Why Did The High Pressure Switch Kick Out | How To Reset A Defrost Board

Тәжірибелік нұсқаулар және стиль

Thanks for taking the time to watch our videos. If you have any questions let us know. We are here to help you to learn how to do HVAC service & things like software and apps that will help you run your HVAC business easier and more efficiently.
#HVACinstall #livestream #HVACservice
✅TWITTER - / mikepowlas
✅FACEBOOK - / mikepowlas
/ eastcoastyou. .
✅INSTAGRAM - / mikepowlas
✅PERISCOPE - www.periscope.tv/MikePowlas
✅ANCHOR - anchor.fm/michaelpowlas
🔴AFFILIATE LINKS
✅✅✅Buy My Book amzn.to/38Fx7DA✅✅✅
✅MERCH: bit.ly/2zOTRyO
✅WAVE VIDEO - bit.ly/2JYu8vW
✅AMAZON - www.amazon.com/shop/mikepowlas
✅WORKIZ - bit.ly/2SPSrvi
✅KIT - kit.co/MikePowlas
✅MORNINGFA·ME - morningfa.me/invite/mikepowlas
✅Tubebuddy - www.tubebuddy.com/powlasenter...
✅Tips To Grow Your Business - bit.ly/2wFMciB
✅Email List - bit.ly/2UlRQ59
✅Join Our Business Group - bit.ly/2wFMciB
✅Build A Website - bit.ly/2Vh0zpS
✅EBATES (Make Money) - bit.ly/2W7mvUJ
✅SQUAREUP Credit Card Processing - squ.re/31yAcjp
✅Streamyard The New Hangouts: bit.ly/2nR62Zr
✅Chime Spending Account: bit.ly/2oQFXtU
DISCLAIMER: This video and description contain affiliate links which means that if you click on one of the product links. I’ll receive a small commission. This helps supports the channel and allows us to continue to make videos like this. Thank you for your support!

Пікірлер: 69

  • @jri3tj485
    @jri3tj4853 жыл бұрын

    My fan motor seized without me noticing and cause the pressure to kick out, I replaced the motor and nothing happened. I saw how you reset the board and after the 5min. Delay everything is working fine. Thanks to you. 👏👏 Video was thorough and clear.

  • @jessevillagomez991
    @jessevillagomez9912 жыл бұрын

    Thank you, sir for explaining how to reset you saved me hundreds.

  • @FabianDohmes
    @FabianDohmes6 жыл бұрын

    Thank you! I found same random high-pressure fault on a Lennox 14HPX heatpump (occurred in heat mode) but coils and filter clean. Did power cycle/ reset via R wire - no more problems. Your thorough analysis gives me hope that it was random!

  • @Powlashvac

    @Powlashvac

    6 жыл бұрын

    It could have been just some trach in the line (cap tubes etc.) and it got removed and moved within the system.

  • @mattcollins7979
    @mattcollins79792 жыл бұрын

    This fixed my issue. Thanks!

  • @MrMultitool
    @MrMultitool7 жыл бұрын

    Good job, That looks like a very nice place. It does look like non condensables might be a problem though.

  • @lamansavin
    @lamansavin Жыл бұрын

    Thank you sir. It fixed my problem 🙏🙏🙏

  • @dannyhernandez7531
    @dannyhernandez75313 жыл бұрын

    Good Job!

  • @user-hu4hx6bm6m
    @user-hu4hx6bm6m4 жыл бұрын

    Great Man

  • @kinggenius6660
    @kinggenius66607 жыл бұрын

    fluctuating pressures non condensables / what is the temperature of the discharge line?

  • @edbarkley1904
    @edbarkley19042 жыл бұрын

    I reset my defrost board and the fan would not kick on and even after replacing the capacitor you can spin it and it still would. Not spend freely my. problem was fan motor. Thanks it was a great video you doing an outstanding job

  • @juanmartinez4215
    @juanmartinez42153 жыл бұрын

    Thanks Amigo

  • @jmanj9379
    @jmanj93794 жыл бұрын

    I just reset mine. Thk u. Dirty filter. My bad lol

  • @adamcraig1568
    @adamcraig15683 жыл бұрын

    Rumor has it that Powlas went for a 5 mile run right after this call😂

  • @dawoodbaig662
    @dawoodbaig6625 жыл бұрын

    Very nice and thoughtful diagnostic approach . Realy enjoyed watching . So what was the outcome ?Did you go back for same issue in that season?

  • @Powlashvac

    @Powlashvac

    5 жыл бұрын

    Went back like two weeks later to change the indoor motor. It sometimes not start. Thanks for watching

  • @search4truth616
    @search4truth6164 жыл бұрын

    The Lennox unit I just repaired at my home has a pressure switch with a reset button on it. The outdoor unit would not power on at all. I pushed the button on the High Pressure Switch and the unit started running again. I felt a distinct click when I pushed the button which I did not feel in subsequent pushing.

  • @snizshizzle

    @snizshizzle

    3 жыл бұрын

    What did this switch look like?

