UT Tip Diffracted Signal

This video demonstrates how to measure the depth of an EDM notch using the tip diffracted signal.
Equipment: Olympus EPOCH 1000i UT tester, 45 degree, 4Mhz, 10mm diameter transducer and a carbon steel bar that contains a 0.300" high ID connected EDM notch.
I work at Central Piedmont Community College in Charlotte, NC. Please visit our website to explore your NDE training needs.
Central Piedmont Community College NonDestructive Examination Technology Program
www.cpcc.edu/programs/nondest...
Central Piedmont Community College NonDestructive Examination Technology Program College Catalog
catalog.cpcc.edu/programsofstu...

Пікірлер: 6

  • @arifbugga7186
    @arifbugga71863 жыл бұрын

    you are very honest sir.

  • @ahmedmusawi5425
    @ahmedmusawi54254 жыл бұрын

    Very educational thanks.

  • @arifbugga7186
    @arifbugga71863 жыл бұрын

    can you make a video of mode conversion

  • @programmerdave9425
    @programmerdave9425 Жыл бұрын

    Just to add on this, if you wanted to measure the height of an imbedded crack, you'd need a top and bottom tip and measure the difference between those.

  • @rodstephens742

    @rodstephens742

    5 ай бұрын

    Part T - depth of diffracted signal = through-wall height

  • @programmerdave9425

    @programmerdave9425

    5 ай бұрын

    @@rodstephens742 some clients require actual flaw height. Not all cracks are id or od connected.