Why capacitor bank does not require in DG Set || Effect of Capacitor on Diesel Generator
Ғылым және технология
Dosto aaj es video ke andar hamne electrical mai upyog hone wala dg matlab diesel generator ka sath capacitor ka upyog kyu nhi kiya jata batane ki btane ki kosis kari hai. Sath hi aapko es video mai maine kuch electrical tips What is KVA and KW, what is factor, use of capacitor in electrical, KVA to KW calculation, what is Alternator or en sabhi ke sath mai aapko electrical working ke baare mai bhi practical jankari di hai. Ummed hai aapko yeh video bahut pasnd aayegi (hindi,urdu)
Thanks for visiting Here.
#DG # #DieselGenerator #capacitor #KVA #KW #powerfactor #Electrical #Interview #Electrician
अगर आप इलेक्ट्रिकल से जुडी पोस्ट हिन्दी में पढ़ना चाहते तो आप वेबसाइट इंजीनियरिंग दोस्त (Engineering Dost) को गूगल पर सर्च करे।
..................................................................................................................
Second Channel (दूसरा इलेक्ट्रिकल चैनल)
/ @engineeringdost
Check more videos:- / @electricaldost
Thanks for watching,,,,#electricaldost
Пікірлер: 233
दोस्तो हमारे इस नए चैनल को भी एक बार आप जरूर चेक करे। कुछ दिनों के अंदर मैं रोजाना यहाँ पर भी इलेक्ट्रिकल से जुड़ी वीडियो अपलोड करूँगा। kzread.info/dron/F9cJahy23HDhxiB2Lf6KRg.html
@AARIFKHAN-wh4oi
4 жыл бұрын
bhai mene camment kari he dheko or us par video banao
@AyanKhan-jt9bq
4 жыл бұрын
Thanks Bhai😊
@RkEasydrawing648
4 жыл бұрын
जरूर भाई
@RkEasydrawing648
4 жыл бұрын
जरूर भाई 💥🙏
@jitendrakumarsahu4087
4 жыл бұрын
Ok
Sir aap best ho...i wish collge mai bhi ase teacher ho to job milne ki tnsn na rhe👏😊😊
@celebrityfashion545
Жыл бұрын
Job 😂😂😂 small minds
Itna easy koan smjata h bhai awesome bhai
sahi jankari dete ho bhai thanks
@electricaldost
4 жыл бұрын
Thank you Boss ☺️
DG are normally limited in capacity, hence as a power source with a leading pf, are not advisable to have a directly connected capacitor bank…. A directly connected capacitor bank will immediately bring an over unity power factor to the DG which will trigger it to self-destruct by losing the voltage specially in unloaded conditions.. It is more preferred for a DG to have a lagging pf for a more reliable operation…typically around 0.8 pf for a more reliable operation… A DG being a limited capacity power source, any planned power factor corrections is switch on and off together with the load.... DG set output is often distorted and full of harmonics. These can cause harm to capacitors.DG set cannot take even light capacitive load, if this happens by chance.Load on DG can vary quite frequently, and capacitor bank cannot control it on continuous basis.Usually DG sers themselves are quite small in capacity, and capacitor bank is of not much use.
@copycatonlyoriginal6585
Жыл бұрын
Do we have any rules and regulations in place for this situation?
Great Great Great ATTITUDE Great superb superb.
Behtar jankari lagi aur aise video banaen
Very very nice sir jee bahut achha samjhane ka tarika hai sir jee
Thanks sir aapke video dekh k maine bahut sikha aur mera salection ho gya interview me pas ho gya
Very Useful Information.... superb sir
Bahut hi achha knowledge bhai
Bahut acha lgaa
You are the best sir
वीडियों बहुत ही अच्छा था
Bahi am Form Pakistan you're great & good instructor
Dost aapki video bahut achi hoti hai thanks dg ki neutral ko earth kyo kya jata hai please answer
Really helpful
Achha concept h Thank you
V good vedio, Thank u
Good knowledge
Excellent video👌
All doubt clear ..thank u sir
Very very thanks sir
Thanks sir 👍👍 have a great day
Good sirjee .thank you
Very very nice
Very good sir
Very nice and soo motivation for learning .this channel is very very amazing, enjoyable,and very very useful for learning.and bro your voice and teach strategy is also good and nice.well done bro.good job bro.
Bahot acchi bat batai Bhai Ek video relay settings par bhi Bana dijiye
Nice video sir jee
Useful for electrical student
Good explain 👌👍
Very useful video sir
AVR BOX mai kya lagate hai aur vo kaise work karts hai DJ ki information very helf full
SUPERB VIDEO
Supar work sir.
Nice Dear great
Thanks sir🙏🙏🙏🙏
Nice video sir
Solid information mila....
U r great bro
Agr 1000kva main 800kw load daal sakte hain. To with capacitor bank agr usme 800kw hi load dalu toh ?
amada terret punch press pega 357 ki jankari do
Good sir...
