Types of AC compressor problems that often occur that make the air conditioner not cold
Тәжірибелік нұсқаулар және стиль
Description
back again with johan technique
this time we want to share a little experience about this type of problem with the triplec compressor, which often happens
2. The compressor is overheating and the amperage is high
when the compressor overheats and high amperage due to overheating of a compressor caused by several factors including:
a. ac is dirty, especially in the outdoor
b. inappropriate outdoor placement
c. compressor lack of lubrication
d.Voltage Drop below 220 V
e. the compressor is weak
3. The compressor is stuck or the compressor doesn't want to start, in general, it only makes a buzzing sound, even though the capacitor is in good condition. The cause that we often encounter is
a. voltage pln Drop. which causes the compressor when working becomes heavy due to lack of power over time the compressor will heat up the amperage will increase.
b.ac is not maintained, especially on the outdoor unit.
4. Compressor short or short circuit for easy-to-know features, usually when the indoor is turned on and the outdoor starts to turn on, the MCB will go down or trip.
5. Compressor damage caused by coils inside the compressor breaking or burning.
Пікірлер: 68
Trimakasih bung Johan, info berguna yg cukup jelas terinci.. 👍🙏
Mantap informasinya, terimakasih, salam dingin, sehat dan bahagia selalu om Johan 🤲👍
Semangat lur 💪💪
Mantab bg jon, semangat
Dari nonton channel tentang ac ....cuma di channel yg paling lengkap ....penjelasan nya
hadir om
Salam kenal kang... *pendatang baru*. Matursuwun sudah berbagi ilmunya .. kebetulan aku sedang belajar memperdalam ilmu per AC an. Tetap semangat..semoga sukses YT nya 👍😊
@JohanChannel
Жыл бұрын
Amin sami2 mas🙏
Bagmn cara pilih kompresor second yg masih layak pake....???
Kalau kita dapat pastikan compressor ac kita overheat, dan kita tukar overload baru, adakah ac kita kembali ok?
om nanya, kl kompresor 1 pk bisa ga kerjanya dijadikan separuh kapasitas, misalnya dijadikan ¾ pk atau ½ pk dengan cara memberikan freon separuh kapasitas atau tidak sampai full. maksud saya agar dayanya ga sampai maksimal... tks
Indikasi "kompresor Lemah" maksimal presure brp psi......??
Mas ini sy pny AC 1\2 PK panasonic bl mn AC di hidupkan di set up temperatur molai min sampai max 17-24’kok g da perubahan ga dingin jg ga hangat sejukkk terus knp y mohon ..dan apa permasalahanya mohon penjelasanya..
Bagaimana caranya untuk checking overload
Tanya bang jhon, solusi kompresor press balik
@JohanChannel
10 ай бұрын
Pres balik nya saat hidup atau saat mati Mas.dan biasanya yg saya lakukan kompresor saya bolak balik berkali kali sampai oli keluar dari akumulator kadang berhasil.
Klo outdoor mati hidup (fan & kompresor) saat suhu udara panas indikasinya yg rusak mana bang? klo udara dingin malah ga mau mati
@JohanChannel
Жыл бұрын
Cek tekanan freon dulu mas
Selamat malam.saya mau tanya kalau pasang AC di meter listrik tertulis daya lebih.padahal sebelumnya aman2.apakah yg bermasalah Ac, atau??
@JohanChannel
10 ай бұрын
Daya kwh brapa ac brapa PK
mau tanya mas kenapa ya mas pipa outdoor engak berembun sedangkan pipa indoornya berembun kenapa ya mas
@JohanChannel
Жыл бұрын
Indoor dingin normal atau tidak mas
Klo AC 1/2pk r 32, Amphere menunjukkan 1.3 tp tekanan freon gk mau naik hy di angka 40/50 psi,itu kira2 apanya ya lur?
