What Size Inverter for 100Ah Battery - Sizing Battery for Inverter

Тәжірибелік нұсқаулар және стиль

🎁 Free Diagrams: cleversolarpower.com/free-dia...
📖 My Best-Selling book on Amazon: cleversolarpower.com/off-grid...
Victron Phoenix 12V 1200VA Inverter: cleversolarpower.com/go/CC12V...
In this video, I talk about what size inverter for 100Ah battery. Join me as I break down the complexities and provide straightforward answers to crucial questions like what size inverter for a 100Ah battery and how to size a battery for your inverter.
I'll cover everything from calculating the ideal inverter for both lithium and lead-acid batteries to exploring different voltages and capacities. Plus, I'll show you how to determine how long a 12V 100Ah can power a 1000W load.
When it comes to lithium batteries, I recommend sticking to a maximum of 1000W, while for lead-acid batteries, aiming for around 200W per 100Ah battery is ideal. By understanding these key principles, you'll be able to optimize your off-grid solar power system for maximum efficiency and longevity.
And don't worry-I won't leave you hanging when it comes to practical applications. I'll provide real-world examples and walk you through the calculations step by step, ensuring you have all the information you need to make informed decisions for your solar setup.
But that's not all. I'll also tackle the important question of standby power consumption and recommend the top-notch Victron phoenix inverter lineup, known for its superior performance and energy efficiency.

Пікірлер: 98

  • @cleversolarpower
    @cleversolarpower2 ай бұрын

    🎁 Free Diagrams: cleversolarpower.com/free-diagrams/ 📖 My Best-Selling book on Amazon: cleversolarpower.com/off-grid-solar-power-simplified Use coupon code: clever6 to get 6% discount for litime batteries: cleversolarpower.com/litime (cheaper than amazon)

  • @Ekanselter
    @Ekanselter2 ай бұрын

    Excellent as always!

  • @Techboxreview
    @Techboxreview2 ай бұрын

    Great Video. Informative and straight to the point. Well Done Mate 🤙🏻

  • @cleversolarpower

    @cleversolarpower

    2 ай бұрын

    I try to be straight to the point without any fluff 😉 thanks!

  • @sundaybassey5866
    @sundaybassey58662 ай бұрын

    Great video, keep it up

  • @marshall100w6
    @marshall100w65 күн бұрын

    Very interesting. Thank you.

  • @brushbum7508
    @brushbum75082 ай бұрын

    Good Evening ! Thank You. TAKE CARE..

  • @Electronzap
    @Electronzap2 ай бұрын

    Good info. There is no one size fits all. Need to pick each component based on the entire system.

  • @Techboxreview

    @Techboxreview

    2 ай бұрын

    Hey mate how have u been?. Hope you and your family are well

  • @linossinkala7840
    @linossinkala78402 ай бұрын

    Thankyou sir

  • @jwrhynejr.6689
    @jwrhynejr.66892 ай бұрын

    Thanks for sharing.

  • @eugen-m
    @eugen-m2 ай бұрын

    thank you for the presented material. recently I heard that photovoltaic panels can be equipped with optimizers. what they are and if they can be used in any situation.

  • @cleversolarpower

    @cleversolarpower

    2 ай бұрын

    Unless you have shade, I don't recommend using optimizers because the cost will outweigh the benefits. I made a video about 'different kinds of inverters' where i briefly touch upon these and microinverters. Check it out on my channel page.

  • @eugen-m

    @eugen-m

    2 ай бұрын

    @@cleversolarpower ok , thank you !

  • @stephenhickman9502
    @stephenhickman95022 ай бұрын

    Hello from South Carolina

  • @kpd3308
    @kpd33082 ай бұрын

    There is nothing wrong with using an oversized inverter. One reason would be to allow for future expansion. Just don't draw more power than your current battery system can handle.

  • @cleversolarpower

    @cleversolarpower

    2 ай бұрын

    I agree, it depends on the load.

  • @jacksionilopa3106
    @jacksionilopa31062 ай бұрын

    Very informative. I have a 100Ah AGM Lead Acid and a 120Ah AGM lead Acid batteries. My Invertor (MUST Invertor) is rated as 12V/1000W. I have an MPPT charge Controller rated as 150 MaxPVoc. What will be my set up?

  • @cleversolarpower

    @cleversolarpower

    2 ай бұрын

    Connecting the batteries in parallel is best. However, that's insufficient to run a full 1,000W load on it. It will work, but as I said in the video, it's not healthy for your battery.