Very good
Nice info
Thank you so much
Good post
Avr sort hone ka karan pe video bnae
दोस्त आपकी सभी विडियो बड़ी💥 आसानी से समझ मे आता है इसके लिए आपके धन्यवाद मै प्रतिदिन आपका विडियो💥 देख रहा हूँ आपका गूगल साईट💥 भी विजिट करता हूँ लेकिन बहुत दिनो से आपसे रिक्वेस्ट कर रहा हूँ कि आप इलेक्ट्रिक्ल HV, LV पैनल, कन्ट्रोल पैनल, और इनके टेस्टिंग के ऊपर विडीयो अगर संभव हो तो बनाईये💥💥💥🙏🙏🙏
Nice explanation sir.!!
@electricaldost
4 жыл бұрын
Thank you Karan Ji ☺️🙏
Bilkul sahi hai
With lesser power factor say 60% Load Power factor = 0.6 DG rating in kVA = 1000 Load in kW = 500 Load kVA is required = 500/0.6 = 833.33 % of DG utilization = 83.33 With improved power factor using APFC say 85% Load Power factor = 0.9 DG rating in kVA = 1000 Load in kW = 500 Load kVA is = 500/0.9 = 555.56 % of DG utilization = 55.55 From the above it is clear that when power factor is improved the DG utilization for defined load say 500 kW is less and the burden on DG is reduced compared to the unimproved power factor. So isn't that good to connect APFC and maintain PF close to 90 to 95%? Can you pls explain what would be case if we connect a load of 750 kW with 0.6 PF, will the DG supply load current? Also one small suggestion instead of using 'KVA' pls use 'kVA'.
Good job Dost
Good one
Good.rsh
Thank u...
Thanks sir
भाइ अगर मै capacitor लगा के सिर्फ़ 700 kw use कर रहा हु तो क्या नुकसान है
Nice video
Formule pr video ek bana dijiye Jisme saare kw kvr kva convert karma ho
Mast video
👍👍
Please one video on basics of DG & APFC panel function
Best answer
Thank you sir🙏
@electricaldost
4 жыл бұрын
Shukriya NiTika Ji ☺️🙏
@nitikakulvi5977
4 жыл бұрын
@@electricaldost sir you are awesome 👌 I had made notes of your all videos and I revise it each day. Thank you for sharing your knowledge with us.🙏🙏🙏🙏
Thanks
Please make video about ac generator
Good sir DG se sambandh it puri knowledge pr video banao please
sir ek din pahle yeh vdo dekhta to interview pas hota
Can you please explain on why we designed AC voltage as 230v,440v & DC as 12v 24v 48v 72v?
👍🏻👍🏻👍🏻
Nice
sir, i have some confused..if capacitor use then increase voltage and current and power equal to product of vi then why power is not increasing..
Sir please motor ke running capacitor aur starting capacitor ke bare Mein batayein.
Thak you
Good morning to you sir. Please about what means pf tag in moter. Sir Jo moter main tag laga hota pf ka KIA matlab hota
Good
👍👍👍👍
Jay Jagannath sir 🙏 sir alternator and avr ka working principles vedio banaie please
Apfc used krte par iska load , total load me iskha load calculate krta h ya nhi
Always super...Sir aapne mere massage pr video nhi banayii.?
Bhai node and branch ke bare me video banai aur samjao
Sir please make video about chemical earthing
Sir imcc ka video banavo smart mcc kaise work krti he vo
Bhai aap bollard gate barriers ka control diagram bnao
👍
Transformers kei name plate padhaney key barey mey video banavo sir
Sir type of submersible ka vedio banao na sir please
Sir helecaptor me Kon sa motor use hota hai Bata a gea please sir
Sir mai ek stadium me mentanance ka job karta but os me jo tower light hai os me 2000watt ka single phase balb laga hai osko ham dg se opret kaise karenge keny k oska chock ignetar hai os k sath capiceter v laga hua hai espe thora bataye sir
Following are my Questions Regarding Capacitors on DG. We connect individual Capacitors near the Inductive Load only & we turn it on when the load is on. And when the load stops, the capacitor also shuts off. In this case following scene creat... 1) Capacitors leading current will cancelled the Inductive load current, & capacitors leading current doesn't move to DG Alternator. 2) We can save the Fuel consumption 4-5%. 3) Voltage regulation also good.
@samarsekharreddy
2 жыл бұрын
I feel same too but we can't increase much load by seeing ampere coming down bcz of capacitors
1. Ye batao capacitor ko add karne par load 800kw se 1000 kw kaise ho jayega 2. And ham 800 kw load fix hai to capacitor laga ke power factor improve kar rahe hai to kya nuksan hoga kyonki hamare equipment se bhi to power factor kam hota hai kewal alternator me hi loss to nhi hai na.?
servo moter ki drive ki jankari do drive ke card ki jankari do cnc ke servo alarm ki jankari do
Sir g mujhe electric bus ki wiring ke baare mein btayein
Dg me kon sa lube oil dalte hai, or dg ka kitna load connect kr skte hai (1250 kva ka dg hai)
Sir aap KVA ko current aur kW kis formula se nikalte hai.
Avr trip nai krta sir , generator control module trip krwaata hai generator ko during overloading
Sir DG pe ek details video banao na sir plz
Arc welding set 4kva pye kitne ka capacitor lage ga no load pe or load pe