UV Light Installation

Clean Comfort UV Light Install

Пікірлер: 70

  • @seacaptaindw
    @seacaptaindw2 жыл бұрын

    Nice video. I would have liked to see the hole drilled.

  • @dspeurope4388
    @dspeurope43882 жыл бұрын

    Nice information Thanks

  • @DrewNutts
    @DrewNutts3 жыл бұрын

    tail light guarantee!! love it!! lol

  • @williammarik6159
    @williammarik61593 жыл бұрын

    You need to show the low-voltage end. This is where the problems start. Many of these things require a relay .

  • @valricojoe7659

    @valricojoe7659

    2 жыл бұрын

    There is no low voltage end with this unit, it is 24 VAC to the bulb, so there is a transformer in the base unit 120 VAC to 24 VAC

  • @mr.unknowncali-life9350
    @mr.unknowncali-life9350 Жыл бұрын

    I have white mold I believe not sure growing by the system in my attic behind the blower where it drips and slide down to the drain pan. What the best way to wipe it or clean with what chemicals inside the HVAC system?

  • @tc1uscg65
    @tc1uscg653 жыл бұрын

    At some point, you mentioned 24v, however, the installation shows the tech plugging into a standard outlet. At the beginning of the video, I thought he was going to show how he wired it to the main board of the unit so the light comes on when the furnace/ac is on but that wasn't the case. Appreciate the video and the location info. Just pointing out the voltage question.

  • @jasongiannone1229

    @jasongiannone1229

    3 жыл бұрын

    It’s recommended to shine continually on the coil- however it can be wired to the air handler board if desired

  • @valricojoe7659

    @valricojoe7659

    2 жыл бұрын

    The 120 VAC to 24 VAC transformer is in the base unit. You could wire in a relay to control the 120 VAC feed to the unit.

  • @jimpie231
    @jimpie2312 жыл бұрын

    In my installation, I have a bypass humidifier installed on the return line about 5 1/2 ft above the floor tubing going to the plenum above a packaged A coil. The plenum above the packaged A coil is about 15” then goes into a flex connection for about 2” then another 15” plenum, then into the main trunk delivering heat or air depending on the weather/time of the year. Where would I install the UV light? Thanks….Jim PS……my Trane furnace electronic board has many places to trigger different things like a humidifier, electronic air cleaner (which I’ve always had & do now), etc. I would like to know why you’re not triggering the UV light to be on with only the furnace/air is on? Thanks again!

  • @jasongiannone1229

    @jasongiannone1229

    2 жыл бұрын

    Anywhere in the Plenum is OK or even in the supply ideally you would like to have it shining down on your a coil if possible also you can wire it to only shine when the blower of your furnace or air handler comes on however you can leave it on continuously as well hope that helps

  • @francispaul1266
    @francispaul12662 жыл бұрын

    Hi. Thanks for the video. I bought swordfish uva36wb 36watts. It doesn’t have reflective shield. Is that okay

  • @jasongiannone1229

    @jasongiannone1229

    2 жыл бұрын

    Yes

  • @marjunbudburan593
    @marjunbudburan5932 жыл бұрын

    Great video. Can you help me of where is the best location of UV to install for purpose of sterilizing operating rooms in the hospital? Is it in return side or after the coil?

  • @jasongiannone1229

    @jasongiannone1229

    2 жыл бұрын

    Always put it in the supply side above the coil. You can put it on the return however you would want the light shining on the coil at all times to prevent mold from building up on the coil. Hope this helps

  • @thegoodolvet5586
    @thegoodolvet55863 жыл бұрын

    Should’ve installed it in coil section,either in A of coil or above coil... any way to hook up to board so it shuts on and off with unit?

  • @jasongiannone1229

    @jasongiannone1229

    3 жыл бұрын

    Yes you can wire it to the air handler direct, however to get the most effective results it should shine continuous on the coil to kill any bacteria or viruses

  • @valricojoe7659

    @valricojoe7659

    2 жыл бұрын

    Not without a 120 VAC DPDT relay and a bunch of wiring.

  • @daryn1231

    @daryn1231

    2 жыл бұрын

    You wouldn’t want to install it in the A coil. That’s very damp and if the condensation dripped down on the unit or worse if the bulb were to break or become dislodged the results could be catastrophic. 🔥🔥🔥

  • @formfanone
    @formfanone2 жыл бұрын

    Very clear and well presented. Thanks. One question about drilling the hole - what do you use to drill the hole and how do you ensure that the round piece of metal that you cut out does not fall into the plenum and can't be retrieved?

  • @jasongiannone1229

    @jasongiannone1229

    2 жыл бұрын

    Hi- you can use sheet metal snips- just bend it towards you as you cut the hole

  • @terrymonday3495

    @terrymonday3495

    2 жыл бұрын

    You could also put a screw in the center of the cut out area and use that as a handle.

  • @danialromany9060
    @danialromany9060 Жыл бұрын

    How much mold miser max?

  • @bikerleathertv
    @bikerleathertv2 жыл бұрын

    Do these UV lights, clean an already dirty (due to age) coil or only keeps it from becoming dirtier? Thanks.