  • @mky9481
    @mky94816 жыл бұрын

    Need Mild Ambient Kit, running HP in warm weather causes high pressure sw tripped

  • @rachelsambrano5575
    @rachelsambrano55754 жыл бұрын

    Possibly AIr Handler ECM motor internal electronics tripping fan motor OFF and ON, power surge or after lightning strike possible. If this happens again, Will replace ECM X16 Motor, ------ with PCM motor, Century D1056 and fan relay.

  • @don4062
    @don40626 жыл бұрын

    Lennox had a recall on the blower fan controll the delay timer was replaced.it was intermittent.so if the fan timer failed to turn on the blower u get high pressure fault..

  • @niLfx

    @niLfx

    5 жыл бұрын

    Any details on how to identify if I have a recalled fan control?

  • @geecrawdad
    @geecrawdad5 жыл бұрын

    I just bought a low pressure switch for my heat pump Model CH5524VKA2.. When I measure ohms, it's open. I thought it is supposed to be closed or does it change after it's installed? Thanks.

  • @Powlashvac

    @Powlashvac

    5 жыл бұрын

    It opens on low psi and not being in the system it will have 0 psi. So it will close when it gets in the system as long as it is above the psi setting of the switch.

  • @geecrawdad

    @geecrawdad

    5 жыл бұрын

    @@Powlashvac Great, thank you.

  • @sh2697
    @sh2697 Жыл бұрын

    The church said the compressor burnt. Its only 5 years old. Are new compressor pre-filled with 410A?

  • @joeshearer1247
    @joeshearer12477 жыл бұрын

    Short the test pins to bypass the 5 mins works on most all of them also

  • @franchescaarzuaga8689

    @franchescaarzuaga8689

    5 жыл бұрын

    How can I do this?

  • @Alphadog343

    @Alphadog343

    3 жыл бұрын

    Joe, THANK YOU

  • @charlessutton4825
    @charlessutton48257 жыл бұрын

    what were you useing to test pressures with on your phone?

  • @Powlashvac

    @Powlashvac

    7 жыл бұрын

    This is the tool I use. Thanks for watching amzn.to/2jo0Up8

  • @flir67man84

    @flir67man84

    5 жыл бұрын

    Amazon says link doesnt exist can u repost the amazon link

  • @sh2697
    @sh2697 Жыл бұрын

    I tired to fix my church heat pump. I had power at the contactor and the contactor pulled in at a cooling call. It just clicked. I saw the control board flashing but I did not check for fault. I wonder if I should have reset it and waited for a time delay. Or, I thought maybe I should short the high pressure switch and the low pressure switch to eliminate a safety issue. Any suggestions?

  • @Powlashvac

    @Powlashvac

    Жыл бұрын

    Trace the 24 volts thru the safety controls to see if they are any open.

  • @sh2697

    @sh2697

    Жыл бұрын

    @@Powlashvac you mean the low pressure, high pressure switch, is there a condensation switch? (for heat pumps indoor), control board reset?

  • @derrickbeene89
    @derrickbeene893 жыл бұрын

    My keeps tripping high pressure lock out bypass the hight pressure switch still saying high pressure lock out even after error code reset

  • @TheEHSSC
    @TheEHSSC7 жыл бұрын

    Dirty filter, dirty blower, dirty evap coil...did you check airflow / CFM's?

  • @Powlashvac

    @Powlashvac

    7 жыл бұрын

    Due to I got the #'s on point I had to have good flow. But yes that was checked.

  • @kinggenius6660

    @kinggenius6660

    7 жыл бұрын

    Powlas Enterprises you were checking your numbers with the heat strips on.

  • @Powlashvac

    @Powlashvac

    7 жыл бұрын

    Doug c yes then without. still stayed well under 400

  • @kinggenius6660

    @kinggenius6660

    7 жыл бұрын

    Powlas Enterprises what is the correct way to do it? with the heat strips on? or heat strips off? heat strips on would simulate a high heat load inside?

  • @Powlashvac

    @Powlashvac

    7 жыл бұрын

    That would be without strips on. So that way you will get the true indoor temp and the right SA vs. RA.

  • @fishyouall
    @fishyouall3 жыл бұрын

    Great Video! I just figured out that my problem is high pressure switch . how do I reset it on old system? I cant locate any buttons. are they resetable? or I need to replace it? Thanks in advance!

  • @Powlashvac

    @Powlashvac

    3 жыл бұрын

    If it does not have a reset button it most likely resets when the PSI drops below the PSI that is set for that switch.

  • @eddiewohlfeil4194
    @eddiewohlfeil41947 жыл бұрын

    filters were probably dirty and before you got there the customer change them happens to me all the time.

