Why did we replace this not so very old consumer unit?

Тәжірибелік нұсқаулар және стиль

Let’s smash the plumbers
www.ticketfairy.com/event/soc...

Пікірлер: 48

  • @tomstovell7425
    @tomstovell74252 ай бұрын

    Neat install and also the fact you taken into account the other equipment around it so aesthetically pleasing!! Enjoy your vids Chris. Keep them coming.

  • @johnwaby4321
    @johnwaby43212 ай бұрын

    Get some reducing pins on order for your van 👍👍👍 Great job with that swa cable into the board .

  • @shaun30-3-mg9zs
    @shaun30-3-mg9zs2 ай бұрын

    Nice work , neat and safe👍Have a good weekend,Chris & James

  • @Cjrelectrical

    @Cjrelectrical

    2 ай бұрын

    Cheers 👋

  • @supersparks9466
    @supersparks94662 ай бұрын

    Good job ,watching from Florida,it’s hot here too

  • @garethhodson3896
    @garethhodson38962 ай бұрын

    Really nice job 👍

  • @pm1104
    @pm11042 ай бұрын

    What a lovely neat wiring job…………apart from leaving all the mess on the floor ……..I though5 you always used to tidy up after…!😢

  • @ivankirola2707
    @ivankirola2707Ай бұрын

    3:17 wow I'm quite suprised to see ETi fuses in the UK.

  • @wizard3z868
    @wizard3z8682 ай бұрын

    I'm being cheeky but it seems from the otherside of the pond everytime you need to add or replace a device it's a consumer swap out lol 😆

  • @Cjrelectrical

    @Cjrelectrical

    2 ай бұрын

    Yeah seems that way but Jo always the case if you leave enough spare ways for the next guy.

  • @leeroberts1192
    @leeroberts11922 ай бұрын

    2:36 I'm not a spark with with the original board, it seems like many of the old connections have too much copper exposed

  • @craiggoddard488
    @craiggoddard4882 ай бұрын

    No SPD….. it was fitted 5 years ago.

  • @AAaa-wu3el

    @AAaa-wu3el

    2 ай бұрын

    No need for SPD.

  • @anthonybragg
    @anthonybragg2 ай бұрын

    I used to find the problem with the earth terminals only used to take up to 16mm and that was 15 years ago you would have thought that consumer unit manufacturers would have made one of the terminals to take 25mm considering this is now more the norm. The video stopped a bit abruptly at the end Chris.

  • @lewis94uk
    @lewis94uk2 ай бұрын

    Nice work, editquest are local to me in Luton

  • @Cjrelectrical

    @Cjrelectrical

    2 ай бұрын

    The whole electrical installs been a shower of shit.

  • @Mark-xr4zt
    @Mark-xr4zt2 ай бұрын

    Don’t even need to watch the video to answer the question. The simple answer is because it’s a Hager, so that’s the only reason ever needed to swap it out 😂

  • @danvictor3934
    @danvictor39342 ай бұрын

    Hi why not just replace Hager RCDs for Hager Rcbos and link the neutral bars together with a linking kit although i do not think hager have ever been called cheap before.

  • @Cjrelectrical

    @Cjrelectrical

    2 ай бұрын

    Just wanted to have a good reason to overcharge the client.

  • @user-ej8tt6lr2k
    @user-ej8tt6lr2k2 ай бұрын

    Work hard to find guys? honestly!

  • @Cjrelectrical

    @Cjrelectrical

    2 ай бұрын

    Huh

  • @ronnierobinson1502

    @ronnierobinson1502

    2 ай бұрын

    This one cost 55k

  • @user-ej8tt6lr2k

    @user-ej8tt6lr2k

    2 ай бұрын

    @@ronnierobinson1502 Next week had to rewire cos the cable bend radius is too much. Amazing the power of an "NIC Approved" sticker. Yeeeehaaaw

  • @nolanbrownwig5703
    @nolanbrownwig57032 ай бұрын

    Hager "its a cheap board really " 😳...

  • @Jay369

    @Jay369

    2 ай бұрын

    Cheap as in no RCBO's.

  • @TheShinnion
    @TheShinnion2 ай бұрын

    Jesus Christ the trolls out in force for this one, 😂

  • @DS1-1a
    @DS1-1a2 ай бұрын

    Lol, rips out a Hager and fits a FuseBox…

  • @heladas90

    @heladas90

    2 ай бұрын

    Because hager is poo poo, they are Billy big bollocks and don't actually care about installers

  • @tonywatson1412
    @tonywatson14122 ай бұрын

    Remember James....you cant use your phone while playing football 😂 / you say...cheap board..its a Hagar....! ! and your fitting Fusebox . .fair enough its rcbo ...never heard Hagar , called cheap

  • @Cjrelectrical

    @Cjrelectrical

    2 ай бұрын

    Split load A/C rcd with mcbs about £60

  • @tangoengineering
    @tangoengineering2 ай бұрын

    no banjo or banjo earth

  • @Cjrelectrical

    @Cjrelectrical

    2 ай бұрын

    Yep and earthed down at mains as it’s accessible

  • @tangoengineering

    @tangoengineering

    2 ай бұрын

    @@Cjrelectrical nice one

  • @Scoobydooo85
    @Scoobydooo852 ай бұрын

    Nice work, shame about the clean up!!!! 😂

  • @Cjrelectrical

    @Cjrelectrical

    2 ай бұрын

    Cleaning up is extra

  • @YoutubeHero666

    @YoutubeHero666

    2 ай бұрын

    standard electricians :)

  • @AAaa-wu3el
    @AAaa-wu3el2 ай бұрын

    Good box just thrown away for no reason.

  • @tf2368
    @tf23682 ай бұрын

    Doesn’t look like you tested it after install

  • @Horsecockbadger
    @Horsecockbadger2 ай бұрын

    What age are you and how long you been a electrician and if u had to do over would u still be a sparky??

  • @alvina69
    @alvina692 ай бұрын

    Could you not have recessed the board into the wall?

  • @debianowns4393

    @debianowns4393

    2 ай бұрын

    I want the answer to this too :) Not that I'm suggesting one should, I know nothing. I'm only here to learn!

  • @lewis94uk

    @lewis94uk

    2 ай бұрын

    Pointless

  • @hvaccuffingit6471

    @hvaccuffingit6471

    2 ай бұрын

    Do you have a link to the adhesive used on the grommet strip please? Thanks

  • @Cjrelectrical

    @Cjrelectrical

    2 ай бұрын

    @hvaccuffingit6471 Screwfix mitre mate 2 part glue

  • @Cjrelectrical

    @Cjrelectrical

    2 ай бұрын

    Absolutely yes. Few reasons we didn’t. It’s in a cupboard along with lots of other surface mounted tech. Lots of cables running behind in zone. Cables coming from top and bottom of board so would of had to cut out lots more plasterboard to juggle it in the gap. Solid brick wall behind so board would of still protruded 25-30mm. With this certain install adding circuits at a later date will be easier on surface. Anything else ….. it was Friday Oh yes fire grommets are really expensive and the budget didn’t allow for them.

  • @himyeshim6757
    @himyeshim67572 ай бұрын

    Earth leakage

  • @Cjrelectrical

    @Cjrelectrical

    2 ай бұрын

    Never had any problems I believe but yes rcbos will solve most earth leakage overloads as effectively we’ve now got 16 rcds instead of 2