@JohanChannel
Жыл бұрын
Antar kompresor lemah cek kompresor tanpa beban berapa kompresi yang dihasilkan
Ijin tanya bang johan klu misal mcb ngetrip ketika outdoor nyala berarti kompresor short atau konslet lgkh apa yg harus dilakukan spy kompresor bisa running lagi selain ganti kompresor makasih
@JohanChannel
Жыл бұрын
Yang harus dilakukan ganti kompresor baru mas
@wirabajaringan8796
Жыл бұрын
@@JohanChannel baik bang johan makasih
bang Awalnya dingin, 10 mnt kemudian gk dingin dan kompresor panas lalu ac mati, apa kompresor diganti, trims
@JohanChannel
7 ай бұрын
Pastikan ac bersih trutama outdoor .itu karna kompreaor overheat amper tinggi lebih bagus diganti .
Assalamualaikum bang saya mau nanya masalah AC saya mereknya Sharp pas di hidup pertama dingin sesudah 15menit kompresor mati terus setengah jam dingin lg kenapa bang terima kasih
@JohanChannel
Жыл бұрын
Kompresor nya saja atau sama fan nya mas matinya
mau nanya om, kl freon ditambah ttp arus/ampere ga naik kenapa y om? pas ditambah freon yg naik hanya tekanan.. jenis refrigerantnya R22.. tks
@JohanChannel
Жыл бұрын
Kemungkinan 1.kompresor ngempos kompresinya 2.banyak oli di sistem,bisa dicek saat ac mati tusuk pentil pengisian freon kalo olibnyak keluar flushing dulu. Biasanya terjadi di ac ½ pk
@MrRudywing
Жыл бұрын
@@JohanChannel flushing kompressornya atau indoor + line?
@andikss44
Жыл бұрын
nyimak kasus mirip
@baskorobas7550
Жыл бұрын
@@JohanChannel ditunggu vidionya .....bang👍
Bang AC sy LG 1 PK... Setelah di nyalakan sekitar 1 jam... AC nggak dingin... Di cek kompresor outdoor tetap nyala tapi dengung aja... Setelah AC di matikan sekitar 2 menit dan di nyalakan lg AC normal lg... 1 jam kumat lg... Kira2 masalah nya apa ya bang? Apa masalah di pipa kapiler atau kurang oli?
@JohanChannel
3 ай бұрын
Cek kondisi voltage Tegamgan PLN dan cek ko disi amper saat awal star
Bisa tidak kita mengisi oli Ac tanpa membuang Freon. Teima kasih.
@JohanChannel
Жыл бұрын
Kalo dibilang bisa atau tidak ya bisa saja cuma saya tidak menyarankan karna 1.nantinya oli pasti akan tercampur udara masuk ke kompresor 2.freon akan terhambat saat masuk ke akumulator karna proses memasukan nya itu seperti pump down yang terjadi malah ngeblok ES nanti. 3.nantinya oli akan terdorong oleh freon masuk ke kondensor epek nya kapiler gak lancar oleh oli Itu yang saya tau.beda ketika kita menambah oli saat tanpa freon.
Bang maaf mw tanya, saya pny ac Panasonic alowa 1pk R32 dg kondisi: 1. Indoor n outdoor bersih abis dicuci. 2. Capasitor outdoor sdh diganti baru. 3. Tekanan freon hny 125 psi, coba ditambah freon tp tekanan ga naik, yg naik amperenya sj. 4. Pipa inlet n outlet kondisi dingin berair. 5. AC tdk dingin, suhu 26C sj n tdk bs turun lg, klo di remote 24C maka kompresor akan nyala terus menerus, jd boros listrik. Kira2 apanya ya bang? Apakah kompresor kurang oli krn bunyi agak berisik tp bs jg dr body outdoor. Sktr 1thn yll pernh bocor evapnya tp sdh beres. Mulai ga dingin sktr seminggu yll. Mohon petunjuknya ya bang.. Terimakasih
@JohanChannel
Жыл бұрын
Pastikan evaporator bersih maksimal terutama di bagian bawah pada evaporator biasanya banyak lendir. Karna beberapa kali saya temukan kondisi kotor.