  • @chadrogers3161
    @chadrogers31612 ай бұрын

    I've been using four sealed lead acid batteries with a 2000 watt 12V inverter powering washing machine that peak draw about 1800 watts. Been in service over one year now. I do 2-3 loads per week. So I'm apparently way under sized my battery bank?? Thank you for good informational video.

  • @jamesalles139

    @jamesalles139

    2 ай бұрын

    no. How deeply do your batteries become discharged (end voltage)

  • @chadrogers3161

    @chadrogers3161

    2 ай бұрын

    So I had to check again this AM pulls about 8.5 AMPS max load. Batteries lowest I've seen was like 11.4 volts after doing consecutive loads. And meter showed charge level only hit 50% briefly.

  • @jamesalles139

    @jamesalles139

    2 ай бұрын

    @@chadrogers3161 I don't agree with the premise of this video, but it isn't mine. For longer life 11.7 volts after resting is the _minimum_ (the less discharged, the better - recharge sooner). So S.O.C. is best to 50% of 12.7 to ? as rated by the Mfg. Other than that, you appear to be just fine, unless you _need_ longer operation from the battery. Carry on.

  • @chadrogers3161

    @chadrogers3161

    2 ай бұрын

    @@jamesalles139 yeah they are connected to three 100 watt solar panels so plenty of time in between uses to recharge.

  • @jamesalles139

    @jamesalles139

    2 ай бұрын

    @@chadrogers3161 That all seems right-sized to me. expect performance to suffer after 3-5 years

  • @lawrenceeneriko1567
    @lawrenceeneriko1567Ай бұрын

    informative video. I have a question.. I connected 2 solar panels of 100w each , to 3 12V batteries 2 of which have 100Ah each and 1 has 150Ah. I use 1000W inverter. However, the power often goes off at night but sometimes during day time. what could be the reason?

  • @cleversolarpower

    @cleversolarpower

    Ай бұрын

    Not enough solar to recharge the batteries. It depends on your load. Make a calculation and see how much you need. Checkout my video about sizing a solar system.

  • @herbertvonsauerkrautunterh2513
    @herbertvonsauerkrautunterh25132 ай бұрын

    I have 4x 48v 100ah rack batteries and a 5600 watt inverter.. I'll be buying another 4x batteries and also updating the inverter to 8 or 10kw. That's hybrid inverter/charger.. And 12-14 270w panels.. I use MPP inverter/chargers. They are good but have a higher standby current draw

  • @davelocke3245
    @davelocke324518 күн бұрын

    Great video. I love your animated pen technique... question: You suggest a fuse per battery prior to connecting to the bus in a parallel setup. The lithium batteries I use have a solid 200a BMS which shuts off with a short or other over-current situation. Is an MRBF fuse on each battery necessary? (the after-bus-bar [positive line does have a 200a fuse).

  • @cleversolarpower

    @cleversolarpower

    13 күн бұрын

    The BMS cannot disconnect a short circuit (high ICC) because it's an electronic switch. It's best practice to fuse every battery. Checkout nh00 fuses, they are quite cheap.

  • @trevorgeddis9044
    @trevorgeddis90442 ай бұрын

    Hi, Nick. I just came across your channel the other day and have learned a lot already after watching just a few of you tutorials. One thing that I learned... I have been making some very wrong assumptions about size and capacity. On my RV I currently have 2 - 100W solar panels, 2 -125 AH AGM batteries, all wired in parallel. I have them connected to a 40 amp EPever charge controller and to a 2500 W Sunforce Pure sine wave inverter. Problem... this set up will not run my microwave or coffee maker without tripping the cut-off circuit in the inverter. I have recently acquired two 300 AH Renogy Lifepo4 batteries, not yet installed. Will this solve the issue with tripping the inverter or am I missing something altogether? And do I need to resize my inverter to take the new batteries? Your comment or those from other followers of your channel will be greatly appreciated. Thanks.

  • @cleversolarpower

    @cleversolarpower

    2 ай бұрын

    Hello Trevor, answered your email.

  • @davidoanning1805
    @davidoanning18052 ай бұрын

    I have two 12v 120ah lifepo4 on 3000watt 24v inverter. My charge controller shutdown. I also have four 250 watt panels connected in parallel.