  • @jasongiannone1229

    @jasongiannone1229

    2 жыл бұрын

    It’s recommended to clean the coil first and then have the UV light to prevent mold build up in the furure

  • @billnipp2309
    @billnipp23093 жыл бұрын

    How long do the bulbs last typically? Is there any maintenance? And are new bulbs expensive? Ty.

  • @valricojoe7659

    @valricojoe7659

    2 жыл бұрын

    1 year for this unit, there are two year systems out there now as well.

  • @sassylady2001

    @sassylady2001

    2 жыл бұрын

    Effectiveness of the UV goes down with time even if the light still shines. Replace annually.

  • @valricojoe7659
    @valricojoe76592 жыл бұрын

    The UV light does not clean the air, it only cleans the top of the coil. Not enough exposure time for UV to kill stuff in the air.

  • @jasongiannone1229

    @jasongiannone1229

    2 жыл бұрын

    Thanks for your comment- it actually does clean the air however- as air passes through the light, the light removes particles and VOC’s

  • @wind5250

    @wind5250

    2 жыл бұрын

    @@jasongiannone1229 it doesn't clean the air , that's not even how uv light works. Uv light breaks apart the dna in biological life forms . It reduces odors/bacteria /viruses because they are primarily organic. The previous poster was mostly correct as the uv light does not have enough time to kill much accept for what's on the coil. These lights reduce the in air concentration of active bio matter by multi pass radiation exposure via air circulation . The air isn't cleaned at all in fact it contains the same amount of biological matter, how much of it that's alive / active is simply reduced as it's hit by uv light multiple times. Most of the uv lights sold simply do not have enough power to do very much to anything in moving air. If we use the systems in hospitals as an example a unit that size would have at least 6 times as many bulbs as what was placed in the video. They would be placed on all sides of the coil , by the blower and in the duct creating 3 stages to increase the exposure times and keep the most heavily contaminated parts of the system clean at all times.

  • @MrBababuwi

    @MrBababuwi

    2 жыл бұрын

    @@wind5250 What you've said in a paragraph, Jason already said it in a sentence. If UV light reduces odors.......isn't the air clean?

  • @wind5250

    @wind5250

    2 жыл бұрын

    @@MrBababuwi No it isn't and no he didn't . Cleaning the air would be a filter like a hepa filter since it captures the particles and biomatter. A uv light doesn't capture anything thing that's like asking if you fill a dirty sink with water did you clean it while all the dirt is still in the water. A strong enough uv light kills living organisms like live viruses making it damn useful but saying it cleans is a stretch.

  • @AndreaChiaraJohn

    @AndreaChiaraJohn

    Жыл бұрын

    @@wind5250 Thank you for all the comments. The UC36D16 UVC Purifiers does treat the coil and the passing air. These units feature high UVC output lamp which radiate high amount of Germicidal UVC rays which radiate out and create inactivation zone. The UVC rays can inactivate some microorganisms in a second. Sometimes the air moves faster sometimes at low speed. Air Cleaners capture particulates and some microorganisms. That is why you need both - engineered Air cleaner and UV purifier.

  • @markkaminski4028
    @markkaminski40282 жыл бұрын

    The unit I have is 24 volt but is linked to the furnace 24 volt furnace circuit board such that it only comes on when the fan operates... otherwise, it seems to me that what you've installed is running 24/7/365 (which strikes me as unnecessary). Mine is on the return side... so it's not doing the coil-neutralization thing.

  • @scott_litch
    @scott_litch3 жыл бұрын

    I have a humidifier installed on the plenum above the coils. Can I put the light near the humidifier? Also, I have a vent higher up on the same plenum for the basement. Will light escaping from the vent be a problem?

  • @jasongiannone1229

    @jasongiannone1229

    3 жыл бұрын

    Preferably you would like to have the UV light about 9-12” above the coil. If you dont have room you can put it above the humidifier no problem, it will still purify the air but may not shine down on the coil as much. Also the light has a reflection sheild so if its shining downbit wont leak out of the vent.

  • @scott_litch

    @scott_litch

    3 жыл бұрын

    @@jasongiannone1229 Thanks for the response! I have the room to install it. It could go behind the humidifier entering the plenum from the side, but I've read that the UV light can do damage to the humidifier over time. I checked Aprilaire's website and it even says the plastic housing is UV resistant, but not UV proof. I'm honestly wondering if it's worth installing a UV light at this point. While eliminating mold, mites, et cetera would be great, I don't know if I want to risk damage to my humidifier.

  • @jasongiannone1229

    @jasongiannone1229

    3 жыл бұрын

    @@scott_litch it os recommended to install above the coil, however some contractors install these in the return as well- the goal is to get the air in your home passing through the light to eliminate particulates, either way should still clean the air, return installs just wont shine on the coil

  • @valricojoe7659

    @valricojoe7659

    2 жыл бұрын

    @@scott_litch There are other products out there, where you can put a TUV BTER2 system on the return side of the coils. Video's available on the interweb.