  • @Powlashvac

    @Powlashvac

    7 жыл бұрын

    Customers never do that. Lol

  • @eddiewohlfeil4194

    @eddiewohlfeil4194

    7 жыл бұрын

    Lol

  • @KentuckyRanger
    @KentuckyRanger5 жыл бұрын

    Maybe the condenser needs cleaning? My Carrier Infinity system keeps throwing a code 84 High pressure lockout 4 hour shut down. I've been researching when I came across this video. I turned it off at the box, and it reset. The fan is ramping up properly, and the unit is only 4 years old. This is the second time it's done it in a month, so something fishy is going on. When I reset the system, it runs fine. I'm calling the installer tomorrow, because the unit is still well within warranty. I'm also going to take a hose and clean out the condenser.

  • @Powlashvac

    @Powlashvac

    5 жыл бұрын

    You may have a restriction in the system and makes it kick out. It may have to run for a period of time to get to the limit PSI.

  • @KentuckyRanger

    @KentuckyRanger

    5 жыл бұрын

    @@Powlashvac Thanks so much for the info!

  • @CollegeDreamJob

    @CollegeDreamJob

    5 жыл бұрын

    What ended up being the problem?

  • @KentuckyRanger

    @KentuckyRanger

    5 жыл бұрын

    @@CollegeDreamJob I carefully hosed out the coils, and the problem never came back since. It must have been just 3.5 years of dust and dirt clogging up the vanes. Dust and dirt came out pretty good, so it was my fault for not properly maintaining the condenser on a yearly basis.

  • @Powlashvac

    @Powlashvac

    5 жыл бұрын

    @@CollegeDreamJob That was never found, it has been running in AC and Heat every day forward fine so far.

  • @joerico9461
    @joerico94614 жыл бұрын

    The Amazon link that you have to the tool that you're using, without hooking up to the unit will not pull up. let us know what you're using that's pretty cool

  • @Powlashvac

    @Powlashvac

    4 жыл бұрын

    In the HVAC kit is the right item. They just have wrong photo. Its called Sporlan smart tool.

  • @joerico9461

    @joerico9461

    4 жыл бұрын

    @@Powlashvac thank you sir

  • @octobertravler1965
    @octobertravler19656 жыл бұрын

    Did they have a dirty filter and changed it before you arrived. I've had so many people do that to me. Lol. That of course could could cause your problem.

  • @octobertravler1965

    @octobertravler1965

    6 жыл бұрын

    What I mean of course is if it was like a lot of the ones I see totally stopped up that is gonna raise the head pressure. Then when they notice they have a problem they check their filter see that it's dirt then call us. Lol.

  • @garryludwick2990

    @garryludwick2990

    3 жыл бұрын

    Mine kicks the HP switch every time it goes into "Timed defrost. The aux heat is energized as normal but the refrigerator circuit trips the HP when it changes. I dont here the "Changeover valve like I used to. I reset it and it will run fine until it is time for defrost again. I do not suspect a refrigerant charge issue, .... Changeover valve maybe??? Help. Eubanks wall pack, heatpump, 10 yrs old.

  • @JohnnyHotspurGT
    @JohnnyHotspurGT5 жыл бұрын

    Hello Mike, Can you please tell us the brand and model of the wireless probes you used for pressure, I have looked at the Testo, but in your video I see something that appears much smaller and also appears to be a small round item, unless I am seeing things, also, do they give temp also ? I ask because the link you provided back then is dead. "This is the tool I use. Thanks for watching amzn.to/2jo0Up8" Thank you.Johnny

  • @Powlashvac

    @Powlashvac

    5 жыл бұрын

    Thanks for watching and this is the tool I use to dial in the charge of a system ebay.to/2XmdvvD

  • @denniss.1094
    @denniss.10944 жыл бұрын

    intermittent fault. Hard to find. if it does it again, still hard to find. if the fault is not active while you are there, start simple and low cost troubleshoot procedure first.

  • @cdelapaz5
    @cdelapaz55 жыл бұрын

    I've got a lenox unit. from the begining it was making a noise, a rappid clicking noise at the out side unit when running. They came out and said the defrost board was bad, so they changed that. Once they did, it seems, it started doing this thing were every once in a while with the thermistat on cold, the outside unit will not come on, the emergancy strips in the inside unit will come on, and the blower will run. And it wont stop until you shut the unit off for a long time, then it will work. So by the time the a/c guy comes out, everything works. He will say some bull crap line, which I'll tell him "that's not it, you'll be back" This time, I looked at it, I unplugged the heating elements, so that I could let the system run. I opened the compressor panel to find this high pressure switch kick out fault. I'm not understanding why it's kicking this out, and why it would ever turn the heat strips on with it in cold cycle. Oh yeah this unit is just over a year old, and its been doing this since day one. Not impressed with Lennox

  • @Powlashvac

    @Powlashvac

    5 жыл бұрын

    The last time I have seen something close to that, it ended up being the thermostat going in and out and turning on things that should not be on. Like in the middle of the summer turning on the heat strips. Let me know when it is found of what is wrong. Thanks for watching.

  • @jarmarcusblevins328
    @jarmarcusblevins3285 жыл бұрын

    It does take forever...ever..ever..ever

  • @Powlashvac

    @Powlashvac

    5 жыл бұрын

    Sometimes it does.