  • @SirTools
    @SirTools3 күн бұрын

    How does Gel batteries fit into this math ?

  • @user-km9kl4br6l
    @user-km9kl4br6l2 ай бұрын

    I have a Renogy 2000w Inverter with two Eco-Worthy 12.8v 100Ah lithium batteries in series. Am I properly sized?

  • @cleversolarpower

    @cleversolarpower

    2 ай бұрын

    2000W/12V=166A/0.9=185A max draw from inverter. A 100Ah battery can deliver 100A, so 100A x 2batteries = 200A. So you are properly sized.

  • @kaltimoktober
    @kaltimoktober26 күн бұрын

    2x12V100Ah in series and a 24V 1500W Inverter, was this the right move? I'm about to buy solar panels hence I found your channel and I'm amiss as to whether the same efficiency is used for Sealed Lead Acid vs Tubular Lead Acid for I was under the impression the latter shouldn't be allowed to discharge less than 50%? Should I opt to get a smaller inverter?

  • @cleversolarpower

    @cleversolarpower

    22 күн бұрын

    This will work. Every battery can deliver a max of 100A. Since they are placed in series, this is the max then can deliver, so each battery 50A. 1500W/24V=63A -> correctly sized.

  • @moondog8072
    @moondog8072Ай бұрын

    I have a Sungoldpower 4000w 12v inverter/charger in my rv with a LifePo4 12v 300ah battery. Is that too much inverter? I am adding another 12v 300ah LifePo4 battery in parallel for 600ah if that helps.

  • @cleversolarpower

    @cleversolarpower

    Ай бұрын

    I don't recommend going over 2200W for a 12V system. Your wires will be costly. Check my video about 12V,24V or 48V battery systems.

  • @adivasworld7466
    @adivasworld746612 күн бұрын

    I just ordered a 500W Bestek inverter to get myself acquainted with using inverters as an alternate power source. So in theory, 12V 50ah Lithium Battery suffices for 500W inverter based on calcs ... but do you still recommend a 12v 100ah lithium battery and, if so, why?...Without doing the calcs, it seems i can potentially get longer usage with the 12v 100a battery on a 500W inverter before recharging, but I would like to know your thoughts? I don't intend to max the load at one time, so my usage at this state in learning to use inverters would be light intermittent use (i.e a lamp periodically, charging my lap top periodically, charging phones , and maybe running my wifi for short intervals).

  • @cleversolarpower

    @cleversolarpower

    11 күн бұрын

    Of course, having a larger battery will make the fridge run longer, but it would also take longer to charge back up. I recommend getting the 12V 100ah battery, the price difference is not that much, about $250.

  • @adivasworld7466

    @adivasworld7466

    11 күн бұрын

    @@cleversolarpower Thank you!

  • @stefannordlander3158
    @stefannordlander3158Ай бұрын

    Hi m8. All fine here but like to ask for your thinking about my coming setup. Lets start with my needs, no im in the Philippines wery south so its little diffrent. Main who needs regular power is refigerator for beer and freezer for the bbq.. joke but its the main thing we really need. Also a few fans running dayly will be needed. Have some clue about power, ill add 20% refrigerator 100w freezer 100w, fans and accesory 200w. Some rarely use of microwave. Can you give me a thumb what i need ? My own estimate is as follow. 3x600w panels and 4 batterys for cooling and 2panels + 2 batterys for others separeted. Seems ok?

  • @cleversolarpower

    @cleversolarpower

    Ай бұрын

    Checkout my video about designing an off grid solar system as well as my calculator on my website.

  • @tedjelsema782
    @tedjelsema7822 ай бұрын

    I have 3 12V 20Ah LiFe batteries, if paralleled what watt inverter is best? 650W or 600W

  • @cleversolarpower

    @cleversolarpower

    2 ай бұрын

    You have a 12V 60Ah battery. At 1C, you can pull 60A max. Assuming the BMS is rated at 1C as well. 650W/12V=54A. So you can run a 650W load.

  • @printsomething5093
    @printsomething509314 күн бұрын

    Question, I'm looking at the Victron Inverter mainly because of there efficiency and the low draw when idle. Know this might be a stupid question but the idle draw that's only when the are turned on correct? If i have it switched off it shouldn't drain, correct??

  • @cleversolarpower

    @cleversolarpower

    14 күн бұрын

    Yes, if you turn it off it's 0. If you turn it on it consumes power even when nothing is attached to it.