@entabunsayuti9144
Жыл бұрын
@@JohanChannel siap bang, indoor bag got air sdh dilepas n dibersihin, blower dilepas n evap bag bwh jg sdh dibersihin.. Outdoor dibersihkan sirip kondensernya, kipas berputar dg lancar.
Bang ? Mau nanya saya dapat trouble di AC panasonic R32 masalah nya itu mati hidup. Modul dan thermistor sdah sya ganti trus sya cek tekanan fronnya sekitar hampir 150 psi. Tpi pipa besarnya gak dingin bang tpi pipa kecilnya dingin bang. Apa yah masalah nya bang ? Kipas dan kompresor mati nyala mati nyala bang
@muhammadnovalhabibi1510
Жыл бұрын
Trus timer nya kedip" bang
@JohanChannel
Жыл бұрын
AC brapa PK mas
@dsinlaeloechanel5338
Жыл бұрын
Sama kasus yang saya hadapi di lapangan Bang. Mohon penjelasan. Ac 1/2 PK???
mas johan mau tanya, kompresor mati hidup ya sekitar 10 menit cuma ampere gak naik, hidup lagi tunggu lama, apa sebabnya yaa, kapasitor normal, overload normal.
@JohanChannel
Жыл бұрын
Ini kompresor nya atau sama kipas Fan nya yang mati
@dzakikikibhandi3173
5 ай бұрын
Ikut nyimak mas, kipas dan kompresor nya mati mas, gimana itu
@pramuji3339
5 ай бұрын
kipasnya hidup tapi kompresor mati hidup
Mau nanya di bung Johan, kalau kompresor hidup tiba2 mati dalam hitungan detik, kemudian hidup lagi terus bebera detik kembali mati, bagaimana solusinya. Terimakasih.🙏
@JohanChannel
Жыл бұрын
Kompresor nya saja atau 1 unit outdoor kipas dan kompresor nya yang mati hidup mas
@andro-2637
Жыл бұрын
Unit outdoor bro, kipas dan kompresor.
@JohanChannel
Жыл бұрын
1.bisa dari tekanan freon berkurang 2.thermistor eror
Om saya mau nanya ac saya outdoor nya nyebarin listrik teknisi nya bilang kompresor nya apa bisa d benerin ya
@JohanChannel
Жыл бұрын
Malsud nya gmna mas
@ahmadfahmi5169
Жыл бұрын
@@JohanChannel ngmng nya short body emg gtu ya
@JohanChannel
Жыл бұрын
Iya bisa saja bikan dari kompresor coba balik kabel pada unit outdoor nya antara netral dan fasa
Saya ada case di AC baru. Karna kebocoran yg tidak ketemu2. Akhirnya mengharuskan 4x isi freon karna freon habis. Apa oli juga ikut berkurang karna faktor itu bang? Terima kasih
@JohanChannel
Жыл бұрын
Betul lama2 oli akan berkurang
@kevinal-hasbi4213
Жыл бұрын
@@JohanChannel kira2 solusinya gmna bang? Diisi lagi olinya kah? Apa biarin aja?
@JohanChannel
Жыл бұрын
Solusinya plcari kebocpran nya lali oli ditambah
@kevinal-hasbi4213
Жыл бұрын
@@JohanChannel siap, terima kasih bang. Tpi kondisi freon kudu isi apa kosong bang?
Bg ijin bertanya AC saya d hidup kan slama 8 jam, outdoor fan nya berputar trus apakah itu normal???
@JohanChannel
Жыл бұрын
Tergantung Mas kalo ukuran kapasitas ac dan ruangan BTU nya sesuai tidak normal
@repnasyulena5496
Жыл бұрын
Bang saya mau tanya AC saya 1 PK panasonic, AC saya udah tidak dingin dan baru beberapa detik mati itu kenapa yak bang,dan kalo emang harus dibenerin kira kira biayanya kena berapa, tolong penjelasannya bang
@JohanChannel
Жыл бұрын
Timer pada indoor berkedip atau tidak mas