UT Lack Of Sidewall Fusion Signal

This video demonstrates the Ultrasonic Testing signal when inspecting a weld with lack of sidewall fusion. Equipment: Olympus EPOCH 1000i UT tester, 60 degree, 4Mhz, 10mm diameter transducer, 0.625" in thick carbon steel plates with single V 30 degree bevel.
I work at Central Piedmont Community College in Charlotte, NC. Please visit our website to explore your NDE training needs.
Central Piedmont Community College NonDestructive Examination Technology Program
www.cpcc.edu/programs/nondest...
Central Piedmont Community College NonDestructive Examination Technology Program College Catalog
catalog.cpcc.edu/programsofstu...

Пікірлер: 7

  • @RandomStuff-zs6cw
    @RandomStuff-zs6cwКүн бұрын

    Wonderful Sir 😊

  • @dudeabc100
    @dudeabc1003 жыл бұрын

    Hi sir, nice video! From the upstream side this Side wall lack of fusion can be seen on the third leg. Sometimes based on the LOF geometry or slag inclusion coupled with LOF you could possibly see it on the 2nd leg as well from the upsteam side.

  • @ahmedadil939
    @ahmedadil9393 жыл бұрын

    thanks so much

  • @abinashsahu6445
    @abinashsahu64453 жыл бұрын

    nice sir

  • @oluwabiyi30
    @oluwabiyi30 Жыл бұрын

    What was your screen range?

  • @geemarino6066
    @geemarino60662 жыл бұрын

    Can you demonstrate to us the high low weld...

  • @paulmarino8308

    @paulmarino8308

    2 жыл бұрын