruebas de Protección (PTL): my.omicronenergy.com/software/ptl/library/ Gracias y saludos cordiales, su equipo OMICRON

  • @Jakcybtravis
    @Jakcybtravis6 ай бұрын

    Co to jest ten RETRIP?

  • @omicronenergy
    @omicronenergy6 ай бұрын

    Drogi @Jakcybtravis, dziękuję za komentarz i zainteresowanie. ReTrip jest częścią funkcji awarii wyłącznika. Przy pierwszym wyzwoleniu (I>) uruchamiany jest licznik czasu i monitorowany jest przepływ prądu. W przypadku, gdy prąd nadal płynie i upłynie określony czas (w tym przykładzie ReTrip = 150 ms), wyzwalane jest drugie polecenie wyzwolenia, sygnał ten może być użyty dla dodatkowej cewki wyzwalającej dla tego samego wyłącznika. Jeśli prąd nadal płynie i upłynie dłuższy czas (w tym przykładzie LRW = 250 ms), wyzwolone zostanie polecenie awarii wyłącznika i zadziała zabezpieczenie wyższego poziomu. Dziękujemy i pozdrawiamy, zespół OMICRON

  • @Jakcybtravis
    @Jakcybtravis6 ай бұрын

    @@omicronenergy Bardzo dziękuję za dokładną odpowiedź. Czy zrobicie więcej filmów z wytłumaczeniem zasady działania automatyki zabezpieczeniowej w elektroenergetyce? Pozdrawiam serdecznie.

  • @omicronenergy
    @omicronenergy6 ай бұрын

    Cześć @Jakcybtravis, dziękujemy za Twój wkład i zainteresowanie. Bardzo doceniamy Twoją opinię. Nasz zespół wideo stale pracuje nad nowymi treściami dla Ciebie, więc wracaj na nasz kanał. W międzyczasie możesz rzucić okiem na tę playlistę: kzread.info/head/PLzmbZeI1bhu8ueuD38nveqD_U62E6sUx9&si=W6QP1n9Yo4xgpIVC lub odwiedzić naszą stronę internetową, aby uzyskać więcej informacji na temat testowania ochrony: www.omicronenergy.com/pl/testowanie-zabezpieczen/ Z wyrazami szacunku, zespół OMICRON

  • @travellerquotes9076
    @travellerquotes90766 ай бұрын

    Hi Thanks Your explanation very good. But I need Clarifications on "Configure test set". Can we able to simulate this one without Testing Kit and Relay ?! or Have to connect the testing kit for this Step Configure test set? Help me on this

  • @omicronenergy
    @omicronenergy6 ай бұрын

    Hi @travellerquotes9076, thank you for your comment and interest. You can predefine everything with an offline device in your office, i.e. define which CMC outputs should go to which relay inputs. Then, onsite, you only have to connect the CMC with your PC and choose it from the available device list. Afterwards, you can wire up the CMC, do a wiring check and perform your tests. Thank you and best regards, your OMICRON team

  • @travellerquotes9076
    @travellerquotes90766 ай бұрын

    @@omicronenergy Thanks you for Your Response So You are saying that we can configure everything Offline But before Run the test we have to connect with Kit right.

  • @omicronenergy
    @omicronenergy6 ай бұрын

    @travellerquotes9076 yes, you are right 😊

  • @Vipel.C
    @Vipel.C6 ай бұрын

    How much is it

  • @omicronenergy
    @omicronenergy6 ай бұрын

    Thank you for your interest and comment. To answer your question, please get in touch with us directly. You can find your local contact person here: www.omicronenergy.com/en/contact/addresses/ Thank you and best regards, your OMICRON team

  • @urbainzokouendet8739
    @urbainzokouendet87396 ай бұрын

    au poste de technicien d'analyse et diagnostic des machines électriques.

  • @urbainzokouendet8739
    @urbainzokouendet87396 ай бұрын

    je suis au Gabon je cherche le travail j'ai une licence électromécanique.

