UT Lack Of Sidewall Fusion Signal
This video demonstrates the Ultrasonic Testing signal when inspecting a weld with lack of sidewall fusion. Equipment: Olympus EPOCH 1000i UT tester, 60 degree, 4Mhz, 10mm diameter transducer, 0.625" in thick carbon steel plates with single V 30 degree bevel.
I work at Central Piedmont Community College in Charlotte, NC. Please visit our website to explore your NDE training needs.
Central Piedmont Community College NonDestructive Examination Technology Program
www.cpcc.edu/programs/nondest...
Central Piedmont Community College NonDestructive Examination Technology Program College Catalog
catalog.cpcc.edu/programsofstu...
Пікірлер: 7
Wonderful Sir 😊
Hi sir, nice video! From the upstream side this Side wall lack of fusion can be seen on the third leg. Sometimes based on the LOF geometry or slag inclusion coupled with LOF you could possibly see it on the 2nd leg as well from the upsteam side.
thanks so much
nice sir
What was your screen range?
Can you demonstrate to us the high low weld...
@paulmarino8308
2 жыл бұрын
Hahahha