  • @jasonsmith2430

    @jasonsmith2430

    13 күн бұрын

    That what I thought, thank you

  • @Supanova70
    @Supanova7022 күн бұрын

    If i have flooded 12v batteries that are combined 168AH. Is that really what is available or do i will i only get 80% out of them which would be 135.? I am setting up a battery monitor. thanks

  • @cleversolarpower

    @cleversolarpower

    22 күн бұрын

    If you have flooded lead acid batteries, you should only use 50% to increase the lifespan. You can use more, but that would reduce it's lifespan. Check the capacity of the battery with a voltage meter.

  • @Robertmillsjr
    @RobertmillsjrАй бұрын

    Thanks for the great videos, I'm also using your website links to buy your recomendations on amazon. I currently have the MPP Solar All in one unit: 12v 1000w inverter, 40A solar charge controller, and 20A AC charger. I'm having trouble figuring out how many batteries I can add in parallel. I crrently have a 12v 200AH Li Time battery and want to add a second 12v 200AH Li Time battery. Can my inverter handle that much current? And are the 40A solar charger and 20A charger enough to charge 400ah? I've allready bought the 12V system, and I can't afford to switch to 24V. ;)

  • @cleversolarpower

    @cleversolarpower

    Ай бұрын

    More batteries is better (most of the time). You got to see that the system is still properly sized. Batteries should have 3 days of autonomy. So if your daily consumption is 800Wh, then you don't need an extra battery. You can charge the batteries with 2A, the charging current doesn't matter that much, it just impacts charging time.

  • @Robertmillsjr

    @Robertmillsjr

    Ай бұрын

    @@cleversolarpower thanks! Very nice of you to help people out.

  • @Robertmillsjr

    @Robertmillsjr

    Ай бұрын

    @@cleversolarpower one more question, if I add a Li Time 200ah battery with a 100amp BMS, to my existing Li Time 200ah battery, in parallel, do I use a 125amp MRBF fuse on battery #1, and a 250amp MRBF fuse on battery#2? I watched your videos, you said fuse each battery in case of short circuit overload, but still having difficulty understanding fuse sizing when two batteries parallel.

  • @scottpalmer3156
    @scottpalmer315627 күн бұрын

    I have a 3000 watt inverter, on a 100 amp battery, can I use a splitter to truck battery, to keep charged, only running 12 volt Rv fridge and a800 watts microwave?

  • @cleversolarpower

    @cleversolarpower

    22 күн бұрын

    I'm not sure what you mean by splitter. You can add multiple connections to a battery. However there should be a maximum of 3 connections per battery post. If your system exceeds this, use a busbar. You can add your inverter + charger to one battery.

  • @CoolStuff..
    @CoolStuff..2 ай бұрын

    cool

  • @logan66680
    @logan66680Ай бұрын

    If I have a 180 W inverter for my Travel trailer.How big of a lithium battery can I get to max out that 1800 watt inverter?

  • @cleversolarpower

    @cleversolarpower

    Ай бұрын

    Assuming you have a 12V lithium battery, you can draw a max of 100A, that's 12V*100A=1200W max draw from one 12V 100Ah lifepo4 battery.

  • @judenoukui550
    @judenoukui5502 ай бұрын

    Any free diagram for this?Really interesting.

  • @cleversolarpower

    @cleversolarpower

    2 ай бұрын

    There are no diagrams for this because it's mostly math. I do have free diagrams, check the link in the description😉

  • @nomsTube
    @nomsTube4 күн бұрын

    Can a 500W inverter be used to charge 100AH Lifepo battery also instead of 1000W?

  • @chadjs74
    @chadjs747 күн бұрын

    So if I have two 12.8v 20ah batterys run in parallel then I should use a 500w inverter just using it for camping

  • @cleversolarpower

    @cleversolarpower

    7 күн бұрын

    Correct.

  • @chadjs74

    @chadjs74

    6 күн бұрын

    @@cleversolarpower if I used a larger inverter like a 600 watt or 1000w would it damage the batterys

  • @infinitylife213
    @infinitylife21314 күн бұрын

    Dir sir I have 6kw inverter how many kilo watt batteries in need

  • @cleversolarpower

    @cleversolarpower

    13 күн бұрын

    Just repeat the calculations in this video for your inverter.

  • @johannsteyn3030
    @johannsteyn30302 ай бұрын

    I have a 1000 watt inverter a 555 watt panel and a 102 amph battrie. Runs a fridge and wifi on it day and night.