  • @omicronenergy
    @omicronenergy6 ай бұрын

    Nous vous remercions de votre commentaire et de votre intérêt. Veuillez visiter notre plateforme d'emploi pour consulter les opportunités que nous avons en ce moment : www.omicron.jobs/en/jobs-opportunities/jobs/ Merci et meilleures salutations, votre équipe OMICRON

  • @mateusbatistapinto6764
    @mateusbatistapinto67646 ай бұрын

    Qual o valor de uma mala dessas?

  • @omicronenergy
    @omicronenergy6 ай бұрын

    Obrigado pelo seu interesse e comentário. Para responder à sua pergunta, contacte-nos diretamente. Pode encontrar a sua pessoa de contacto local aqui: www.omicronenergy.com/en/contact/addresses/ Obrigado e cumprimentos, A sua equipa OMICRON

  • @landrhykopp9836
    @landrhykopp98367 ай бұрын

    COOL

  • @user-yh1me9rl4p
    @user-yh1me9rl4p7 ай бұрын

    I love Omicron

  • @Br_1985
    @Br_19857 ай бұрын

    Was kostet das gute Stück?

  • @omicronenergy
    @omicronenergy6 ай бұрын

    Vielen Dank für Ihr Interesse und das Kommentar. Um die Frage zu klären, wenden Sie sich bitte direkt an uns. Ihren lokalen Ansprechparnter finden Sie hier auf unserer Webseite: www.omicronenergy.com/de/kontakt/adressen/ Vielen Dank. Ihr OMICRON-Team

  • @Showmeagrizzlybear
    @Showmeagrizzlybear7 ай бұрын

    Hold my beer and watch me test this substation.

  • @rachidoumha216
    @rachidoumha2167 ай бұрын

    Bon explication ✅ Merci

  • @alexandrerodrigues81
    @alexandrerodrigues818 ай бұрын

    Muito bom. Estou estudando e. Dezembro iniciamos o plano de manutenção de 6 anos, aqui na SE e vamos usar o CPC100 nos testes.

  • @carlosorlandocarlosorlando6743
    @carlosorlandocarlosorlando67438 ай бұрын

    Bom dia a que é u Carlos

  • @carlosorlandocarlosorlando6743
    @carlosorlandocarlosorlando67438 ай бұрын

    Bom dia aqui e u Carlos

  • @akramrza4727
    @akramrza47278 ай бұрын

    How can buy cmc356?

  • @omicronenergy
    @omicronenergy8 ай бұрын

    Dear @akramrza4727, thank you for your interest in our CMC 356. Please fill out our contact form and an OMICRON sales manager will get in touch with you for more details: www.omicronenergy.com/en/contact/email/ Thank you and best regards, your OMICRON team

  • @user-mq2wg3mf1x
    @user-mq2wg3mf1x8 ай бұрын

    Как обстоят дела с проводимостью 3 кА через "крокодилы"?

  • @omicronenergy
    @omicronenergy8 ай бұрын

    Уважаемый @user-mq2wg3mf1x, Благодарим Вас за комментарий и проявленный интерес. Для выхода 3 кА Вам потребуется 3 CPC и 3 CP CB2 (CPC Current Booster). Синхронизировав их, можно получить ток не более 6 кА. 6 кА. Однако зажимы "крокодил" в видеоролике были подключены к входу CPC 100 10A, который используется для измерения тока на вторичной обмотке ТТ. Спасибо и наилучшие пожелания, ваша команда OMICRON

  • @thomasregnier9739
    @thomasregnier97399 ай бұрын

    très bon matos Omicron ! Meilleurs que leurs concurrents en tout cas :)

  • @omicronenergy
    @omicronenergy5 күн бұрын

    Merci :)

  • @raminmollahajloo4059
    @raminmollahajloo40599 ай бұрын

    Thank you for video It’s very helpful 🙏🏼🙏🏼🙏🏼