  • @tammymyers8447
    @tammymyers8447 Жыл бұрын

    Great video! I just ordered one. PROBLEM IS, I can see mold in my downstairs ducts when i take the vents off. HELP!!!

  • @jasongiannone1229

    @jasongiannone1229

    Жыл бұрын

    That’s an easy fix- just clean it!

  • @jerrygrayson8421
    @jerrygrayson8421 Жыл бұрын

    I want a uv light above my ACoil but I have already installed a whole house humidifier there . I have install a uv light in the return plenum as a compromise but really want the uv above the coil but think it will degrade the plastic frame of the humidifier. Please help.

  • @jasongiannone1229

    @jasongiannone1229

    Жыл бұрын

    Most UV lights have a reflective shield on them- as long as the UV has room to fit directly above the coil and underneath the humidifier- none of the light will go up( or very minimal).. Also the UV shining on the coil helps keep it clean from build up- however anywhere in the supply will help clean the air- especially if you have one in the return and one in the supply- you should be knocking out most VOC’s. Also you can consider an electronic filter- paired with UV, electronic filters can be an excellent way to make sure the air over running over the coil is free of dust, and many other pollutants. Hope that helps

  • @dillonotts6150
    @dillonotts61502 жыл бұрын

    So these lights are mounted in the plenum above the a coil?

  • @jasongiannone1229

    @jasongiannone1229

    2 жыл бұрын

    Yes that is correct

  • @BeeBombard
    @BeeBombard3 жыл бұрын

    So it’s on even when the furnace is not running? That would just burn the bulb out quicker wouldn’t it?

  • @jasongiannone1229

    @jasongiannone1229

    3 жыл бұрын

    The bulb gets 9000 hours of life- you want it shining continuously to kill anything that may build up on the coil

  • @sassylady2001

    @sassylady2001

    2 жыл бұрын

    No, it won't. Most lights wear out faster when switched on and off. If you notice on an incandescent bulb, it only burned out when it was switched on. It never burned out while current was traveling through it - only when it was off and the filament was hit with a sudden jolt of current. Same idea here.

  • @soydelrancho

    @soydelrancho

    2 жыл бұрын

    Actually light bulbs will last a lot less if they turn on and off frequently

  • @Chris-uh7nm
    @Chris-uh7nm2 жыл бұрын

    How do you know if your UV light bulb is good? There are two warning lights at the power source of my Comfort UV Light. One is for the power and the other is for the bulb. If the bulb is removed the warning light for the bulb is off. I put the bulb back on and the warning light turns on. However, how can I see if the bulb is actually on if I cannot see through the outer shell of the fan coil unit?

  • @jasongiannone1229

    @jasongiannone1229

    2 жыл бұрын

    Good question-usually there is a small opening or area of the Air Handler or coil cabinet that isn’t completely sealed where you can see the light shining. Other wise you can always drill a small hole with a drill bit to see if it’s on and cover it up with silver tape. Hope this helps

  • @AndreaChiaraJohn

    @AndreaChiaraJohn

    Жыл бұрын

    The LED at the front of the unit is the sensor showing you if the lamp is on or not. If the LED is light, the light is working.

  • @edkhoshaba170
    @edkhoshaba1705 ай бұрын

    How much is it

  • @carolinealter5587
    @carolinealter5587 Жыл бұрын

    How do I find out what light to order? Does the model of AC matter?

  • @jasongiannone1229

    @jasongiannone1229

    Жыл бұрын

    No this will work on any AC system. Any UV light will work from Clean Comfort or you can check out the “dust free active”

  • @terekn2915
    @terekn29153 жыл бұрын

    Where do you buy these units?

  • @jasongiannone1229

    @jasongiannone1229

    2 жыл бұрын

    Your local HVAC distributor should have some form of UV lights available

  • @joywinnett6192
    @joywinnett61923 жыл бұрын

    Where can I get this my heating-cooling guy wants to charge me $700 and I want to do myself.

  • @jasongiannone1229

    @jasongiannone1229

    3 жыл бұрын

    Your local plumbing and HVAC distribution should have sometging similar

  • @rosemaryb6413
    @rosemaryb64132 жыл бұрын

    Have you heard if Thes uv lights leak ozone?

  • @jasongiannone1229

    @jasongiannone1229

    2 жыл бұрын

    They produce the same amount of ozone as any household appliance like a toaster for example- however through the ionization process these units actually have a negative ozone footprint.

  • @sassylady2001

    @sassylady2001

    2 жыл бұрын

    The amount of ozone they can leak is controlled - there are legal limits.

  • @androsoctaris5967
    @androsoctaris5967 Жыл бұрын

    $1,500 to install, in my area.

  • @mr.unknowncali-life9350

    @mr.unknowncali-life9350

    Жыл бұрын

    1000 in mine dam !

  • @tomk3635

    @tomk3635

    Жыл бұрын

    That’s insane! Waste of money…no would pay an additional $250 at time of install. My AC guy wanted $450 at time of installation, the light itself cost $100. Any basic electrical sense and you can do yourself. Not hard at all.