  • @nathan549
    @nathan5492 ай бұрын

    Is it possible to run a 2000w inverter on a 100ah battery with a 700w microwave?

  • @cleversolarpower

    @cleversolarpower

    2 ай бұрын

    No, because the c rate of lithium is 1. You can discharge a max of 100A with the BMS.

  • @kleineroteHex
    @kleineroteHex2 ай бұрын

    I wish I understood this stuff better 😕 I will just listen.

  • @cleversolarpower

    @cleversolarpower

    2 ай бұрын

    Take notes 😉

  • @LeeDaiYing
    @LeeDaiYing2 ай бұрын

    ❤❤❤

  • @ourworldandnature158
    @ourworldandnature15816 күн бұрын

    2 bateri (accu) 12 v 100 ah end inver 2000 w

  • @jsdk84
    @jsdk842 ай бұрын

    I am only a beginner.I have a 25w panel and a 7 ah LA battery.

  • @1GREATDANE
    @1GREATDANE21 күн бұрын

    24 Volt 3.8K Lithium Iron Phosphate Big Battery with 100amp BMS Handle a Victron Phoenix 24/1200 Inverter or a WZRELB 24 Volt 2500 Watt Inverter ??

  • @cleversolarpower

    @cleversolarpower

    19 күн бұрын

    1200VA/24V=50A -> yes, 2500W/24V=104A -> no (if you draw the full 2500W)

  • @dennisspino2607
    @dennisspino26072 ай бұрын

    I have 3-100ah Mighty Max lithium batteries hooked up in series

  • @cleversolarpower

    @cleversolarpower

    2 ай бұрын

    With what inverter?

  • @dennisspino2607

    @dennisspino2607

    2 ай бұрын

    @@cleversolarpower I have 2, a 2000W Power Tech-On and a 1200W Victron Phoenix both are 12V I don't have either one maxed out. Thank you for all your info I find it very informative

  • @dennisspino2607

    @dennisspino2607

    2 ай бұрын

    @@cleversolarpower I have 2 a 12v /2000w Power Tech - On and a Victron 12/1200 Phoenix I like this one a lot. Thank you for all your helpful information.

  • @cleversolarpower

    @cleversolarpower

    2 ай бұрын

    Thanks for your reply.

  • @seanbritish
    @seanbritish18 күн бұрын

    If you use it in a hybrid its always using from the main system

  • @eddykbee8308
    @eddykbee83082 ай бұрын

    How about GEL batteries]

  • @cleversolarpower

    @cleversolarpower

    2 ай бұрын

    Gel and AGM are in the same category as lead acid.

  • @eddykbee8308

    @eddykbee8308

    2 ай бұрын

    @@cleversolarpower Aa thanks for claryfiing

  • @rami4073
    @rami4073Ай бұрын

    Do you mean, brother, that we cannot use more than 40 amps for a 200 amp acid battery? This would be excellent, please.

  • @cleversolarpower

    @cleversolarpower

    Ай бұрын

    You can, but it wouldn't be good for your battery or efficiency. 40A is the max you should draw, not what you can draw.

  • @rami4073

    @rami4073

    Ай бұрын

    @@cleversolarpower thanx my dear

  • @solarsystem-rs9pd
    @solarsystem-rs9pd2 ай бұрын

    24v 200ah load 500w

  • @cleversolarpower

    @cleversolarpower

    Ай бұрын

    Very well sized.

  • @MohamedmBangura-ll7kh
    @MohamedmBangura-ll7kh2 ай бұрын

    Even 500watt inverter with a 60watt load can not be connected on lead acid battery 100ah

  • @cleversolarpower

    @cleversolarpower

    2 ай бұрын

    I assume you are talking about lead-acid? Of course it can. A 500 inverter is not the same as a 500W load. If you have a 60W load, then you get a total of 70W (including 10W of the inverter). Maxing out the inverter is not a good idea (500W) because it will shorten the lifespan of the battery.

  • @Chris-dg5bf
    @Chris-dg5bfАй бұрын

    I have a 1200watt inverter on a 100ah battery, I will just be careful not to go over 1000.

  • @cleversolarpower

    @cleversolarpower

    Ай бұрын

    Yes, otherwise the BMS will shut down. The inverter has inefficiency as well. Usually 90%. So the max you can draw on the AC side is 1080W AC.